• Title/Summary/Keyword: slightly cold

Search Result 232, Processing Time 0.023 seconds

Cold Pressor Response to Seasonal Variation in Winter and Summer (국소한냉자극이 전신 및 국소혈액순환에 미치는 영향 -제 2 보 : 동계 및 하계의 계절변화에 따른 한냉반응-)

  • Park, Won-Gyun;Chae, E-Up
    • The Korean Journal of Physiology
    • /
    • v.17 no.2
    • /
    • pp.93-101
    • /
    • 1983
  • A possibility whether the appearance of adaptation to cold climate during winter could occur or not in Taegu area was evaluated by comparing the data obtained in winter with that obtained by the same method in summer. Circulatory response was induced by the immersion of one hand in the cold water. The systemic and local responses in the blood circulation from the immersed hand and the unimmersed opposite hand were observed simultaneously. In addition Galvanic skin resistance(GSR) that is influenced by the activity of autonomic nervous system and the vascular tonicity was recorded. The experiment was performed by examining sixty healthy college students in winter and fifty in summer, whose mean age was 21.0, mean weight $60.6{\pm}0.90\;kg(male)$ and $48.3{\pm}0.98\;kg(female)$. The cold stimulus was applied by immersing the left hand into the cold water of $5^{\circ}C$ for 3 minutes, and the response was observed on immersed left hand and unimmersed right hand simultaneously. The observation was made through determining mean blood pressure, heart rate, amplitude of photoelectric capillary pulse (APCP) and GSR. The results obtained are as follows: The mean blood pressure was elevated during the cold stimulation. The increase of blood pressure in summer was more remarkable than in winter. At the recovery period the blood pressure was decreased to the control level in winter but the decrease below the control level was observed in summer. The increase of heart rate in summer was more remarkable than in winter during the cold stimulation. At the recovery period heart rate in both winter and summer was decreased below the control level. During the cold stimulation the APCP was decreased on both hands in winter. However it was more prominent on left hand indicating additional direct cold effect on immersed hand. In summer, the decrease of APCP during immersion was less remarkable than that in winter, but the regain of APCP was faster than that in winter at the recovery period. And the prompt increase of APCP over the control level has been obtained at the 3 minutes of the recovery period. The GSR was remarkably increased on immersed hand but slightly decreased on unimmersed opposite hand during the cold stimulation. Thus the finding on immersed hand indicates that the local direct effect of cold water is more prominent than the systemic effect, where as the finding on unimmersed hand indicates that the circulatory response to painful stress elicited by the cold stimulation is more prominent than cold temperature itself. In summary, it seems that the systemic circulatory response to the local cold stimulation of the one hand is arised more from the secondary elicited pain sensation and less from the low water temperature. On the contrary to the report of Kim et $al^{39)}$, the adaptation phenomena in blood pressure to the relatively mild cold climate in winter was not observed in this study. The difference of circulatory response observed in this study between winter and summer may be due to the difference of the magnitude of subjective sensation of the cold water stimulation by the seasonal changes in air temperature.

  • PDF

A Study on Fatigue Damage Modelling in Cold Rolled Steel using X-ray Residual Stress (X선 잔류응력을 이용한 냉간압연강의 피로손상 모델링에 관한 연구)

  • Cho, Seok-Swoo;Joo, Won-Sik
    • Journal of Ocean Engineering and Technology
    • /
    • v.13 no.4 s.35
    • /
    • pp.55-62
    • /
    • 1999
  • Cold rolled steel has much plastic strain in the material surface produced by manufacturing process. The strain causes the variation of surface residual stress, in which influences the fatigue behavior under repeated loading. As experimental results, it was confirmed that the behavior of residual stress ${\sigma}_r$, with cycle N consisted of three stages except stress amplitude near fatigue limit in SPCC steel. On the first stage compressive residual stress decreased rapidly, on the second stage gradually, and on the last stage slightly. The relation between ${\sigma}_r$, and log N appeared linear behavior except the early part of cycle ratio $N/N_f$. The average gradient of ${\sigma}_r$, with respect to log N seemed to take a constant value without initial cycle ratio. On the other hand, the $N_f$ line was regressed by the first-order polynomial equation on ${\sigma}_r-log\;N_f$ diagram. Therefore, this study showed that both the gradient of ${\sigma}_r$, with respect to log N and the $N_f$ line was useful in predicting the cycle ratio $N/N_f$.

  • PDF

Changes of the Physical Properties of Corrugated Fiberboard Boxes for Fruit and Vegetable Packaging by Preservation Temperature and Relative Humidity (과채류 포장용 골판지 상자의 저장온도와 습도에 따른 물리적 특성 변화)

  • Lee, Myung-Hoon;Cho, Jung-Yeon;Shin, Jun-Seop
    • Journal of Korea Technical Association of The Pulp and Paper Industry
    • /
    • v.34 no.1
    • /
    • pp.46-53
    • /
    • 2002
  • This study was carried out to analyze the effects of preservation temperature and relative humidity to the physical properties of corrugated fiberboard boxes for fruit and vegetable packaging. The preservation temperature did not affect severely to physical properties of corrugated fiber-board. Relative humidity was a major cause of corrugated fiberboard box quality deterioration. The burst and compressive strengths of experimental boxes measured with Mullen high pressure tester and tong crush tester were decreased gradually as relative humidity increased from 55% to 75%. But, the strength properties slightly decreased relative humidity at 75% or higher. This tendency was the greater for single wall (SW) corrugated fiberboard box than that for double wall (DW). It is suggested that development of the water-resistant corrugated fiberboard and box be needed that can be used under the condition of low temperature and high moisture content, which are being employed in the cold chain system.

A predicting model for thermal conductivity of high permeability-high strength concrete materials

  • Tan, Yi-Zhong;Liu, Yuan-Xue;Wang, Pei-Yong;Zhang, Yu
    • Geomechanics and Engineering
    • /
    • v.10 no.1
    • /
    • pp.49-57
    • /
    • 2016
  • The high permeability-high strength concrete belongs to the typical of porous materials. It is mainly used in underground engineering for cold area, it can act the role of heat preservation, also to be the bailing and buffer layer. In order to establish a suitable model to predict the thermal conductivity and directly applied for engineering, according to the structure characteristics, the thermal conductivity predicting model was built by resistance network model of parallel three-phase medium. For the selected geometric and physical cell model, the thermal conductivity forecast model can be set up with aggregate particle size and mixture ratio directly. Comparing with the experimental data and classic model, the prediction model could reflect the mixture ratio intuitively. When the experimental and calculating data are contrasted, the value of experiment is slightly higher than predicting, and the average relative error is about 6.6%. If the material can be used in underground engineering instead by the commonly insulation material, it can achieve the basic requirements to be the heat insulation material as well.

Automated Design of Forward Extrusion Die by AutoLISP Language (AutoLISP을 이용한 전방압출 금형의 자동설계 연구)

  • 김종호;류호연;홍기곤
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 1997.04a
    • /
    • pp.584-588
    • /
    • 1997
  • Lots of forginfs used in automobile and aerospce industries are made in hot or cold working conditions, depending on the size and shape of a product. Usually the die design for new items has been first made on the basis of experiences and many know-hows accumulated in the company and then slightly modified through trial and error method to get the desired forgings without defects. Most of drawings at the die design stage have been manually drawn, butrecently some of forging companies have begun to apply a computer-aided drafting technique to the die design for reducing drafting time as well as repeatedly utilizing standardized parts form registerd data base. In this paper the automated die design technique for forward extrusion of axisymmetric forgings is developed by using AutoLISP language. For this study the representative die system is determined form the investigation of several types of forging dies being currently employed in the metal forming field and the design rules for cold extrusion die are summarized and programmed on a personal computer. A few design examples of forward extrusion die are given and discusses.

  • PDF

A Study on the Thyroid Scan Images by Different Radionuclides ($^{99m}Tc$ pertechnetate and $^{131}I$) and Multiple Views (사용핵종(使用核種) 및 주사방향(走査方向)에 따른 갑상선주사상(甲狀腺走査像)의 차이(差異)에 관한 연구(硏究))

  • Whang, Il-Yong;Chung, Soon-Il;Kim, Dong-Soo
    • The Korean Journal of Nuclear Medicine
    • /
    • v.20 no.1
    • /
    • pp.53-58
    • /
    • 1986
  • Thyroid scans using $Na^{131}I\;and\;^{99m}TcO_4^-$ in two (anterior and anterior oblique) projections were done simultaneously in 50 patients with single palpable nodule and in euthyroid state(nodular nontoxic goiter) and 20 normal subjects to evaluate the imaging ability of each radionuclide and the necessity of oblique view. In detection of a nodule as a cold or cool area, $^{99m}TcO_4^-$ was slightly superior to $^{131}I$(82 % to 78% with anterior view alone, 92% to 84% when oblique view is added in detectability), with addition of an oblique view, 5 more cold or cool area in $^{99m}Tc$ scan and 3 more $^{131}I$ scan were detected. In normal subjects $^{99m}TcO_4^-$ scan was significantly superior to $^{131}I$ scan(90% to 70%) in getting normal pattern of tracer uptake in the glands. For routine imaging study of the thyroid, $^{99m}Tc$ pertechnetate scan with multiple projection is considered to be a preferable method.

  • PDF

Heat Transfer Characteristics and Pressure Drop in Straight Microchannel of the Printed Circuit Heat Exchangers (직관 마이크로채널 PCHE의 열전달특성 및 압력강하)

  • Kim, Yoon-Ho;Seo, Jung-Eun;Choi, Young-Jong;Lee, Kyu-Jung
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.32 no.12
    • /
    • pp.915-923
    • /
    • 2008
  • The performance experiments for a microchannel printed circuit heat exchanger (PCHE) of high-performance and high-efficiency on the two technologies of micro photo-etching and diffusion bonding were performed in this study. The microchannel PCHE were experimentally investigated for Reynolds number in ranges of 100 $\sim$ 700 under various flow conditions in the hot side and the cold side. The inlet temperatures of the hot side were conducted in range of $40^{\circ}C\;{\sim}\;50^{\circ}C$ while that of the cold-side were fixed at $20^{\circ}C$. In the flow pattern, the counter flow was provided 6.8% and 10 $\sim$ 15% higher average heat transfer rate and heat transfer performance than the parallel flow, respectively. The average heat transfer rate, heat transfer performance and pressure drop increases with increasing Reynolds number in all the experiment. The increasing of inlet temperature in the experiment range has not an effect on the heat transfer performance while the pressure drop decrease slightly with that of inlet temperature. The experimental correlations to the heat transfer coefficient and pressure drop factor as a function of the Reynolds number have been suggested for the microchannel PCHE.

Numerical analysis of two experiments related to thermal fatigue

  • Bieder, Ulrich;Errante, Paolo
    • Nuclear Engineering and Technology
    • /
    • v.49 no.4
    • /
    • pp.675-691
    • /
    • 2017
  • Jets in cross flow are of fundamental industrial importance and play an important role in validating turbulence models. Two jet configurations related to thermal fatigue phenomena are investigated: ${\bullet}$ T-junction of circular tubes where a heated jet discharges into a cold main flow and ${\bullet}$ Rectangular jet marked by a scalar discharging into a main flow in a rectangular channel. The T-junction configuration is a classical test case for thermal fatigue phenomena. The Vattenfall T-junction experiment was already subject of an OECD/NEA benchmark. A LES modelling and calculation strategy is developed and validated on this data. The rectangular-jet configuration is important for basic physical understanding and modelling and has been analyzed experimentally at CEA. The experimental work was focused on turbulent mixing between a slightly heated rectangular jet which is injected perpendicularly into the cold main flow of a rectangular channel. These experiments are analyzed for the first time with LES. The overall results show a good agreement between the experimental data and the CFD calculation. Mean values of velocity and temperature are well captured by both RANS calculation and LES. The range of critical frequencies and their amplitudes, however, are only captured by LES.

A Field Measuring Study on the Thermal Environment of Human Surrounding in the Classroom Equipped with Ceiling Unit (천장형 유닛을 설치한 교실 내의 인체 주변 온열환경에 관한 실측연구)

  • Cho Sung-Woo;Im Young-Bin;Lee Kyung-Hee
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.18 no.3
    • /
    • pp.240-246
    • /
    • 2006
  • This paper performed to investigate on vertical temperature distribution, effective draft temperature (ETD) and PMV (Predicted Mean Vote) in the classroom, which is located YangSan city (Kyungsangnam-Do), Korea, is equipped with ceiling unit. The vertical temperature difference between F.L+10 cm (ankle) and F.L+120 cm (neck) of a measuring point which is adjacent corridor in the classroom showed about $1^{\circ}C$ but of measuring point which is adjacent outdoor expressed up to $4^{\circ}C$, The effective draft temperature (ETD) is -2.3 and -0.52 and 0.67 at near ceiling unit but is 1.2 and 3.3 at far from ceiling unit. The PMV of total classroom showed the range of 'Cold' and 'Slightly Cold.' Therefore, to achieve comfort condition in the classroom is equipped with ceiling unit, the location of ceiling unit and discharge angle and discharge distance from ceiling unit are very important elements.

Residual Stress Variation by Isothermal and Isochronal Annealing in Cold Rolled Alloy 600 (냉간 압연된 Alloy 600에서 등온 및 등시 소둔에 의한 잔류응력의 변화)

  • Kim, Sung Soo;Park, Duck Geun;Cheong, Young Moo
    • Korean Journal of Metals and Materials
    • /
    • v.49 no.6
    • /
    • pp.462-467
    • /
    • 2011
  • In order to understand why annealing at $480^{\circ}C$ for several hour prevents the initiation of PWSCC, the residual stress variation with isothermal annealing at $480^{\circ}C$ and isochronal annealing between 480 and $800^{\circ}C$ in cold rolled Alloy 600 was investigated by the XRD method. The isothermal annealing decreased residual stress slightly in the rolling direction but not in the transverse direction, whereas the isochronal annealing for two hours increased residual stress. It seemed that the decrease in residual stress by isothermal annealing was due to lattice contraction by an ordering reaction because the isothermal annealing increased hardness. The effects of the isochronal annealing could be interpreted as the influence of thermal expansion and a disordering reaction.