• Title/Summary/Keyword: slice test

Search Result 104, Processing Time 0.021 seconds

Determination of Lamellar Tearing Initiation Temperatures and the Effect of Non-metallic Inclusions on Tear (라멜라균열의 생성온도와 비금속개재물의 영향)

  • 고진현
    • Journal of Welding and Joining
    • /
    • v.10 no.2
    • /
    • pp.43-50
    • /
    • 1992
  • This study was aimed at resolving uncertainties about lamellar tearing initiation temperatures and studying the effect of nonmetallic inclusions on the tear initiation. In order to measure the lamellar tearing initiation temperature, the slice bend test was conducted in the temperature range of 20.deg.C to 425.deg.C on A572 Grade 50 and A588 Grade A steels. In addition, the weld restrain test was carried out to measure directly the tear initiation temperature with A572 steel. In slice bend tests, A572 steel showed the most susceptible region to lamellar tearing to be in the range of 100 to 300.deg.C, where the steel showed the minimum ductility. The observed tear initiation by the weld restraint test was to be in the range of 200to 300.deg.C. The tears became narrower and less rounded at the susceptible temperatures. It was confirmed in this study that lamellar teraring initiated during cooling from welding in the range of 200 to 300.deg.C and they were initiated by strain aging embrittlement.

  • PDF

Efficient Test Data Compression Method (효율적인 테스트 데이터 압축 방법)

  • Jung, Jun-Mo
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2012.05a
    • /
    • pp.690-692
    • /
    • 2012
  • This pape presents the efficient test data compression method considering test power dissipation in scan test of IP core. There are many researches about test data compression using scan slice selective encoding except power dissipation. We present the new algorithm that assigns the don't care value to be a minimal hamming distance between adjacent slices. Experimental results show that the power dissipation is reduced.

  • PDF

Usefulness of the High B-value DWI in Brain Tumors (뇌종양 확산강조영상에서 High B-value의 유용성 평가)

  • Kim, Jin-tae;Byun, Jae-Hu;Park, Yong-Seong;Lee, Rae-Gon;Hwang, Seon-Kwang
    • Korean Journal of Digital Imaging in Medicine
    • /
    • v.17 no.1
    • /
    • pp.33-41
    • /
    • 2015
  • This study attempts to examine the clinical usefulness of High b-value DWI (diffusion weighted imaging) for brain tumors with an edema. Subjects were seven patients selected from 65 patients who received an MRI scan for suspected encephalopathy and confirmed diagnosis at our hospital from February to July 2015 (male: 7, average age : 66 years old). As test equipment, 3.0T MR System (ACHIEVA Release, Philips, Best, The Netherlands) and 8Channel SENSE Head Coill were used. DWI checks on the use of the variable TR 5460ms, TE 132ms, Slice Thickness 4mm, gap 1mm, Slice number 29 is, 3D T1WI is TR 8.4ms, TE 3.9ms, matrix size $240{\times}240$, Slice can set 180 piecesIt was. b value of 0, 1,000, 2,000 s/mm2 with DWI acquisition and 3D T1WI enhancement five minutes after the Slice Thickness 3mm, gap 0mm to reconstruct the upper face axis (MPR TRA CE) was. As for the experiment, in b-value 1,000 and 2,000 images, SNR and the lesion at the lesion site and CNR in the normal site opposite to the lesion are measured. WW(window width) and WL(window level) are made equal in MRICro software, and the volume of the lesion is measured from each of b-value and MPR TRA CE image. Using SPSS ver. 1.8.0.0 Mann Whitney-test was analyzed for SNR and CNR, while Kruskal-Wallis test was analyzed for volume.

  • PDF

An Internal Pattern Run-Length Methodology for Slice Encoding

  • Lee, Lung-Jen;Tseng, Wang-Dauh;Lin, Rung-Bin
    • ETRI Journal
    • /
    • v.33 no.3
    • /
    • pp.374-381
    • /
    • 2011
  • A simple and effective compression method is proposed for multiple-scan testing. For a given test set, each test pattern is compressed from the view of slices. An encoding table exploiting seven types of frequently-occurring pattern is used. Compression is then achieved by mapping slice data into codewords. The decompression logic is small and easy to implement. It is also applicable to schemes adopting a single-scan chain. Experimental results show this method can achieve good compression effect.

Clinical usefulness of facial soft tissues thickness measurement using 3D computed tomographic images (3차원 전산화단층촬영 영상을 이용한 안면 연조직 두께 계측의 임상적 유용성)

  • Jeong Ho-Gul;Kim Kee-Deog;Han Seung-Ho;Hu Kyung-Seok;Lee Jae-Bum;Park Hyok;Choi Seong-Ho;Kim Chong-Kwan;Park Chang-Seo
    • Imaging Science in Dentistry
    • /
    • v.36 no.2
    • /
    • pp.89-94
    • /
    • 2006
  • Purpose : To evaluate clinical usefulness of facial soft tissue thickness measurement using 3D computed tomographic images. Materials and Methods : One cadaver that had sound facial soft tissues was chosen for the study. The cadaver was scanned with a Helical CT under following scanning protocols about slice thickness and table speed; 3 mm and 3 mm/sec, 5 mm and 5 mm/sec, 7 mm and 7 mm/sec. The acquired data were reconstructed 1.5, 2.5, 3.5 mm reconstruction interval respectively and the images were transferred to a personal computer. Using a program developed to measure facial soft tissue thickness in 3D image, the facial soft tissue thickness was measured. After the ten-time repeation of the measurement for ten times, repeated measure analysis of variance (ANOVA) was adopted to compare and analyze the measurements using the three scanning protocols. Comparison according to the areas was analyzed by Mann-Whitney test. Results : There were no statistically significant intraobserver differences in the measurements of the facial soft tissue thickness using the three scanning protocols (p>0.05). There were no statistically significant differences between measurements in the 3 mm slice thickness and those in the 5 mm, 7 mm slice thickness (p>0.05). There were statistical differences in the 14 of the total 30 measured points in the 5 mm slice thickness and 22 in the 7 mm slice thickness. Conclusion : The facial soft tissue thickness measurement using 3D images of 7 mm slice thickness is acceptable clinically, but those of 5 mm slice thickness is recommended for the more accurate measurement.

  • PDF

Effects of Contrast Agent Concentration on the Signal Intensity and Turbo Factor of TSE and Slice-selective IR in T1-weighted Contrast Imaging

  • Han, Yong Soo;Lee, Soo Chul;Lee, Dong Yong;Choi, Jiwon;Lee, Jong Woong;Kweon, Dae Cheol
    • Journal of Magnetics
    • /
    • v.21 no.1
    • /
    • pp.115-124
    • /
    • 2016
  • The present study analyzes T1 TSE and T1 slice sel. IR (dark_fluid) signal strength according to the degree of gadolinium contrast agent dilution and analyzes the turbo factors with regard to changes in the maximum and overall signal strength to study correlations between changes and signal-to-noise ratios (SNRs) and compare peak-to-peak SNR (PSNR) enhancement in order to improve the quality of T1-weighted images. Enhancement TR (600 msec) evaluated to determine the T1 TSE turbo factor and obtain the maximum signal strength, T1WI were used sequentially to experiment with turbo factors_1-4. T1 slice sel. IR (dark-fluid) was used to sequentially test turbo factors_2-5 but not turbo factor_1 at a TR (1500 msec) and compare data at an increase in T1 of 900 msec. The T1 TSE was reduced according to the contrast agent concentration. Phantom signal strength increased, whereas turbo factors_1-4 exhibited maximum signal strength at a concentration of 3 mmol, followed by a gradual decrease. In the turbo factors_2-5, the signal strength increased sharply to maximum signal strength at 0.7 mmol, followed by a reduction. T1 TSE had a greater maximum signal strength than did T1 slice sel. IR (dark_fluid). A comparison of SNR found that T1 TSE imaging was superior (33.3 dB) in turbo factor_1 and T1 slice sel. IR (dark_fluid) was highest (33.9 dB) at turbo factor_5. A PSNR comparison analysis was not sufficient to distinguish between the images obtained with both techniques at 30 dB or higher under all experimental conditions.

Kinetic Modeling of Dewatering of Potato Slice When Soaked in Concentrated Solution (고농도 용액에 침지시 감자 절편의 동력학적 탈수 모델링에 관한 연구)

  • 최동원;신해헌
    • The Korean Journal of Food And Nutrition
    • /
    • v.13 no.5
    • /
    • pp.477-482
    • /
    • 2000
  • For the purpose of explaining the dewatering phenomena of potato slice soaked in concentrated solution three models were proposed. Earlier model cannot explain the dewatering phenomena of potato slice in concentrated solution because of limiting its condition which is necessary to build a model. Therefore other three models were suggested and a model based on Fick\`s second law of mass transport at infinite plate conditions and numerical analysis was test model for explaining dewatering phenomena of potato soaked in concentrated solution. Apparent diffusion coefficient of water could be readily estimated from model III, and it could explain adequately the difference of the dewatering phenomena of various soaking conditions.

  • PDF

A Comparative Study on Buffer Characteristic of Indirect Moxibustion (격물구(隔物灸)의 격물(隔物) 특성에 따른 온열자극 비교연구)

  • Wang, Kai-Hsia;Kim, Eun-Jung;Cho, Hyun-Seok;Kim, Kap-Sung;Lee, Seung-Deok;Kim, Kyung-Ho
    • Journal of Acupuncture Research
    • /
    • v.29 no.5
    • /
    • pp.75-85
    • /
    • 2012
  • Objectives : Indirect moxibustion is one of the thermotherapy in Korean medicine and buffer of ginger and mankshood slice are common materials to be used. However it is difficult to control the power of thermal stimulation and the stimulation is greatly influenced by the characteristic of buffer. So we research on the buffer characteristic of indirect moxibustion according to the thickness, diameter and water content changes. Methods : We used thermocouples to measure temperature from surface to depth of 2, 4, 6, 8, 10, 12, 14mm on tissue model and calculated peak temperature($^{\circ}C$). The data were analyzed with student t-test and one-way ANOVA(p<0.05). Results : 1. The peak temperature of indirect moxibustion with ginger were determined by thickness of ginger slice and temperature changes according to the thickness at intervals of 1mm but according to the diameter at intervals of 4mm. 2. The peak temperature of indirect moxibustion with mankshood were determined by thickness of mankshood slice also. The peak temperature of mankshood moxibustion was higher than that of ginger moxibustion. 3. In this study, 2mm-thick-ginger slice and 3mm-thick-mankshood slice were suitable for indirect moxibustion. Variation in the thickness of which is more efficient to control the power of thermal stimulation on indirect moxibustion. 4. The more water loss we got on ginger slice, the higher peak temperature we measured at the surface of moxibustion. But the thermal stimulation was not conducted more than 2mm in the depth. 5. The thickness and water content of buffer are important in indirect moxibustion. Conclusions : The temperature of indirect moxibustion depends on the thickness of buffer than the diameter of it. Therefore, it is more efficient according to the thickness of buffer so that we control the power of thermal stimulation. And water content of buffer is one of the important factor in indirect moxibustion.

Evaluation of Cerebral Aneurysm with High Resolution MR Angiography using Slice Interpolation Technique: Correlation wity Digital Subtraction Angiography(DSA) and MR Angiography(MRA) (Slice Interpolation기법의 고해상도 자기공명혈관조영술을 이용한 뇌동맥류의 진단 : 디지탈 감산 혈관조영술과 자기공명 혈관조영술의 비교)

  • ;;;Daisy Chien;Gerhard Laub
    • Investigative Magnetic Resonance Imaging
    • /
    • v.1 no.1
    • /
    • pp.94-102
    • /
    • 1997
  • Purpose: There have been some efforts to diagnose intracranial aneurysm through a non-invasive method using MRA, although the process may be difficult when the lesion is less than 3mm. The present study prospectively compares the results of high resolution, fast speed slice interpolation MRA and DSA thereby examing the potentiality of primary non-invasive screening test. Materials and Methods: A total of 26 cerebral aneurysm lesions from 14 patients with subarachnoid hemorrhage from ruptured aneurysm (RA) and 5 patients with unruptured aneurysm(UA). In all subjects, MRA was taken to confirm the vessel of origin, definition of aneurysm neck and the relationship of the aneurysm to nearby small vessels, and the results were compared with the results of DSA. The images were obtained with 1.5T superconductive machine (Vision, Siemens, Erlangen, Germany) on 4 slabs of MRA using slice interpolation. The settings include TR/TE/FA=30/6.4/25, matrix $160{\times}512$, FOV $150{\times}200$, 7minutes 42 seconds of scan time, effective thickness of 0.7 mm and an entire thickness of 102. 2mm. The images included structures from foramen magnum to A3 portion of anterior cerebral artery. MIP was used for the image analysis, and multiplanar reconstruction (MPR) technique was used in cases of intracranial aneurysm. Results: A total of 26 intracranial aneurysm lesions from 19 patients with 2 patients having 3 lesion, 3 patients having 2 lesions and the rest of 14 patients having 1 lesion each were examined. Among those, 14 were RA and 12 were UA. Eight lesions were less than 2mm in size, 9 lesions were 3-5mm, 7 were 6-9mm and 2 were larger than IOmm. On initial exams, 25 out of 26 aneurysm lesions were detected in either MRA or DSA showing 96% sensitivity. Specificity cannot be estimated since there was no true negative of false positive findings. When MRA and MPR were used concurrently for the confirmation of size and shape, the results were equivalent to those of DSA, while in the confirmation of aneurysm neck and parent vessels, the concurrent use of MRA and MPR was far superior to the sole use of either MRA or DSA. Conclusion: High resolution MRA using slice interpolation technique showed equal results as those of DSA for the detection of intracranial aneurysm, and may be used as a primary non-invasive screening test in the future.

  • PDF

The evaluation of the radiation dose and the image quality during MDCT using Glass Rod Detector (유리선량계를 이용한 복부 MDCT 검사시 피폭선량 및 화질평가)

  • Kim, Chang-Gyu;Park, Byung-Sub
    • Journal of Digital Convergence
    • /
    • v.10 no.2
    • /
    • pp.249-254
    • /
    • 2012
  • Assessing the exposure dose and the obtained image during the abdominal radiography with 128-slice MDCT scanner and 4-slice MDCT scanner which are recently being used in clinics using the body tissue-equivalent phantom and the glass dosimeter, the results were as follows. During the CT test for the abdomen, the absorbed dose was $35.8{\pm}0.46mGy$ in 4-MDCT, and $19.03{\pm}0.25mGy$ in 128-MDCT, which indicated that the radiation dose necessary to obtain the image meaningful to diagnosis was required less by 128-MDCT(P<0.05). As a result of analyzing the image obtained from the abdominal test using MDCT with a 5-point Likert scale, 4-MDCT showed the result of 3.52 points, and 128-MDCT showed the result of 4.01 points, that is, the image quality of 128-MDCT was evaluated high, and there was a statistically significant difference. In the results above, it is considered that 128 slice MDCT scanner will be much used later as it can reduce the radiation exposure, and make us obtain the high quality of image.