• Title/Summary/Keyword: skin region

Search Result 773, Processing Time 0.023 seconds

A Study on the Effectiveness of the Manufacture of Compensator and Setup Position for Total Body Irradiation Using Computed Tomography-simulator's Images (전산화 단층 모의치료기(Computed Tomography Simulator)의 영상을 이용한 TBI(Total Body Irradiation) 자세 잡이 및 보상체 제작의 유용성에 관한 고찰)

  • Lee Woo-Suk;Park Seong-Ho;Yun In-Ha;Back Geum-Mun;Kim Jeong-Man;Kim Dae-Sup
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.17 no.2
    • /
    • pp.147-153
    • /
    • 2005
  • Purpose : We should use a computed tomography-simulator for the body measure and compensator manufacture process was practiced with TBI's positioning in process and to estimate the availability.,Materials and Methods : Patient took position that lied down. and got picture through computed tomography-simulator. This picture transmitted to Somavision and measured about body measure point on the picture. Measurement was done with skin, and used the image to use measure the image about lungs. We decided thickness of compensator through value that was measured by the image. Also, We decided and confirmed position of compensator through image. Finally, We measured dosage with TLD in the treatment department.,Results : About thickness at body measure point. we could find difference of $1{\sim}2$ cm relationship general measure and image measure. General measure and image measure of body length was seen difference of $3{\sim}4$ cm. Also, we could paint first drawing of compensator through the image. The value of dose measurement used TLD on head, neck, axilla, chest(lungs inclusion), knee region were measured by $92{\sim}98%$ and abdomen, pelvis, inquinal region, feet region were measured by $102{\sim}109%$.,Conclusion : It was useful for TBI's positioning to use an image of computed tomography-simulator in the process. There was not that is difference of body thickness measure point, but measure about length was achieved definitely. Like this, manufacture of various compensator that consider body density if use image is available. Positioning of compensator could be done exactly. and produce easily without shape of compensator is courted Positioning in the treatment department could shortened overall $15\{sim}20$ minute time. and reduce compensator manufacture time about 15 minutes.

  • PDF

Reliability of Muscle Evaluation with a Tactile Sensor System (촉각센서를 이용한 근육평가의 신뢰도 조사)

  • Oh, Young-Rak;Lee, Dong-Ju;Kim, Sung-Hwan;Kim, Mee-Eun;Kim, Ki-Suk
    • Journal of Oral Medicine and Pain
    • /
    • v.30 no.3
    • /
    • pp.337-344
    • /
    • 2005
  • A tactile sensor employs a piezoelectric element to detect contact frequency shifts and thereby measure the stiffness or softness of material such as tissue, which allows the sensor to be used in many fields of research for urology, cardiology, gynecology, sports medicine and caner detection and especially for cosmetics and skin care. In this study, reliability of the tactile sensor system was investigated with its manual application to the muscles susceptible to temporomandibular disorders. Stiffness and elasticity of anterior temporalis, masseter and trapezius muscles were calibrated bilaterally from 5 healthy men with an average of 24.5$\pm$0.94 years. The tactile sensor used in this study had a computer-controlled and motor-driven sensor unit which automatically pressed down on the skin surface over the muscles being measured and retracted, thereby providing the hysteresis curve. The slope of the tangent of the hysteresis curve (${\Delta}f/{\Delta}x$) is defined as stiffness of the muscle being measured and the distance between the two parts of the curve as its elasticity. To determine inter-examiner reliability, all the measurements were performed by the two examiners A and B, respectively and the same examination were repeated with an interval of 2 days for intra-examiner reliability. The results from this study demonstrated high reliability in measuring stiffness and elasticity of anterior temporalis, masseter and upper trapezius muscles using a tactile sensor system. It is suggested that the tactile sensor system can be a highly reproducible and effective instrument for quantitative evaluation of the muscle in head and neck region.

Image and Exposure Dose in Accordance with Radiation Quality on Plain Chest Radiography (흉부촬영(胸部撮影)에서 증감지(增感紙)-필름계의 선질변화(線質變化)에 따른 감도(感度)와 화질에 관(關)한 연구(硏究))

  • Kim, Jung-Min;Kim, Dong-Huan;Hayashi, Taro;Ishida, Yuji;Maeda, Mika;Sakura, Tatsuya
    • Journal of radiological science and technology
    • /
    • v.15 no.1
    • /
    • pp.65-78
    • /
    • 1992
  • Routine chest radiography is generally imaged by high voltage technique but some radiological technologists use low voltage for imaging. High voltage is usually said between $120\;kV{\sim}140\;kV$. Some RTs like using heavy filtration but others seldom like using it. However which is better for use calcium tungustate film screen system or ortho system and high contrast film or wide latitude c-type film for the exculusive use of chest radiography. We could not make a decision which is ideal method for use. In my opinion any method is not always exellent for chest radiography. In my experiments that I had at Kaken hospital in Japan last year I expect to keep the balance between image quality and diagnostic range and to reduce radiation dose for patients. My experiments are as follows. 1. We have looked into system characteristics(speed and contrast) in accordance with kVp($80{\sim}140$) and added filter($no{\sim}1/16\;VL$) in three screen film systems(BX3+CRONEX4, SRO750+MGH, SRO750+MGL). 2. We have looked into skin dose and film dose with same D=1.8 lung field density in accordance with kVp($80{\sim}140$) and added filter($no{\sim}1/16\;VL$) in three screen film systems. 3. We have compared with the evaluation between correlation of physical image quality(MTF) and optical diagnostic capability. Result are follows. 1. Speed of BX3+CRONEX4 became higher in accodance with kVp and thickness of filter but speed of ortho system was not as like regular system. Thicker filter diminished the speed over 100 kV range in SRO750+MGL. In case of SRO750+MGH speed of 1/16VL filter was looked into lower than speed of 1/4VL filter. Sensitivity of ortho system depends on tube voltage and added filter. 2. Skin dose has been detected $225\;{\mu}Gy{\sim}66\;{\mu}Gy$ in BX3+CRONEX4 from 80 kV, no filter to 140 kV, 1/16VL filter. SRO750+MGH could reduce the patient dose $1/2{\sim}1/3$ level in comparison to that of BX3+CRONEX4. 3. The higher kV was the worse MTF became the thicker filter was the worse MTF became too. MTF of BX3+CRONEX4 was detected better than MTF of SRO750+MGH but SRO750+MGH's optical detectability of small lesion in lung field came out better than that of BX3+CRONEX4. Conclusion Recently routine chest radiography is generally imaged by high voltage but it seems to be there are some questions in using of film screen combination. In high voltage chest radiography the subject contrast will come down that means latitude become wider. In this case if we select the low contrast film screen system(C or L type) the film contrast will fall down extremly and detectability of small lesion will be deteriorated. Wide latitude C, L type film has a merit of high detectability on mediastinum. Furthermore high contrast film screen system has the advantage to keep the high contrast in low density region as like mediastinum and heart shadow. Therefore in low subject contrast high voltage chest radiography we would rather choose the high contrast film screen system(H type) I think. From a view point of patient dose detectability of mediastinum and lung field. The optimum technical facter was found out 120 kV, 1/16VL filter : BX3+CRONEX4, 140 kV, 1/4VL filter : SRO750+MGH, 100 kV, 1/4VL filter : SRO750+MGL.

  • PDF

Effect of White and Blue Wind Net Shading on the Quality of 'Fuji' and 'Hongro' Apple Fruits (백색 및 청색 방풍망 차광 처리가 '후지', '홍로' 사과 과실의 품질에 미치는 영향)

  • Kang, Kyeong-Jin;Seo, Jeong-Hak;Yoon, Hong-Ki;Seo, Jeong-Seok;Joo, Jung-Il;Chun, Jong-Pil
    • Journal of Bio-Environment Control
    • /
    • v.29 no.2
    • /
    • pp.120-129
    • /
    • 2020
  • In Yesan-gun, Korea's main apple-producing region, the area of apple cultivation and yield are declining. In particular, the worsening quality of fruits due to unusually high temperatures amid recent climate change has also become a major challenge for apple orchards located on flatlands. The objective of this research is to investigate quality changes of apples according to different growing environments, depending on the shade of the sun, by covering the trees with different colors of wind nets. A white and blue wind nets with a hole size of 2 × 2 mm is installed on two experimental trees, 17-year-old 'Fuji' and 'Hongro', which are planted 1.5 m × 3.5 m in the north-south direction. Treatment of wind nets effectively lowered fruit surface temperature regardless of apple variety. When measuring the temperature of the fruit surface at 2 pm, the temperature of the air was 34.8℃, but the 'Fuji' of the untreated blocks was the highest at 40.0℃, while the blue wind net and the white wind net were significantly lower at 34.9℃ and 36.6℃, respectively. In 'Hongro', the results showed that the surface temperature was effectively lowered by recording 38.3℃ for the blue wind net and 38.5℃ for the white wind net treatment when the untreated one was 44.2℃. According to the color difference in 'Fuji', the skin redness (a) was the lowest with untreated control at 16.5, but the blue and white wind net treatment higher at 18.0 and 19.3, respectively. In 'Hongro', the white wind net treated fruit also showed a much higher skin redness than the untreated control of 28.1, showing much higher a of 34.9. Sunburn damage in 'Fuji' apples amounted to 9.4% in untreated control. However, the blue and white wind net treatment revealed to 3.8% and 4.2%, respectively. In 'Hongro', those damage in the fruits treated with blue or white wind net, accounted for only 8.8% and 12.4%, respectively, significantly lower than 28.8% occurrence of untreated one. And, these results were understood to be the result of low UV radiation being blocked by the treatment of wind nets.

Person Identification based on Clothing Feature (의상 특징 기반의 동일인 식별)

  • Choi, Yoo-Joo;Park, Sun-Mi;Cho, We-Duke;Kim, Ku-Jin
    • Journal of the Korea Computer Graphics Society
    • /
    • v.16 no.1
    • /
    • pp.1-7
    • /
    • 2010
  • With the widespread use of vision-based surveillance systems, the capability for person identification is now an essential component. However, the CCTV cameras used in surveillance systems tend to produce relatively low-resolution images, making it difficult to use face recognition techniques for person identification. Therefore, an algorithm is proposed for person identification in CCTV camera images based on the clothing. Whenever a person is authenticated at the main entrance of a building, the clothing feature of that person is extracted and added to the database. Using a given image, the clothing area is detected using background subtraction and skin color detection techniques. The clothing feature vector is then composed of textural and color features of the clothing region, where the textural feature is extracted based on a local edge histogram, while the color feature is extracted using octree-based quantization of a color map. When given a query image, the person can then be identified by finding the most similar clothing feature from the database, where the Euclidean distance is used as the similarity measure. Experimental results show an 80% success rate for person identification with the proposed algorithm, and only a 43% success rate when using face recognition.

Analysis of Effectiveness of Spectrum of Energy and Image Quality Evaluation by Aluminium Filter in the added Compound Filtration (에너지 스펙트럼과 화질평가를 통한 복합부가여과에서 알루미늄 여과판의 효율성 분석)

  • Kim, Sang-Hyun;Choi, Jae-Ho
    • Journal of radiological science and technology
    • /
    • v.38 no.3
    • /
    • pp.187-197
    • /
    • 2015
  • This study analysed the effectiveness of aluminium(Al) filter in the added compound filtration for the removal of characteristic radiation by energy spectrum and image evaluation. 0.1, 0.2, 0.3 mm copper with and without 1 mm Al were evaluated. The energy spectrum was measured using the GATE and evaluated separately by each energy. Image quality was evaluated by PSNR, MAE, MSE, CNR, SNR and qualitative analysis was performed by seven items for resolution and contrast from chest x-ray criteria of National Cancer Screening and Cardiovascular evaluation table. In the analysis of the quality of the energy per photon spectrum with the exception of a low energy region, without Al were superior in all area. PSNR MAE, MSE, CNR, SNR and qualitative analysis were the same or slightly better. PSNR was over 30 dB and all significant and the p>0.05 in the T-test of qualitative analysis. The energy spectrum and image quality have little difference between before and after use of Al filter. Therefore, it is effective to use the Al filter for the radiation dose management with the compensation capability of DR system.

Dose Distribution in Solid Phantom by TLD with a Metal Plate of Various Thicknesses (다양한 두께의 금속판을 얹은 TLD를 이용하여 구한, 고체 팬텀 내에서의 선량분포)

  • Kim, Sookil
    • Progress in Medical Physics
    • /
    • v.10 no.2
    • /
    • pp.83-88
    • /
    • 1999
  • Purpose: TLD experiments were set up to measure the dose distribution and to analyze the influence on dose measurement of thin metal plate and solid water phantom. The aim of the present study was to investigate the build-up effect of metal plate loaded on TLD chip and depth dose in the controlled environment of phantom measurements. Materials and Methods: Measurements were done by using LiF TLD-100 loaded by a thin metal plate with the same surface area (3.2$\times$3.2 $\textrm{mm}^2$) as TLD chip. TLD chips loaded with one metal plate from three different metal plate (Tin, Copper, Gold) of different thicknesses (0.1, 0.15, 0.2, 0.3 mm) were used respectively to measure radiation dose. Using the TLD loaded with one metal plate, surface dose and the depth dose at the build-up maximum region were investigated. Results: Using a metal plate on TLD chip increased the surface dose. Surface dose curve shows the dose build-up against equivalent thickness of metal to water. The values of TL reading obtained by using metal plate at depth of build-up maximum are about 8% to 13% lower than those obtained by normal TLD chip. Conclusion: The metal technique used for TLD dosimetry could provide clinicals information about the build-up of dose up to 4.2mm depth in addition to a depth dose distribution. The results of TLD with a metal plate measurements may help with decisions to boost or bolus certain areas of the skin.

  • PDF

Molecular Detection and Characterization of Orf Virus from Outbreak of Contagious Pustular Dermatitis in Korean Indigenous Goats (한국 재래 산양의 전염성 농피성 피부병에서 orf virus의 검출과 B2L 유전자를 통한 계통발생학적 분석)

  • Park, Jin-Ho;Kim, Guk-Jong;Choi, Wook;Kim, Eun-Ha;Han, Jae-Chul;Ou, Sung-Guk;Lee, Jon-Hwa;Cho, Mae-Rim;Song, Hee-Jong;Chae, Jun-Seok
    • Journal of Veterinary Clinics
    • /
    • v.21 no.2
    • /
    • pp.102-108
    • /
    • 2004
  • Orf virus (ORFV), a member of genus Parapoxvirus (family-Poxviridae), a causative agent of contagious ecthyma in sheep and goat leading to a condition commonly known as vesicular dermatitis. Recently, twelve goats from Iksan in Jeonbuk province were observed with clinical signs like necrotic vesicular lesions around the mucosa of mouth, nasal cavity, eye, ear, teats, abdomen and groin. Based on these clinical symptoms, contagious ecthyma infection was suspected. The skin scrapping was collected from lesions for isolation of DNA and subsequent PCR amplification of ORFV specific 235 bp region of B2L gene. All of the samples were found positive by PCR analysis. Sequencing and further phylogenetic analysis of the PCR product revealed 100% identity to Japan isolate of ORFV (Okinawa, GenBank accession number AB080769), and showed 99.6% of similarity to New Zealand strain (NZ-2, GenBank accession number U06671). It was concluded that ORFV strain detected in the present study is homologous to Japan isolate and New Zealand strain. The PCR test based on amplification of B2L gene is a highly useful tools for rapid and specific diagnosis of contagious ecthyma.

A Case of Descending Necrotizing Mediastinitis (하행 괴사성 종격동염의 치험례)

  • Lee, In Soo;Choi, Hwan Jun;Lee, Han Jung;Lee, Jae Wook;Lee, Dong Gi
    • Archives of Plastic Surgery
    • /
    • v.36 no.3
    • /
    • pp.351-355
    • /
    • 2009
  • Purpose: Cervical necrotizing fasciitis tends to involve the deep soft tissues and spread caudally to the anterior chest and mediastinum, often resulting in major complications and death. It may rapidly spread into the thorax along fascial planes, and the associated diagnostic delay results in this descending necrotizing mediastinitis. So, aggressive multidisciplinary therapy with surgical drainage is mandatory. We present a very rare case of descending necrotizing mediastinitis with literature review. Methods: A 53 years old male visited our department 7 days after trauma in neck. His premorbid conditions and risk factors of necrotizing fasciitis were concealed hepatoma, trauma history, chronic liver disease, and nutrition deficit. Computed tomographic scans of the head and neck region were performed in this patient : signs of necrotizing fasciitis, were seen in the platysma, sternocleidomastoid, trapezius muscle and strap muscles of the neck. Fluid accumulations involved multiple neck spaces and mediastinum. At the time, he diagnosed as necrotizing fasciitis on his neck and anterior chest. Necrotic wound was excised serially and we treated this with the Vacuum - assisted closure(VAC, Kinetics Concepts International, San Antonio, Texas) system device. After appropriately shaping the sponge and achieving additional 3 pieces drainage tubes in the pockets, continuous negative pressure of 125 mmHg was applied. The VAC therapy was utilized for a period of 12 days. Results: We obtained satisfactory results from wide excision, abscess drainage with the VAC system, and then split thickness skin graft. The postoperative course was uneventful. Conclusion: The refined technique using the VAC system can provide a means of simple and effective management for the descending necrotizing mediastinitis, with better cosmetic and functional results. Finally, the VAC system has been adopted as the standard treatment for deep cervical and mediastinal wound infections as a result of the excellent clinical outcome.

A Case of Disseminated Mycobacterium bovis Infection after BCG Vaccination (Tokyo strain) in an Apparently Immunocompetent Infant (면역기능이 정상인 영아에서 동경주 BCG 백신 접종 후 발생한 파종성 Mycobacterium bovis 감염 1예)

  • Paik, Ji Yeun;Choi, Jae Hong;Kim, Min Kyung;Choi, Eun Hwa;Lee, Hoan Jong;Park, Kyoung Un
    • Pediatric Infection and Vaccine
    • /
    • v.18 no.1
    • /
    • pp.91-96
    • /
    • 2011
  • Bacille Calmette-Gu$\acute{e}$rin (BCG) vaccine is a live attenuated vaccine derived from Mycobacterium bovis. Frequent complications after BCG vaccination are localized ulcer formation and regional lymphadenitis, but there could be rarely severe systemic reactions to BCG vaccine such as osteomyelitis and disseminated BCG infection. Although disseminated BCG infection can be complicated in infants with underlying immunodeficiency after BCG vaccination, it is very unlikely to develop in immunocompetent infants or children. We report a 13-month-old infant who presented with fever, skin nodules, and multiple enlarged lymph nodes 5 months following BCG vaccination. She was diagnosed with disseminated BCG infection by PCRconfirmed M. bovis BCG infection at ${\geq}$2 anatomical sites beyond the region of vaccination. The patient showed no obvious evidence of immunodeficiency as judged on the basis of previous disease history, plasma immunoglobulin levels, B and T lymphocytes counts in peripheral blood, DHR (dihydrorhodamine 123 fluorescence) test and HIV test. She started antituberculous treatment with isoniazid and rifampin, and now, apparently her symptoms have been improved.