This study analysed the effectiveness of aluminium(Al) filter in the added compound filtration for the removal of characteristic radiation by energy spectrum and image evaluation. 0.1, 0.2, 0.3 mm copper with and without 1 mm Al were evaluated. The energy spectrum was measured using the GATE and evaluated separately by each energy. Image quality was evaluated by PSNR, MAE, MSE, CNR, SNR and qualitative analysis was performed by seven items for resolution and contrast from chest x-ray criteria of National Cancer Screening and Cardiovascular evaluation table. In the analysis of the quality of the energy per photon spectrum with the exception of a low energy region, without Al were superior in all area. PSNR MAE, MSE, CNR, SNR and qualitative analysis were the same or slightly better. PSNR was over 30 dB and all significant and the p>0.05 in the T-test of qualitative analysis. The energy spectrum and image quality have little difference between before and after use of Al filter. Therefore, it is effective to use the Al filter for the radiation dose management with the compensation capability of DR system.
Keywords
Aluminium filter; Energy spectrum; Image evaluation; Characteristic radiation; Skin dose;
Citations & Related Records
Times Cited By KSCI : 7  (Citation Analysis)
연도 인용수 순위
1 Raymond P. Rossi, Reduction of Radiation Exposure in Radiography of the chest, Radiology, 144, 909-914, 1982   DOI
2 S. H. Lee, J. Heh , J. W. Lee, J. M. Kim, Clinical application of inverter type x-ray generator, Journal of radiological science and technology, 15(1), 107-113, 1992
3 C. H. Lee, C. S. Lim, A Study on Added Filters for Reduction of Radiation Exposure Dose in Skull A-P Projection, Journal of the Korea Academia-Industrial cooperation Society, 12(7), 3117-3122, 2011   DOI
4 S. S. Shin, Reducing method dose using auto exposure control system in digital radiography, Journal of radiological science and technology, 36(2), 111-122, 2013
5 S. Yang, J. B. Han, N. G. Choi, S. G. Lee, The Review of Exposure Index in Digital Radiography and Image Quality, Jounrnal of Radiation Protection, 38(1), 29-36, 2013   DOI
6 Uffmann M, Cornelia S, Digital Radiography: Balance between image quality and required radiation dose, Eur. J. Radil, 72, 202-208, 2009   DOI
7 K. J. Lee, M. G. Kim, J. W. Lee, H. C. Kim, Research for the environmental optimization of dose and image, Journal of the institute of engineers of korea, 50(2), pp. 203-206, 2013
8 W. I. Cho, Y. K. Kim, G. D. Lee, Change of dose exposure and improvement of image quality by additional filtration in mammography, Journal of Radiation Protection, 38(2), 78-90, 2013   DOI
9 G. S. Shin, J. H. Choi, Y. H. Kim, J. M. Kim , C. G. Kim, Patient dose in mammography, Journal of radiological science and technology, 28(4), 293-299, 2005
10 S. J. Moon, Y. G. Kim, S. G. Lee, Reduction of patient dose exposure and improvement of image quality by use of additional filtration in digital radiology, Korean J Digit Imaging Med, 19-25, 2010
11 Y. H. Chung, C. H. Beak, S. J. Lee, Monte carlo simulation codes for nuclear medicine imaging, Nucl. Med. Mol, 42(2), 127-136, 2006
12 Wilkinson LE, Johnston PN, Heggie JCP, A comparison of mammography spectral measurement with spectra produced using several different mathmatical models, Phys. Med. Biol, Vol. 46(5). 1575-1589, 2001   DOI
13 J. O. Lee, D. H. Jeong, S. R. Moon, Calculation of photon spectra from the tungsten target for 10MeV electron beam, Korean Journal of Medical Physics, 10(1), 55-62, 1999
14 S. S. Park, G. J. Kim, Introduction to the physics of Diagnostic Radiology, Dae Hak Seo Lim, Seoul, 135-141, 1985