• 제목/요약/키워드: skin irritation toxicity

검색결과 86건 처리시간 0.028초

A Study on the Skin Irritation Toxicity Test of Processed Sulfur in New Zealand White Rabbit

  • Jung, Hoseok;Seo, Wookcheol;Jeong, Taeseong;Kang, Hyung Won;Kim, Sungchul
    • 대한약침학회지
    • /
    • 제25권1호
    • /
    • pp.46-51
    • /
    • 2022
  • Objectives: This study was performed to evaluate the skin irritation toxicity of processed sulfur. Methods: All experiments were conducted at Medvill (Korea), an institution authorized to perform non-clinical studies, under the Good Laboratory Practice (GLP) regulations. In order to investigate skin irritation toxicity of processed sulfur, we divided the back of six rabbits into two control sites and two test sites. One of each of the two control and test sites was then designated abraded sites and intact sites. In test sites, 0.5 g of processed sulfur was applied to the back of the rabbit for 24 hours, and in control sites, 0.5 g of sterile distilled water was applied in the same way. We observed and evaluated mortality, weight, general symptoms, and skin irritation toxicity. This study was conducted with the approval of the Animal Ethics Committee (Approval number: IAC2020-1549). Results: In all experiments, no dead animals were observed. In all cases, skin coloration was observed at 24 hours after processed sulfur administration. This coloration lasted up to 48 hours and is believed to be the effect of the administration of test substances. Weight measurement indicated that weight was lost 72 hours after administration in three cases, but this is considered an accidental weight change. Normal weight gain was observed in the remaining subjects. In all animals, no skin irritation toxicity was observed, and the primary irritation index (P.I.I) was calculated as 0.0 according to Draize's evaluation method. Conclusion: The above findings suggest that it is relatively safe to apply a processed sulfur to the skin. Further research on this topic is needed to provide more specific evidence.

Mixture Toxicity of Methylisothiazolinone and Propylene Glycol at a Maximum Concentration for Personal Care Products

  • Park, Juyoung;Lee, Handule;Park, Kwangsik
    • Toxicological Research
    • /
    • 제34권4호
    • /
    • pp.355-361
    • /
    • 2018
  • Methylisothiazolinone (MIT) has been used in combination with methylchloroisothiazolinone (CMIT) for cosmetic products such as shampoo, body lotion, and skin care products. The mixture of CMIT/MIT has been found to cause allergic contact dermatitis and is thus no longer permitted for use as a preservative in leave-on cosmetics. However, MIT itself was approved as a stand-alone preservative at a maximum concentration of 100 ppm as the toxicity was derived from CMIT rather than MIT. However, in many countries, allergic skin irritation caused by MIT remains a social concern. In this study, skin irritation was assessed for the presence of MIT, propylene glycol, and their mixture using a 3D human skin model $EpiDerm^{TM}$. Although non-diluted MIT causes serious skin toxicity, skin irritation was not observed at a concentration of 100 ppm, the maximum permissible level for cosmetics and personal care products according to European regulations. Propylene glycol, the most widely used vehicle for MIT, did not cause skin irritation in the 3D skin model. The results are expected to provide information for regulatory policies and guidelines on the use of biocides in consumer products.

탁리소독음 피부외용제형의 급성경피독성시험, 피부자극시험 및 안점막자극시험 (Acute toxicity, Dermal and Ocular Irritation Studies of Taglisodog-eum ointment)

  • 이정복;최재환;김희택;김윤경;유영법
    • 대한한의학방제학회지
    • /
    • 제24권4호
    • /
    • pp.289-300
    • /
    • 2016
  • Objectives : Taglisodog-eum(TSE), a poly herbal formula, has been widely used to improve carbuncles by removing inflammation of the lymphatic channels in Traditional Korean Medicine. We previousely reported the action mechanism of TSE on experimental atopic dermatitis and the establishment of formulation for TSE ointment. In this study, we examined the toxicity test on skin and eye irritation by TSE ointment to prove the safety of Taglisodog-eum ointment in clinical use. Methods : Acute skin toxicity of the TSE ointment was evaluated in Sprague-Dawley(SD) rats. After dermal administration of TSE ointment(2,000mg/kg), body weight, mortality, and clinical signs of the rats were observed for 14days. Primary skin irritation and ocular irritation tests for TSE ointment were performed in male New Zealand White Rabbits. In dermal and ocular irritation test, body weight, mortality, clinical signs, Primary Irritation Index(P.I.I.), and The Index of Acute Ocular Irritaion(I.A.O.I.) of rabbit were observed after applying at abraded skin and eye balls with Taglisodog-eum ointment. Results : In the results of acute skin toxicity, no significant differences were found in body weight, the clinical sign and the mortality between control and TSE ointment treated group. In primary dermal irritation test, body weight, the clinical sign and the mortality were not significantly changed and Primary Irritation Index(P.I.I.) was 0.8, indicating TSE ointment as weak irritant material. In ocular irritation test, The Index of Acute Ocular Irritaion was 0.0, indicating TSE ointment as non-irritating to the eye of the rabbits. To evaluate toxicity of the TSE ointment in animal test, body weight, the clinical signs, the skin and eye irritation check were conducted; TSE ointment was considered to be weak dermal irritant in test animals. The no response of eye irritation test was observed in this experimental condition. Conclusions : According to the above toxicity test, We consider that this results is helpful for saying about the safety of TSE ointment in clinical use.

폐글리세롤을 이용한 친환경 가소제의 경구투여독성 및 피부자극성 시험 (The oral dose toxicity test and skin irritation test of eco-friendly plasticizer using crude glycerol derived)

  • 강수정;김희영;박상원;심은영;김진환
    • 한국산업보건학회지
    • /
    • 제25권3호
    • /
    • pp.322-327
    • /
    • 2015
  • Objectives: The major objective of this study is the oral dose toxicity test and skin irritation test of eco-friendly plasticizer using crude glycerol derived from the biodiesel process. Methods: Glyceroldiacetate laurate(GDL) was synthesized from glycerol monolaurat(GML) and acetic acid. The synthesis of the GDL plasticizer was measured with nuclear magnetic resonance spectroscop(NMR) and FT-IR(Fourier Transform Infrared Spectrometer). To provide information on the safety of GDL, we carried out an oral dose toxicity test for GDL in Sprague-Dawley rats. Also, we carried out a skin irritation test for GDL in New Zealand White rabbits. Results: The oral dose toxicity test in Sprague-Dawley rats showed that GDL is a non-toxic material. The result of the skin irritation test on New Zealand White rabbits showed that GDL is non-irritating. Conclusions: From the results of oral dose toxicity test and skin irritation test, we concluded that the developed plasticizer showed excellent eco-friendly property. Based on our results, we confirmed the development of an eco-friendly non-phthalate plasticizer. Applicability for PVC toys and food and drug packaging materials was found.

홍화자약침(紅花子藥鍼)의 피부자극시험 및 안점막자극시험 (The study of irritation and toxicity of Carthami oil aquapuncture solution applied topically to the skin and the eye mucous membrane)

  • 임사비나;강동철
    • 대한약침학회지
    • /
    • 제3권1호
    • /
    • pp.53-63
    • /
    • 2000
  • Carthami tinctorii Fructus is known for its good effect on diseases such as fracture, menorrhalgia, menoschesis, puerperium aneilema and so on. The study of irritation and toxicity of Carthami oil aquapuncture solution applied topically to the skin and the eye mucous membrane were carried out to prove the safety of Carthami oil aquapuncture solution in clinical use. Animal for the research was the rabbit and the solution for the test was made from Carthami semen. 6 animals were used for the skin test and 9 animals were used for the eye mucous membrane test. In results, both tests proved that Carthami oil aquapuncture solution makes no irritable reaction on skin and eye mucous membrane of rabbit. We consider that this result is helpful for saying about the safety of Carthami oil aquapuncture solution in clinical use.

Safety Evaluation of Topical Valproate Application

  • Choi, Sun Young;Seop, Song Yi;Hyun, Moo Yeol;Yoo, Kwang Ho;Kim, Beom Joon;Kim, Myeung Nam;Cho, Jae-We
    • Toxicological Research
    • /
    • 제29권2호
    • /
    • pp.87-90
    • /
    • 2013
  • The potential role of topical valproate (VPA) in hair regrowth has been recently suggested. However, safety reports of VPA as a topical formulation are lacking. Therefore, in the present study, we investigated whether VPA causes skin irritation in humans. We first performed a cell viability test and showed that VPA did not exhibit toxicity toward HaCaT keratinocytes, fibroblasts, and RBL-3H mast cells. We then performed clinical patch test and skin irritation test through transdermal drug delivery with the help of microneedle rollers. No significant findings were obtained in the clinical patch test. In the skin irritation test, only 1 patient showed erythema at 1 hr, but the irritation reaction faded away within a few hours. Erythema and edema were not observed at 24 hr. We concluded that VPA has minimal potential to elicit skin irritation. Therefore, we consider that VPA can safely be applied to human skin.

Phthalate의 피부자극시험 및 안점막자극시험에 관한 연구 (Dermal and Ocular Irritation Studies of Some Phthalates in Rabbits)

  • 이종권;김주환;이은희;김용규;홍진태;박기숙;안광수;정수연;이선희
    • Toxicological Research
    • /
    • 제17권2호
    • /
    • pp.91-96
    • /
    • 2001
  • Phthalates are widely used as plasticizers to impart softness and flexibility to normally rigid polyvinylchloride products. However, there are not much studies jar dermal and ocular irritation toxicity of phthalates. So we investigated the skin or eye irritation effect of some phthalates which was not reported. The primary skin irritation of diethyl phthalate (DEP), diisodecyl phthalate (DIDP), diisononyl phthalate (DINP), dipropyl phthalate (DPP) and dipropyl phthalate (DPrP) was studied. The ocular irritation of dibutyl phthalate(DBP), DIDP, DINP, DPP and DPrP was also studied. DEP, DIDP, DINP, DPP, and DPrP were found to be non-irritating to the skin of the test animals. DBP, DIDP, DINP and DPP were found to be non-irritating to the eye of the rabbits. DPrP caused the slight irritations to the eye in 1 or 2 days after treatment but irritation of the animals was soon recovered.

  • PDF

유전자 재조합 Human Factor VIII(GC-γ AHF)의 안전성에 관한 연구 (Safety Evaluation of Recombinant Human Factor VIII(GC-γ AHF))

  • 김민영;손장원;신민기;배미옥;김현우;최진혁;김준성;문서현;김정현
    • Toxicological Research
    • /
    • 제18권1호
    • /
    • pp.87-98
    • /
    • 2002
  • This study was conducted to evaluate the safety of a recombinant human Factor VIII(GC-$\gamma$ AHF) manufactured by Korea Green Cross Company with different technology according to the Regulation of Korean Food and Drug Administration (l 998. 12. 3). In acute toxicity test, both genders of Sprague-Dawley rats and Beagle dogs were administered intravenously with GC-$\gamma$ AHF of three doses (3,125, 625 and 125 IU/kg), and single dose of 3,125 IU/kg, respectively. No dead animal and abnormal autopsy findings were found in Control and GC-$\gamma$ AHF treated group. Therefore, the 50% lethal dose ($LD_{50}$) of GC-$\gamma$ AHF was conidered to be higher than 3,125 IU/kg in rats and dogs. In the four weeks repeated intravenous toxicity study, GC-$\gamma$ AHF was administrated intravenosly to both genders of rats and dogs with 3 doses (500, 150, 50 IU/kg). There were neither dead animals nor significant changes of body weights during the experimental Period. In addition, no significant GC-$\gamma$ AHF related changes were found in clinical sign, urinalysis and other finding. Statistically changes were observed in hematological, biochemical and organ weight parameters of treated groups: however these changes were not dose dependent. No histopathological lesion were observed in both control and treated animals. Above data suggest that no observed adverse effect level of test materials in rats and dogs might be over 500 IU/kg/day in this study. In ocular irritation test, any injury on iris, conjunctiva and cornea in rabbits were not observed. The acute ocular irritation index (A.O.I.), mean ocular irritation index (M.O.I.) and Day-7 individual ocular irritation Index (I.O.I.) of GC-$\gamma$ AHF were 0. In the primary skin Irritation test, the primary irritation index (P.I.I.) oj GC-$\gamma$ AHF were 0. Therefore, the GC-$\gamma$ AHF is considered not to have the primary skin and eye toxicity in rabbits. In active systemic anaphylaxis (ASA) test, GC-$\gamma$ AHF and GC-$\gamma$ AHF emulsified with Freund's complete adjuvant (FCA) did not induce any symptom of anaphylactic shock in guinea pigs. In passive cutaneous anaphylxis (PCA) test, after sensitization with antisera of GC-$\gamma$ AHF sensitized mice, blue spots were observed on the hypodermis of back of rats, but diameter of each spot was smaller than 5 mm in each test groups except the positive control group. Based on the results of this study, GC-$\gamma$ AHF is not conidered to have any antigenic potential. In conclusion, at levels of up to 500 IU/kg, GC-$\gamma$ AHF did not produce treatment-related toxicity under the conditions of these acute-, four week repeated-toxicity, primary skin and eye toxicity, and antigenicity test.

자외선 차단제의 SPF 지수와 피부자극지수와의 상관성 연구 (Studies on the Correlation between SPF Index and Skin Irritation Index of Sunscreens)

  • 김종원;서수경;최주영;박창원;서경원;김규봉;김광진;김재희;이선희
    • Biomolecules & Therapeutics
    • /
    • 제10권4호
    • /
    • pp.246-252
    • /
    • 2002
  • In recent years, the safety of sunscreens has been challenged based on the reports of their adverse effect on users; dermatitis, allergic contact dermatitis and photo allergic contact dermatitis. The unscientific idea that higher SPF sunsreen is good for health mealeads many users to tend to prefer higher SPF sunscreen. In the toxicological aspect, the need to investigate the safety of sunscreens is steadily increasing. However, there were few studies on the correlation between sun protection factor (SPF) and the safety of sunscreens. The objective of this study was to assess whether there was a correlation between SPF and the safety of sunscreens. We measured in vitro SPF index using homosalate as a standard and examined the toxicity tests such as primary skin irritation tests, ocular irritation test and skin sensitization test. Homosalate (HS), octyl methoxycinnamate (OMC), octyl salicylate (OS), octocrylene (OC) as UVB organic filter and benzophenone-3 (BP3), butyl methoxy dibenzoil methane (BMDM) as UVA organic filter, and titanium dioxide (TD), zinc oxide (ZO) as inorganic filters were used. The skin irritation indexes in rabbits treated with HS, OMC, OS, BP3, and BMDM were significantly increased as SPF indices were increased. Neither ocular irritation in rabbits nor skin sensitization in guinea pigs were increased. It suggests that there might be a good correlation between SPF and the skin irritation indices of organic UV filters and skin irritation might be one of most sensitive index to assess the safety of sunscreens.

약침용(藥鍼用) 봉독액(蜂毒液)의 국소독성시험(局所毒性試驗)에 관(關)한 연구(硏究) (A Study on Local Irritation Test of Bee Venom for Herb-Acupuncture)

  • 이종석;고형균;김창환
    • 대한한의학회지
    • /
    • 제16권1호통권29호
    • /
    • pp.227-249
    • /
    • 1995
  • Pursuant to the Medical Product Safety Administration Guidelines for safety assessment of Korean bee vonom for herb-acupuncture, rabbits were used for skin, eye balls, subcutaneous and muscle irritation test. The results were as follows; 1. The skin irritation test of bee venom for herb-acupuncture did not produce any irritation reactions, when the skin was covered with bee venom. 2. The eye irritation test produced moderate to severe stimulating reactions, once the eye mucous membrane was contacted with bee venom. 3. The subcutaneous and muscle irritation test of bee venom showed such local inflammatory reactions as death of cells, infiltration of inflamed cells, dropsical swelling, and congestion, once injected under the skin and in the muscle. As the results of the study on bee venom for herb-acupuncture indicate that severe reactions in such tests as eye balls, subcutancous and muscle irritation exist in the laboratory, more professional caution should be taken in clinical application of the therapy. In addition, further study on subacute, chronic toxicity and allergy reactions should be pursued.

  • PDF