• Title/Summary/Keyword: size range

Search Result 5,560, Processing Time 0.032 seconds

Recent Development of Differential Mobility Analyzers For Size-Classification of Nanoparticles and Their Applications to Nanotechnologies

  • Seol, Kwang-Soo;Yoshimichi Ohki;Kazuo Takeuchi
    • KIEE International Transactions on Electrophysics and Applications
    • /
    • v.4C no.2
    • /
    • pp.39-44
    • /
    • 2004
  • The present paper gives a review of the recent development of a differential mobility analyzer (DMA) available for both particle size measurements and production of monodisperse particles in the nanometer range. Operating principles of a general DMA are introduced as well as characteristics of highly functional DMAs such as those capable of classifying particles in a measurement range as broad as 1-1000nm at low pressures. Some examples of DMA applications are also described.

Optimal Range of the Step Size in LMS Adative Algorithm (LMS 적응 알고리즘의 스텝크기의 적정 범위에 관한 연구)

  • 박영철;정창경;차균현
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.18 no.2
    • /
    • pp.178-183
    • /
    • 1993
  • This paper presents a new optimal range of the step size to converge LMS adaptive algorithm considering quantization error of equalizer coefficient and excess MSE. And the simulation of transversal equalizer shows the propriety of it.

  • PDF

Feasibility study of a small linear antenna for near range wireless communications (근거리 무선 통신을 위한 소형 선형 안테나의 실현 가능성 연구)

  • 한대현;심재륜;최영식
    • Proceedings of the IEEK Conference
    • /
    • 2000.06a
    • /
    • pp.267-270
    • /
    • 2000
  • The feasibility of small linear antenna for near range wireless communications was studied. The requirement of the system are frequency range 9∼12 MHz and antenna size 15 cm. The communication range is about 15 m. The antenna input impedance is very small radiation resistance and very large capacitive reactance. The lossless impedance matching is nearly impossible, therefore lossy matching is considered. The antenna has very low radiation efficiency. The near field calculation has a large uncertainty, but the results can be used as the guideline of a small linear antenna system for a near range wireless communication.

  • PDF

The Hardware Design of Adaptive Search Range Assignment for High Performance HEVC Encoder (고성능 HEVC 부호기를 위한 적응적 탐색영역 할당 하드웨어 설계)

  • Hwang, Inhan;Ryoo, Kwangki
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2017.10a
    • /
    • pp.159-161
    • /
    • 2017
  • In this paper, we propose an adaptive search range allocation algorithm for high-performance HEVC encoder and a hardware architecture suitable for the proposed algorithm. In order to improve the prediction performance, the existing motion vector is configured with the motion vectors of the neighboring blocks as prediction vector candidates, and a search range of a predetermined size is allocated using one motion vector having a minimum difference from the current motion vector. The proposed algorithm reduces the computation time by reducing the size of the search range by assigning the size of the search range to the rectangle and octagon type according to the structure of the motion vectors for the surrounding four blocks. Moreover, by using all four motion vectors, it is possible to predict more precisely. By realizing it in a form suitable for hardware, hardware area and computation time are effectively reduced.

  • PDF

Atomization of Shear-Thinning Liquid Slurry Discharging from Fan Spray Nozzles (고형성분이 포함된 전단희석 유체의 선형(扇形) 분무노즐을 통한 미립화)

  • An, S.M.;Ryu, S.U.;Lee, S.Y.
    • Journal of ILASS-Korea
    • /
    • v.13 no.1
    • /
    • pp.42-50
    • /
    • 2008
  • In the present work, atomization characteristics of shear-thinning liquid slurry discharging from fan spray nozzles were studied experimentally for spray painting applications. The effects of solid particle size and concentration on the properties (especially on the viscosity) of suspensions and mean drop size were examined by using model fluids. In the range of low particle concentration (below 3 wt%), the fluid viscosity was primarily determined by the particle size. On the other hand, in the range of high particle concentration (higher than 10 wt%), the agglomeration phenomenon and the oil absorption capability of solid particles played major roles in determining the fluid viscosity. In the high concentration region, which most of the paints belong to, the fluid became more viscous and the shear thinning behavior appeared more prominent as the particle concentration was increased. In this region, mean drop size(SMD) decreased more rapidly with the increase of the injection pressure. Also, SMD became larger with the higher particle concentration and the larger particle size.

  • PDF

A Study on Developing the Optimal Sizing System for Ready-to-wear - Based on Elementary School Girls - (기성복의 최적 사이즈 시스템 개발을 위한 연구 - 학령기 여아를 중심으로 -)

  • Kim Ran-do;Lee Sang-youl;Kim Seon-young;Nam Yun-ja
    • Journal of the Korean Society of Clothing and Textiles
    • /
    • v.29 no.8 s.145
    • /
    • pp.1102-1113
    • /
    • 2005
  • The propose of this study is to develop the optimal sizing system of ready-to-wear f3r elementary school girls using a newly invented statistical technique. The body measurements was classified by the method that equalizes the distribution of the subjects using the probability density function, to theoretically systemize a method to determine a size range of ready-to-wear for elementary school girls between 6 to 12 years old. The statistical method were 1) The total of 11 height groups, which size interval from one another is 6 cm that is an average height gap between each age. 2) In order to determine an approximate figure (m ${\times}$ n) to establish the appropriate sizes far each height group that fit to the combinations of bust and hip girth, which based on their means and standard deviations on the probability density curve to produce the standard normal distribution. 3) m and n were aligned by 4cm -the grading increments used for patterns making- and determined the size ranges by confirming the approximate figures of m and n. 4) The representative values were determined by an area ratio calculated by dividing the area determined from the range of bust and hip girth with the representative value. Considering the characteristics of subjects' distribution, the area ratios was used. 5) Weight was calculated by seeking a growth exponent for each age and multiplying it by the number of girls that fit to each size range. As sections that show the highest weight are more likely sought by the consumers, these sections were determined as the optimal size standards. 6) This optimal sizing system consists of sizes determined by the optimal size standards and its sizes are marked with height, bust and hip girth.

A Study to define the range of sample size for setting Intensive Care Unit(ICU) facility guidelines - Focused on analysis of guidelines and present of ICUs facilities by general hospitals size (중환자실 시설기준 작성을 위한 기본시설 수준 설정 연구 - 국내·외 시설기준 및 국내 종합병원 병상규모 별 시설 현황분석을 기초로 하여)

  • Yoon, Hyung Jin;Cho, Jun Young
    • Journal of The Korea Institute of Healthcare Architecture
    • /
    • v.23 no.3
    • /
    • pp.47-56
    • /
    • 2017
  • Purpose : This study is a basic research to establish guidelines for healthcare facility in Korean healthcare market. As a first step, it is a main purpose for making beginning point of ICU guideline to set a basic level of ICU facility size and quality by analysis current ICU facilities and existed domestic guidelines : law, criteria of healthcare insurance review and assessment service, credit of Korea institute for healthcare accreditation. Methods : First of all, the all requirements of existed guidelines are put together and summarized. The summary is compared with that of US, UK, and Australia to know its quality difference with international market. In addition, all hospitals in Korean market are classified based on total bed number and ICU bed number to know the most occupied facility size range in the market. Second of all, by comparing 15 ICUs' current setting of the public general hospital, a general condition of ICU facility would be extracted based on function, floor area per bed, services Results : 72.8% of hospitals in Korea are belonging below 500 beds hospital. Among them 200-299 beds hospitals occupied 35.3% and are shown as the most occupied hospital size. As 15 public general hospitals are analyzed, it is clear that the more bed size and services the more ICU area per bed. As a result it is sure that the 300~500 bed may be a clear line as a general ICU condition whose function and bed number relatively consistent in the range. Implications : to keep the qualified medical environment and contemporary hospital trend, the guideline as a minimum requirement keep naturally out from current healthcare settings and should reflect their limit to reconcile with the new trend in the market.

Capillary Bundle Model for the Estimation of Air-water Interfacial Area and the Gas-filled Pore Size Distribution in Unsaturated Soil (모세관 모델을 이용한 불포화토양의 물-가스 접촉면적 및 가스공극 크기분포의 계산 및 검증)

  • Kim, Heonki
    • Journal of Soil and Groundwater Environment
    • /
    • v.26 no.1
    • /
    • pp.1-7
    • /
    • 2021
  • Air-water interfacial area is of great importance for the analysis of contaminant mass transfer processes occurring in the soil systems. Capillary bundle model has been proposed to estimate the specific air-water interfacial areas in unsaturated soils. In this study, the measured air-water interfacial areas of a soil (loam) using the gaseous interfacial tracer technique were compared to those from capillary bundle model. The measured values converged to the specific solid surface area (7.6×104 ㎠/㎤) of the soil. However, the simulated air-water interfacial areas based on the capillary bundle model deviated significantly from those measured. The simulated values were substantially over-estimated at low end of the water content range, whereas the model under-estimated the air-water interfacial area for the most of the water content range. This under-estimation is considered to be caused by the nature of the capillary bundle model that replaces the soil pores with a bundle of glass capillaries and thus no surface roughness at the inner surface of the capillaries is taken into account for the estimation of the air-water interfacial area with the capillary bundle model. Subsequently, appropriate correction is necessary for the capillary bundle model to estimate the air-water interfacial area in soils. Since the soil-moisture release curve data is the basis of the capillary bundle model, the model can be of use due to its simplicity, while the gaseous tracer technique requires complicated experimental equipment followed by moment analysis of the breakthrough curves. The size distribution profile of the pores filled with gas estimated by the water retention curve was found to be similar to that of particle size at different size range. The shifted distribution of gas-filled pores toward smaller size side compared to the particle size distribution was also found.

Analysis of the Process Capability Index According to the Sample Size of Multi-Measurement (다측정 표본크기에 대한 공정능력지수 분석)

  • Lee, Do-Kyung
    • Journal of Korean Society of Industrial and Systems Engineering
    • /
    • v.42 no.1
    • /
    • pp.151-157
    • /
    • 2019
  • This study is about the process capability index (PCI). In this study, we introduce several indices including the index $C_{PR}$ and present the characteristics of the $C_{PR}$ as well as its validity. The difference between the other indices and the $C_{PR}$ is the way we use to estimate the standard deviation. Calculating the index, most indices use sample standard deviation while the index $C_{PR}$ uses range R. The sample standard deviation is generally a better estimator than the range R. But in the case of the panel process, the $C_{PR}$ has more consistency than the other indices at the point of non-conforming ratio which is an important term in quality control. The reason why the $C_{PR}$ using the range has better consistency is explained by introducing the concept of 'flatness ratio'. At least one million cells are present in one panel, so we can't inspect all of them. In estimating the PCI, it is necessary to consider the inspection cost together with the consistency. Even though we want smaller sample size at the point of inspection cost, the small sample size makes the PCI unreliable. There is 'trade off' between the inspection cost and the accuracy of the PCI. Therefore, we should obtain as large a sample size as possible under the allowed inspection cost. In order for $C_{PR}$ to be used throughout the industry, it is necessary to analyze the characteristics of the $C_{PR}$. Because the $C_{PR}$ is a kind of index including subgroup concept, the analysis should be done at the point of sample size of the subgroup. We present numerical analysis results of $C_{PR}$ by the data from the random number generating method. In this study, we also show the difference between the $C_{PR}$ using the range and the $C_P$ which is a representative index using the sample standard deviation. Regression analysis was used for the numerical analysis of the sample data. In addition, residual analysis and equal variance analysis was also conducted.

A study on the Fast Block Mode Decision Algorithm for Inter Block (Inter 블록을 위한 고속 블록 모드 결정 알고리즘에 관한 연구)

  • 김용욱;허도근
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.8 no.6
    • /
    • pp.1121-1125
    • /
    • 2004
  • This paper is studied the fast block mode decision algorithm for H.264/AVC. The fast block mode decision algorithm is consist of block range decision and merge algorithm. The block range decision algorithm classifies the block over 8$\times$8 size or below for 16$\times$16 macroblock to decide the size and type of sub blocks. The block over 8$\times$8 size is divided into the blocks of 16$\times$8, 8$\times$16 and 16$\times$16 size using merging algorithm which is considered MVD(motion vector difference) of 8$\times$8 block. The sub block range decision reduces encoding arithmetic amount by 48.25% on the average more than the case not using block range decision.