• Title/Summary/Keyword: single tooth

Search Result 406, Processing Time 0.027 seconds

Comparison of the effects of horizontal and vertical micro-osteoperforations on the biological response and tooth movement in rabbits

  • Kim, Seok-gon;Kook, Yoon-Ah;Lim, Hee Jin;Park, Patrick;Lee, Won;Park, Jae Hyun;Bayome, Mohamed;Kim, Yoonji
    • The korean journal of orthodontics
    • /
    • v.51 no.5
    • /
    • pp.304-312
    • /
    • 2021
  • Objective: This study aimed to compare the amount of tooth movement after multiple horizontal (MH) and single vertical (SV) micro-osteoperforations (MOPs), and evaluate the histological changes after orthodontic force application in rabbits. Methods: The mandibles of 24 white rabbits were subjected to two experimental interventions: MH and SV MOPs. Defect volume of the MOPs between the two groups was kept similar. A force of 100 cN was applied via a coil spring between the incisor teeth and the first premolars. The amount of tooth movement was measured. Differences in the amount of tooth movement and bone variables at three time points and between the two groups were evaluated using repeated-measures analysis of variance. Results: The first premolar showed a mesial movement of 1.47 mm in the MH group and 1.84 mm in the SV group, which was significantly different at Week 3 (p < 0.05). No significant difference was observed in bone volume and bone fraction between the groups. Tartrate-resistant acidic phosphatase-positive cell count was also significantly greater at Week 3 than at Week 1 in both the SV and MH groups. Conclusions: The amount of tooth movement showed significant differences between Weeks 1 and 3 in the SV and MH MOP groups, but showed no differences between the two groups. Therefore, SV MOP could be considered an effective tool for enhancing tooth movement, especially for molar distalization, uprighting, and protraction to an edentulous area.

Absorbed and effective dose from spiral and computed tomography for the dental implant planning (치과 임프란트 치료 계획을 위한 나선형 일반 단층촬영과 전산화 단층촬영시 흡수선량 및 유효선량 평가)

  • Hong Beong-Hee;Han Won-Jeong;Kim Eun-Kyung
    • Imaging Science in Dentistry
    • /
    • v.31 no.3
    • /
    • pp.165-173
    • /
    • 2001
  • Objectives : To evaluate the absorbed and effective doses of spiral and computed tomography for the dental implant planning. Materials and Methods: For radiographic projection, TLD chips were placed in 22 sites of humanoid phantom to record the exposure to skin and the mean absorbed dose to bone marrow, thyroid, pituitary, parotid and submandibular glands and nesophagus. Effective dose was calculated, using the method suggested by Frederiksen et al.. Patient situations of a single tooth gap in upper and lower midline region, edentulous maxilla and mandible were simulated for spiral tomography. 35 axial slices (maxilla) and 40 axial slices (mandible) with low and standard dose setting were used for computed tomography. All the radiographic procedures were repeated three times. Results: The mean effective dose in case of maxilla was 0.865 mSv, 0.452 mSv, 0.136 mSv and 0.025 mSv, in spiral tomography of complete edentulous maxilla, computed tomography with standard mAs, computed tomography with low mAs and spiral tomography of a single tooth gap (p<0.05). That in case of mandible was 0.614 mSv, 0.448 mSv, 0.137 mSv and 0.036 mSv, in spiral tomography of complete edentulous mandible, computed tomography with standard mAs, computed tomography with low mAs and spiral tomography of a single tooth gap (p<0.05). Conclusions: Based on these results, it can be concluded that low mAs computed tomography is recommended instead of spiral tomography for the complete edentulous maxilla and mandible dental implant treatment planning.

  • PDF

A Study on the Vibration Characteristics of Helical Gears with Tooth Errors (치형오차를 가진 헬리컬기어의 진동특성에 관한 연구)

  • Park, Chan-Il;Lee, Jang-Moo
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.20 no.5
    • /
    • pp.1534-1542
    • /
    • 1996
  • Gear vibration is caused by the mesh stiffness, gear accuracy, and assembling errors. For these reasons, helical gear has the azial, radial, and rotational vibrations. In this study, the mesh stiffness is calculated by considering the tooth bending, contact, and foundation deformations. Rotational vibration of helical gear with tooth error is modeled by the nonlidear equation of motion with single degree of freedom and is anlyzed numerically. Also, by a specially designed experimental set-up, the analysis are cross-checked and the vibration characteristics of helical gear are discussed.

A Retrospective study on $Br{\aa}nemark$ $TiUnite^{(R)}$ implant for mandibular posterior single tooth replacement (하악 구치부에서 $Br{\aa}nemark$$TiUnite^{(R)}$ implant를 이용한 단일 치아수복의 후향적 연구)

  • Oh, Kyung-Choon;Chae, Gyung-Joon;Jung, Ui-Won;Kim, Chang-Sung;Cho, Kyoo-Sung;Choi, Seong-Ho;Kim, Chong-Kwan;Chai, Jung-Kiu
    • Journal of Periodontal and Implant Science
    • /
    • v.37 no.4
    • /
    • pp.705-718
    • /
    • 2007
  • The purpose of this study was to evaluate 6 years cumulative survival rate (CSR, %) of mandibular posterior single tooth implants replaced with $Br{\aa}nemark$ $TiUnite^{(R)}$ implant system. The findings from this study were as followed ; 1. The 112 (111 persons) single implants that were placed in the mandibular posterior region were successful except 4 cases and showed 96.42% CSR. 2. The 55 (55 persons) single implants that were placed in the mandibular first molar region were successful except 2 cases and showed 96.36% survival rate. And, among the 57 (56 persons) single implants replacing the mandibular second molar. 2. failed showing 96.49% survival rate. There was no significant statistical difference. 3. Among the total 112 implants, 5.0mm wide diameter implants were placed in 96 cases(85.7%) showing 96.9% survival rate. 4.0mm standard diameter implants were placed in 16 cases showing 93.8% survival rate. There was no significant statistical difference. 4. Long implants above 10.0mm length were placed 103 cases(91.0%) and showed 96.1% survival rate. Short implants within 8.5mm length were placed 9 cases and showed 100% survival rate. There was no significant statistical difference. 5. 37 implants placed in type I, II bone quality were showed higher survival rate(100%) than that of 52 implants placed in type III, IV bone quality(92.3%). But, there was no significant statistical difference. In conclusion, $Br{\aa}nemark$ $TiUnite^{(R)}$ implant showed successful results when replacing manbibular single molar.

Retrospective study on ITI SLA (sand-blasted, large-grit, acid-etched) implant for mandibular posterior single tooth replacement (하악 구치부에서 ITI SLA (Sand-blasted, Large-grit, Acid-etched) 임플란트를 이용한 단일 치아 수복의 후향적 임상 연구)

  • Lee, Seung-Mun;Chae, Gyung-Joon;Jung, Ui-Won;Kim, Chang-Sung;Choi, Seong-Ho;Cho, Kyoo-Sung;Kim, Chong-Kwan;Chai, Jung-Kyu
    • Journal of Periodontal and Implant Science
    • /
    • v.36 no.3
    • /
    • pp.661-671
    • /
    • 2006
  • The purpose of this study was to evaluate cumulative survival rate (CSR, %) of mandibular posterior single tooth implants replaced with ITI SLA (sand-blasted, large-grit, acid-etched) implant system and compare the CSR between first and second molar. The findings from the results were as follows; 1. Total of 158 implants were inserted into 147 patients. 68 patients were males, 79 patients were females and their mean age was 47.8 years. 98 implants were placed in first molar area and 60 implants were placed in second molar area. In terms of diameter, implants with wide diameter over 4.8mm dominated (91.1%). Implants with length over lOmm were used (96.2%). 2, In the two cases, there was a slight transient numbness which recovered within 1-2 months. Nine SynOcta screw type abutments demonstrated screw loosening, There were ten cases of crown fallen-out from decementation. 3. Only one failed out of 158 implants. The CSR was 99.4%. The CSRs for first molar and second molar were 99% and 100%, respectively. From the results, it was concluded that single tooth replacement implant in the mandibular posterior area, might be considered as the effective treatment modality comparable to the conventional crown and bridge.

A 3 year-retrospective study of survival rate in single $Br{\aa}nemark$ $TiUnite^{TM}$ implant (단일치아 결손시 $TiUnite^{TM}$ 표면처리한 임플란트의 생존율에 대한 후향적 단기연구)

  • Yang, Seung-Min;Park, Sun-Hye;Shin, Seung-Yun;Kye, Seung-Beom
    • Journal of Periodontal and Implant Science
    • /
    • v.37 no.4
    • /
    • pp.671-679
    • /
    • 2007
  • Background: $TiUnite^{TM}$ is a highly crystalline and phosphate enriched titanium oxide surface which has a unique porous surface structure. This improved implant surface enhances bone response and reduces healing period. It also assures early stability of implant. These help to increase the success of implant. The aim of this study is to evaluate the survival rate of $TiUnite^{TM}$ surfaced single implant. Materials and methods: A retrospective analysis of 89 $TiUnite^{TM}$ surfaced implants replacing a single tooth was assessed according to their dental record. The age of the patients ranged from 17 to 82 years (mean age: $45.8{\pm}14.6)$. Data were recorded regarding the survival rate of these implants. Results: Fifty-two implants (57%) were placed in the maxilla, and 37 (43%) in the mandible. Over 75% were placed in the posterior area. Of the placed implants, 67% were the wide type. while 25% were the regular type and only 8% were of the narrow type. The single implants produced an overall clinical survival rate of 96.6% over the observation period (mean 17.9 months). Among 89 implants, only 2 implants were removed and one implant was submerged. Conclusion: According to these data, $TiUnite^{TM}$ surfaced implant in a single tooth restoration showed favorable survival rate although this study was done in a short term period.

Analytical Prediction of Transmission Error and Load Distribution for a Plugin HEV (플러그인 HEV용 변속기전달오차와 하중분포에 관한 연구)

  • Zhang, Qi;Kang, Jae-Hwa;Yun, Gi-Baek;Lyu, Sung-Ki
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.11 no.3
    • /
    • pp.116-121
    • /
    • 2012
  • In recent years, world is faced with a transportation energy dilemma, and the transportation is dependent on a single fuel - petroleum. However, Hybrid Electric Vehicle(HEV) technology holds more advantages to reduce the demand for petroleum in the transportation by efficiency improvements of petroleum consumption. Therefore, there is a trend that lower gear noise levels are demanded in HEV for drivers to avoid annoyance and fatigue during operation. And meshing transmission error(T.E.) is the excitation that leads to the tonal noise known as gear whine, and radiated gear whine is also the dominant source of noise in the whole gearbox. This paper presents a method for the analysis of gear tooth profile and lead modification, and the predictions of transmission error and load distribution are shown under one loaded torque for the 1st gear pair of HEV gearbox. The test is also obtained before tooth micro-modification under the torque. At last, the appropriate tooth modification is used to minimize the transmission error and load distribution under the loaded torque. It is a good approach which the simulated result is used to improve the design in order to minimize the radiation gear whine noise.

A STUDY HO THE PREDICTION OF DURATION OF ORTHODONTIC TREATMENT IN MALOCCLUSION (부정교합 치료기간의 예측에 관한 연구)

  • Kim, Hyuk-Jae;Lee, Dong-Joo
    • The korean journal of orthodontics
    • /
    • v.18 no.1 s.25
    • /
    • pp.105-112
    • /
    • 1988
  • To predict duration of orthodontic treatment of malocclusion, 304 male and female patients whose orthodontic treatment was finished in department of orthodontics, Infirmary of dental college, Chosun University were studied. The duration of treatment was studied according to types of malocclusion, beginning ages of treatment, Hellman's dental ages, the determination of tooth extraction, types of tooth extraction and types of orthodontic appliance. The following results were obtained. 1. The duration of treatment was 18 months in Class I malocclusion, 20 months in Class II malocclusion and 24 months in Class III malocclusion. 2. The more early treatment was done, the more duration of treatment was needed according to beginning age of treatment and Hellman's dental ages. 3. Treatment of tooth extraction case was needed for 78 days more than that of non-extraction case. 4. The duration of treatment with unilateral extraction of premolars was the shortest (598 days) and that with single arch extraction of premolars was the longest (685 days) according to types of tooth extraction. 5. The duration of treatment by removable appliance was the shortest (237 days) and the combination of removable appliance, headgear and full banded appliance was the longest (1425 days) according to types of orthodontic appliance. 6. The duration of treatment was 18 months in typical orthodontic treatment with 4 extraction of premolar and full banded appliance.

  • PDF

Role of cone-beam computed tomography in the evaluation of a paradental cyst related to the fusion of a wisdom tooth with a paramolar: A rare case report

  • Ozcan, Gozde;Sekerci, Ahmet Ercan;Soylu, Emrah;Nazlim, Sinan;Amuk, Mehmet;Avci, Fatma
    • Imaging Science in Dentistry
    • /
    • v.46 no.1
    • /
    • pp.57-62
    • /
    • 2016
  • Fusion is an abnormality of tooth development defined as the union of two developing dental germs, resulting in a single large dental structure. This irregular tooth morphology is associated with a high predisposition to dental caries and periodontal diseases. As a result of recurring inflammatory periodontal processes, disorders such as periodontal pocket, pericoronitis, and paradental cysts may develop. A rare mandibular anatomic variation is the retromolar canal, which is very significant for surgical procedures. The fusion of a paramolar and mandibular third molar associated with a paradental cyst co-occurring with the presence of a retromolar canal is rare, and the aim of the present study is to describe the evaluation of this anatomical configuration using cone-beam computed tomography.

Achievement of Anterior Teeth Arrangement Using a Single Stage of Clear Aligner

  • Ryu, Seon-Jeong;Choi, Sung-Hwan;Cha, Jung-Yul;Hwang, Chung-Ju
    • Journal of Korean Dental Science
    • /
    • v.14 no.2
    • /
    • pp.90-100
    • /
    • 2021
  • Purpose: The aim of this study was to evaluate the degree of achievement of anterior tooth movement using a thermoplastic clear aligner by superimposing pretreatment, setup, and post-treatment models and to analyze the factors that influence it. Materials and Methods: Forty patients who underwent clear aligner treatment at the Department of Orthodontics were included in the study. The pretreatment, setup, and post-treatment models were superimposed, and the achievement rates were evaluated. We analyzed the factors that caused changes in achievement rate on each condition. Result: The average achievement rate of total tooth movement was 57.65%. Mesiodistal and anteroposterior displacements were achieved better than vertical displacement and rotation. In each displacement, posterior, mesial, and extrusive movements were better achieved than the rotation. Spacing was better corrected than crowding, especially in the mesiodistal direction. Most of the tooth movements were achieved better when using 3-step thicknesses of aligners were used. Conclusion: The treatment results of clear aligners may differ depending on the type of tooth movement, age and other treatment conditions. Clinicians should consider unfavorable conditions based on the results of this study.