• Title/Summary/Keyword: single pulse

Search Result 828, Processing Time 0.032 seconds

Two Unresolved Target Angle Estimation in Phase Comparison Monopulse Radar (위상비교모노펄스를 이용한 근접한 두 표적 분리에 관한 연구)

  • Lee, Seung-Phil;Cho, Byung-Lae;Kim, Young-Soo
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.27 no.6
    • /
    • pp.539-544
    • /
    • 2016
  • This paper improves Sherman's two-pulse method for angle estimation of two unresolved targets in phase comparison monopulse radar. The proposed method provides the angle information with only a single-pulse measurement instead of two pulses. The proposed method can estimate a single-target angle by single-target indicator, in contrast with previous techniques. The accuracy of angle estimation for proposed method is demonstrated by simulations.

옥외 LED 조명을 위한 넓은 출력 전력 범위을 갖는 인터리빙 방식의 단일 전력 Flyback AC-DC Converter

  • Mun, Sang-Cheol;Gu, Gwan-Bon;Mun, Geon-U
    • Proceedings of the KIPE Conference
    • /
    • 2012.07a
    • /
    • pp.191-192
    • /
    • 2012
  • 옥외 LED 조명은 수 많은 응용 분야가 있고, 출력 전력 크기에 따라 전력단이 single-stage 와 two-stage 구조로 나뉜다. Single-stage 구조는 낮은 전력 LED 조명에 적합하지만, 60~70W 이상에서는 효율이 떨어지고 변압기의 크기가 커져서 적용하기가 힘들다. 반면에 two-stage 구조는 보통 큰 전력이 필요한 응용분야에 사용되지만, 낮은 부하에서 낮은 역율을 나타내므로 넓은 출력전력 범위를 갖는 분야에 사용되기 어렵다. 이 문제를 해결하기 위하여 본 논문은 pulse duty cycle, pulse frequency modulation 제어 방법을 갖는 interleaved single-stage flyback AC-DC converter 를 제안한다. 제안된 컨버터는 입력 전압이 낮고 부하가 큰 경우 높은 효율을 보이고, 입력 전압이 높고 부하가 아주 작은 경우에도 높은 역율과 낮은 전류 왜곡을 보인다. 그 결과 하나의 AC-DC 컨버터를 넓은 출력전력 범위를 갖는 LED 조명분야 적용시킬 수 있다. 제안된 컨버터의 타당성을 검증하기 위하여 81W prototype을 가지고 실험하였다.

  • PDF

Orientation dependence of GM-type pulse tube refrigerator (GM형 맥동관 냉동기의 저온부 경사도에 따른 냉각 성능 특성 연구)

  • Ko, Jun-Seok;Kim, Hyo-Bong;Park, Seong-Je;Hong, Yong-Ju;Yeom, Han-Kil;Lee, Chung-Soo;Kang, In-Su;Koh, Deuk-Yong
    • Progress in Superconductivity and Cryogenics
    • /
    • v.14 no.3
    • /
    • pp.48-52
    • /
    • 2012
  • This paper describes experimental study on the orientation dependence of GM-type pulse tube refrigerator with helium and neon as working gas. A pulse tube refrigerator generates refrigeration work with gas expansion by gas displacer in the pulse tube. The pulse tube is only filled with working gas and there exists secondary flow due to large temperature difference between cold-end and warm-end. The stability of secondary flow is affected by orientation of cold-head and thus cooling performance is deteriorated by gas mixing due to secondary flow. In this study, a single stage GM-type pulse tube with orifice valve as a phase control device is fabricated and tested. The fabricated pulse tube refrigerator is tested with two different working gases of helium and neon. First, optimal valve opening and operating frequency are determined with experimental results of no-load test. And then, the variation of no-load temperature as orientation angle of cold-head is measured for two different working gases. Effect of orientation dependence of cold-head as working gas is discussed with experimental results.

Experimental Studies on the interaction of Kangsimsan and Hydralazine, Verapamil, Clonidine, Hydrochlorothiazide and Furosemide (고혈압(高血壓)에 강심산(强心散)과 Hydralazine, Clonidine, Hydrochlorothiazide 및 Furosemide의 병용투여(倂用投與)에 관한 실험적(實驗的) 연구(硏究))

  • Kim, Jin-Don;Cho, Ki-Ho;Kim, Young-Suk;Bae, Hyung-Sup;Lee, Kyung-Sup
    • The Journal of Korean Medicine
    • /
    • v.15 no.2 s.28
    • /
    • pp.198-211
    • /
    • 1994
  • After giuing some anti-high blood pressure medicine of boiled-compressed fluid and 5-Kinds factors(Hydralazine, Verapamil, Clonidine, Furosemide and Hydrochlorothiazide with Kangsimsan to animals in single or together. I got the following conclusion in comparing blood-pressure and pulse of circulating system with urinating operation. 1. By joint-use of Kangsimsan and Hydralazine. it was found out that the effect of blood-pressure lowering continues longer in together-use than in single. And I coule see that the number of pulse increased. 2. By joint-use of Kangsimsan and Verapamil. the blood-pressure lowering operation was kept better in together-use than in single. the number of pulse was not affected any. 3. By joint-use of Kangsimsan and Clonidine the blood-pressure lowering operation was not found out any concrete result. 4. By joint-use of Kangsimsan and Furosemide. the Remarkble effect of Urinization was recognized to be much better in joint-use than in single. 5. By joint-use of Kangsimsan and Hydrochlorothiazide. the suppressing effect of urinization was recognized to be much better in joint-use than in single. Therefore in consideration of the above study and observation. when the joint-use of Kangsimsan and the blood-pressure lowering medicine. Hydralazine and Verapamil. the period of blood-pressure lowering was kept and I can conclude that in case of joint-use of Furosemide, a kind of good urinization. the effect of urinization by Furosemide is increased, but that of Hydrochlorothiazide is disturbed.

  • PDF

Designing Optimal Pulse-Shapers for Ultra-Wideband Radios

  • Luo, Xiliang;Yang , Liuqing;Giannakis, Georgios-B.
    • Journal of Communications and Networks
    • /
    • v.5 no.4
    • /
    • pp.344-353
    • /
    • 2003
  • Ultra-wideband (UWB) technology is gaining increasing interest for its potential application to short-range indoor wireless communications. Utilizing ultra-short pulses, UWB baseband transmissions enable rich multipath diversity, and can be demodulated with low complexity receivers. Compliance with the FCC spectral mask, and interference avoidance to, and from, co-existing narrow-band services, calls for judicious design of UWB pulse shapers. This paper introduces pulse shaper designs for UWB radios, which optimally utilize the bandwidth and power allowed by the FCC spectral mask. The resulting baseband UWB systems can be either single-band, or, multi-band. More important, the novel pulse shapers can support dynamic avoidance of narrow-band interference, as well as efficient implementation of fast frequency hopping, without invoking analog carriers.

Considerations on the TF Anal,ysis using Partial Discharge Pulse Characteristics in Oil (유중 부분방전 펄스 특성을 이용한 TF 분석에 대한 고찰)

  • Kim, Jeong-Tae
    • The Transactions of the Korean Institute of Electrical Engineers C
    • /
    • v.54 no.11
    • /
    • pp.508-514
    • /
    • 2005
  • In this paper, it was investigated the characteristics of PD(partial discharge) pulse shapes in oil and the possibility of TF(Time-Frequency) analysis for the discrimination of air corona in on-site PD measurement of oil transformers. For the purpose, single and multiple discharges combined with oil discharges and air corona were generated and measured by use of artificial models through the HFPD pulse detector and the oscilloscope. PD pulse shapes were different according to the type of defects, especially including air corona- pulses. Also, through the TF analysis, data clusters could be classified each other in the TF Map, even in the case of multiple discharges. Therefore, it is known that TF analysis could be aprlied for the improvement of on-site PD measurement in oil transformers.

Ultra-low-power Pulse Oximeter with a 32.768 kHz Real Clock

  • Lee, Wonjun;Han, Youngsun;Kim, Chulwoo;Rieh, Jae-sung;Park, Jongsun;Park, Jae Young;Kim, Seon Wook
    • IEIE Transactions on Smart Processing and Computing
    • /
    • v.6 no.2
    • /
    • pp.129-132
    • /
    • 2017
  • A conventional pulse oximeter has high power consumption; thus, its mobility is severely limited. In this paper, we discuss the drawbacks of the existing pulse oximeters and propose a new ultra-low-power pulse oximeter that supports wireless data transmission for remotely monitoring vital signs, such as peripheral capillary oxygen saturation (SpO2) and beats per minute (BPM). We could notably reduce power consumption by using a low-frequency single clock in all well-customized modules. Also, our device is publicly certified, and thus, possibly engaged in clinical trials for commercial use.

Crystal Structure, Microstructure and Mechanical Properties of NbN Coatings Deposited by Asymmetric Bipolar Pulsed DC Sputtering

  • Chun, Sung-Yong;Im, Hyun-Ho
    • Journal of the Korean Ceramic Society
    • /
    • v.54 no.1
    • /
    • pp.33-37
    • /
    • 2017
  • Single phase niobium nitride (NbN) coatings were deposited using asymmetric bipolar pulsed dc sputtering by varying pulse frequency and duty cycle of pulsed plasmas. Crystal structure, microstructure, morphology and mechanical properties were examined using XRD, FE-SEM, AFM and nanoindentation. Upon increasing pulse frequencies and decreasing duty cycles, the coating morphology was changed from a pyramidal-shaped columnar structure to a round-shaped dense structure with finer grains. Asymmetric bipolar pulsed dc sputtered NbN coatings deposited at pulse frequency of 25 kHz is characterized by higher hardness up to 17.4 GPa, elastic modulus up to 193.9 GPa, residual compressive stress and a smaller grain size down to 27.5 nm compared with dc sputtered NbN coatings at pulse frequency of 0 kHz. The results suggest that the asymmetric bipolar pulsed dc sputtering technique is very beneficial to reactive deposition of transition-metal nitrides such as NbN coatings.

Efficiency Improvement of Pulsed Nd:YAG Laser using Pulse Superposition Technique (펄스중첩기술을 적용한 펄스형 Nd:YAG 레이저의 효율개선)

  • Kwak, B.G.;Jung, J.H.;Lee, D.H.;Hong, J.H.;Kim, H.J.;Cho, J.S.
    • Proceedings of the KIEE Conference
    • /
    • 1997.07e
    • /
    • pp.1864-1866
    • /
    • 1997
  • In this study, we designed the pulse superposition network consisting of a six-mesh and a three-mesh network, and fabricated the electrical power supply and the single elliptical resonator. We have developed a tec.bnique forming the step-pulse shape of pulsed Nd:YAG laser by using one shot multivibrater and have studied on the effect of two pulses superposition for the output and efficiency improvement of pulsed Nd:YAG laser by superposing a sinusoidal pulse on a main pulse.

  • PDF

A development of low frequency electrical nerve stimulator for muscle care and diet (저주파를 이용한 신경자극 치료장치 개발)

  • 정영수;현웅근
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2002.11a
    • /
    • pp.462-466
    • /
    • 2002
  • This paper describes a low frequency electrical nerve stimulator for muscle care. The developed system consist of 8bit low power consumed MPU, voltage boosting circuit converting 9V input to 120V output, repairing circuit for distorted output pulse, LED and buttons for I/O, and electro-chemical pad. The pulse generation algorithm for the muscle care effect is developed with basic pulses such as a single phase rectangle pulse, symmetric rectangle pulse, and depolarized interrupt pulse.

  • PDF