• 제목/요약/키워드: single current sensor

검색결과 227건 처리시간 0.03초

지중선로의 분포 온도 측정 시스템 개발 (Development of optical temperature distribution measurement system for Underground Power Transmission tunnel)

  • 이근양;송우성
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1998년도 하계학술대회 논문집 B
    • /
    • pp.766-768
    • /
    • 1998
  • Optical Temperature Distribution measurement System (OTDS) is completely different from conventional electric point sensor in that it uses the optical fiber itself as the sensor. This new concept in temperature measuring system requires only one fiber to be laid. The use of optical fiber also gives the advantage of small diameter, light weight, explosion resistance, and electromagnetic noise resistance. The OTDS is a sensor which is capable of making a precise measurement over a wide range of areas using only a single optical fiber. Since current temperature sensors, such as the thermocouple, are only used to measure temperaturea of point, they are almost impractical for measuring a wider range because of the extremely high cost. In comparision with current sensors, the optical fiber distributed temperature sensor can make much quicker and more precise measurements at a comparatively low cost.

  • PDF

Load Disturbance Compensation for Stand-alone Inverters Using an Inductor Current Observer

  • Choe, Jung-Muk;Moon, Seungryul;Byen, Byeng-Joo;Lai, Jih-Sheng;Lim, Young-Bae;Choe, Gyu-Ha
    • Journal of Power Electronics
    • /
    • 제17권2호
    • /
    • pp.389-397
    • /
    • 2017
  • A control scheme for stand-alone inverters that utilizes an inductor current observer (ICO) is proposed. The proposed method measures disturbance load currents using a current sensor and it estimates the inductor current using the ICO. The filter parameter mismatch effect is analyzed to confirm the ICO's controllability. The ICO and controllers are designed in a continuous-time domain and transferred to a discrete-time domain with a digital delay. Experimental results demonstrate the effectiveness of the ICO using a 5-kVA single-phase stand-alone inverter prototype. The experimental results demonstrate that the observed current matches the actual current and that the proposed method can archive a less than 2.4% total harmonic distortion (THD) sinusoidal output waveform under nonlinear load conditions.

Continuous Human Activity Detection Using Multiple Smart Wearable Devices in IoT Environments

  • Alshamrani, Adel
    • International Journal of Computer Science & Network Security
    • /
    • 제21권2호
    • /
    • pp.221-228
    • /
    • 2021
  • Recent improvements on the quality, fidelity and availability of biometric data have led to effective human physical activity detection (HPAD) in real time which adds significant value to applications such as human behavior identification, healthcare monitoring, and user authentication. Current approaches usually use machine-learning techniques for human physical activity recognition based on the data collected from wearable accelerometer sensor from a single wearable smart device on the user. However, collecting data from a single wearable smart device may not provide the complete user activity data as it is usually attached to only single part of the user's body. In addition, in case of the absence of the single sensor, then no data can be collected. Hence, in this paper, a continuous HPAD will be presented to effectively perform user activity detection with mobile service infrastructure using multiple wearable smart devices, namely smartphone and smartwatch placed in various locations on user's body for more accurate HPAD. A case study on a comprehensive dataset of classified human physical activities with our HAPD approach shows substantial improvement in HPAD accuracy.

단상 액티브 파워 필터를 위한 새로운 전류 보상 방법 (A New Current Compensation Estimation Method For Single Phase Active Power Filter)

  • 곽상신;이무영
    • 대한전자공학회:학술대회논문집
    • /
    • 대한전자공학회 1998년도 추계종합학술대회 논문집
    • /
    • pp.819-822
    • /
    • 1998
  • A new active power filter (APF) circuit with a current compesation estimation method is proposed. The current compensation estimation method replaces a current sensor with an estimating circuit and therefore reduces the implementation cost In addition, a simple control scheme, based on the energy balance concept, is adopted to control the voltage of a DC capacitor. Therefore energy change in the DC capacitor can be compensanted in the next cycle. Since a sampling technique is used, a larger DC capacitor voltage ripple can be permissible and a relatively smaller DC capacitor can be used. The proposed method has advantages of the reduction of one current sensor, low implementation cost, and fast transient responses. The theoretical analysis and simulation results are given. The proposed control method is successfully verified by computer simulation.

  • PDF

A Single-Input Single-Output Approach by using Minor-Loop Voltage Feedback Compensation with Modified SPWM Technique for Three-Phase AC-DC Buck Converter

  • Alias, Azrita;Rahim, Nasrudin Abd.;Hussain, Mohamed Azlan
    • Journal of Power Electronics
    • /
    • 제13권5호
    • /
    • pp.829-840
    • /
    • 2013
  • The modified sinusoidal pulse-width modulation (SPWM) is one of the PWM techniques used in three-phase AC-DC buck converters. The modified SPWM works without the current sensor (the converter is current sensorless), improves production of sinusoidal AC current, enables obtainment of near-unity power factor, and controls output voltage through modulation gain (ranging from 0 to 1). The main problem of the modified SPWM is the huge starting current and voltage (during transient) that results from a large step change from the reference voltage. When the load changes, the output voltage significantly drops (through switching losses and non-ideal converter elements). The single-input single-output (SISO) approach with minor-loop voltage feedback controller presented here overcomes this problem. This approach is created on a theoretical linear model and verified by discrete-model simulation on MATLAB/Simulink. The capability and effectiveness of the SISO approach in compensating start-up current/voltage and in achieving zero steady-state error were tested for transient cases with step-changed load and step-changed reference voltage for linear and non-linear loads. Tests were done to analyze the transient performance against various controller gains. An experiment prototype was also developed for verification.

저전력 Single-Slope ADC를 사용한 CMOS 이미지 센서의 설계 (Design of a CMOS Image Sensor Based on a Low Power Single-Slope ADC)

  • 권혁빈;김대윤;송민규
    • 대한전자공학회논문지SD
    • /
    • 제48권2호
    • /
    • pp.20-27
    • /
    • 2011
  • 모바일 기기에 장착되는 CMOS 이미지 센서(CIS) 칩은 배터리 용량의 한계로 인해 저전력 소모를 요구한다. 본 논문에서는 전력소모를 줄일 수 있는 데이터 플립플롭 회로와 새로운 저전력 구조의 Single-Slope A/D Converter(SS-ADC)를 사용한 이미지 센서를 설계하여 모바일 기기에 사용되는 CIS 칩의 전력 소모를 감소시켰다. 제안하는 CIS는 $2.25um{\times}2.25um$ 면적을 갖는 4-Tr Active Pixel Sensor 구조를 사용하여 QVGA($320{\times}240$)급 해상도를 갖도록 설계되었으며 0.13um CMOS 공정에서 설계되었다. 실험 결과, CIS 칩 내부의 SS-ADC 는 10-b 해상도를 가지며, 동작속도는 16 frame/s 를 만족하였고, 전원 전압 3.3V(아날로그)/1.8V(Digital)에서 25mW의 전력 소모를 보였다. 측정결과로부터 제안된 CIS 칩은 기존 CIS 칩에 비해 대기시간동안 약 22%, 동작시간동안 약 20%의 전력이 감소되었다.

EPB 시스템의 센서 고장 허용 제어 기법 (Fault Tolerant Control of Sensor Fault of EPB System)

  • 이원구;이영옥;장민석;이충우;정정주;정한별
    • 한국자동차공학회논문집
    • /
    • 제18권4호
    • /
    • pp.8-17
    • /
    • 2010
  • In this paper, a fault tolerant control against sensor faults of electric parking brake (EPB) is proposed. Fault tolerant control method of EPB system is strongly demanded since sensor faults can endanger a driver's safety. In this paper, a clamp force estimation method is presented using motor's armature current and angular velocity. Clamp force estimation method is applied for fault detection method with parity equations. The goal of the detection method is to detect and identify faults in encoder, current sensor, force sensor, and parking cable. And a switching logic for fault tolerant control against the three sensor faults is suggested. Experimental results show that the proposed force estimation method satisfies the specifications of EPB system. The effectiveness of the fault detection method is validated with experimental results. Although a single sensor fault happens, EPB system with the proposed fault detection method does not develop into a failure on subsystem or system level.

Design of a 25 mW 16 frame/s 10-bit Low Power CMOS Image Sensor for Mobile Appliances

  • Kim, Dae-Yun;Song, Min-Kyu
    • JSTS:Journal of Semiconductor Technology and Science
    • /
    • 제11권2호
    • /
    • pp.104-110
    • /
    • 2011
  • A CMOS Image Sensor (CIS) mounted on mobile appliances requires low power consumption due to limitations of the battery life cycle. In order to reduce the power consumption of CIS, we propose novel power reduction techniques such as a data flip-flop circuit with leakage current elimination and a low power single slope analog-to-digital (A/D) converter with a sleep-mode comparator. Based on 0.13 ${\mu}m$ CMOS process, the chip satisfies QVGA resolution (320 ${\times}$ 240 pixels) that the cell pitch is 2.25 um and the structure is a 4-Tr active pixel sensor. From the experimental results, the performance of the CIS has a 10-b resolution, the operating speed of the CIS is 16 frame/s, and the power dissipation is 25 mW at a 3.3 V(analog)/1.8 V(digital) power supply. When we compare the proposed CIS with conventional ones, the power consumption was reduced by approximately 22% in the sleep mode, and 20% in the active mode.

단상 영구자석 동기전동기의 속도 가변형 비례공진 전류제어에 관한 연구 (A Study on Speed Variable Proportional Resonant Current Controller of Single-Phase PMSM)

  • 이원석;황선환;박종원
    • 전기전자학회논문지
    • /
    • 제24권4호
    • /
    • pp.954-960
    • /
    • 2020
  • 본 논문은 단상 영구자석 동기전동기의 속도 가변형 비례공진 전류제어 기법을 제안한다. 단상 영구자석 동기전동기는 전자기적 특성상 고정자 전류와 역기전력의 위상차에 따른 부토크 및 영토크가 발생하며 센서리스 운전 시 낮은 고정자 저항과 인덕턴스로 인해 과전류 제한이 필요하다. 이러한 조건하에서 전류제어를 위해 3상 교류 전동기에 사용되는 벡터 제어를 이용할 경우, 좌표변환, 역좌표변환 및 가상의 dq축 성분을 생성하는 과정이 필요하다. 하지만, 단상 영구자석 동기전동기의 자기적 특성을 고려하여 제안한 속도 가변형 비례공진 전류제어 기법은 3상 교류 전동기에 사용되는 좌표변환 과정이 필요하지 않다. 본 논문에서는 가변 비례공진 전류제어 기법을 이용하여 안정적인 기동 성능을 확인하며 일정 속도 도달 시 위치 센서 없이 단상 영구자석 동기전동기의 수학적 모델 기반 센서리스 제어로 제안한 전류제어 기법의 효용성을 다수의 실험을 통해 검증하였다.

Low-Voltage Current-Sensing CMOS Interface Circuit for Piezo-Resistive Pressure Sensor

  • Thanachayanont, Apinunt;Sangtong, Suttisak
    • ETRI Journal
    • /
    • 제29권1호
    • /
    • pp.70-78
    • /
    • 2007
  • A new low-voltage CMOS interface circuit with digital output for piezo-resistive transducer is proposed. An input current sensing configuration is used to detect change in piezo-resistance due to applied pressure and to allow low-voltage circuit operation. A simple 1-bit first-order delta-sigma modulator is used to produce an output digital bitstream. The proposed interface circuit is realized in a 0.35 ${\mu}m$ CMOS technology and draws less than 200 ${\mu}A$ from a single 1.5 V power supply voltage. Simulation results show that the circuit can achieve an equivalent output resolution of 9.67 bits with less than 0.23% non-linearity error.

  • PDF