• 제목/요약/키워드: single capacitor

검색결과 491건 처리시간 0.035초

Zigbee 무선통신을 이용한 UPS DC링크 커패시터의 고장 모니터링 시스템 개발 (A development of Diagnosis Monitoring System for UPS DC Link Capacitors using Zigbee Wireless Communication)

  • 김동준;손진근;전희종
    • 전기학회논문지P
    • /
    • 제61권1호
    • /
    • pp.41-46
    • /
    • 2012
  • Electrolytic power capacitors have been widely used in power conversion system such as inverter or UPS because of characteristics of large capacitance, high-voltage and low-cost. The electrolytic capacitor, which is most of the time affected by the aging effect, plays a very important role for the power-electronics system quality and reliability. Therefore it is important to diagnosis monitoring the condition of an electrolytic capacitor in real-time to predict the failure. In this paper, the on-line remote diagnosis monitoring system for UPS DC link electrolytic capacitors using low-cost single-chip zigbee communication modules is developed. To estimate the health status of the capacitor, the equivalent series resistor(ESR) of the component has to be determined. The capacitor ESR is estimated by using RMS computation using BPF modeling of DC link ripple voltage/current. Zigbee-based hardware experimental results show that the proposed remote capacitor diagnosis monitoring system can be applied to UPS successfully.

마이크로그리드 전력변환장치용 커패시터 고장 검출 기법 (Capacitor Failure Detection Technique for Microgrid Power Converter)

  • 이우현;송광철;안준재;박성미;박성준
    • 한국산업융합학회 논문집
    • /
    • 제26권6_2호
    • /
    • pp.1117-1125
    • /
    • 2023
  • The DC part of the DC microgrid power conversion system uses capacitors for buffers of charge and discharge energy for smoothing voltage and plays important roles such as high frequency component absorption, power balancing, and voltage ripple reduction. The capacitor uses an aluminum electrolytic capacitor, which has advantages of capacity, low price, and relatively fast charging/discharging characteristics. Aluminum electrolytic capacitors(AEC) have previous advantages, but over time, the capacity of the capacitors decreases due to deterioration and an increase in internal temperature, resulting in a decrease in use efficiency or an accident such as steam extraction due to electrolyte evaporation. It is necessary to take measures to prevent accidents because the failure diagnosis and detection of such capacitors are a very important part of the long-term operation, safety of use, and reliability of the power conversion system because the failure of the capacitor leads to not only a single problem but also a short circuit accident of the power conversion system.

Unified MPPT Control Strategy for Z-Source Inverter Based Photovoltaic Power Conversion Systems

  • Thangaprakash, Sengodan
    • Journal of Power Electronics
    • /
    • 제12권1호
    • /
    • pp.172-180
    • /
    • 2012
  • Z-source inverters (ZSI) are used to realize both DC voltage boost and DC-AC inversion in single stage with a reduced number of power switching devices. A traditional MPPT control algorithm provides a shoot-through interval which should be inserted in the switching waveforms of the inverter to output the maximum power to the Z-network. At this instant, the voltage across the Z-source capacitor is equal to the output voltage of a PV array at the maximum power point (MPP). The control of the Z-source capacitor voltage beyond the MPP voltage of a PV array is not facilitated in traditional MPPT algorithms. This paper presents a unified MPPT control algorithm to simultaneously achieve MPPT as well as Z-source capacitor voltage control. Development and implementation of the proposed algorithm and a comparison with traditional results are discussed. The effectiveness of the proposed unified MPPT control strategy is implemented in Matlab/Simulink software and verified by experimental results.

단상 액티브 파워 필터를 위한 새로운 전류 보상 방법 (A New Current Compensation Estimation Method For Single Phase Active Power Filter)

  • 곽상신;이무영
    • 대한전자공학회:학술대회논문집
    • /
    • 대한전자공학회 1998년도 추계종합학술대회 논문집
    • /
    • pp.819-822
    • /
    • 1998
  • A new active power filter (APF) circuit with a current compesation estimation method is proposed. The current compensation estimation method replaces a current sensor with an estimating circuit and therefore reduces the implementation cost In addition, a simple control scheme, based on the energy balance concept, is adopted to control the voltage of a DC capacitor. Therefore energy change in the DC capacitor can be compensanted in the next cycle. Since a sampling technique is used, a larger DC capacitor voltage ripple can be permissible and a relatively smaller DC capacitor can be used. The proposed method has advantages of the reduction of one current sensor, low implementation cost, and fast transient responses. The theoretical analysis and simulation results are given. The proposed control method is successfully verified by computer simulation.

  • PDF

Electrical Characteristics of Staggered Capacitor ($Si_3N_4$ / HfAlO) for High Performance of Non-volatile Memory

  • 이세원;조원주
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2010년도 하계학술대회 논문집
    • /
    • pp.358-358
    • /
    • 2010
  • To improve the programming/erasing speed and leakage current of multiple dielectric stack tunnel barrier engineering (TBE) Non-volatile memory, We propose a new concept called staggered structure of TBE memory. In this study, We fabricated staggered structure capacitor on $Si_3N_4$ stacked HfAlO and measured C-V curve that can observe tunneling characteristic of this device as various annealing temperature compared with that of single layer $SiO_2$ capacitor.

  • PDF

비선형 부하에서 커패시터 전류 궤환을 통한 고성능 UPS 설계 (A Design of a High Performance UPS with Capacitor Current Feedback for Nonlinear Loads)

  • 이우철;이택기
    • 조명전기설비학회논문지
    • /
    • 제26권5호
    • /
    • pp.71-78
    • /
    • 2012
  • This paper presents a digital control solution to process capacitor current feedback of high performance single-phase UPS for non-linear loads. In all UPS the goal is to maintain the desired output voltage waveform and RMS value over all unknown load conditions and transient response. The proposed UPS uses instantaneous load voltage and filter capacitor current feedback, which is based on the double regulation loop such as the outer voltage control loop and inner current control loop. The proposed DSP-based digital-controlled PWM inverter system has fast dynamic response and low total harmonic distortion (THD) for nonlinear load. The control system was implemented on a 32bit Floating-point DSP controller TMS320C32 and tested on a 5[KVA] IGBT based inverter switching at 11[Khz]. The validity of the proposed scheme is investigated through simulation and experimental results.

비접지 분로 콘덴서 뱅크의 투입제어방식에 대한 시뮬레이션 검증 (Verification of Controlled Closing Method for Unearthed Shunt Capacitor Banks by Simulation)

  • 이우영;박경엽;정진교;김희진
    • 대한전기학회논문지:전기기기및에너지변환시스템부문B
    • /
    • 제52권9호
    • /
    • pp.448-453
    • /
    • 2003
  • In this paper the controlled closing algorithm of the circuit breaker for isolated capacitor banks is proposed. The characteristics of circuit breakers such as RDDS(rate of decrease of dielectric strength) and a mechanical operating tolerance should be also taken into account to locate contact touch instants around voltage zero. The analysis results on the voltages across circuit breaker terminals upon closing operation play an important roles to describe the suggested method. The simulations carried out in order to verify the performance of this method show that the closing instants obtained from the proposed method provide a good suppression effect on the closing transients for both single and back-to-back capacitor banks.

Constant DC Capacitor Voltage Control based Strategy for Active Load Balancer in Three-phase Four-wire Distribution Systems

  • Win, Tint Soe;Tanaka, Toshihiko;Hiraki, Eiji;Okamoto, Masayuki;Lee, Seong Ryong
    • Journal of international Conference on Electrical Machines and Systems
    • /
    • 제3권2호
    • /
    • pp.176-183
    • /
    • 2014
  • Three-phase four-wire distribution systems are used for both three-phase three-wire loads and single-phase two-wire consumer appliances in South Korea, Myanmar and other countries. Unbalanced load conditions frequently occur in these distribution systems. These unbalanced load conditions cause unbalanced voltages for three-phase and single-phase loads, and increase the loss in the distribution transformer. In this paper, we propose constant DC capacitor voltage control based strategy for the active load balancer (ALB) in the three-phase four-wire distribution systems. Constant DC capacitor voltage control is always used in active power line conditioners. The proposed control strategy does not require any computation blocks of the active and reactive currents on the distribution systems. Balanced source-side currents with a unity power factor are obtained without any calculation block of the unbalanced active and reactive components on the load side. The basic principle of the constant DC capacitor voltage control based strategy for the ALB is discussed in detail and then confirmed by both digital computer simulations using PSIM software and prototype experimental model. Simulation and experimental results demonstrate that the proposed control strategy for the ALB can balance the source currents with a unity power factor in the three-phase four-wire distribution systems.

MOCVD를 이용한 $HfO_2/SiNx$ 게이트 절연막의 증착 및 물성 (Deposition and Characterization of $HfO_2/SiNx$ Stack-Gate Dielectrics Using MOCVD)

  • 이태호;오재민;안진호
    • 마이크로전자및패키징학회지
    • /
    • 제11권2호
    • /
    • pp.29-35
    • /
    • 2004
  • 65 nm급 게이트 유전체로의 $HfO_2$의 적용을 위해 hydrogen-terminate된 Si 기판과 ECR $N_2$ plasma를 이용하여 SiNx를 형성한 기판 위에 MOCVD를 이용하여 $HfO_2$를 증착하였다. $450^{\circ}C$에서 증착시킨 박막의 경우 낮은 carbon 불순물을 가지며 비정질 matrix에 국부적인 결정화와 가장 적은 계면층이 형성되었으며 이 계면층은 Hf-silicate임을 알 수 있었다. 또한 $900^{\circ}C$, 30초간 $N_2$분위기에서 RTA 결과 $HfO_2/Si$의 single layer capacitor의 경우 계면층의 증가로 인해 EOT가 열처리전(2.6nm)보다 약 1 nm 증가하였다. 그러나 $HfO_2/SiNx/Si$ stack capacitor의 경우 SiNx 계면층은 열처리후에도 일정하게 유지되었으며 $HfO_2$ 박막의 결정화로 열처리전(2.7nm)보다 0.3nm의 EOT 감소를 나타내었으며 열처리후에도 $4.8{\times}10^{-6}A/cm^2$의 매우 우수한 누설전류 특성을 가짐을 알 수 있었다.

  • PDF

1단구조방식의 PFC회로를 갖는 단상 SRM 구동시스템의 특성해석 (Performance Analysis of Single-phase SRM Drive System with Single-stage Power Factor Correction)

  • 이동희;이진국;안영주;안진우
    • 전력전자학회논문지
    • /
    • 제11권4호
    • /
    • pp.328-339
    • /
    • 2006
  • 본 논문에서는 1 단구조방식의 PFC 회로를 갖는 단상 SRM 구동시스템의 특성해석에 대해 다룬다. 단상 SRM은 기계적 및 전기적 구조가 단순하고, 견고하며, 고속운전특성이 우수하다. 다이오드 브릿지 정류기와 직류링크회로의 커패시터로 구성된 종래의 단상 SRM 구동방식은 커패시터의 짧은 시간의 충 방전 전류에 의해 역률이 크게 저하되는 문제가 발생한다. 따라서, 본 논문에서는 우선 부가적인 능동회로가 없는 1 단방식의 PFC 회로에 대한 분석을 통하여 역률개선 및 토크리플 억제를 위한 스위칭 토플로지를 새로 제안한다. 제안한 스위칭 토플로지로 작동하는 PFC 회로를 갖는 단상 SRM 구동시스템을 구축하고 시스템에 대한 수치해석을 통해 운전속도, 부하토크 및 커패시터 용량에 따른 토크리플, 역률 및 효율 등 시스템의 특성을 얻으며, 이를 실제 실험결과와 비교한다.