• Title/Summary/Keyword: simultaneous quantification

Search Result 225, Processing Time 0.037 seconds

Simultaneous Determination of Synthetic Phosphodiesterase-5 Inhibitors in Dietary Supplements by Liquid Chromatography-High Resolution/Mass Spectrometry

  • Kim, So-Hee;Kim, Ho-Jun;Son, Jung-Hyun;Jeon, Byoung-Wook;Jeong, Eun-Sook;Cha, Eun-Ju;Lee, Jae-Ick
    • Mass Spectrometry Letters
    • /
    • v.3 no.2
    • /
    • pp.50-53
    • /
    • 2012
  • After success of sildenafil for the treatment of erectile dysfunction, a large number of its analogues have been approved from FDA. Recently, the illegal dietary supplements which include sildenafil, vardenafil, tadalafil, or analogues of these drugs as ingredient have been widely distributed. Therefore, the determination of the residue of synthetic phosphodiesterase- 5 (PDE-5) inhibitors in dietary supplements is highly required due to indiscriminate and unintentional overdose caused nausea, chest pains, fainting and irregular heartbeat. In this paper, we report a rapid and sensitive analytical method for the simultaneous determination of nine phosphodiesterase-5 inhibitors by liquid chromatography-high resolution mass spectrometry. The present method was found to be accurate and reproducible with 40 ${\mu}g$/g of the limit of quantification for the nine PDE-5 inhibitors. The developed method can be successfully applied to the analysis of the seven illegal dietary supplements.

Simultaneous Determination of Four Bioactive Constituents in Galgeun Tang by HPLC/DAD. (HPLC-DAD를 이용한 갈근탕 중 4종 성분의 동시분석법 확립)

  • Won, Jin-Bae;Jeon, Won-Kyung;Ma, Jin-Yeul;Ma, Choong-Je
    • Korean Journal of Pharmacognosy
    • /
    • v.40 no.3
    • /
    • pp.224-228
    • /
    • 2009
  • For the quality control of traditional herbal medicine, Galgeun tang, simultaneous determination of glycyrrhizin, paeoniflorin, puerarin, 6-gingerol was established by using a high performance liquid chromatographic (HPLC) method with diode array detector. To separate five four constituents, DIONEX $C_{18}$ column ($5{\mu}m$, $120{\AA}$, $4.6\;mm{\times}150\;mm$) was used with gradient elution system of water and methanol. Validation of the chromatography method was evaluated by linearity, recovery, and precision test. Calibration curve of standard components showed excellent linearity ($R^2$>0.9906). Limits of detection (LOD) and limits of quantification (LOQ) varied from 0.15 to $0.52{\mu}g$/ml and 0.27 to $0.80{\mu}mg$/ml, respectively. The relative standard deviations (RSDs) of data of the intra-day and inter-day experiments were less than 2.88% and 1.21%, respectively. The results of recovery test were ranged from 96.71 to 106.29% with RSD values 0.01-0.80%.

Simultaneous Determination of Sulfonamides in Porcine and Chicken Muscle Using High Performance Liquid Chromatography with Ultraviolet Detector

  • Shim, You-Sin;Shin, Dong-Bin;Cho, Yong-Sun;Choi, Yun-Hee;Lee, Sang-Hee
    • Food Science and Biotechnology
    • /
    • v.18 no.6
    • /
    • pp.1430-1434
    • /
    • 2009
  • The present study used the liquid extraction pretreatment method and developed a liquid chromatographyultraviolet detector (LC-UV) for the simultaneous determination of 14 sulfonamides (SAs) residues in porcine and chicken muscle. Linearity within a range of $50-150\;{\mu}g/kg$ was obtained with the correlation coefficient ($r^2$) of 0.9673-0.9997. The mean recovery of SAs was 55.9-109.7% (relative standard deviations; RSDs 1.7-17.3%) in porcine muscle and 52.8-112.4% (RSDs 2.3-16.9%) in chicken muscle. The limits of detection (LODs) and limits of quantification (LOQs) were 2-32 and $7-96\;{\mu}g/kg$ in porcine muscle, and 4-32 and $13-97\;{\mu}g/kg$ in chicken muscle, respectively. These values were lower than the maximum residue limits (MRLs) established by the European Union. The sum of all SAs residues present should be less than $100\;{\mu}g/kg$.

Simultaneous Determination of the Novel Neuroprotective Agent KR-31378 and its Metabolite KR-31612 Using High Performance Liquid Chromatography with Tandem Mass Spectrometry in Human Plasma

  • Kim, John;Ji, Hye-Young;Yoo, Sung-Eun;Kim, Sun-Ok;Lee, Dong-Ha;Lim, Hong;Lee, Hye-Suk
    • Archives of Pharmacal Research
    • /
    • v.25 no.5
    • /
    • pp.647-651
    • /
    • 2002
  • An LC/MS/MS method for the simultaneous determination of a neuroprotective agent for ischemia-reperfusion damage, KR-31378 and its N-acetyl metabolite KR-31612 in human plasma was developed. KR-31378, KR-31612 and the internal standard. KR-31543 were extracted from human plasma by liquid-liquid extraction. A reverse-phase HPLC separation was performed on Luna phenylhexyl column with the mixture of acetonitrile-5 mM ammonium formate (55:45, v/v) as mobile phase. The detection of analytes was performed using an electrospray ionization tandem mass spectrometry in the multiple reaction monitoring mode. The lower limits of quantification for KR-31378 and KR-31612 were 2.0 ng/ml. The method showed a satisfactory sensitivity, precision, accuracy, recovery and selectivity.

Quantitative Determination of Doxifluridine and 5-FU in Monkey Serum Using LC/MS/MS (LC/MS/MS를 이용한 원숭이 혈액에서의 Doxifluridine과 대사체 5-FU 동시분석법 개발 및 Validation)

  • Woo, Young-Ah;Kim, Ghee-Hwan;Kim, Won;Lee, Jong-Hwa;Jeong, Eun-Ju;Kim, Jin-Ho;Park, Kui-Lea;Kim, Choong-Yong
    • YAKHAK HOEJI
    • /
    • v.51 no.3
    • /
    • pp.174-178
    • /
    • 2007
  • A reverse-phase high performance liquid chromatography method with electrospray ionization and detection by mass spectrometry is described for the simultaneous determination of doxifluridine and its active metabolite 5-flu-orouracil (5-FU) in monkey serum. The method has greater sensitivity and simpler process than previous published methods with good accuracy and precision. A proper liquid/liquid extraction was used to extract simultaneously doxifluridine and 5-FU which has considerable difference in the polarity. Extracts were analyzed using LC/MS/MS providing a short analysis time within 5 min. The lower limit of quantification was validated at 10.0 ng/ml of serum for both doxifluridine and 5-FU. Accuracy and precision of quality control (QC) samples for both analytes met FDA Guidance criteria of ±15% for average QC accuracy with coefficients of variation less than 15%. The method will be applicable for preclinical studies and bioequivalence studies.

Simultaneous Analysis of Liquiritin and Glycyrrhizin in Sagunja-tang by HPLC-PDA (HPLC-PDA에 의한 사군자탕 중 Liquiritin과 Glycyrrhizin의 동시분석)

  • Seo, Chang-Seob;Kim, Jung-Hoon;Shin, Hyeun-Kyoo
    • Korean Journal of Pharmacognosy
    • /
    • v.42 no.3
    • /
    • pp.240-245
    • /
    • 2011
  • A high-performance liquid chromatography (HPLC) method was developed for quantitative analysis of liquiritin and glycyrrhizin in Sagunja-tang (SGT, Sijunzi-tang in Chinese), a traditional Korean medicine. HPLC analysis was performed using a Gemini C18 column operating at $40^{\circ}C$, and photodiode array (PDA) detection at 254 nm and 280 nm for quantification of the two components in SGT. The mobile phase using a gradient flow consisted of two solvent systems. Solvent A was 1.0% (v/v) aqueous acetic acid and solvent B was acetonitrile with 1.0% (v/v) acetic acid. Calibration curves were acquired with $r^2$ values > 0.9998, and the relative standard deviations (RSDs, %) for intra- and inter-day precision were not exceed 4.0%. The recovery of each component was in the range of 91.85 - 108.62%, with a RSD less than 4.0%. The contents of the two components in SGT were 7.94 - 13.83 mg/g.

Simultaneous analysis of sugars by HPLC (HPLC를 이용한 당류의 동시분석법)

  • 허부홍;서형석;김성문;김영진;조종후
    • Korean Journal of Veterinary Service
    • /
    • v.23 no.2
    • /
    • pp.137-142
    • /
    • 2000
  • In order to develop a good separation and simultaneous analysis of different sugar in an artificial mixed sugar solution, we analyzed 10 sugar components in an artificial mixed sugar solution composed of fructose, glucose, mannitol, sucrose, maltose, lactose, xylose, xylitol erythritol, and trehalose with using HPLC-ELSD or HPLC-RI. Separation and quantification by HPLC-ELSD was superior to those by HPLC-RI and detection sensitivity by HPLC-ELSD was higher then that by HPLC-RI as micorgram($\mu\textrm{g}$) level. 1. The units of minimal detectable limits were showed $\mu\textrm{g}$/$m\ell$ and ng/$m\ell$ by the HPLC-RI and HPLC-ELSD, respectively. 2. The condition of ELSD was drift tube temperature $82^{\circ}C$, $N_2$ gas flow rate 2.10 SLPM, and colum oven temperature $30^{\circ}C$, respectively. Isolation and recovery rates of single sugar from the multiple sugar solution was higher at the condition (time: flow rate: D.W.:ACN MeOH, min : $m\ell$/min:v:v:v) of linear gradient elution of mobile phase as 0 : 1.00 : 15 : 85 : 0.1 : 1.00 : 6 : 90 : 4, 17 : 1.00 : 10 : 70 : 20, 28 : 1.00 : 15 : 85 : 0 an 35 : 1.00 : 15 : 85 : 0, in order.

  • PDF

Simultaneous Determination of Anthraquinone, Flavonoids, and Phenolic Antidiabetic Compounds from Cassia auriculata Seeds by Validated UHPLC Based MS/MS Method

  • Girme, Aboli;Saste, Ganesh;Chinchansure, Ashish;Joshi, Swati;Kunkulol, Rahul;Hingorani, Lal;Patwardhan, Bhushan
    • Mass Spectrometry Letters
    • /
    • v.11 no.4
    • /
    • pp.82-89
    • /
    • 2020
  • A systematic isolation and characterization study for Cassia auriculata (CA) seeds resulted in identifying antidiabetic compounds 1,3,8-trihydroxyanthraquinone and quercetin, quercetin-3-O-rutinoside, gallic acid, caffeic acid, ferulic acid, and ellagic acid. The ultra-high-performance liquid chromatography based triple quadrupole mass spectrometry methodology was developed and validated for simultaneous identification and confirmation of these compounds from CA seeds. Multiple reaction monitoring (MRM) based quantification method was developed with MRM optimizer software for MS1 and MS2 mass analysis. The method was optimized on precursor ions and product ions with the ion ratio of each compound. The calibration curves of seven bioactive analytes showed excellent linearity (r2 ≥ 0.99). The quantitation results found precise (RSD, < 10 %) with good recoveries (84.58 to 101.42%). The matrix effect and extraction recoveries were found within the range (91.66 to 102.11%) for the CA seeds. This is the first MS/MS-based methodology applied to quantifying seven antidiabetic compounds in CA seeds and its extract for quality control purposes.

Simultaneous detection of five biocides in household products by gas chromatography-mass spectrometry

  • Choi, Kyeong-Yun;Lim, Hyun-Hee;Shin, Ho-Sang
    • Analytical Science and Technology
    • /
    • v.35 no.5
    • /
    • pp.197-204
    • /
    • 2022
  • A gas chromatography-mass spectrometric method was developed for determining 5-chloro-2-methyl-4-isothiazolin-3-one (CMIT), 2-methyl-4-isothiazolin-3-one (MIT), 1,2-benzisothiazolin-3-one (BIT), 3-iodo-2-propynyl butyl carbamic acid (IPBC) and benzoic acid (BA) in household products. A 0.5 g sample was placed in a test tube and dissolved with 5 mL water, 5 mL methylene chloride and 1.0 mL methanol. The solution was extracted by ultra-sonication followed by mechanical shaking using the salting out effect. Under the established condition, the lowest quantification limits of all analytes were in the range of 0.04-10 mg/kg and their relative standard deviations were less than 8.0 %. The method was used to analyze 10 household products. As a result of analyzing 10 household products, MIT was detected in the range of 1.2-3.5 mg/kg in 3 of 10 samples, CMIT was detected in the range of 2.6-8.2 mg/kg in 3 of 10 samples, and BA was detected in the range of 5.0-15 mg/kg in 4 of 10 samples. Meanwhile, BIT and IPBC were not detected in any of the products. It has been shown that this method can be used for the simultaneous determination of biocides with various physical and chemical properties in household products.

Background Gradient Correction using Excitation Pulse Profile for Fat and $T_2{^*}$ Quantification in 2D Multi-Slice Liver Imaging (불균일 자장 보정 후처리 기법을 이용한 간 영상에서의 지방 및 $T_2{^*}$ 측정)

  • Nam, Yoon-Ho;Kim, Hahn-Sung;Zho, Sang-Young;Kim, Dong-Hyun
    • Investigative Magnetic Resonance Imaging
    • /
    • v.16 no.1
    • /
    • pp.6-15
    • /
    • 2012
  • Purpose : The objective of this study was to develop background gradient correction method using excitation pulse profile compensation for accurate fat and $T_2{^*}$ quantification in the liver. Materials and Methods: In liver imaging using gradient echo, signal decay induced by linear background gradient is weighted by an excitation pulse profile and therefore hinders accurate quantification of $T_2{^*}$and fat. To correct this, a linear background gradient in the slice-selection direction was estimated from a $B_0$ field map and signal decays were corrected using the excitation pulse profile. Improved estimation of fat fraction and $T_2{^*}$ from the corrected data were demonstrated by phantom and in vivo experiments at 3 Tesla magnetic field. Results: After correction, in the phantom experiments, the estimated $T_2{^*}$ and fat fractions were changed close to that of a well-shimmed condition while, for in vivo experiments, the background gradients were estimated to be up to approximately 120 ${\mu}T/m$ with increased homogeneity in $T_2{^*}$ and fat fractions obtained. Conclusion: The background gradient correction method using excitation pulse profile can reduce the effect of macroscopic field inhomogeneity in signal decay and can be applied for simultaneous fat and iron quantification in 2D gradient echo liver imaging.