• Title/Summary/Keyword: simultaneous

Search Result 6,411, Processing Time 0.035 seconds

Design and Performance Improvement of Simultaneous Single Band Duplex System Using Turbo Equalizer (터보 등화기를 사용한 SSD 시스템 설계와 성능 개선)

  • An, Changyoung;Ryu, Heung-Gyoon
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.39A no.1
    • /
    • pp.28-35
    • /
    • 2014
  • In this paper, we propose a SSD(simultaneous single band duplex) system with turbo equalizer for full-duplex over harsh ISI(inter symbol interference) channel. The proposed system uses RF(radio frequency) cancellation and digital cancellation to cancel self-interference caused by simultaneous single band duplex communication. Also, using turbo equalizer, the proposed system equalizes signal after digital cancellation. In this paper, we design SSD system with turbo equalizer. And then we evaluate BER(bit error rate) performance of the proposed system comparison with SSD system with adaptive equalizer. We use simulink program to confirm BER performance of the proposed system. The simulation results shows that the proposed system equalizes received signal effectively over harsh ISI channel and BER performance of the proposed system is better than BER performance of SSD system with adaptive equalizer.

Simultaneous Analysis of Six Compounds in Yijin-tang by HPLC-PDA (HPLC-PDA을 이용한 이진탕 중 6종 성분의 동시분석)

  • Kim, Seong-Sil;Kim, Jung-Hoon;Shin, Hyeun-Kyoo;Seo, Chang-Seob
    • Herbal Formula Science
    • /
    • v.21 no.1
    • /
    • pp.71-79
    • /
    • 2013
  • Objectives : Yijin-tang has been used in the treatment of gastrointestinal diseases such as irritable bowel syndrome, gastritis, and gastric ulcer. In this study, a high-performance liquid chromatography (HPLC) method was established for simultaneous analysis of six compounds, liquiritin, glycyrrhizin, hesperidin, 6-gingerol, homogentisic acid, and 3,4-dihydroxybenzaldehyde in Yijin-tang, a traditional Korean herbal medicinal preparation. Methods : A Gemini C18 column was used for the separation of six constituents at $40^{\circ}C$. The mobile phase using gradient elution consist of two solvent systems, 1.0% acetic acid in water (A) and 1.0% acetic acid in acetonitrile (B). The flow-rate was 1.0 mL/min and injection volume was $10{\mu}g$. The detector was a photodiode array (PDA) detector set at 254 nm and 280 nm. Results : The calibration curves of six compounds showed good linearity in various concentration ranges ($R^2{\geq}0.9997$). The limits of detection (LOD) and limits of quantification (LOQ) were 0.028-$0.192{\mu}g/mL$ and 0.093-$0.540{\mu}g/mL$, respectively. The RSD (%) of the intra and inter day validations were 0.03-0.84% and 0.05 -1.00%, respectively. Recovery was 96.14-01.90% and RSD (%) was less than 1.5%. Conclusions : The established simultaneous analysis methods will help management to improve the quality of Yijin-tang.

Hippocampal Sparing Whole Brain Radiotherapy and Integrated Simultaneous Boost vs Stereotactic Radiosurgery Boost: A Comparative Dosimetric Planning Study

  • Cheah, Soon Keat;Matthews, Thomas;Teh, Bin Sing
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.17 no.9
    • /
    • pp.4233-4235
    • /
    • 2016
  • Background: Whole brain radiotherapy (WBRT) and stereotactic radiosurgery were frequently used to palliate patients with brain metastases. It remains controversial which modality or combination of therapy is superior especially in the setting of limited number of brain metastases. The availability of newer medical therapy that improves survival highlighted the importance of reducing long term radiation toxicity associated with WBRT. In this study, we aim to demonstrate the hippocampal sparing technique with whole brain and integrated simultaneous boost Materials and Methods: Planning data from 10 patients with 1-5 brain metastases treated with SRS were identified. Based on the contouring guideline from RTOG atlas, we identified and contoured the hippocampus with 5mm isocentric expansion to form the hippocampal avoidance structure. The plan was to deliver hippocampal sparing whole brain radiotherapy (HSWBRT) of 30 Gy in 10 fractions and simultaneous boost to metastatic lesions of 30 Gy in 10 fractions each. Results: The PTV, hippocampus and hippocampal avoidance volumes ranges between 1.00 - 39.00 cc., 2.50 - 5.30 cc and 26.47 - 36.30 cc respectively. The mean hippocampus dose for the HSWBRT and HSWBRT and SIB plans was 8.06 Gy and 12.47 respectively. The max dose of optic nerve, optic chiasm and brainstem were kept below acceptable range of 37.5 Gy. Conclusions: The findings from this dosimetric study demonstrated the feasibility and safety of treating limited brain metastases with HSWBRT and SIB. It is possible to achieve the best of both worlds by combining HSWBRT and SIB to achieve maximal local intracranial control while maintaining as low a dose as possible to the hippocampus thereby preserving memory and quality of life.

Simultaneous Equation Models for Evaluating Roundabout Accidents According to Different Driving Types (연립방정식을 이용한 운전유형별 회전교차로 사고모형)

  • Kim, Kyung Hwan;Park, Byung Ho
    • Journal of Korean Society of Transportation
    • /
    • v.30 no.5
    • /
    • pp.3-10
    • /
    • 2012
  • This study dealt with traffic accidents occurring within roundabouts. The objective was to develop roundabout accident models for different driving types by using simultaneous equations. In pursuing the above, this study used a statistical program SPSS 17.0 to accommodate data from 148 accidents occurred within 39 roundabouts of Korea. In addition, the 2SLS(2 stage least square) estimation method was adopted to calibrate the models. The main results are as follows. First, both the number of accidents and the EPDO were evaluated to have bilateral relationships. Second, all 6 different simultaneous equation models according to driving types were found to be statistically significant. Third, the developed models were compared to each other with respect to either common or specific variables. Finally, variables such as ADT, conflicting rate, heavy vehicle ratio, circulatory roadway width, number of circulatory roadway lane, approach lane width, average approach lanes, parking places, and bus stops were selected as independent variables for the models.

An Anti-Sway Control System Design Based on Simultaneous Optimization Design Approach (동시최적화 설계기법을 이용한 항만용 크레인의 흔들림 제어계 설계)

  • Kim, Young-Bok;Moon, Duk-Hong;Yang, Joo-Ho;Chae, Gyu-Hoon
    • Journal of Ocean Engineering and Technology
    • /
    • v.19 no.3
    • /
    • pp.66-73
    • /
    • 2005
  • The sway motion control problem of a container hanging on the trolley is considered in this paper. In the container crane control problem, the main issue involves suppressing the residual swing motion of the container at the end of acceleration, during deceleration, or for an unexpected disturbance input. For this problem, in general, many trolley motion control strategies are introduced and applied. In this paper, we introduce and synthesize a swing motion control system, in which a small auxiliary mass is installed on the spreader. In this control system, the actuator reacting against the auxiliary mass applies inertial control forces to the container to reduce the swing motion in the desired manner. In many studies, the controllers used to suppress the vibration have been synthesized for the given mathematical model of plants. In many cases, the designers have not been able to utilize the degree of freedom to adjust the structural parameters for the control object. To overcome this problem, so called "Structure/Control Simultaneous Method" is used. From this, in this paper the simultaneous design method is used to achieve optimal system performance. And the experimental result shows that the proposed control strategy is useful, to the case of that the controlled system is exposed to the uncertainties and, robust to disturbances like wind.

SIMULTANEOUS SWITCHING NOISE MINIMIZATION TECHNIQUE USING DUAL LAYER POWER LINE MUTUAL INDUCTORS (이중 층 파워 메탈구조의 상호 인덕터를 이용한 동시 스위칭 잡음 최소화 기법)

  • Lee, Yong-Ha;Kang, Sung-Mook;Moon, Gyu
    • Journal of the Institute of Electronics Engineers of Korea SD
    • /
    • v.39 no.6
    • /
    • pp.44-50
    • /
    • 2002
  • A novel technique for minimization of simultaneous switching noise is Presented. Dual Layer Power Line (DLPL) structure i:; newly proposed for a possible silicon realization of a mutual inductor, with which an instant large current in the power line is half-divided flowing through two different, but closely coupled, layers in opposite directions. This mutual inductance between two power layers enables us to significantly reduce the switching noise. SPICE simulations show that with a mutual coupling coefficient higher than 0.8, the switching noise reduces by 63% compared to the previously reported solutions. This DLPL technique can also be applied to PCB artworks.

Circular Path Generation Technique for Ball Bar Measurement by Simultaneous Movement of Two Axes (2 축 동시구동을 통한 볼바 측정용 원호경로 생성 방법)

  • Lee, Dong-Mok;Lee, Hoon-Hee;Yang, Seung-Han
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.37 no.6
    • /
    • pp.783-790
    • /
    • 2013
  • Circular path generation for ball bar measurement using the simultaneous movement of two axes with at least one rotary axis requires the execution of CAM software. However, a change in the machine type or measurement condition requires a new execution of the CAM software, which is cumbersome. This paper presents a circular path generation technique that does not require CAM software and is applicable to different types of driving axes with an arbitrary structural configuration of machine tools and any ball bar setup condition. Mathematical equations are derived for three cases using the proposed technique. In addition, to inspect the measurement feasibility for avoiding physical interference among the ball bar parts, a tilting angle calculation is proposed. The validity of the proposed technique was verified by performing a ball bar experiment with A and C as the simultaneous axes of a five-axis machine tool.

Outcome after Simultaneous Resection of Gastric Primary Tumour and Synchronous Liver Metastases: Survival Analysis of a Single-center Experience in China

  • Liu, Qian;Bi, Jian-Jun;Tian, Yan-Tao;Feng, Qiang;Zheng, Zhao-Xu;Wang, Zheng
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.16 no.4
    • /
    • pp.1665-1669
    • /
    • 2015
  • Background: The optimal surgical strategy for the treatment of synchronous resectable gastric cancer liver metastases remains controversial. The aims of this study were to analyze the outcome and overall survival of patients presenting with gastric cancer and liver metastases treated by simultaneous resection. Materials and Methods: Between January 1990 and June 2009, 35 patients diagnosed with synchronous hepatic metastases from gastric carcinoma received simultaneous resection of both primary gastric cancer and synchronous hepatic metastases. The clinicopathologic features and the surgical results of the 35 patients were retrospectively analyzed. Results: The 5-year overall survival rate after surgery was 14.3%. Five patients survived for more than 5 years after surgery. No mortality has occurred within 30 days after resection, although two patients (5.7%) developed complications during the peri-operative course. Univariate analysis revealed that patients with the presence of lymphovascular invasion of the primary tumor, bilateral liver metastasis and multiple liver metastases suffered poor survival. Lymphovascular invasion by the primary lesion and multiple liver metastases were significant prognostic factors that influenced survival in the multivariate analysis (p=0.02, p=0.001, respectively). Conclusions: The presence of lymphovascular invasion of the primary tumor and multiple liver metastases are significant prognostic determinants of survival. Gastric cancer patients without lymphovascular invasion and with a solitary synchronous liver metastasis may be good candidates for hepatic resection. Simultaneous resection of both primary gastric cancer and synchronous hepatic metastases may effectively prolong survival in strictly selected patients.

Fabrication of Disposable Protein Chip for Simultaneous Sample Detection

  • Lee, Chang-Soo;Lee, Sang-Ho;Kim, Yun-Gon;Oh, Min-Kyu;Hwang, Taek-Sung;Rhee, Young-Woo;Song, Hwan-Moon;Kim, Bo-Yeol;Kim, Yong-Kweon;Kim, Byung-Gee
    • Biotechnology and Bioprocess Engineering:BBE
    • /
    • v.11 no.5
    • /
    • pp.455-461
    • /
    • 2006
  • In this study, we have described a method for the fabrication of a protein chip on silicon substrate using hydrophobic thin film and microfluidic channels, for the simultaneous detection of multiple targets in samples. The use of hydrophobic thin film provides for a physical, chemical, and biological barrier for protein patterning. The microfluidic channels create four protein patterned strips on the silicon surfaces with a high signal-to-noise ratio. The feasibility of the protein chips was determined in order to discriminate between each protein interaction in a mixture sample that included biotin, ovalbumin, hepatitis B antigen, and hepatitis C antigen. In the fabrication of the multiplexed assay system, the utilization of the hydrophobic thin film and the microfluidic networks constitutes a more convenient method for the development of biosensors or biochips. This technique may be applicable to the simultaneous evaluation of multiple protein-protein interactions.

Simultaneous Determination of Creatine, Dicyandiamide and Dihydrotriazine in Dietary Supplements by High Performance Liquid Chromatography (고성능 액체크로마토그래피를 이용한 식이보충제에서 크레아틴, 디시안디아마이드, 디하이드로트리아진의 동시분석)

  • Park, Sang-Wook;Yoo, Myung-Sang;Lee, Wonjae
    • KSBB Journal
    • /
    • v.29 no.4
    • /
    • pp.232-238
    • /
    • 2014
  • The simultaneous determination of creatine monohydrate (CrM), dicyandiamide and dihydrotriazine in dietary supplements using reversed-phase high performance liquid chromatography (HPLC) was developed. Chromatography was performed on a Nuclosil 100-5 SA ($4.6{\times}250mm$) column with a mobile phase of 2.3% ammonium phosphate (pH 5.5), and UV detection at 224 nm, 212 nm, and 237 nm, respectively. The performance characteristics of HPLC were determined in terms of selectivity, linearity, precision, recovery, limit of detection (LOD), and limit of quantification (LOQ). The calibration curves were linear within the concentration range of $40.0{\sim}500.0{\mu}g/mL$ for creatine, $0.1{\sim}12.8{\mu}g/mL$ for dicyandiamide, and $0.05{\sim}6.4{\mu}g/mL$ for dihydrotriazine. The detection limits of the method were 1.09, 0.01, and $0.08{\mu}g/mL$ for creatine, dicyandiamide, and dihydrotriazine, respectively. The recoveries of creatine, dicyandiamide, and dihydrotriazine were 97.2~100.9, 92.3~106.5, and 97.2~105.5%, respectively. It is expected that the chromatographic analytical method developed in this study will be usefully applicable to simultaneous determination of creatine, dicyandiamide, and dihydrotriazine contained in dietary supplements.