• 제목/요약/키워드: simplified design procedure

검색결과 157건 처리시간 0.023초

개선된 드릴 디자인을 적용한 간소화된 드릴링 과정에 관한 연구 (A study on simplified procedure of enhanced designed implant drill)

  • 윤지훈;전계록;윤미정;허중보;정창모
    • 대한치과의사협회지
    • /
    • 제53권5호
    • /
    • pp.368-376
    • /
    • 2015
  • Purpose : The objective of this research was to develop a more simplified drilling procedure with an enhanced implant drill. Materials and Methods : The drill enhanced design factors enabled implantation of Dia. 5.0mm fixture with only 2 times drilling which is more simplified drilling procedure. The enhanced drill was designed with 2 flutes, 2-phase or 3-phase formed drill tip and 25 degrees of helix angle. The proposed drilling procedure (2 times) was compared with a general drilling process (4 times) in terms of temperature changes, cutting time and ISQ value. Results : The simplified drilling procedure indicated less heat than a conventional drilling procedure (p<0.05). The enhanced drill showed significantly shorter drilling time than a conventional drill (p<0.05). On the other hand, higher insertion torque and ISQ value were observed on the the suggested drilling procedure than the conventional drilling procedure (p<0.05). Conclusion : A simplified drilling procedure with the newly designed drill could provide higher effectiveness and safety of dental implant operations under properly controlled external conditions, such as irrigation and RPM of drilling.

A simplified design procedure for seismic retrofit of earthquake-damaged RC frames with viscous dampers

  • Weng, D.G.;Zhang, C.;Lu, X.L.;Zeng, S.;Zhang, S.M.
    • Structural Engineering and Mechanics
    • /
    • 제44권5호
    • /
    • pp.611-631
    • /
    • 2012
  • The passive energy dissipation technology has been proven to be reliable and robust for recent practical applications. Various dampers or energy dissipation devices have been widely used in building structures for enhancing their performances during earthquakes, windstorm and other severe loading scenarios. This paper presents a simplified seismic design procedure for retrofitting earthquake-damaged frames with viscous dampers. With the scheme of designing the main frame and the supplemental viscous dampers respectively, the seismic analysis model of damped structure with viscous dampers and braces was studied. The specific analysis process was described and approach to parameter design of energy dissipation components was also proposed. The expected damping forces for damped frame were first obtained based on storey shear forces; and then they were optimized to meet different storey drift requirements. A retrofit project of a RC frame school building damaged in the 2008 Wenchuan earthquake was introduced as a case study. This building was retrofitted by using viscous dampers designed through the simplified design procedure proposed in this paper. Based on the case study, it is concluded that this simplified design procedure can be effectively used to make seismic retrofit design of earthquake-damaged RC frames with viscous dampers, so as to achieve structural performance objectives under different earthquake risk levels.

Simplified elastic-plastic analysis procedure for strain-based fatigue assessment of nuclear safety class 1 components under severe seismic loads

  • Kim, Jong-Sung;Kim, Jun-Young
    • Nuclear Engineering and Technology
    • /
    • 제52권12호
    • /
    • pp.2918-2927
    • /
    • 2020
  • This paper proposes a simplified elastic-plastic analysis procedure using the penalty factors presented in the Code Case N-779 for strain-based fatigue assessment of nuclear safety class 1 components under severe seismic loads such as safety shutdown earthquake and beyond design-basis earthquake. First, a simplified elastic-plastic analysis procedure for strain-based fatigue assessment of nuclear safety class 1 components under the severe seismic loads was proposed based on the analysis result for the simplified elastic-plastic analysis procedure in the Code Case N-779 and the stress categories corresponding to normal operation and seismic loads. Second, total strain amplitude was calculated directly by performing finite element cyclic elastic-plastic seismic analysis for a hot leg nozzle in pressurizer surge line subject to combined loading including deadweight, pressure, seismic inertia load, and seismic anchor motion, as well as was derived indirectly by applying the proposed analysis procedure to the finite element elastic stress analysis result for each load. Third, strain-based fatigue assessment was implemented by applying the strain-based fatigue acceptance criteria in the ASME B&PV Code, Sec. III, Subsec. NB, Article NB-3200 and by using the total strain amplitude values calculated. Last, the total strain amplitude and the fatigue assessment result corresponding to the simplified elastic-plastic analysis were compared with those using the finite element elastic-plastic seismic analysis results. As a result of the comparison, it was identified that the proposed analysis procedure can derive reasonable and conservative results.

프리캐스트 병렬 전단벽의 내진 설계에 관한 연구 (A Simplified Seismic Design Method of Precast Coupled Shear Wall)

  • 홍성걸
    • 한국지진공학회:학술대회논문집
    • /
    • 한국지진공학회 1998년도 추계 학술발표회 논문집 Proceedings of EESK Conference-Spring 1998
    • /
    • pp.65-74
    • /
    • 1998
  • In seismic design procedure of precast concrete structure, it is important to assign ductility requirement on the connection element for a favorable failure mechanism. The purpose of this paper is to propose a simplified procedure to determine the required ductility of coupling beam in coupled precast shear wall for a lateral displacement ductility at the top of a structure. This study shows that an equation for ductility of cloupling beam is introduced on the basis of several basic assumption.

  • PDF

주파수 영역 해석을 활용한 부유식 해상풍력 플랫폼 초기 구조설계 절차 연구 (Study on FOWT Structural Design Procedure in Initial Design Stage Using Frequency Domain Analysis)

  • 한익승;하윤진;김경환
    • 풍력에너지저널
    • /
    • 제14권1호
    • /
    • pp.29-36
    • /
    • 2023
  • The analysis of the floating offshore wind turbine platform is based on the procedures provided by the IEC including the International Classification Society, which recommends the analysis in the time domain. But time-domain simulation requires a lot of time and resources to solve tens of thousands of DLCs. This acts as a barrier in terms of floating structure development. For final verification, it requires very precise analysis in the time domain, but from an initial design point of view, a simplified verification procedure to predict the quantity of materials quickly and achieve relatively accurate results is crucial. In this study, a structural design procedure using a design wave applied in the oil and gas industries is presented combined with a conservative turbine load. With this method, a quick design spiral can be rotated, and it is possible to review FOWTs of various shapes and sizes. Consequently, a KRISO Semi-Submersible FOWT platform was developed using a simplified design procedure in frequency-domain analysis.

Effective lengths of braced frame columns

  • Girgin, Konuralp;Ozmen, Gunay
    • Structural Engineering and Mechanics
    • /
    • 제28권2호
    • /
    • pp.189-206
    • /
    • 2008
  • In several design codes and specifications, simplified formulae and charts are given for determining the effective lengths of frame columns. It is shown that these formulae may yield rather erroneous results in certain cases. This is due to the fact that, the code formulae utilise only local stiffness distributions. In this paper, a simplified procedure for determining approximate values for the buckling loads of braced frames is developed. The procedure utilises a fictitious load analysis of frames and yields errors less than 10%, which may be considered suitable for design purposes. The proposed procedure is applied to several numerical examples and it is shown that all the errors are in the acceptable range.

Buckling lengths of unbraced multi-storey frame columns

  • Ozmen, Gunay;Girgin, Konuralp
    • Structural Engineering and Mechanics
    • /
    • 제19권1호
    • /
    • pp.55-71
    • /
    • 2005
  • In several design codes and specifications, simplified formulae and diagrams are given for determining the buckling lengths of frame columns. It is shown that these formulae may yield rather erroneous results in certain cases. This is due to the fact that, the code formulae utilise only local stiffness distributions. In this paper, a simplified procedure for determining approximate values for the buckling loads of multi-storey frames is developed. The procedure utilises lateral load analysis of frames and yields errors in the order of 10%, which may be considered suitable for design purposes. The proposed procedure is applied to several numerical examples and it is shown that all the errors are in the acceptable range and on the safe side.

강합성교 설계를 위한 하중분배계수 간략식 (Simplified Load Distribution Factor Equation for the Design of Composite Steel Girder Bridges)

  • 정원석
    • 한국강구조학회 논문집
    • /
    • 제17권2호통권75호
    • /
    • pp.131-138
    • /
    • 2005
  • 강합성 교량의 설계시 종방향 모멘트에 하중분배계수를 고려하여 주형의 최대 모멘트를 계산하고 있다. 이러한 하중분배계수식은 1930년경부터 AASHTO 시방서에 채택된 이후 소폭의 수정을 거듭해 오다가 1994년 LRFD 시방서부터 전폭적으로 수정되었다. LRFD 시방서의 하중분배계수 식은 실제 교량의 거동을 비교적 정확히 반영하고 있는 것으로 알려져 있다. 하지만 LRFD식은 설계모멘트 결정단계에서는 확정할 수 없는 종방향 강성계수를 포함하고 있으므로 반복을 통한 설계를 요구한다. 이러한 LRFD식이 내포하는 반복 설계과정으로 인해 실무에서는 널리 쓰이지 않고 있는 실정이다. 따라서 본 연구에서는 반복 설계과정을 필요로 하지 않는 I형 강합성교량의 하중분배간략식을 LRFD식에 근거하여 도출하였다. 간략식의 검증을 위해 43개의 대표교량의 유한요소해석을 통해 구한 엄밀 하중분배계수와 AASHTO LRFD 식, AASHTO Standard 식으로 구한 하중분배계수와 비교하였다. 그 결과 간략식이 구조물의 안전성을 확보하면서 반복계산을 필요로 하지 않는 것으로 확인되었다.

고층건물의 단순화된 동적해석 (Simplified Dynamic Analysis of High-Rise Buildings)

  • 이동근;황재호
    • 한국전산구조공학회:학술대회논문집
    • /
    • 한국전산구조공학회 1993년도 봄 학술발표회논문집
    • /
    • pp.101-108
    • /
    • 1993
  • A simplified dynamic analysis method for high-rise building structures is proposed in this study. In the proposed method, member forces are obtained through static analysis using story forces derived from story shear forces which are obtained using dynamic analysis procedure. Major advantage of the proposed method is in the convenience in load combinations for design analysis.

  • PDF

스위칭 다이나믹을 이용한 단순화된 극점 배치 기법의 개발 (Development of a simplified pole-placement design using swtching dynamics)

  • 박귀태;김동식;서삼준;서호준
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 1993년도 한국자동제어학술회의논문집(국내학술편); Seoul National University, Seoul; 20-22 Oct. 1993
    • /
    • pp.947-952
    • /
    • 1993
  • A simplified pole-placement design method is developed by analysing dynamic characteristics of the switching dynamics. Unlike the design procedure of conventional pole-placement, in the proposed method, overall state-space is directly decomposed into two invariant subspaces by the projection operator which is defined in the equivalent system, and then the closed-loop poles are assigned to each subspace independently. Hence, computations for state-feedback gain matrix are easy and simple.

  • PDF