• Title/Summary/Keyword: simple measurement method

Search Result 942, Processing Time 0.029 seconds

Calibration of Geometric Errors of a Parallel Manipulator Using a Sensor of Length Measurement (길이 측정 센서를 이용한 병렬기구의 기하학적 오차 보정)

  • Choi, Woo-Chun;Lim, Hyun-Kyu
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.17 no.11
    • /
    • pp.94-100
    • /
    • 2000
  • This paper proposes a method of geometric error calibration for a parallel using only sensor of length measurement without additional sensors. The concept is generalized which creates measurement residuals by exploring conflicting information provided with external length sensing. Although this calibration method requires many configurations, it has an advantage of using relatively simple length measurements. This method is shown to provide good calibration results, especially when there exist smaller measurement noises and more configurations are measured.

  • PDF

Optical Straightness Measuring System Using a Ball-lens (볼렌즈를 이용한 광학식 진직도 측정시스템)

  • Lee, Minho;Cho, Nahm-Gyoo
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.31 no.12
    • /
    • pp.1133-1139
    • /
    • 2014
  • This paper proposes a simple method to improve a sensitivity of a straightness measurement system for a linear stage, which is applied to a system based on a geometric optic method. An optical system for this method is composed of a corner-cube retro-reflector, a ball-lens and a twodimensional position sensitive detector (2D PSD). The effectiveness of the proposed method was examined theoretically, and verified experimentally using a prototype measurement system. The results show that the measuring sensitivity was dependent on the size of the ball-lens and the setup position of PSD from the ball-lens, and that the proposed method is efficient method to improve the measuring sensitivity.

A Simple ESR Measurement Method for DC Bus Capacitor Using DC/DC Converter (DC/DC 컨버터를 이용한 DC Bus 커패시터의 간단한 ESR 측정 기법)

  • Shon, Jin-Geun;Kim, Jin-Sik
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.59 no.4
    • /
    • pp.372-376
    • /
    • 2010
  • Electrolytic capacitors have been widely used in power electronics system because of the features of large capacitance, small size, high-voltage, and low-cost. Electrolytic capacitors, which is most of the time affected by aging effect, plays a very important role for the power electronics system quality and reliability. Therefore it is important to estimate the parameter of an electrolytic capacitor to predict the failure. The estimation of the equivalent series resistance(ESR) is important parameter in life condition monitoring of electrolytic capacitor. This paper proposes a simple technique to measure the ESR of an electrolytic capacitor. This method uses a switching DC/DC boost converter to measure the DC Bus capacitor ESR of power converter. Main advantage of the proposed method is very simple in technique, consumes very little time and requires only simple instruments. Simulation results are shown to verify the performance of the proposed method.

Reduction of Minimum Switching Duration in the Measurement of Three Phase Current with DC-Link Current Sensor (DC링크 전류센서를 이용한 삼상전류 측정 방식에서 최소 스위칭 시간의 단축)

  • 김경서
    • The Transactions of the Korean Institute of Electrical Engineers B
    • /
    • v.52 no.12
    • /
    • pp.649-654
    • /
    • 2003
  • The simplest method for measuring output currents of the three phase inverters is to measure them with three current sensors such as hall sensors. This method requires at least two current sensors, and these types of sensors are somewhat expensive. More economical method is measuring DC link current with a simple shunt resistor, then, reconstructing output current using the DC link current value and the switching status. However, in low speed region, the measurement becomes difficult and even impossible due to the requirement of minimum switching duration for A/D conversion. These problems can be overcome by limitation of switching duration. Limitation of switching, however, causes voltage and current distortion. Owing to compensation, distortion can be effectively suppressed. However these increase acoustic noise due to increment of current ripple. In this paper, a current measurement method is proposed, which can reduce minimum switching duration resulting in reduction of acoustic noise. The validity of proposed method is confirmed through experiment.

A New Method for the Determination of Carrier Lifetime in Silicon Wafers from Conductivity Modulation Measurements

  • Elani, Ussama A.
    • JSTS:Journal of Semiconductor Technology and Science
    • /
    • v.8 no.4
    • /
    • pp.311-317
    • /
    • 2008
  • The measurement of dark ${\sigma}_D$, gamma-induced ${\sigma}_{\gamma}$ conductivities and the expected conductivity modulation ${\Delta}_{\sigma}$ in silicon wafers/samples is studied for developing a new technique for carrier lifetime evaluation. In this paper a simple method is introduced to find the carrier lifetime variations with the measured conductivity and conductivity modulation under dark and gamma irradiation conditions. It will be concluded that this simple method enables us to give an improved wafer evaluation, processing and quality control in the field of photovoltaic materials and other electronic devices.

Uncertainty Assessment using Monte Carlo Simulation in Net Thrust Measurement at AETF

  • Lee, Bo-Hwa;Lee, Kyung-Jae;Yang, In-Young;Yang, Soo-Seok;Lee, Dae-Sung
    • International Journal of Aeronautical and Space Sciences
    • /
    • v.8 no.2
    • /
    • pp.126-131
    • /
    • 2007
  • In this paper, Monte Carlo Simulation (MCS) method was used as an uncertainty assessment tool for air flow, net thrust measurement. Uuncertainty sources of the net thrust measurement were analyzed, and the probability distribution characteristics of each source were discussed. Detailed MCS methodology was described including the effect of the number of simulation. Compared to the conventional sensitivity coefficient method, the MCS method has advantage in the uncertainty assessment. The MCS is comparatively simple, convenient and accurate, especially for complex or nonlinear measurement modeling equations. The uncertainty assessment result by MCS was compared with that of the conventional sensitivity coefficient method, and each method gave different result. The uncertainties in the net thrust measurement by the MCS and the conventional sensitivity coefficient method were 0.906% and 1.209%, respectively. It was concluded that the first order Taylor expansion in the conventional sensitivity coefficient method and the nonlinearity of model equation caused the difference. It was noted that the uncertainty assessment method should be selected carefully according to the mathematical characteristics of the model equation of the measurement.

PIXEL-BASED CORRECTION METHOD FOR GAFCHROMIC®EBT FILM DOSIMETRY

  • Jeong, Hae-Sun;Han, Young-Yih;Kum, O-Yeon;Kim, Chan-Hyeong;Ju, Sang-Gyu;Shin, Jung-Suk;Kim, Jin-Sung;Park, Joo-Hwan
    • Nuclear Engineering and Technology
    • /
    • v.42 no.6
    • /
    • pp.670-679
    • /
    • 2010
  • In this paper, a new approach using a pixel-based correction method was developed to fix the non-uniform responses of flat-bed type scanners used for radiochromic film dosimetry. In order to validate the method's performance, two cases were tested: the first consisted of simple dose distributions delivered by a single port; the second was a complicated dose distribution composed of multiple beams. In the case of the simple individual dose condition, ten different doses, from 8.3 cGy to 307.1 cGy, were measured, horizontal profiles were analyzed using the pixel-based correcton method and compared with results measured by an ionization chamber and results corrected using the existing correction method. A complicated inverse pyramid dose distribution was made by piling up four different field shapes, which were measured with GAFCHROMIC$^{(R)}$EBT film and compared with the Monte Carlo calculation; as well as the dose distribution corrected using a conventional method. The results showed that a pixel-based correction method reduced dose difference from the reference measurement down to 1% in the flat dose distribution region or 2 mm in a steep dose gradient region compared to the reference data, which were ionization chamber measurement data for simple cases and the MC computed data for the complicated case, with an exception for very low doses of less than about 10 cGy in the simple case. Therefore, the pixel-based scanner correction method is expected to enhance the accuracy of GAFCHROMIC$^{(R)}$EBT film dosimetry, which is a widely used tool for two-dimensional dosimetry.

The Measurement of Detachment of Vane Tip in a Positive Displacement Small Vane Pump (압력 평형형 소형 베인펌프에서의 베인 이간 현상 측정)

  • 안형준;양광식;한동철;박민호
    • Proceedings of the Korean Society of Tribologists and Lubrication Engineers Conference
    • /
    • 1998.10a
    • /
    • pp.365-370
    • /
    • 1998
  • This paper reports on the measurement of the vane motion in a positive displacement small vane pump. The capacitive method using ceramic vane is proposed to measure the vane motion. This method enables us to measure only radial motion of the vane regardless of the motions of other directions. With simple experiments and solutions of simultaneous equations, the indirect compensation of measured signal was performed.

  • PDF

A Study on Successive Approximation Measurement of Mechanical Parameters for Motor Control System (전동기 제어시스템 기계정수의 점근적 추정에 관한 연구)

  • Ahn Jong-Keon;Park Seung-Kyu;Ahn Ho-Gyun
    • Proceedings of the KIPE Conference
    • /
    • 2001.07a
    • /
    • pp.138-141
    • /
    • 2001
  • This paper presents a study on successive approximation measurement of mechanical parameters for motor control system. At the first step of servo system installation, control system gain tuning is troublesome work. Recently, autotuning method of motion controller for motor drive system is based on parameter measurement and identification. On the case of first order mechanical system (mechanical parameters are modified by simple inertia and friction), it is necessary for good response to get the accurate measurement or identification of the mechanical parameters . In this paper, novel method applies the binary successive approximation measurement to the inertia and friction coefficient. Computer simulation and experiment for the proposed method will show verification of accuracy and usefulness.

  • PDF

A Study on Successive Approximation Measurement of Mechanical Parameters for Motor Control System (축차비교를 이용한 전동기 기계정수 추정에 관한 연구)

  • Ahn, Jong-Keon;Paek, Yoon-Hyeok;Park, Seung-Kyu;Ahn, Ho-Gyun
    • Proceedings of the KIEE Conference
    • /
    • 2001.10a
    • /
    • pp.165-167
    • /
    • 2001
  • This paper presents a study on successive approximation measurement of mechanical parameters for motor control system. At the first step of servo system installation, control system gain tuning is troublesome work. Recently, auto-tuning method of motion controller for motor drive system is based on parameter measurement and identification. On the case of first order mechanical system (mechanical parameters are modified by simple inertia and friction), it is necessary for good response to get the accurate measurement or identification of the mechanical parameters. In this paper, novel method applies the binary successive approximation measurement to the inertia and friction coefficient. Computer simulation and experiment for the proposed method will show verification of accuracy and usefulness.

  • PDF