References
- A. Sankar, et al., “Comparison of Kodak EDR2 and Gafchromic EBT Film for Intensity-modulated Radiation Therapy Dose Distribution Verification,” Med Dosim., 31, 273 (2006). https://doi.org/10.1016/j.meddos.2006.06.001
- M. Fuss, E. Sturtewagen, C. D. Wagter, and D. Georg, “Dosimetric Characterization of GafChromic EBT Film and Its Implication on Film Dosimetry Quality Assurance,” Phys. Med. Biol., 52, 4211 (2007). https://doi.org/10.1088/0031-9155/52/14/013
- S. Devic, et al., “Precise Radiochromic Film Dosimetry using a Flat-bed Document Scanner,” Med. Phys., 32, 2245 (2005). https://doi.org/10.1118/1.1929253
-
C. Fiandra, et al., “Clinical Use of EBT Model
$Gafchromic^{TM}$ Film in Radiotherapy,” Med. Phys., 33, 4314 (2006). https://doi.org/10.1118/1.2362876 - L. Menegotti and A. Delana, “Radiochromic Film Dosimetry with Flatbed Scanners: A Fast and Accurate Method for Dose Calibration and Uniformity Correction with Single Film Exposure,” Med. Phys., 35, 3078 (2008). https://doi.org/10.1118/1.2936334
-
E. E. Wilcox and G. Daskalov, “Evaluation of
$GAFCHROMIC^{\circledR}$ EBT Film for$CyberKnife^{\circledR}$ Dosimetry,” Med. Phys., 34, 1967 (2007). https://doi.org/10.1118/1.2734384 - ISP Paper: http://www.ispcorp.com/products/dosimetry/content/gafchromic/content/products/ebt/pdfs/EffectLight.pdf.
- Product manual: http://online1.ispcorp.com/_layouts/Gafchromic/content/products/ebt/pdfs/EBTwhitepaper.pdf.
- L. J. Van Battum, D. Hoffmans, H. Piersma, and S. Heukelom, “Accurrate Dosimetry with GafchromicTMEBT Film of a 6 MV Photon Beam in Water: What Level is Achievable?,” Med. Phys., 35, 704 (2008). https://doi.org/10.1118/1.2828196
- T. Depuydt, A. Van Esch, and D. P. Huyskens, “A quantitative evaluation of IMRT dose distributions: Refinement and clinical assessment of the gamma evaluation,” Radiother. Oncol., 62, 309 (2002). https://doi.org/10.1016/S0167-8140(01)00497-2
- S. Both et al., “A study to establish reasonable action limits for patient-specific quality assurance in intensitymodulated radiation therapy,” J. Appl. Clin. Med. Phys., 8, 1 (2007)
- B. E. Nelms and J. A. Simon, “A survey on planar IMRT QA analysis,” J. Appl. Clin. Med. Phys., 8, 76 (2007).
- Y. S. Yoo, and S. G. Ro, “Gamma-ray Dosimetry with Thin Plastic Film,” Nucl. Eng. & Tech., 5, 223 (1973).
- Y. S. Yoo, “Electron Dose Measurement with Polycarbonate Film Dosimeter,” Nucl. Eng. & Tech., 8, 9 (1976).
- O. A. Zeidan, et al., “Characterization and Use of EBT Radiochromic Film for IMRT Dose Verification,” Med. Phys., 33, 4064 (2006). https://doi.org/10.1118/1.2360012
- M. Todorovic, M. Fischer, F. Cremers, E. Thom, and R. Schmidt, “Evaluation of GafChromic EBT Prototype B for External Beam Dose Verification,” Med. Phys., 33, 1321 (2006). https://doi.org/10.1118/1.2188077
- E. E. Wilcox, G. Daskalov, and L. Nedialkova, “Comparison of the Epson Expression 1680 Flatbed and the Vidar VXR-16 Dosimetry PROTM Film Scanners for Use in IMRT Dosimetry Using Gafchromic and Radiographic Film,” Med. Phys., 34, 41 (2006).
- L. Paelinck, W. D. Neve, and C. D. Wagter, “Precautions and Strategies in Using a Commercial Flatbed Scanner for Radiochromic Film Dosimetry,” Phys. Med. Biol., 52, 231 (2007). https://doi.org/10.1088/0031-9155/52/1/015
-
M. Martisíkova, B. Ackermann, and O. JAkel, “Analysis of Uncertainties in
$Gafchromic{\circledR}$ EBT Film Dosimetry of Photon Beams,” Phys. Med. Biol., 53, 7013 (2008). https://doi.org/10.1088/0031-9155/53/24/001
Cited by
- Quantitative analysis of dose distribution to determine optimal width of respiratory gating window using Gafchromic EBT2 film vol.62, pp.4, 2013, https://doi.org/10.3938/jkps.62.657