• 제목/요약/키워드: signal

검색결과 32,641건 처리시간 0.045초

공구마멸주건에서 AE 신호의 특성 (Charactcristics of AE Signal in Tool Wear Condition)

  • 임진규;강명창;김정석
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 1993년도 추계학술대회 논문집
    • /
    • pp.58-63
    • /
    • 1993
  • The charactistics of AE(Acoustic Emission) signal is related to cutting conditions, tool materials and tool geometry in metal cutting. The tool geometry change which is derived from tool wear affects the source of AE signal in machining process. The relationship between AE signal and tool wear was experimentally investigated. THe value of RMS(Root Mean Sequare) and Amplitude of AE signal were increased in tool wear condition. Also the high value of Count per Hit and Count vs. Frequency was observed in this condtion. As a result, tool wear can be effectively detected by AE signal during cutting operation.

  • PDF

지역 교통망 관리를 위한 최적 신호순서에 관한 연구 (A Study on the Optimal Signal Timing for Area Traffic Control)

    • 한국경영과학회지
    • /
    • 제24권2호
    • /
    • pp.69-80
    • /
    • 1999
  • A genetic algorithm to determine the optimal signal sequence and double cycle pattern is described. The signal sequence and double cycle pattern are used as the input for TRANSYT to find optimal signal timing at each junction in the area traffic networks, In the genetic process, the partially matched crossover and simple crossover operators are used for evolution of signal sequence and double cycle pattern respectively. A special conversion algorithm is devised to convert the signal sequence into the link-stage assignment for TRANSYT. Results from tests using data from an area traffic network in Leicester region R are given.

  • PDF

Design of ICA to Extract Respiration Signal From PPG Signal

  • Lee, Ju-Won;Lee, Byeong-Ro
    • Journal of information and communication convergence engineering
    • /
    • 제9권2호
    • /
    • pp.220-223
    • /
    • 2011
  • Respiration signal of the vital signs is an important parameter in clinical parts. To extract the respiration signal from PPG signal for mobile healthcare system is difficult because the bands of the motion artifacts and respiration in the frequency domain are overlapped. This study to improve this problem suggested a respiration extraction method using the independent component analysis and evaluated its performances. In results of evaluation, the ICA method showed better performance than LPF suggested recently.

FPGA를 이용하여 다양한 클럭 데이터 전송 (The Transmission of Random Clock Data using FPGA)

  • 김윤권;신형승;정제명
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2006년 학술대회 논문집 정보 및 제어부문
    • /
    • pp.385-387
    • /
    • 2006
  • We made the logic that can transmit the service data and clock of interest by using the optical signal and demodulate the original signal at the receiving end. Because We can interface the all communications equipment to which We intended to send the signal. We can modulate the dock and clocked data using optical signal and then transmit the original optical signal to the receiving end, finally, arbitrarily control the traffic between ports.

  • PDF

하드디스크 슬라이더의 부상 특성과 AE신호의 관계 (Relationship between Take-off Behavior of Hard-disk Slider and AE Signal)

  • 이상민;문재택;김대은
    • Tribology and Lubricants
    • /
    • 제17권1호
    • /
    • pp.40-55
    • /
    • 2001
  • Acoustic emission(AE) signal has been widely utilized to monitor the interaction at the head/disk interface. In this work the relationship between the AE signal and the state of contact between the slider and the disk is presented. Results of the FFT(Fast Fourier Transform) analyses of the AE signal could be used to better understand the interfacial interaction. Also, it was found that wear particles affect the AE signal. Therefore, the signal can be used to monitor the wear particle presence at the interface.

광 SCM 전송방식에서 MZ 변조기를 통과한 DS-CDMA 신호의 성능분석 (Performance Analysis of DS-CDMA Signal through MZ Modulator in optical SCM Signal Transmission)

  • 김회준;임명섭
    • 대한전자공학회:학술대회논문집
    • /
    • 대한전자공학회 2001년도 하계종합학술대회 논문집(1)
    • /
    • pp.77-80
    • /
    • 2001
  • In this paper, it is analyzed the statistical characteristics on the transmission performance of the optical SCM transmission in the CDMA RF signal relay system. Using Mach-Zehnder modulator, optical signal is regenerated into CDMA RF signal. Transfer function model of mach-Zehnder modulator is approximated to the third power of the input signal using Taylor series. BER results are analyzed under the multiple access interference and multi-path fading environment.

  • PDF

잡음 감소를 위한 창 함수의 선택에 관한 연구 (Appropriate Choice of Window Function for Noise Reduction)

  • 백문열
    • 한국안전학회지
    • /
    • 제12권4호
    • /
    • pp.3-8
    • /
    • 1997
  • This paper shows a performance estimation of windowing a single tone with added Gaussian noise and uniform noise. Signal-to-noise ratio can be determined by the ratio of the output noisy signal variance to the input noisy signal variance of a window. Standard deviation of noise is reduced by windowing Signal-to-noise ratio of the noisy signal is reduced by the windowing operation. Thus, performance of window function can be determined by this filtering operation that improved the signal-to-noise ratio.

  • PDF