• Title/Summary/Keyword: shut-off valve

Search Result 53, Processing Time 0.025 seconds

Performance Analysis of Emergency Shut-Off Safety Valve (긴급차단용 안전밸브의 성능해석)

  • Song, H. Y.;Park, K. A.;Ko, S.
    • 유체기계공업학회:학술대회논문집
    • /
    • 2001.11a
    • /
    • pp.413-418
    • /
    • 2001
  • Emergency shut-on valve was developed to shut off natural gas at the front of a gas meter in the house. The shut-off flow rate and differential pressure of this valve was controlled by adjusting the distance between the spool and magnet. Also the spool shape was an important factor in the performance of this valve. The experimental and computational results will be useful for the design having better performance.

  • PDF

Design Study of Automatic Cut-off Horizontal Valve for a LPG Cylinder (LP가스용 차단기능형 수평식 용기밸브에 대한 설계연구)

  • Kim, Chung Kyun
    • Journal of the Korean Institute of Gas
    • /
    • v.19 no.6
    • /
    • pp.80-84
    • /
    • 2015
  • In this paper, the valves for a LPG gas cylinder have been investigated on the body height and weight by comparing design data between typical automatic shut-off vertical and newly developed horizontal valves. The height of an automatic shut-off horizontal valve is radically reduced by 41~42% compared with that of a typical automatic shut-off vertical valve. And, the body weight of a horizontal valve is also reduced by 29~40% compared with that of a vertical shut-off valve. This result is just achieved by a structural design modification from typical vertical valve to horizontal arrangement of various valve components.

Risk Analysis for Installation Types of Pressure Safety Valve used in the High-pressure Gas Facility (고압가스 사용시설 내 안전밸브 설치유형별 리스크 분석)

  • Kim, Myung-Chul;Woo, Jeong-Jae;Lee, Hyung-Sub;Baek, Jong-Bae
    • Journal of the Korean Society of Safety
    • /
    • v.32 no.4
    • /
    • pp.129-136
    • /
    • 2017
  • This study investigated the probability of possible accident through qualitative and quantitative analysis of the pressure safety valve types installed in facilities using high pressure gas to compare the installation domestic and foreign pressure safety valve standards sought the safety characteristics and safety improvement direction accordingly. The three types are the case where the shut-off valve is not installed at the front of the PSV (Case A), If a shut-off valve is installed at the front of the PSV for inspection (Case B) and If a shut-off valve is installed in front of PSV (C.S.O), PSV is installed in parallel (Case C). Three types of cases were compared with FTA and HAZOP. The results of study of the possible accidents due to over-pressure safety valve installation type, used in a high-pressure gas facilities was shows in the following order Case B > Case A > Case C. The results of analysis through FTA was in order to protect the reservoir for the possible occurring of accident the safety valve installation is depend on its type. In the FTA analysis, defects in the device itself which attached to the storage tank as a substitute for analysis of the probability of operator mistakes was Case B with as high as $2.01{\times}10^{-6}$. Depending on the type of installation analysis of Case B in order to ensure safety is prohibited to install shut-off valve and believes that mandatory regulations are needed. Rationally installing of pressure safety valve in the high pressure using facilities will be expected to improve the industrial safety from severe accidents such as high-pressure gas fire explosion.

Development of a Two-Step Main Oxidizer Shut-off Valve (2단계 개방 연소기 산화제 개폐밸브 개발)

  • Hong, Moongeun
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.45 no.8
    • /
    • pp.704-710
    • /
    • 2017
  • The supply of the liquid oxygen into a rocket combustor is simply controlled by the 'on' and 'off' positions of a main oxidizer shut-off valve. However, the partially opened position of a three-position valve can control and optimize the engine start transients by regulating the liquid oxygen flow rate during the start-up of the engine. In this paper, the design and performances of a three-position pneumatic poppet valve, which is intended to be employed in liquid rocket engines, have been presented.

A Study on the Internal Flow Analysis of High-pressure Shut-off Valve for CNG Charging Station Piping System (CNG 충전소 배관시스템용 고압 차단밸브에 대한 내부 유동해석에 관한 연구)

  • Chin, Do-Hun
    • Journal of the Korean Society of Industry Convergence
    • /
    • v.24 no.6_2
    • /
    • pp.773-779
    • /
    • 2021
  • CNG, which has recently been attracting attention as an alternative fuel in the transportation field to reduce emissions caused by global warming, is natural gas with abundant reserves and mainly composed of methane. Being in a gaseous state, natural gas requires the compression and liquefaction processes for transportation. Until now, general shut-off valves for liquid and gas piping have been developed in Korea, but there are few studies on shut-off valves for high pressures of about 200 bar. Currently, research on the flow analysis of valves is being actively conducted around the world. However, there are relatively many studies on large valves such as low-pressure valves or shipbuilding and marine, and the safety factor through structural analysis to check the structural integrity of the valve is checked at the design stage. Since it is necessary to have a fast response speed while minimizing pressure and speed loss due to flow change, basic research was conducted on the flow analysis of the valve to secure design data, and the numerical analysis was performed on high-pressure automatic shut-off valves applied to CNG refueling stations. After securing the basic valve shape through reverse engineering for advanced products, we compared the valve flow coefficient Cv coefficient with advanced products. As a result, it was found that the reverse engineering model was at the level of about 60%. However, we compared the Cv coefficient by modifying the reverse engineering model, and the result showed that it was improved to about 96%.

A Numerical Study on Thermal Analysis of Fuel Shut-off Valve (연료차단밸브의 열해석에 관한 수치적 연구)

  • Baek, Nak-Gon;Lee, Jae-Yun
    • Journal of the Korean Society of Propulsion Engineers
    • /
    • v.16 no.5
    • /
    • pp.108-114
    • /
    • 2012
  • Thermal and fluid flow characteristics in a fuel shut-off valve under operating conditions are studied numerically. The disk size of the valve has 15 mm diameters and maximum mass flow rate is 600 kg/h. The Analysis was performed in the commercial code, STAR-CCM+. This paper shows that results from the numerical analysis has a good agreement compared to experimental results.

A Numerical Study on Thermal Analysis of Fuel Shut-off Valve (연료차단밸브의 열해석에 관한 수치적 연구)

  • Baek, Nak-Gon;Lee, Jae-Yun
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2011.11a
    • /
    • pp.559-564
    • /
    • 2011
  • Thermal and fluid flow characteristics in a fuel shut-off valve under operating conditions are studied numerically. The disk size of the valve has 15mm diameters and maximum mass flow rate is 600 kg/h. The Analysis was performed in the commercial code, STAR-CCM+. This paper shows that results from the numerical analysis has a good agreement compared to experimental results.

  • PDF

A Study on the Prevention of Spill of Fuel Oils and Lubricating Oils for Sunken Ships

  • Han, Won-Heui;Ju, Hae-Ji
    • Journal of the Korean Society of Marine Environment & Safety
    • /
    • v.21 no.3
    • /
    • pp.309-314
    • /
    • 2015
  • A sunken ship often involves an oil spill. This paper was carried out to minimize environmental and cost damages stemming from oil spil of sunken shipl. Through the analysis of both the standards of the oil tank system and installation, we have identified potential oil spill sites and proposed a remedy of prevention. The result of study, the air pipes of the oil tank are a vulnerable point for oil spill. Also, the remote control devices of emergency shut-off valve have poor accessibility at abandon ship, making it difficult to shut off the emergency shut-off valve. Thus, we propose the addition of a remote quick closing valve in the air pipe and the building of a central control system.

Structural Evaluations of Bellows for a Gasgenerator Lox Shut-off Valve (가스발생기 산화제 개폐밸브용 벨로우즈 구조 평가)

  • Yoo, Jae-Han;Lee, Joong-Youp;Lee, Soo-Yong
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2011.04a
    • /
    • pp.279-282
    • /
    • 2011
  • The analysis and experimental results for the bellows of gasgenerator liquid oxygen shut-off valve are presented. The analyses are performed using EJMA (Expansion Joint Manufacturing Association) standard and the commercial FE (finite element) analysis program, Abaqus v6.9, at room and cryogenic temperatures. The results include the spring rate, the stress and the fatigue life of the bellows. The effects of the contact and material plasticity on the FE analysis results are also analyzed.

  • PDF

Opening Characteristics of a Main Oxidizer Shut-off Valve (연소기 산화제 개폐밸브 개방 특성)

  • Hong, Moongeun
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.45 no.11
    • /
    • pp.989-997
    • /
    • 2017
  • We study opening transient responses of a self-sustainable poppet valve, which is usually used for the main oxidizer shut-off valve of liquid rocket engines. In order to perform numerical analysis, a pneumatic supply system was simulated as an orifice with a diameter of 3.2 mm and the equations of motion of valve moving part were derived. For the validation of the study, a comparison of numerical predictions and experimental results has been done. As one of the practical applications of this study, the employment of an orifice in a high pneumatic pressure has been presented to control the valve opening time.