• Title/Summary/Keyword: shim coil

Search Result 63, Processing Time 0.028 seconds

Electroactive Polymer Actuator for Lens-Drive Unit in Auto-Focus Compact Camera Module

  • Lee, Hyung-Kun;Choi, Nak-Jin;Jung, Sun-Kyung;Park, Kang-Ho;Jung, He-Won;Shim, Jae-Kyu;Ryu, Jae-Wook;Kim, Jong-Dae
    • ETRI Journal
    • /
    • v.31 no.6
    • /
    • pp.695-702
    • /
    • 2009
  • We propose a lens-drive unit composed of an ionic polymer-metal composite (IPMC) for an auto-focus compact camera module in cellular phones to solve the power consumption problem of voice coil motors which are widely used in commercial products. In this research, an IPMC incorporated into a lens-drive unit is designed to implement a large displacement in low-power consumption by using an anisotropic plasma treatment. Experimental results show that a camera module containing IPMCs can control and maintain the position of the lens by using proportional integral derivative control with a photo-reflective position sensor despite the non-linear actuation behavior of IPMCs. We demonstrate that the fabrication and commercialization of a lens actuator that has a large displacement and low power consumption using IPMCs is possible in the near future.

Multi-physics Topology Optimization of High Efficiency Motor Considering Electromagnetics and Heat Transfer (전자기와 열전달을 고려한 고효율 모터의 다분야 위상최적설계)

  • Wang, Se-Myung;Shim, Ho-Kyoung;Moon, Hee-Gon;Cho, Yang-Hee;Kim, Myung-Kyu
    • Proceedings of the KSME Conference
    • /
    • 2004.04a
    • /
    • pp.1058-1063
    • /
    • 2004
  • This paper presents a new approach regarding thermal characteristics associated with a design of the high efficiency motor. Electrical conduction materials, such as coil and aluminum embedded in the core generate high heat exerting negative influence on both lifetime and performance of machine. Thus, it is necessary to design high efficiency motor considering heat transfer in order to improve motor performance and to be protected against overheating. In this paper, firstly, numerical analysis of electromagnetic field is carried out by the nonlinear transient finite element method (FEM). Secondly, the linear static FEA of magneto-thermal field is implemented by applying source current computed by the nonlinear transient analysis. FE results are validated in terms of electromagnetics and heat transfer by experiments. And then, the pseudo-transient topology optimization using a multi-objective function is performed. The proposed method is applied to a squirrel cage single-phase induction motor of the scroll compressor.

  • PDF

A Development of Experimental Model Prediction of Leakage Pressure in MPW (전자기 펄스 용접시 누수압력을 예측하기 위한 실험모델의 개발)

  • Shim, Ji-Yeon;Kim, Ill-Soo;Kim, In-Ju;Kang, Bong-Yong
    • Journal of the Korean Society of Manufacturing Technology Engineers
    • /
    • v.18 no.6
    • /
    • pp.652-657
    • /
    • 2009
  • MPW(Magnetic Pulse Welding) is a technologies for welding of metals by means of repulsive force on account of the interaction between electro-magnetic field of coil and current induced in outer pipe. These MPW is one of the most useful welding process of welding ability of the dissimilar metal in which cylindrical materials, such as pipe, tube. As the quality of a weld joint is strongly influenced by process parameters during the welding process and the success of the welding to evaluated according to the leakage pressure. Generally, the process parameters is magnetic pressure, the gap between outer pipe and inner pipe, and the ratio of thickness to diameter of pipe(D/T) in MPW. Therefore, the goal of this study was to explain the effect of parameters on the weld joint leakage pressure. For these purposes, FFD(Fractional Factorial Design) were used for the experiment. The measured data were analyzed by regression analysis and verification experiments with random condition were conducted to confirm the suggested experimental model.

  • PDF

Measuring T1 contrast in ex-vivo prostate tissue at the Earth's magnetic field

  • Oh, Sangwon;Han, Jae Ho;Kwon, Ji Eun;Shim, Jeong Hyun;Lee, Seong-Joo;Hwang, Seong-Min;Hilschenz, Ingo;Kim, Kiwoong
    • Journal of the Korean Magnetic Resonance Society
    • /
    • v.23 no.1
    • /
    • pp.12-19
    • /
    • 2019
  • A former study has shown that the spin-lattice relaxation time ($T_1$) in cancerous prostate tissue had enhanced contrast at an ultra-low magnetic field, $132{\mu}T$. To study the field dependence and the origin of the contrast we measured $T_1$ in pairs of ex-vivo prostate tissues at the Earth's magnetic field. A portable and coil-based nuclear magnetic resonance (NMR) system was adopted for $T_1$ measurements at $40{\mu}T$. The $T_1$ contrast, ${\delta}=1-T_1$ (more cancer)/$T_1$(less cancer), was calculated from each pair. Additionally, we performed pathological examinations such as Gleason's score, cell proliferation index, and micro-vessel density (MVD), to quantify correlations between the pathological parameters and $T_1$ of the cancerous prostate tissues.

Endovascular Treatment of Aortic Dissection due to Suture Line Dehiscence after Aortic Graft Replacement for Type A Aortic Dissection: A Report of Two Cases (A형 대동맥박리의 대동맥 이식편 치환술 후 봉합선 열개의 혈관내 치료: 2건의 증례 보고)

  • Woo Jin Shim;Young Hwan Kim
    • Journal of the Korean Society of Radiology
    • /
    • v.85 no.3
    • /
    • pp.668-675
    • /
    • 2024
  • Aortic anastomotic leak is an uncommon complication after ascending aortic replacement for acute aortic dissection. Redo-surgery is the traditional standard treatment despite high mortality and morbidity. Recently, endovascular treatment has been attempted as an alternative approach in a few case reports. Here, we present two cases of aortic anastomotic leak due to suture line dehiscence after aortic graft replacement for type A aortic dissection, which were successfully treated by coil with subsequent N-butyl cyanoacrylate embolization and an AmplatzerTM vascular plug.

Development of Heat Dissipation Measuring System for 1.2-kW BLDC Motor (1.2kW 급 BLDC 모터의 열 발산 측정 시스템 개발)

  • Lee, Injun;Ye, Jungwoo;Lee, Daehun;Hwang, Pyung;Shim, Jaesool
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.37 no.11
    • /
    • pp.1423-1428
    • /
    • 2013
  • In this study, a heat dissipation measurement system is developed to analyze a 1.2-kW BLDC motor. It is important to check the temperature of the motor because an increase in temperature causes problems in the motor insulations, which in turn influences the motor life. A generator for a vehicle is installed to set up a load. We changed the load from 165 to 495 W. While the rpm varies from 2000 to 4000 under various load conditions, the changes in temperature were measured for the operating period by using a thermocouple. The results of experiments conducted under natural convection conditions suggest that the temperature was not stationary with the rpm, load, and coil of the motor and it kept increasing over $120^{\circ}C$. However, under forced convection conditions, the temperature stationarily reached $84^{\circ}C$ after 4000 s. The difference between the maximum and the minimum temperatures was $10-26^{\circ}C$ with an increase in the rpm and load. The orders of high temperature were as follows: motor coil (Ch#1), side of motor surface (Ch#5), inside of motor cap (Ch#2), upper side of motor surface (Ch#4), and inner wall of the motor (Ch#3).

Development of stimulator for peripheral disturbance therapy using A variable Micro-electromagnetic (미약 전자기장을 이용한 말초장애 치료시스템 개발)

  • Kim, Soo-Byung;Lee, Seung-Wook;Shim, Ta-Kyu;Lee, Na-Ra;Lee, Yong-Heum
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.14 no.5
    • /
    • pp.1209-1216
    • /
    • 2010
  • It has increased that peripheral disturbance(blood flow, nerve, Raynaud's phenomenon) and finger rheumatoid arthritis which is caused by the diabetic complications. To improve these pain issues, we proposed new method for the Finger Disease Therapy(FDT). In this paper, we manufactured solenoid cylindrical coil which was only for the FDT using a variable micro-electromagnetic. Also, we designed the Finger Disease Therapy System(FDTS) which could select three stimulation modes(N_pulse, S_pulse, N/S_pulse) and frequency(0.25hz, 0.5hz, 1hz). We used a Teslameter to measure magnetic flux inner solenoid, and measured magnetic flux as distance(0 ~ 3cm) inner solenoid with stimulation modes and frequency. In the results, magnetic flux was the highest in center of solenoid(0cm) for all stimulation modes. Also, the highest magnetic flux was measured as N_pulse(294.3mT), S_pulse(293.8mT) in 1Hz and N/S_pulse (275.4mT) in 0.25Hz, respectively. Therefore, we developed the FDTS using various pattern and intensity for finger diseases therapy, and checked therapy clinic application possibility of the FDTS as measuring magnetic flux inner solenoid.

Comparison of Long-Term Angiographic Results of Wide-Necked Intracranial Aneurysms : Endovascular Treatment with Single-Microcatheter Coiling, Double-Microcatheter Coiling, and Stent-Assisted Coiling

  • Kim, Hyun Sik;Cho, Byung Moon;Yoo, Chan Jong;Choi, Dae Han;Hyun, Dong Keun;Shim, Yu Shik;Song, Joon Ho;Oh, Jae Keun;Ahn, Jun Hyong;Kim, Ji Hee;Chang, In Bok
    • Journal of Korean Neurosurgical Society
    • /
    • v.64 no.5
    • /
    • pp.751-762
    • /
    • 2021
  • Objective : Endovascular treatment of intracranial aneurysms is challenging in case of wide-necked aneurysms because coils are prone to herniate into the parent artery, causing thromboembolic events or vessel occlusion. This study aims to compare long-term angiographic results of wide-necked aneurysms treated by stent-assisted, double-microcatheter, or single-microcatheter groups. Methods : Between January 2003 and October 2016, 108 aneurysms that were treated with endovascular coil embolization with a neck size wider than 4 mm and a follow-up period of more than 3 years were selected. We performed coil embolization with single-microcatheter, double-microcatheter, and stent-assisted techniques. Angiographic results were evaluated using the Raymond-Roy occlusion classification (RROC). All medical and angiographic records were reviewed retrospectively. Results : Clinical and angiographic analyses were conducted in 108 wide-necked aneurysms. The immediate post-procedural results revealed RROC class I (complete occlusion) in 66 cases (61.1%), class II (residual neck) in 36 cases (33.3%), and class III (residual sac) in six cases (5.6%). The final follow-up results revealed class I in 48 cases (44.4%), class II in 49 cases (45.4%), and class III in 11 cases (10.2%). Of a total of 45 (41.6%) radiologic recurrences, there were 21 cases (19.4%) of major recurrence that required additional treatment, and 24 cases (22.2%) of minor recurrence. The final follow-up angiographic results showed statistically significant differences between the stent-assisted group and the others (p<0.01). Conclusion : Long-term follow-up angiography demonstrated that the stent-assisted technique had a better complete occlusion rate than the other two techniques.

Clinical Outcomes of Coil Embolization for Unruptured Intracranial Aneurysms Categorized by Region and Hospital Size : A Nationwide Cohort Study in Korea

  • Bong-Gyu Ryu;Si Un Lee;Hwan Seok Shim;Jeong-Mee Park;Yong Jae Lee;Young-Deok Kim;Tackeun Kim;Seung Pil Ban;Hyoung Soo Byoun;Jae Seung Bang;O-Ki Kwon;Chang Wan Oh
    • Journal of Korean Neurosurgical Society
    • /
    • v.66 no.6
    • /
    • pp.690-702
    • /
    • 2023
  • Objective : To analyze the outcomes of coil embolization (CE) for unruptured intracranial aneurysm (UIA) according to region and hospital size based on National Health Insurance Service data in South Korea. Methods : The incidence of complications, including intracranial hemorrhage (ICRH) and cerebral infarction (CI), occurring within 3 months and the 1-year mortality rates in UIA patients who underwent CE in 2018 were analyzed. Hospitals were classified as tertiary referral general hospitals (TRGHs), general hospitals (GHs) or semigeneral hospitals (sGHs) according to their size, and the administrative districts of South Korea were divided into 15 regions. Results : In 2018, 8425 (TRGHs, 4438; GHs, 3617; sGHs, 370) CEs were performed for UIAs. Complications occurred in 5.69% of patients seen at TRGHs, 13.48% at GHs, and 20.45% at sGHs. The complication rate in TRGHs was significantly lower than that in GHs (p=0.039) or sGHs (p=0.005), and that in GHs was significantly lower than that in sGHs (p=0.030). The mortality rates in TRGHs, GHs, and sGHs were 0.81%, 2.16%, and 3.92%, respectively, with no significant difference. Despite no significant difference in the mortality rates, the complication rate significantly increased as the number of CE procedures per hospital decreased (p=0.001; rho=-0.635). Among the hospitals where more than 30 CEs were performed for UIAs, the incidence of CIs (p=0.096, rho=-0.205) and the mortality rates (3 months, p=0.048, rho=-0.243; 1 year, p=0.009, rho=-0.315) significantly decreased as the number of CEs that were performed increased and no significant difference in the incidence of post-CE ICRH was observed. Conclusion : The complication rate in patients who underwent CE for UIA increased as the hospital size and physicians' experience in conducting CEs decreased. We recommend nationwide quality control policies CEs for UIAs.

A STUDY OF EFFECT OF PULSED ELECTROMAGNETIC FIELDS ON OSTEOGENESIS IN RABBIT CRANIAL BONE DEFECT (가토 두개부 골결손에서 맥동전자기장이 골형성에 미치는 영향에 관한 연구)

  • Hwang, Kyung-Gyun;Lee, Jong-Hwan;Kim, Myung-Jin;Shim, Kwang-Sup;Kim, Jong-Won
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • v.28 no.4
    • /
    • pp.264-273
    • /
    • 2002
  • Pulsed electromagnetic field (PEMF) was used first to induce osteogenesis in 1974. The appliance which was consisted of the Helmholtz coil configuration have used to osteogensis. The objective of this study was to determine whether PEMF, a frequency of 100 Hz and magnetic field strength of 38 gauss applied to the calvarial defect in rabbit, could affect the induction of osteogenesis and the healing of the graft bone. This field should not produce excitation of nerve or muscle and heating the tissue. To evaluate the effect of PEMF on osteogenesis, 16 rabbit under the same condition was divided into 8 experimental groups and 8 control groups. 10 mm calvarial bone defects were formed around sagittal suture. The defect of left side was left without graft while the defect of right side was grafted by bone harvested from left side. A pulsed electromagnetic field was applied for 8 hours per day. Each group was sacrificed after 1 week, 2 weeks, 4 weeks, 8 weeks. Microscopic specimens were obtained from the calvarial bone defects and surrounding tissue using Hematoxylin-Eosin staining method. The results were as follows. 1. In the group which pulsed electromagnetic field was applied, new bone formation filled up the defect was observed after 4 and 8 weeks effectively. 2. There are no difference in the healing period for the fusion between the bone and graft bone. According to the result, the PEMF with 38 Gauss, 100 Hz was very effective in the healing of bone defect and new bone formation. So The PEMF will be useful in clinical aspect for oseteogenesis.