유한요소법에 의한 전위치차의 강도해석 (Strenth analysis gear by finite element method)

  • 조선휘;박종근
    • 오토저널
    • /
    • 제3권2호
    • /
    • pp.27-33
    • /
    • 1981
  • In the paper, it was attempted to verify how the strength around fillet area of shifted gear would be affected by variables such as number of teeth, shifted value, and diametral pitch. Thereafter, the Lewis' tooth factor of the shifted gear was computed in terms of previously mentioned variables in order to observe the characteristics of stress change related from tooth factor and tooth number with the parameter of shifted values and diametral pitches. From the results of quasi-theoretical values by Finite Element Method(F.E.M.)and experimental values through the photo-elastic tests, the followings were identified. The more the number of gear teeth increased, the more the profile of the tooth became close to that of rack, and accordingly the stresses in the fillet area decreased significantly in certain range. Furthermore, as the shifted value and pressure angle increase the stresses tend decrease. Moreover, the stresses analyzed by F.E.M. in the filled area became around 1.22 times larger than the stresses computed by Lewis' form factor, and this is supposed as on influence of the stress concentration in fillet area.

  • PDF

A Voltage-fed Single-stage PFC Full-bridge Converter with Asymmetric Phase-shifted Control for Battery Chargers

  • Qian, Qinsong;Sun, Weifeng;Zhang, Taizhi;Lu, Shengli
    • Journal of Power Electronics
    • /
    • 제17권1호
    • /
    • pp.31-40
    • /
    • 2017
  • A novel voltage-fed single-stage power factor correction (PFC) full-bridge converter based on asymmetric phase-shifted control for battery chargers is proposed in this paper. The attractive feature of the proposed converter is that it can operate in a wide output voltage range without an output low-frequency ripple, which is indispensable in battery charger applications. Meanwhile, the converter can maintain a high power factor and a controllable dc bus voltage over a wide output voltage range. In this paper, the realization of PFC and the operation principle of asymmetric phase-shifted control are given. A small-signal analysis of the proposed single-stage power factor correction (PFC) full-bridge converter is performed. Experimental results obtained from a 1kW experimental prototype are given to validate the feasibility of the proposed converter. The PF is higher than 0.97 over the entire output voltage range with the proposed control strategy.

다축차동장치의 전위기어 해석 (Profile-shifted Gears in Multi-axial Differential System)

  • 강동수;송철기
    • 한국정밀공학회지
    • /
    • 제28권5호
    • /
    • pp.632-637
    • /
    • 2011
  • A new tooth profile which is adjusted on the amount of addendum modification factor is proposed for reducing vibration and noise of gears. The transmission error of the new profile can be designed more uniformly than that of the standard involute profile. The basic concepts of tooth profile modification are to reduce the load in contact area and to find the appropriate profile modification factor for operation condition. In this study, gears were estimated to constructive safety of bending strength and contact strength durability by using ROMAX program, and were compared with results by design formula of AGMA standard.

A High Performance Three-Phase Telecom Supply Incorporating a HF Switched Mode Rectifier with a Phase Shifted PWM Controller

  • Shahani, Arushi;Singh, Bhim;Bhuvaneshwari, G.
    • Journal of Power Electronics
    • /
    • 제10권3호
    • /
    • pp.219-227
    • /
    • 2010
  • Telecom supplies need to conform to low Total Harmonic Distortion (THD) and high Power Factor (PF) as per IEC 61000-3-2 and IEEE 519-1992 standards. These high rating power supplies use a three phase utility in which low THD and high PF are realized via various passive and active wave shaping schemes. In this paper, a new design for three phase telecom power supplies is presented with circuit parameter values optimized for high performance in terms of a low THD, high PF, low ripple and high line and load regulation using a suitable combination of various strategies. The performance of the power supply is validated by extensive simulations.

문턱전류이상에서 구조 및 재료 변수들이 $\lambda$/4위상천이 DFB 레이저의 단일모드 이득차에 미치는 영향 (The Effect of Laser Geometry and Material Parameters on the Single Mode Gain Difference in Quarter Wavelength Shifted DFB Laser above Threshold Current)

  • 이홍석;김홍국;김부균;이병호
    • 전자공학회논문지D
    • /
    • 제36D권3호
    • /
    • pp.75-84
    • /
    • 1999
  • 주입전류가 문턱전류 이상일 때 선폭증가계수, 구속계수, 내부손실과 레이저의 길이가 λ/4 위상천이 DFB레이저의 단일모드 이득차와 발진주파수의 변화에 미치는 영향에 대하여 체계적으로 연구하였다. 구속계수나 선폭증가계수와 구속계수의 곱으로 주어지는 변수보다 선폭증가계수가 단일모드 이득차 및 발진주파수에 미치는 영향이 크다. 내부손실이나 레이저 길이 각각의 값보다 내부손실과 레이저 길이의 곱으로 정의되는 정규화된 내부손실이 DFB 레이저의 단일모드 이득차 및 발진주파수의 변화에 미치는 영향이 크다. 정규화된 내부손실이 같은 경우에는 내부손실계수보다 레이저의 길이가 동작특성에 미치는 영향이 큼을 알 수 있었다. 또한 양자우물 레이저가 builk 레이저에 비하여 선폭증가계수가 작기 때문에 구속계수와 정규화된 내부손실 값의 변화에 따른 단일모드 이득차의 감소와 발진주파수의 변화가 작음을 보았다.

  • PDF

Implementation of a High Efficiency Grid-Tied Multi-Level Photovoltaic Power Conditioning System Using Phase Shifted H-Bridge Modules

  • Lee, Jong-Pil;Min, Byung-Duk;Yoo, Dong-Wook
    • Journal of Power Electronics
    • /
    • 제13권2호
    • /
    • pp.296-303
    • /
    • 2013
  • This paper proposes a high efficiency three-phase cascaded phase shifted H-bridge multi-level inverter without DC/DC converters for grid-tied multi string photovoltaic (PV) applications. The cascaded H-bridge topology is suitable for PV applications since each PV module can act as a separate DC source for each cascaded H-bridge module. The proposed phase shifted H-bridge multi-level topology offers advantages such as operation at a lower switching frequency and a lower current ripple when compared to conventional two level topologies. It is also shown that low ripple sinusoidal current waveforms are generated with a unity power factor. The control algorithm permits the independent control of each DC link voltage with a maximum power point for each string of PV modules. The use of the controller area network (CAN) communication protocol for H-bridge multi-level inverters, along with localized PWM generation and PV voltage regulation are implemented. It is also shown that the expansion and modularization capabilities of the H-bridge modules are improved since the individual inverter modules operate more independently. The proposed topology is implemented for a three phase 240kW multi-level PV power conditioning system (PCS) which has 40kW H-bridge modules. The experimental results show that the proposed topology has good performance.

Basic Study of a Phase-Shifted Soft Switching High-Frequency Inverter with Boost PFC Converter for Induction Heating

  • Kawaguchi, Yuki;Hiraki, Eiji;Tanaka, Toshihiko;Nakaoka, Mutsuo
    • Journal of Power Electronics
    • /
    • 제8권2호
    • /
    • pp.192-199
    • /
    • 2008
  • This paper is mainly concerned with a high frequency soft-switching PWM inverter suitable for consumer induction heating systems. The proposed system is composed of a soft switching chopper based boost PFC converter stage with passive snubber and phase shifted PWM controlled full bridge ZVZCS high frequency inverter stage. Its fundamental operating performances are illustrated and evaluated in the experimental results. Its effectiveness is substantially proved on the basis of the experimental results from a practical point of view.

Effect of Center Frequency Deviation in Miniaturized CMOS Bandpass Filter

  • Kang, In-Ho;Li, Shang-Ming;Guan, Xin
    • 한국항해항만학회지
    • /
    • 제35권4호
    • /
    • pp.299-302
    • /
    • 2011
  • In this letter, the effect of quality factor on center frequency deviation in miniaturized coupled line bandpass filter (BPF) with diagonally end-shorted at their opposite sides and lumped capacitors is theoretically analyzed. The miniaturized BPF of a two-stage structure with two types of quality factors in standard CMOS process was designed and manufactured at 5.5 GHz. The die area of BPF was $1.44{\times}0.41\;mm^2$. The measured center frequency of BPF with a quality factor of 4.9 was deviated from 5.5 GHz to 4.7 GHz. The one with 14.8 was shifted to 5GHz. The theoretical and measured results validate that quality factor influences the center frequency shift of BPF.

General Linearly Constrained Broadband Adaptive Arrays in the Eigenvector Space

  • Chang, Byong Kun
    • Journal of information and communication convergence engineering
    • /
    • 제15권2호
    • /
    • pp.73-78
    • /
    • 2017
  • A general linearly constrained broadband adaptive array is examined in the eigenvector space with respect to the optimal weight vector and the adaptive algorithm. The optimal weight vector and the general adaptive algorithm in the eigenvector space are obtained by eigenvector matrix transformation. Their operations are shown to be the same as in the standard coordinate system except for the relevant transformed vectors and matrices. The nulling performance of the general linearly constrained broadband adaptive array depends on the gain factor such that the constraint plane is shifted perpendicularly to the origin by an increase in the gain factor. The general linearly constrained broadband adaptive array is observed to perform better than a conventional linearly constrained adaptive array in a coherent signal environment, while the former performs similarly to the latter in a non-coherent signal environment.

10Gb/s 광신호의 320km 분산천이 광섬유 전송실험 (Transmission of 10 Gb/s optical signais over 320 km of a dispersion shifted fiber)

  • 이상수
    • 한국광학회지
    • /
    • 제10권1호
    • /
    • pp.64-67
    • /
    • 1999
  • 전송용 고아섬유로 320km의 분산천이 광섬유를 사용하여 10Gb/s 광링크를 구성하고 전송실험을 수행하였다. 광링크는 10Gb/s 광송수신기, 광전력 증폭기, 3개의 광전로 증폭치 증폭기 및 전송용로 구성되어Tdmaum 전송거리에 따른 비트 오율 특성에 대하여 조사하였다. 전송실험 결과 광선로 증폭기의 입력세기가 -18dBm이고, 이득이 28dB인 경우 수신기 입력단에서 측정된 광학적 신호대 잡음비는 28dB로 나타났으며, 광섬유를 사용하지 않은 경우와 비교하여 2dB의 전력 패널티가 발생한 것으로 나타났다. 광섬유 전송 후 발샹한 2dB의 전력 패널티는 광학적 신호대 잡음비 열화에 의해 1dB, 경로 패널티에 의해 1dB가 발생하는 것으로 조사되었다.

  • PDF