• Title/Summary/Keyword: shallow arch

Search Result 59, Processing Time 0.03 seconds

Pull-out Capacity of Cast-in-place Anchor for Construction of Precast Concrete Segment Arch (프리캐스트 콘크리트 패널 분절 아치 시공을 위한 선설치 앵커의 인발 강도 평가)

  • Ahn, Jin-Hee;Yim, Hong Jae;Bang, Jin Soo;Jeon, Seok Hyeon
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.24 no.2
    • /
    • pp.94-102
    • /
    • 2020
  • Precast concrete segment arch system has an economic and construct ability that combined with advantage of precast concrete and arch behavior. A precast concrete segment arch system with outrigger is consisted of segmented precast panels, a steel outrigger rib, and V-strip to connect precast panels with a steel outrigger rib and cast-in-place anchors in precast panels to connect V-strip should have sufficient pull-out capacity to form its arch shape by site lifting for assembled precast panels and outriggers. However, it is difficult to secure its embedment depth due to the relatively shallow thickness of precast panel. It can be also occurred that flexure deformation of precast panels caused by its pull-out behaviors. In this study, pull-out capacity of cast-in-place anchor was examined for construction of precast concrete segment arch system with outriggers. Therefore, a total of 24 precast panel specimens were fabricated to examine pull-out capacities of cast-in-place anchor in precast panels, and installation depth of anchors, diameter of anchors and wire mesh effects for the precast panel were examined. From this pull-out tests, its pull-out capacities and failure modes were evaluated and the type of the cast-in-place anchor applicable to the precast concrete segment panel arch system with outriggers was determined from comparison of the design specification values.

Clinical predictors of potentially impacted canines in low-risk patients: A retrospective study in mixed dentition

  • Sergio Estelita Barros;Bianca Heck;Kelly Chiqueto;Eduardo Ferreira
    • The korean journal of orthodontics
    • /
    • v.53 no.2
    • /
    • pp.106-115
    • /
    • 2023
  • Objective: To evaluate the null hypothesis that there is no difference in a set of clinical predictors of potentially impacted canines between low-risk patients with and without displaced canines. Methods: The normal canine position group consisted of 30 patients with 60 normally erupting canines ranked in sector I (age, 9.30 ± 0.94 years). The displaced canine group comprised 30 patients with 41 potentially impacted canines ranked in sectors II to IV (age, 9.46 ± 0.78 years). Maxillary lateral incisor crown angulation, inclination, rotation, width, height, and shape, as well as palatal depth, arch length, width, and perimeter composed a set of clinical predictors, which were evaluated on digital dental casts. Statistical analyses consisted of group comparisons and variable correlations (p < 0.05). Results: There was a significant association between sex and mesially displaced canines. Unilateral canine displacement was more prevalent than bilateral displacement. The crown of the maxillary lateral incisors was significantly angulated more mesially and rotated mesiolabially in low-risk patients with displaced canines, who also had a shallower palate and shorter anterior dental arch length. Lateral incisor crown angulation and rotation, as well as palatal depth and arch length, were significantly correlated with the canine displacement severity. Conclusions: The null hypothesis was rejected. Maxillary lateral incisor angulation inconsistent with the "ugly duckling" stage as well as a shallow palate and short arch length are clinical predictors that can significantly contribute to the early screening of ectopic canines in low-risk patients.

The Instability Behavior of Shallow Sinusoidal Arches(2) : Classification of Dynamic Buckling under Step Pressure (얕은 정현형 아치의 불안정 거동에 관한 연구(2) : 스텝하중에서의 동적좌굴 특성)

  • 김승덕;박지윤;권택진
    • Journal of the Computational Structural Engineering Institute of Korea
    • /
    • v.12 no.3
    • /
    • pp.417-426
    • /
    • 1999
  • The some papers which deal with the dynamic instability for shell-like structures under the step load have been published, but there are few papers which treat the essential phenomenon of the dynamic buckling using the phase plane for investigating occurrence of chaos. In nonlinear dynamics, examining the characteristics of attractor on the phase plane and investigating the dynamic buckling process are very important thing for understanding why unstable phenomena are sensitively originated by various initial conditions. In this study, the direct and the indirect snap-buckling of shallow arches considering geometrical nonlinearity are investigated numerically and compared with the static critical load.

  • PDF

Self-propulsion Test and Analysis of Amphibious Armored Wheeled Vehicle with Propulsion System of POD Type Waterjet (전투 차량용 포드형 물 분사 추진장치의 모형시험 및 해석)

  • Byun, Tae-Young;Kim, Moon-Chan;Chun, Ho-Hwan;Kim, Jong-Hyun
    • Journal of the Society of Naval Architects of Korea
    • /
    • v.42 no.3
    • /
    • pp.197-204
    • /
    • 2005
  • A waterjet propulsion system has many advantages compared with a conventional screw propeller especially for amphibious armored wheeled vehicles because of a good maneuverability at low speed, good operation ability at shallow water, high thrust at low speed to aid maneuverability and exit from water, etc. The POD type waterjet is adequate for the present wheeled vehicle because the weight is lighter and L/B is longer than the conventional armored amphibious vehicle. Resistance and self-propulsion tests with a 1/3.5-scale model are conducted at PNU towing tank. Based on these measurements, the performance is analyzed according to ITTC 96 standard analysis method and also according to the conventional propulsive factor analysis method. Based on these two methods, the full-scale effective and delivered powers of amphibious armored wheeled vehicle are estimated. This paper emphasizes the analysis method of model test of the waterjet propulsion system for a amphibious armored wheeled vehicle and the model test technique together with the comparison of the two analysis methods.

Development of Nonlinear Dynamic Program for Buckling Analysis of Plane Circular Arches (평면 원호아치의 좌굴해석을 위한 동적 비선형해석 프로그램의 개발)

  • 허택녕;오순택
    • Computational Structural Engineering
    • /
    • v.7 no.1
    • /
    • pp.69-81
    • /
    • 1994
  • This paper summarizes a dynamic analysis of the shallow circular arches under dynamic loading, considering the geometric nonlinearity. The major emphasis is placed on the development of computer program, which is utilized for the analysis of the nonlinear dynamic behavior and for the evaluation of the critical buckling loads of the shallow circular arches. Geometric nonlinearity is modeled using Lagrangian description of the motion and a finite element analysis procedure is used to solve the dynamic equation of motion. A circular arch subject to normal step load is analyzed and the results are compared with those from other researches to verify the developed program. The critical buckling loads of arches are estimated using the non-dimensional time, load and shape parameters and the results are also compared with those from the linear analysis. It is found that geometric nonlinearity plays and important role in the analysis of shallow arches and the probability of buckling failure is getting higher as arches become shallower.

  • PDF

Shape Design Sensitivity Analysis and Optimization of Axisymmetric Shell Structures (축대칭 쉘구조물의 형상 설계민감도 해석 및 최적설계)

  • 김인용;곽병만
    • Proceedings of the Computational Structural Engineering Institute Conference
    • /
    • 1993.10a
    • /
    • pp.98-105
    • /
    • 1993
  • A method for shape design sensitivity analysis for axisymmetric shells of general shapes is developed. The basic approach is to divide the structures into many segments. For each of the segments, the formula for a shallow arch or shell can be applied and the results assembled. To interconnect those segments, the existing sensitivity formula, obtained for a variation only in the direction perpendicular to the plane on which the structure is mapped, has been extended to include a variation normal to the middle surface. The method follows the adjoint variable approach based on the material derivative concept as established in the literature. Numerical examples are taken to illustrate the method and the applicability to practical design problems.

  • PDF

Geometrically Non-Linear Analysis for Shallow Arch using the 3-Dimensional Curved Beam

  • Lee, Dae-Hee;Eum, Se-Yoon
    • Proceedings of the Korean Nuclear Society Conference
    • /
    • 1996.05d
    • /
    • pp.259-266
    • /
    • 1996
  • This paper presents a geometrically non-linear formulation for the general curved beam element based on assumed strain fields and Timoshenko's beam theory. This general curved beam element is formulated from constant strain fields. And this element, designed in a local curvilinear coordinate system, is transformed into a global cartesian system in order to analyze effectively the general curved beam structures located arbitrarly in space. Numerical examples are presented to show the accuracy and efficiency of the present formulation. The results obtained from the present formulation are compared with those available in the literature and analysis by ANSYS.

  • PDF

Suggestion of a Design Method for UAM (강관 다단 그라우팅 공법(UAM)의 설계법 제안)

  • 박이근;임종철
    • Journal of the Korean Geotechnical Society
    • /
    • v.20 no.3
    • /
    • pp.97-106
    • /
    • 2004
  • In case of tunnel construction with a shallow soil cover in cohesionless soils or highly weathered rocks, reinforcement measures are required for a tunnel stability during the tunnel construction. Recent developments show that the use of Umbrella Arch Method(UAM) as tunnel reinforcement and water cut-off in domestic projects has increased. Unfortunately, guidelines for the design and construction of UAM have not been established, only empirical designs and applications in tunnel construction have been performed so far. In this study, behaviour of the steel pipes installed on the tunnel roof was analyzed through the monitoring of bending and axial stresses of the pipes with the advance of the tunnel face. The monitoring results were used in the establishment of the loading mechanism around the pipe. This paper suggests, the guidelines used in the determination of the total length, overlapping length and lateral spacing of the reinforcing pipes obtained from the established loading mechanism.

Numerical analysis for semi cut and cover tunnelling method (반개착식 터널 공법에 관한 수치 해석적 연구)

  • Roh, Byoung-Kuk;Park, Jong-Kwan;Baek, Seung-Kyu
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.15 no.2
    • /
    • pp.113-122
    • /
    • 2013
  • Recently there has been increased interest for the portal and shallow tunnel for an eco-friendly tunneling method. Semi cut & cover tunnel excavation techniques applied to concrete slab and construction and a growing number of cases, but there is no load combinations and arch concrete cross section for the applicable standards. Therefore, in this study, ground conditions and tunnel overburden thickness, thickness of backfill, overburden surface slope angle changes to a variety of conditions in order to propose standards for the semi cut & cover method was performed numerical analysis. Regression analysis method to the analysis of the results of numerical analysis, and linear regression equations derived to classify and organize a rational, economical, and safe semi cut & cover tunneling method based proposed.

A thermoelastic microactuator with planar latch-up operation (Latch-up 특성을 갖는 평면형의 열구동 마이크로 액츄에이터)

  • 이종현;권호남;전진철;이선규;이명래;장원익;최창억;김윤태
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2001.04a
    • /
    • pp.865-868
    • /
    • 2001
  • We designed and fabricated a planner-type thermoelastic microactuator with a latch-up operation for optical switching. Latch-up actuation is prerequisite to implement an optical switch with low power consumption and high reliability. The proposed microactuator consists of four cantilever-shaped thermal actuators, four displacement linkages, two shallow arch-shaped leaf springs, a mobile shuttle mass with a micromirror, and four elastic boundaries. The structural layer of the planar microactuator is phosphorous-doped 12$\mu\textrm{m}$-thick polysilicon, and the sacrificial layer is LTO(Low Temperature Oxide) of 3$\mu\textrm{m}$thickness. The displacement of actuator is as large as 3$\mu\textrm{m}$when the length of actuation bar is 100$\mu\textrm{m}$in length at 5V input voltage. The proposed microactuators have advantages of easy assembly with other optical component by way of fiber alignment in the substrate plane, and its fabrication process features simplicity while retaining batch-fabrication economy.

  • PDF