• 제목/요약/키워드: shaking test

검색결과 540건 처리시간 0.022초

1/3축소 3층 삼환까뮤 P.C 모델의 진동대 실험 (Shaking Table Test of 1/3-Scale 3-Story Sam-Hwan Camus Precast Concrete Model)

  • 이한선
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 1992년도 가을 학술발표회 논문집
    • /
    • pp.140-154
    • /
    • 1992
  • The objective of the research stated here was aimed at providing the information needed to establish the Korean Seismic Design Code Recommendations and Guides for precast concrete (P.C) large panel apartment buildings. This was accomplished by investigation and analysis of the response of P.C large panel structures subjected to shaking table excitation simulating earthquake ground motion. one of the test specimens used was 1/3-scaled 3-story box P.C model provided by Sam-Hwan Camus Corporation. The 4m $\times$4m shaking table was used to simulate the earthquake ground motion. the employed input accelerogram was the one recorded as Taft N21E component and the peak ground acceleration(PGA) was scaled depending on the desired level of seismic severity and the time according to dynamic similitude rule. Based on results obtained from shaking table test of this P.C model, the following conclusions were drawn . (1) As far as test specimen is concerned, the seismic safety factors turns out to be 7~8. (2)P.C model has damping ratio of about8% which is twice larger than in-situ R.C. structure. And (3)this model has global displacement ductility ratio of 2~3 through the energy dissipation by opening and sliding of joints.

  • PDF

진동대 실험을 통한 적층고무받침의 내진성능 평가 (Estimation of Aseismatic Performance of Laminated Rubber Bearing Through Shaking Table Tests)

  • 박성규
    • 한국철도학회논문집
    • /
    • 제13권4호
    • /
    • pp.440-446
    • /
    • 2010
  • 본 논문은 적층고무받침을 이용하여 지진으로부터 교량의 손상피해를 줄이기 위한 연구이다. 적층고무 받침은 지진 발생시 변위를 증가시키고, 주기를 길게하여 하중을 전환시킨다. 적층고무받침과 같은 면진장치에 몇 가지 지진파를 가진하여 진동대 실험을 하였다. 이 실험에서는 가속도계와 하중계, 변위계를 설치하여 상판의 가속도 및 전단력 등을 측정하였다. 더구나 적층고무받침을 설치한 경우와 지진격리장치를 설치하지 않은 경우로 구분하여 진동대 실험하여 그 성능을 비교 평가하였다. 실험결과 상판의 가속도 및 전단력은 적층고무받침을 사용할 경우 응답이 감소하였다.

Simulation of the damping effect of a high-rise CRST frame structure

  • Lu, Xilin;Zhang, Hongmei;Meng, Chunguang
    • Computers and Concrete
    • /
    • 제9권4호
    • /
    • pp.245-255
    • /
    • 2012
  • The damping effect of a Concrete-filled Rectangular Steel Tube (CRST) frame structure is studied in this paper. Viscous dampers are employed to insure the function of the building especially subjected to earthquakes, for some of the main vertical elements of the building are not continuous. The shaking table test of a 1:15 scale model was conducted under different earthquake excitations to recognize the seismic behavior of this building. And the vibration damping effect was also investigated by the shaking table test and the simulation analysis. The nonlinear time-history analysis of the shaking table test model was carried out by the finite element analysis program CANNY. The simulation model was constructed in accordance with the tested one and was analyzed under the same loading condition and the simulation effect was then validated by the tested results. Further more, the simulation analysis of the prototype structure was carried out by the same procedure. Both the simulated and tested results indicate that there are no obvious weak stories on the damping equipped structure, and the dampers can provide the probability of an irregular CRST frame structure to meet the requirements of the design code on energy dissipation and deformation limitation.

건물-지반 시스템에 관한 진동대실험 (2) : 성층지반위의 구조물 (Shaking table test on soil-structure interaction system (2) : Superstructure with foundation on layered soil)

  • Lee Sung-Kyung;Masato Motosaka;Min Kyung-Won
    • 한국전산구조공학회:학술대회논문집
    • /
    • 한국전산구조공학회 2005년도 춘계 학술발표회 논문집
    • /
    • pp.529-537
    • /
    • 2005
  • This paper proposes the shaking table testing method, without any soil specimen only using building model as an experimental part, considering dynamic soil-structure interaction based on the substructure method. The two-layered soil is assumed as a soil model of the entire soil-structure interaction syhstem(SSI) in this paper. Differently from the constant soil stiffness, the frequency-dependent dynamic soil stiffness is approximated for the case of both acceleration and velocity feedback, respectively. The interaction force is observed from measuring the accelerations at superstructure. Using the soil filters corresponding to the approximated dynamic soil stiffness, the shaking table drives the acceleration or velocity, which the needed motion to give the building specimen the SSI effects. Experimental results show the applicability the proposed methodologies to the shaking table test considering dynamic soil-structure interaction.

  • PDF

Numerical simulation of shaking table tests on 3D reinforced concrete structures

  • Bayhan, Beyhan
    • Structural Engineering and Mechanics
    • /
    • 제48권2호
    • /
    • pp.151-171
    • /
    • 2013
  • The current paper presents the numerical blind prediction of nonlinear seismic response of two full-scale, three dimensional, one-story reinforced concrete structures subjected to bidirectional earthquake simulations on shaking table. Simulations were carried out at the laboratories of LNEC (Laboratorio Nacional de Engenharia Civil) in Lisbon, Portugal. The study was motivated by participation in the blind prediction contest of shaking table tests, organized by the challenge committee of the 15th World Conference on Earthquake Engineering. The test specimens, geometrically identical, designed for low and high ductility levels, were subjected to subsequent earthquake motions of increasing intensity. Three dimensional nonlinear analytical models were implemented and subjected to the input base motions. Reasonably accurate reproduction of the measured displacement response was obtained through appropriate modeling. The goodness of fit between analytical and measured results depended on the details of the analytical models.

Shaking table experiment on a steel storage tank with multiple friction pendulum bearings

  • Zhang, Ruifu;Weng, Dagen;Ge, Qingzi
    • Structural Engineering and Mechanics
    • /
    • 제52권5호
    • /
    • pp.875-887
    • /
    • 2014
  • The aim of the shaking table experiment is to verify the isolation effect of a storage liquid tank with multiple friction pendulum bearings. A 1:20 scale model of a real storage liquid tank that is widely used in the petroleum industry was examined by the shaking table test to compare its anchored base and isolated base. The seismic response of the tank was assessed by employing the time history input. The base acceleration, wave height and tank wall stress were used to evaluate the isolation effect. Finally, the influences of the bearing performance that characterizes the isolated tank, such as the friction force and residual displacement, were discussed.

내진실험 연구를 위한 다지점 가진 지동대의 활용 (Applications of Seismic Test using Multi-platform Shaking Table System)

  • 최형석;김남식;정진환
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2013년도 추계학술대회 논문집
    • /
    • pp.126-131
    • /
    • 2013
  • As the testing instrument for seismic research, the multi-platform shaking table system of SESTEC in the Pusan National University was introduced to suggest the multi-support shaking table testing methods and also to investigate its ability and applicability. 2 spans single-pylon cable-stayed bridge model, 3 spans girder bridge model and nuclear piping system model are presented and the acceleration and displacement table feedbacks of the each tests are compared to verify the simultaneous excitation ability in time domain and frequency domain.

  • PDF

비선형 해석프로그램을 이용한 RC교각의 진동대 시험 분석 (The analysis of RC bridge piers on shaking table test by using Nonlinear program)

  • 양동욱;박용권;이연훈;정영수;이대형
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2009년도 춘계 학술대회 제21권1호
    • /
    • pp.67-68
    • /
    • 2009
  • 본 연구는 기존의 실험 방법과 다른 근단층 지반 운동하에서의 진동대 시험을 통해 심부구속 철근비에 따른 내진성능 평가를 비교 분석하였다. 또한 비선형 해석프로그램 SARCF(Seismic Analysis of Reinforced Concrete Frames)로 교각의 손상에 따른 고유진동수의 변화를 해석을 통한 FFT 값과 시험에 의한 FFT 값을 비교 분석하여 진동대 시험에 대한 평가를 하였다.

  • PDF

가진입력의 크기에 따른 동조액체기둥감쇠기의 비선형 특성 (Nonlinear Characteristic of a Tuned Liquid Column Damper under Various Excitation Amplitudes)

  • 이성경;이혜리;민경원
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2009년도 추계학술대회 논문집
    • /
    • pp.842-849
    • /
    • 2009
  • The objective of this study is to investigate design parameters of a tuned liquid column damper(TLCD), which is affected by various excitation amplitudes, through shaking table test. Design parameters of a TLCD are examined based on the equivalent tuned mass damper(TMD) model of a TLCD, in which the nonlinear damping of a TLCD is transposed to equivalent viscous damping. Shaking table test is carried out for a TLCD specimen subjected to harmonic waves with various amplitudes. Transfer functions are ratios of liquid displacement of TLCD and control force produced by a TLCD, respectively, with respect to the acceleration excited by a shaking table. They are derived based on the equivalent TMD model of a TLCD. Then, the variation of design parameters according to the excitation amplitude is examined by comparing analytical transfer functions with experimental ones. Finally, the dissipation energy due to the damping of a TLCD, which is experimentally observed from the shaking table test, is examined according to the excitation amplitude. Comparisons between test results and analytical transfer functions showed that natural frequencies of TLCD and the ratio of the liquid mass in a horizontal column to the total liquid mass does not depend on the excitation amplitude, while the damping ratio of a TLCD increases with larger excitation amplitudes.

  • PDF

가진입력의 크기에 따른 동조액체기둥감쇠기의 비선형 특성 (Nonlinear Characteristic of a Tuned Liquid Column Damper under Various Excitation Amplitude)

  • 이성경;이혜리;민경원
    • 한국소음진동공학회논문집
    • /
    • 제19권11호
    • /
    • pp.1167-1176
    • /
    • 2009
  • The objective of this study is to investigate design parameters of a tuned liquid column damper(TLCD), which is affected by various excitation amplitude, through shaking table test. Design parameters of a TLCD are examined based on the equivalent tuned mass damper(TMD) model of a TLCD, in which the nonlinear damping of a TLCD is transposed to equivalent viscous damping. Shaking table test is carried out for a TLCD specimen subjected to harmonic waves with various amplitude. Transfer functions are ratios of liquid displacement of TLCD and control force produced by a TLCD, respectively, with respect to the acceleration excited by a shaking table. They are derived based on the equivalent TMD model of a TLCD. Then, the variation of design parameters according to the excitation amplitude is examined by comparing analytical transfer functions with experimental ones. Finally, the dissipation energy due to the damping of a TLCD, which is experimentally observed from the shaking table test, is examined according to the excitation amplitude. Comparisons between test results and analytical transfer functions showed that natural frequencies of TLCD and the ratio of the liquid mass in a horizontal column to the total liquid mass do not depend on the excitation amplitude, while the damping ratio of a TLCD increases with larger excitation amplitude.