• Title/Summary/Keyword: sewerage

Search Result 251, Processing Time 0.033 seconds

Effects of exposure intensity of sodium hydroxide on PVDF membrane performance (수산화나트륨의 노출 강도가 PVDF 분리막 성능에 미치는 영향)

  • Lee, Yong-Soo;Kang, Ha-Young;Kim, Woo-Ha;Lee, Chang-Kyu;Kim, Jong-Oh
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.32 no.5
    • /
    • pp.453-460
    • /
    • 2018
  • The impact of sodium hydroxide, which is one of chemicals of clean in place (CIP) for removing membrane fouling, on the PVDF membrane is reviewed with respect to physical/chemical structural change, the permeability affected therefrom. Based on the cleaning concentration applied in membrane water treatment facilities, 10% of accumulated defluorination was confirmed up to 166g.hr/L which reflects the exposure time. However, membrane resistance was confirmed to be reduced by about 10%. Through FT-IR and EDS analysis, reduction of F and change of are confirmed as factors that affect the permeability of membrane. Membrane resistance, which affects permeability, is affected by loss of additives for hydrophilicity, rather than defluorination of PVDF material. Therefore, in order to check membrane degradation degree, an accelerated test by NaOH was carried out, loss of additives was confirmed, and then PVDF inherent characteristic was observed.

Real-time Water Quality Prediction for Evaluation of Influent Characteristics in a Full-scale Sewerage Treatment Plant (하수처리장 유입수의 특성평가를 위한 실시간 수질예측)

  • Kim, Youn-Kwon;Chae, Soo-Kwon;Han, In-Sun;Kim, Ju-Hwan
    • Journal of Environmental Impact Assessment
    • /
    • v.19 no.6
    • /
    • pp.617-623
    • /
    • 2010
  • It is the most important subject to figure out characteristics of the wastewater inflows of sewerage treatment plant(STP) when situation models are applied to operation of the biological processes and in the automatic control based on ICA(Instrument, Control and Automation). For the purposes, real-time influent monitoring method has been applied by using on-line monitoring equipments for the process optimization in conventional STP. Since, the influent of STP is consist of complex components such as, COD, BOD, TN, $NH_4$-N, $NO_3$-N, TP and $PO_4$-P. MRA2(Microbial Respiration Analyzer 2), which is capable of real-time analyzing of wastewater characteristics is used to overcome the limitations and defects of conventional online monitoring equipments in this study. Rapidity, accuracy and stability of developed MRA2 are evaluated and compared with the results from on-line monitoring equipments for seven months after installation in Full-scale STP.

Effect of Pre-NH3 Stripping on the Advanced Sewerage Treatment by BNR (BNR에 의한 하수의 고도처리에 미치는 NH3 스트리핑 전처리의 영향)

  • Seo, Jeong-Beom;An, Kwang-Ho
    • Journal of Korean Society on Water Environment
    • /
    • v.22 no.5
    • /
    • pp.846-850
    • /
    • 2006
  • The biological nutrient removal from domestic wastewater with low C/N ratio is difficult. Therefore, this study was performed to increase influent C/N ratio by ammonia stripping without required carbon source and for improving treatment efficiencies of sewerage by the combination process of ammonia stripping and BNR (StripBNR). The results of this study were summarized as follows. BOD removal efficiencies of BNR and StripBNR were 95.3% and 93.2%, respectively. T-N and T-P removal efficiencies of BNR were 53.3% and 40.8%, respectively. T-N and T-P removal efficiencies of StripBNR were 72.8% and 62.9%, respectively. Concentrations of $NH_3-N$, $NO_2-N$ and $NO_3-N$ at BNR effluent were 0.03 mg/L, 0.08 mg/L and 9.12 mg/L, respectively. On the other hands, concentrations of $NH_3-N$, $NO_2-N$ and $NO_3-N$ at StripBNR effluent were 5.79 mg/L, 0.01 mg/L and 0.14 mg/L, respectively. Consequently, influent C/N ratio of BNR process was increased by ammonia stripping. Removal efficiency of T-N and T-P was improved about 20% by the process of StripBNR.

A Novel Marker for the Species-Specific Detection and Quantitation of Vibrio cholerae by Targeting an Outer Membrane Lipoprotein lolB Gene

  • Cho, Min Seok;Ahn, Tae-Young;Joh, Kiseong;Paik, Soon-Young;Kwon, Oh-Sang;Jheong, Won-Hwa;Joung, Yochan;Park, Dong Suk
    • Journal of Microbiology and Biotechnology
    • /
    • v.23 no.4
    • /
    • pp.555-559
    • /
    • 2013
  • Vibrio cholerae O1 and O139 are the major serotypes associated with illness, and some V. cholera non-O1 and non-O139 isolates produce cholera toxin. The present study describes a quantitative polymerase chain reaction (qPCR) assay for the species-specific detection and quantitation of V. cholera using a primer pair based on an outer membrane lipoprotein lolB gene for the amplification of a 195 bp DNA fragment. The qPCR primer set for the accurate diagnosis of V. cholera was developed from publically available genome sequences. This quantitative PCR-based method will potentially simplify and facilitate the diagnosis of this pathogen and guide disease management.

Current status of Jeju special self-governing province's water infrastructure and direction for improvement (제주특별자치도 물인프라 현황 및 개선방향)

  • Kim, Jinkeun
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.35 no.6
    • /
    • pp.497-505
    • /
    • 2021
  • This paper investigates the current status of Jeju special self-governing province (JSSGP)'s water infrastructure and recommends directions for improvement. JSSGP relies on groundwater for most of its water resources. Recently, water usage has been steadily increasing due to the increase of residents and tourists while the quality of groundwater has been steadily worsening. Deterioration in water quality of groundwater can be seen through the increase in concentration of nitrate nitrogen and microorganisms. To overcome such problems, water consumption must be reduced by water demand management in all fields including residential and agricultural water use. The quality of water resources should be preserved through the management of pollutants. For efficient management of water resources, great efforts should be made to reduce the leakage rates in household and agricultural water, which is currently at the highest level in the country. Furthermore, diversification of water intake sources other than groundwater is needed, especially for agricultural water supply. For water and sewerage facilities, compliance with drinking water quality standards and discharge water quality standards must be achieved through the optimization of operation management. This process requires recruiting professionals, improving existing workers' expertise, and improving facilities.

Biocontrol of Red Pepper Using Mixed Culture of Antagonistic Bacterium and Phosphate Solubilizing Yeast (항진균 세균과 난용성 인산염 가용화 효모의 혼합 배양액을 이용한 고추 병해의 생물학적 방제)

  • Lee, Gun Woong;Min, Byung-Dae;Park, Sujeong;Jheong, Weonhwa;Go, Eun Byeul;Lee, Kui-Jae;Chae, Jong-Chan
    • Korean Journal of Microbiology
    • /
    • v.49 no.4
    • /
    • pp.398-402
    • /
    • 2013
  • This study was to investigate beneficial effects of microbial mixture on red pepper which was capable of promoting plant growth by solubilizing insoluble phosphate as well as protecting plants from pathogenic attack. Saccharomyces sp. L13 was isolated for phosphate solubilizing activity on aluminium phosphate, tricalcium phosphate, calcium hydrophosphate, and magnesium hydrophosphate. On the other hand, Bacillus sp. L32 was isolated for antagonistic activity against Phytophthora capsisi and Colletotrichum gloeosporioides, causing Phytophthora blight and Anthracnose disease in pepper, respectively. The strain L32 exhibited antagonistic activities both under dual culture assays and detached leaves assays. The each strain under the condition of mixed cultivation exhibited the same growth rates as one under pure cultivation. In greenhouse study, the mixed culture showed the both effect of plant growth promotion and reduction of disease symptom development against P. capsisi and C. gloeosporioides providing a potential as effective microbial agent for plant husbandry.

Evaluation on Applicability of the Real-time Prediction Model for Influent Characteristics in Full-scale Sewerage Treatment Plant (하수처리장 유입수 성상 실시간 예측모델 및 활용성 평가)

  • Kim, Youn-Kwon;Kim, Ji-Yeon;Han, In-Sun;Kim, Ju-Hwan;Chae, Soo-Kwon
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2010.05a
    • /
    • pp.1706-1709
    • /
    • 2010
  • Sewerage Treatment Plants(STPs) are complexes systems in which a range of physical, chemical and biological processes occur. Since Activated Sludge Model(ASM) No.1 was published, a number of new mathematical models for simulating biological processes have been developed. However, these models have disadvantages in cost and simplicity due to the laboriousness and tediousness of their procedures. One of the major difficulties of these mathematical model based tools is that the field-operators mostly don't have the time or the computer-science skills to handle there models, so it mainly remains on experts or special engineers. In order to solve these situations and help the field-operators, the $KM^2BM$(K-water & More-M Mass Balance Model) based on the dynamic-mass balance model was developed. This paper presents $KM^2BM$ as a simulation tools for STPs design and optimization. This model considers the most important microbial behavioral processes taking place in a STPs to maximize potential applicability without increasing neither model parameter estimation nor wastewater characterization efforts.

  • PDF

Development of Information Management System by use of PDA for Wide-area Sewerage Line Construction (광역 하수관거 건설공사의 PDA 기반 공사관리 시스템의 개발)

  • Baek, Yeong-In;Kim, Bo-Hyun
    • 한국IT서비스학회:학술대회논문집
    • /
    • 2008.11a
    • /
    • pp.179-182
    • /
    • 2008
  • 국가 경제규모의 성장과 더불어 하수관거 공사의 규모도, 영세업체들에 의해 소규모 지역별로 시공되던 것에서 벗어나 최근에는 효율적 공사관리와 소요품질의 확보를 위하여 광역화되는 추세에 있다. 광역화의 규모는 2-3개 지자체와 산하의 40-50여개의 마을이 포함될 정도에 이르고 있다. 이러한 하수관거 공사의 규모 확대에 따른 변화에 대응하기 위하여는 적기, 적소에서의 제반 자원의 효율적 활용이 무엇보다 중요한 것으로 분석되었으며 이러한 문제점의 해결방안으로서 IT 기술을 활용한 공사관리시스템을 개발 사용하였다.

  • PDF

Concrete Sewerage and Counterplan of Bacteriostasis (하수도시설 콘크리트와 방균대책)

  • 길배수;김규용;성길모;남재현
    • Magazine of the Korea Concrete Institute
    • /
    • v.14 no.3
    • /
    • pp.64-70
    • /
    • 2002
  • 도시 주민생활에 없어서는 안될 주요한 사회간접자본시설로서 하수도, 하수도처리시설 등의 콘크리트 구조물에 대한 부식열화는 현재 세계 각국에서 급속히 진행되고 있다. 콘크리트 구조물이 반영구적이라는 것으로 인식되어 있으나, 실제로는 사용수명이 급속히 단축되어, 특히 콘크리트가 처해있는 환경 중에 황화수소(H$_2$S) 등의 황산화합물이 다량으로 존재하고 있는 환경에서는 하수관 콘크리트의 부식에 의해 도로가 함몰되는 사례도 보도되는 등 시민생활에 큰 위험성을 동반하는 가능성을 배제할 수 없다.(중략)

TTA 시험$\cdot$인증 서비스 - 소프트웨어 분야 -

  • 김혜경
    • TTA Journal
    • /
    • s.87
    • /
    • pp.162-168
    • /
    • 2003
  • TTA(한국정보통신기술 협회)는 2003년 4월 7일 품질 인증제품으로 연희정보통신㈜의''상·하수도 범용/UFCom v 1.0'', ㈜뉴테크웨이브의 ''VirusChaser v 5.0''등 2개의 제품에 대하여 Good Software 마크를 발급하였다. 그리고 2003년 4월 30일에 ㈜웨어밸리의''Orange for ORACLE v 2.2'', ㈜테크다임의''Techdigm Office v 2.0'', ㈜엔지스 테크널러지의''G-Solution Waterworks/Sewerage v 1.0'', 삼성에스디에스㈜의''uniCITY Standard v 1.0'', ''uniCITY Enterprise v 1.0''등 5개의 제품에 대하여 Good Software 마크를 발급하였다. 본 고에서는 상기의 인증 획득한 제품에 대하여 소개하고자 한다.

  • PDF