• Title/Summary/Keyword: setting time of concrete

Search Result 413, Processing Time 0.031 seconds

Reduction of Hydration Heat in Division-Placed Mass Concrete Considering the Difference of Setting Time in Super Retarding Agents (초지연제의 응결시간차에 따라 분할타설된 매스 콘크리트의 수화열 저감)

  • Gi, Suck;Pei, Zheng-Lie;Hwang, Yin-Seong;Yoon, Chi-Whan;Kim, Gi-Cheol;Han, Cheon-Goo
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2002.10a
    • /
    • pp.805-808
    • /
    • 2002
  • This study is designed to reduction of hydration heat of 4 layer division-placed mass concrete considering the difference of setting time of super retarding agent. According to the results, peak temperature of plain concrete by hydration heat show $63^{\circ}C$ around the age of 1 days. Hydration heat is lowest in the bottom layer, and highest in the middle of 3rd layer from the bottom. Hydration heat of mock up structure, which is division-placed at the same interval of 1 and 2 days by setting time difference of super retarding agent, is highest in the bottom layer because after peak temperature of 4th layer, hydration reaction progresses in order of 3rd, 2nd and 1st layer. But in mock up structure which is division-placed at the various interval. peak temperature by hydration heat is reduced by about $13^{\circ}C$, compared with plain concrete because after first peak hydration heat of 4th layer (plain concrete), hydration reaction progresses after the drop of hydration heat in order of 3rd, 2nd and 1st layer.

  • PDF

A Study on the Properties of the Repair materials of Concrete Structure (노후화된 콘크리트 구조물 보수재료의 기초물성에 대한 연구)

  • 이창수;김성수;곽도연;이규동
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 1998.10b
    • /
    • pp.867-870
    • /
    • 1998
  • The reinforced concrete structures have been deteriorated for various causes since it serviced for the long time. If we have to service concrete structure long time, we must repair it using appropriate methods and materials. But the data which evaluate the repair material has not been sufficient. So, the aim of this research is to estimate properties of repair materials and to acquire the data which apply to the concrete structures in field. To accomplish this objective, we have made experiment on compressive strength, bond strength, the coefficient of thermal expansion and setting time. Generally, compressive strength and bond strength are favorable but some products are unfavorable under wet curing. Setting time was faster than ordinary portland cement mortar except one material.

  • PDF

Execution of Mass Concrete for Mat Foundation Using Setting Time Difference with Super Retarding Agent for Reducing Hydration Heat (초지연제의 응결시간차 공법을 이용한 기초 매트 콘크리트의 수화열 저감 시공)

  • Jeon Chung Keun;Yoon Chi Whan;Song Seung Heon;Shin Dong An;Oh Seon Gyo;Han Cheon Goo
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2004.05a
    • /
    • pp.144-147
    • /
    • 2004
  • In this paper, field application of mass concreting using super retarding agent(SRA) are discussed based on setting. time difference with SRA in big discount market in Chongju. Mechanical and physical properties of .concrete are investigated. Temperature history of concrete is also measured. Slump and air content meet the requirement of target value. Compressive strength of concrete exceeded the nominal strength with 24MPa. Compressive strength of SRA concrete is higher than that of plain concrete by about $3\~4\%$. For temperature history, peak temperature of concrete at middle section at top concrete layer reached $49.6^{\circ}C$ within 24hours, and at bottom concrete layer, $54.6^{\circ}C$ within 42hours. Based on the naked eye's observation, no crack was found at mass concrete.

  • PDF

Analysis of Influence Factors of Setting Time Estimation System for AI-Based Concrete Finishing Automation System (AI 기반 콘크리트 마감 자동화 시스템용 응결추정계의 영향인자 분석)

  • Han, Soo-Hwan;Hu, Yun-Yao;Kim, Su-Ho;Lim, Gun-Su;Kim, Jong;Han, Min-Cheol
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2022.11a
    • /
    • pp.177-178
    • /
    • 2022
  • As part of the study on the development of the setting time estimation system, this study attempted to confirm the change in hardness values for each influencing factor variable and secure its reliability. According to the research results of this paper, the hardness value of the setting time estimation system tended to gradually decrease in the case of the hardness value of the closing time by curing temperature, and the hardness value increased in the concrete state compared to mortar. Therefore, further research on influencing factors will be conducted in consideration of material and statistical factors in the future.

  • PDF

Mock-up Test of Setting Estimation System For AI-based Concrete Finishing Automation System (AI 기반 콘크리트 마감 자동화 시스템용 응결추정계의 Mock-up Test)

  • Han, Soo-Hwan;Lim, Gun-Su;Han, Jun-Hui;Kim, Jong;Han, Min-Cheol;Han, Cheon-Goo
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2022.11a
    • /
    • pp.129-130
    • /
    • 2022
  • This study is conducted to identify improvements in the setting time estimation system through the Mock-up test of the finishing automation system and the setting estimation system. As a result of the study, it is necessary to adjust the spring strength of the setting time estimator and the diameter and length of the estimation needle so that the value of the hardness can be measured from 15HD to around 40HD.

  • PDF

A Study on high Quality of Antiwashout Underwater Concrete (수중불분리성콘크리트의 고품질화 연구)

  • 문한영;김성수;전중규;송용규
    • Journal of the Korea Concrete Institute
    • /
    • v.12 no.5
    • /
    • pp.111-120
    • /
    • 2000
  • In case of constructing concrete structure under water, generally concrete mixed with antiwashout admixture, high range water reducer, or AE-water reducing agent etc has been manufactured to ensure the quality of antiwashout underwater concrete because of being difficulty in ascertaining construction situation by the naked eye. The properties of high quality antiwashout underwater concrete that were aimed at affluent fluidity, workability and the compressive strength of 450 kgf/$\textrm{cm}^2$ at 28 ages using two types of blended cements are following as;(1) Setting time of antiwashout underwater concretes using blended cements was more greatly delayed than that of control concrete, however, was satisfied with criteria value of "Quality standard specification of antiwashout admixture for concrete".(2) As a test results of slump flow, efflux time and box elevation of head, it was found that workability of high quality antiwashout underwater concrete was improved. (3) Heat evolution amount of OPC was 1.5 times as high as that of two types of bended cements in 72 hours. (4) Suspended solids of antiwashout underwater concrete using blended cements was more than that of control concrete, also compressive strength of high quality antiwashout underwater concrete was very low in early age, but was better than that of control concrete as to increasing ages.

Fundamental Properties of Mortar Using Rapid-Setting Cement (초속경시멘트를 혼입한 모르타르의 기초물성평가)

  • Kim, Seong-Soo;Jung, Ho-Seop;Park, Kwang-Pil;Koh, Joon-Ho;Jeon, Chan-Ki;Jeon, Joong-Kyu
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2006.05b
    • /
    • pp.589-592
    • /
    • 2006
  • The growth in concrete structure repair has prompted major efforts to develop high early strength concrete. So, we were examined fundamental properties of cement mortar using the ordinary portland cement with rapid-setting cement. The experiments were carried out to investigate the characteristics of rapid-setting cement according to the blended ratio. The containing ratio of rapid-setting cement were changed five steps (20, 30, 50, 70, 100%) and then the flow value, setting time, compressive and bond strength test of cement mortar with RSC were investigated in this study.

  • PDF

Comparison of watertightness and durability of mortar with waterproof admixture for concrete (천연무기광물계 구체방수재를 사용한 모르타르의 수밀성과 내구성비교)

  • Kim, Jae-Young;Shin, Jin-Yong;Chae, Eun-Jin;Suh, Jeong-Kwon
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2006.05b
    • /
    • pp.65-68
    • /
    • 2006
  • In this study, comparison of setting time, compressive strength, watertightness and durability of between reference mortar with mortar using waterproof admixtures based on natural inorganic minerals. Test results shows that waterproof admixtures does not change setting time of mortar, but strongly improve compressive strength, permeability, absorption and durability of mortar. Especially early strength of mortar increased about 40% of reference.

  • PDF

Properties and Prediction Model for Ultra High Performance Fiber Reinforced Concrete (UHPFRC): (I) Evaluation of Setting and Shrinkage Characteristics and Tensile Behavior (초고성능 섬유보강 콘크리트(UHPFRC)의 재료 특성 및 예측모델: (I) 응결 및 수축 특성과 인장거동 평가)

  • Yoo, Doo-Yeol;Park, Jung-Jun;Kim, Sung-Wook;Yoon, Young-Soo
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.32 no.5A
    • /
    • pp.307-315
    • /
    • 2012
  • Recently, ultra high performance fiber reinforced concrete (UHPFRC) having over 180 MPa compressive strength and 10 MPa tensile strength has been developed in Korea. However, UHPFRC represents different material properties with normal concrete (NC) and conventional high performance concrete (HPC) such as a high early age autogenous shrinkage and a rapid dry on the surface, because it has a low water-binder ratio and high fineness admixtures without coarse aggregate. In this study, therefore, to propose suitable experimental methods and regulations, and to evaluate mechanical properties at a very early age for UHPFRC, setting, shrinkage and tensile tests were performed. From the setting test results, paraffin oil was an appropriate material to prevent drying effect on the surface, because if paraffin oil is applied on the surface, it can efficiently prevent the drying effect and does not disturb or catalyze the hydration of cement. From the ring-test results, it was defined that the shrinkage stress is generated at the time when the graph tendency of temperature and strain of inner steel ring is changed. By comparing with setting test result, the shrinkage stress was firstly occurred as the penetration resistance of 1.5 MPa was obtained, and it was about 0.6 and 2.1 hour faster than those of initial and final sets. So, the starting time of autogenous shrinkage measurement (time-zero) of UHPFRC was determined when the penetration resistance of 1.5 MPa was obtained. Finally, the tensile strength and elastic modulus of UHPFRC were measured from near initial setting time by using a very early age tensile test apparatus, and the prediction models for tensile strength and elastic modulus were proposed.

Flowing and Setting Properties of High Flowing$\cdot$High Strength Concrete using Blast-Furnace Slag according to the Chemical Agent (고로슬래그 미분말을 사용한 고유동고$\cdot$강도 콘크리트의 혼화제에 따른 유동 및 응결 특성)

  • Kim, Yong-Ro;Shim, Jae-Hyung;Kang, Suk-Pyo;Kim, Sang-Yun;Baik, Chul;Kim, Moo-Han
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2000.10b
    • /
    • pp.1242-1247
    • /
    • 2000
  • Results from a study on the effect of the chemical agent on the flowing and setting properties of high flowing.high strength concrete using blast-furnace slag are presented in this paper. The flowing and setting properties of concrete are investigated by slump, slump-flow, flowing velocity, L-flow, velocity of V-funnel, L-spatial passability and setting time. In addition, kinds of chemical agent were composed of naphthalene type, of naphthalene and melamine and melamine type. The results indicate that dispersive capacity can be increased by naphthalene composition. Also, it shows that viscosity and early strength can be increased by melamine composition.

  • PDF