• Title/Summary/Keyword: serial interface

Search Result 278, Processing Time 0.216 seconds

A Study on Designing of LYNX Datalink (해상작전헬기용 데이터링크 설계 연구)

  • Lee, Young-Joong;Park, Joo-Rae;Lyu, Si-Chan
    • Journal of the Korea Institute of Military Science and Technology
    • /
    • v.9 no.4
    • /
    • pp.39-49
    • /
    • 2006
  • LYNX ESM has not only ESM function but Datalink function. The LYNX boarded equipment Interface and Channel coding is needed for LYNX Datalink to support the mother ship with tactical data included threat radar analysis data of LYNX ESM, navigation data, Radar and Sonar of LYNX. The interface of loaded equipments are various protocol like as ARINC419/429, RS232, Synchro, Sync Serial. The Channel coding of Convolution-Scrambler-Interleaver-Bit Stuffing is applied for recovering the transmission data mixed with propagation errors in sea environment.

An Implementation of Integrated Information and Communication Network of Oceanographic Research Vessels for Effective Ocean Investments (효율적 해양탐사를 위한 해양조사선의 종합정보 통신망 구현)

  • Park, Jong-Won;Choi, Young-Cheol;Kang, Jun-Sun;Lim, Yong-Kon;Kim, Sea-Moon
    • Proceedings of the Korea Committee for Ocean Resources and Engineering Conference
    • /
    • 2003.05a
    • /
    • pp.330-335
    • /
    • 2003
  • This paper deals with the network interface of research and observation instruments in the oceanographic research vessel with an establishment of related database for measured information. The system is implemented to integrated communication network system which allows to effective survey by using real time observation and GUI(Graphic User Interface). The system also consists of the LAN systems and serial interface to link chemical, physical, biological and environmental relations. And, other network service and vessel data service for data communication between vessel and earth station such as INMARSAT-B, WWW service, BBS, E-Mail etc., are needed for integrated communication network system.

  • PDF

Development of UFC/DC Data Communication method for XKO-1 using RS-422 Bus (RS422 버스를 이용한 저속통제기 UFC/DC 데이터 통신 기법 개발)

  • 양승열;김영택
    • Journal of the Korea Institute of Military Science and Technology
    • /
    • v.5 no.2
    • /
    • pp.123-131
    • /
    • 2002
  • ASC(Avionics System Computer) was developed to control weapon delivery and navigation sensors, and to perform man-machine interface with pilots for XKO-1 aircraft. The data communications between ASC and UFC(Up Front Controller), DC(Data Concentrator) were implemented by RS422 serial data bus. Also, SCIL(Standard Computer Interface Library) was designed to facilitate control and management of the computer hardware resources and is embedded in the ASC. These structures have a merit of noise immunity and a reduction of wire harness for signal lines, and enable OFP(Operational Flight Program) programmers to use the SCIL easily without knowing hardware details. Manufactured system was on installed on XKO-1, and peformed for BIT(Built In Test) and interface test with UFC and DC. The test results show that it meets the system requirements.

Wearable Personal Network Based on Fabric Serial Bus Using Electrically Conductive Yarn

  • Lee, Hyung-Sun;Park, Choong-Bum;Noh, Kyoung-Ju;SunWoo, John;Choi, Hoon;Cho, Il-Yeon
    • ETRI Journal
    • /
    • v.32 no.5
    • /
    • pp.713-721
    • /
    • 2010
  • E-textile technology has earned a great deal of interest in many fields; however, existing wearable network protocols are not optimized for use with conductive yarn. In this paper, some of the basic properties of conductive textiles and requirements on wearable personal area networks (PANs) are reviewed. Then, we present a wearable personal network (WPN), which is a four-layered wearable PAN using bus topology. We have designed the WPN to be a lightweight protocol to work with a variety of microcontrollers. The profile layer is provided to make the application development process easy. The data link layer exchanges frames in a master-slave manner in either the reliable or best-effort mode. The lower part of the data link layer and the physical layer of WPN are made of a fabric serial-bus interface which is capable of measuring bus signal properties and adapting to medium variation. After a formal verification of operation and performances of WPN, we implemented WPN communication modules (WCMs) on small flexible printed circuit boards. In order to demonstrate the behavior of our WPN on a textile, we designed a WPN tutorial shirt prototype using implemented WCMs and conductive yarn.

EPICS Based Vacuum Chamber Temperature Control System for PAL Storage Ring (가속기 저장링 진공 챔버 온도측정용 제어시스템 개발 및 EPICS 적용)

  • Yoon, J.C.;Choi, J.Y.;Kang, H.S.
    • Proceedings of the KIEE Conference
    • /
    • 2005.07d
    • /
    • pp.2652-2654
    • /
    • 2005
  • A vacuum chamber temperature control system of Pohang Accelerator Laboratory (PAL) storage ring is a subsystem upgraded PAL control system, which is based upon Experimental Physics and Industrial Control System (EPICS) [1]. There are two control components, data acquisition system (SA120 data logger), development control system IOC (Input/Output Controller) at the storage ring of PAL. There are 240 vacuum chamber at the storage ring. It was a very important problem to solve how to monitor such a large number of vacuum chamber temperature distributed around the ring. The IOC connect MODBUS/JBUS field network to asynchronous serial ports for communication with serial device. It can simultaneously control up to 4 data acquisition systems. Upon receiving a command from a IOC running under Windows2k through the network, the IOC communicate through the slave serial interface ports to SA120. We added some software components on the top of EPICS toolkit. The design of the vacuum control system is discussed. This paper describes the development vacuum chamber temperature control system and how the design of this system.

  • PDF

Analyzing the Impact of Supply Noise on Jitter in GBPS Serial Links on a Merged I/O-Core Power Delivery Network

  • Tan, Fern-Nee;Lee, Sheng Chyan
    • Journal of the Microelectronics and Packaging Society
    • /
    • v.20 no.4
    • /
    • pp.69-74
    • /
    • 2013
  • In this paper, the impact of integrating large number of I/O (Input-Output) and Core power Delivery Network (PDN) on a 6 layers Flip-Chip Ball Grid Array (FCBGA) package is investigated. The impact of core induced supply noise on high-speed I/O interfaces, and high-speed I/O interface's supply noise coupling to adjacent high-speed I/O interfaces' jitter impact are studied. Concurrent stress validation software is used to induce SSO noise on each individual I/O interfaces; and at the same time; periodic noise is introduced from Core PDN into the I/O PDN domain. In order to have the maximum coupling impact, a prototype package is designed to merge the I/O and Core PDN as one while impact on jitter on each I/O interfaces are investigated. In order to understand the impact of the Core to I/O and I/O to I/O noise, the on-die noise measurements were measured and results were compared with the original PDN where each I/O and Core PDN are standalone and isolated are used as a benchmark.

Performance Evaluation and Analysis of NVMe SSD (Non-volatile Memory Express 인터페이스 기반 저장장치의 성능 평가 및 분석)

  • Son, Yongseok;Yeom, Heon Young;Han, Hyuck
    • KIISE Transactions on Computing Practices
    • /
    • v.23 no.7
    • /
    • pp.428-433
    • /
    • 2017
  • Recently, the demand for high performance non-volatile memory storage devices that can replace existing hard disks has been increasing in environments requiring high performance computing such as data-centers and social network services. The performance of such non-volatile memory can greatly depend on the interface between the host and the storage device. With the evolution of storage interfaces, the non-volatile memory express (NVMe) interface has emerged, which can replace serial attached SCSI and serial ATA (SAS/SATA) interfaces based on existing hard disks. The NVMe interface has a higher level of scalability and provides lower latency than traditional interfaces. In this paper, an evaluation and analysis are conducted of the performance of NVMe storage devices through various workloads. We also compare and evaluate the cost efficiency of NVMe SSD and SATA SSD.

Design of Image Recognition Module for Face and Iris Area based on Pixel with Eye Blinking (눈 깜박임 화소 값 기반의 안면과 홍채영역 영상인식용 모듈설계)

  • Kang, Mingoo
    • Journal of Internet Computing and Services
    • /
    • v.18 no.1
    • /
    • pp.21-26
    • /
    • 2017
  • In this paper, an USB-OTG (Uiversal Serial Bus On-the-go) interface module was designed with the iris information for personal identification. The image recognition algorithm which was searching face and iris areas, was proposed with pixel differences from eye blinking after several facial images were captured and then detected without any activities like as pressing the button of smart phone. The region of pupil and iris could be fast involved with the proper iris area segmentation from the pixel value calculation of frame difference among the images which were detected with two adjacent open-eye and close-eye pictures. This proposed iris recognition could be fast processed with the proper grid size of the eye region, and designed with the frame difference between the adjacent images from the USB-OTG interface with this camera module with the restrict of searching area in face and iris location. As a result, the detection time of iris location can be reduced, and this module can be expected with eliminating the standby time of eye-open.

Serial Tissue Expansion at the Same Site in Pediatric Patients: Is the Subsequent Expansion Faster?

  • Lee, Moon Ki;Park, Seong Oh;Choi, Tae Hyun
    • Archives of Plastic Surgery
    • /
    • v.44 no.6
    • /
    • pp.523-529
    • /
    • 2017
  • Background Serial tissue expansion is performed to remove giant congenital melanocytic nevi. However, there have been no studies comparing the expansion rate between the subsequent and preceding expansions. In this study, we analyzed the rate of expansion in accordance with the number of surgeries, expander location, expander size, and sex. Methods A retrospective analysis was performed in pediatric patients who underwent tissue expansion for giant congenital melanocytic nevi. We tested four factors that may influence the expansion rate: The number of surgeries, expander location, expander size, and sex. The rate of expansion was calculated by dividing the 'inflation amount' by the 'expander size'. Results The expansion rate, compared with the first-time group, was 1.25 times higher in the second-or-more group (P=0.04) and 1.84 times higher in the third-or-more group (P<0.01). The expansion rate was higher at the trunk than at other sites (P<0.01). There was a tendency of lower expansion rate for larger expanders (P=0.03). Sex did not affect the expansion rate. Conclusions There was a positive correlation between the number of surgeries and the expansion rate, a positive correlation between the expander location and the expansion rate, and a negative correlation between the expander size and the expansion rate.

An Implementation of Spirometry System Based Differential Pressure Method (차동 압력 방식을 이용한 호흡측정 시스템 구현)

  • 김요한;신창민;김영길
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2002.11a
    • /
    • pp.440-447
    • /
    • 2002
  • This paper considerated about exact flow volume calculation method from factors having an influence on measurement and introduced in anesthesia ventilator realized spirometry system. System used differential pressure sensing method with factors, that is temperature, pressure, gas density, humidity and mucus etc. System optimized for low power system for mobile system. System composed analog interface part, signal processing part, display part. Analog interface part have differential pressure flow sensor and defferential pressure sensor. Signal processing part have AVR processor for low power system display part use serial port (RS232, SPT). so it display at pc monitor or send to anesthesia ventilator. System is stable by linearizing 2th characteristics of flow-differential pressure, auto correction of sensor. Noise reduced by algorithm with analog filter and digital processing. Small, light, low power system is good at mobile system and applied to patient in emergency or mobile. and, System is useful at anesthesia ventilator by using flow sensor.

  • PDF