• Title/Summary/Keyword: sensitivity changes

Search Result 1,287, Processing Time 0.028 seconds

Estimating Ozone Sensitivity Coefficients to NOx and VOC Emissions Using BFM and HDDM for A 2007 June Episode (HDDM과 BFM을 이용한 NOx와 VOC 배출량에 대한 오존민감도계수 산정 및 결과 비교: 2007년 6월 수도권 사례)

  • Kim, Soon-Tae
    • Journal of Environmental Science International
    • /
    • v.20 no.11
    • /
    • pp.1465-1481
    • /
    • 2011
  • The accuracy of ozone sensitivity coefficients estimated with HDDM (High-order Decoupled Direct Method) can vary depending on the $NO_x$ (Nitrogen Oxides) and VOC (Volatile Organic Compound) conditions. In order to evaluate the applicability of HDDM over the Seoul Metropolitan Area (SMA) during a high ozone episode in 2007 June, we compare BFM (Brute Force Method) and HDDM in terms of the $1^{st}$-order ozone sensitivity coefficient to explain ozone change in response to changes in NOx and VOC emissions, and the $2^{nd}$-order ozone sensitivity coefficient to represent nonlinear response of ozone to the emission changes. BFM and HDDM estimate comparable ozone sensitivity coefficients, exhibiting similar spatial and temporal variations over the SMAduring the episode. NME (Normalized Mean Error) between BFM and HDDM for the episode average $1^{st}$- and $2^{nd}$-order ozone sensitivity coefficients to NOx and VOC emissions are less than 3% and 9%, respectively. For the daily comparison, NME for the $1^{st}$- and $2^{nd}$-order ozone sensitivity coefficients are less than 4% ($R^2$ > 0.96) and 15% ($R^2$ > 0.90), respectively. Under the emission conditions used in this study, two methods show negative episode average $1^{st}$-order ozone sensitivity coefficient to $NO_x$ emissions over the core SMA. The $2^{nd}$-order ozone sensitivity coefficient to $NO_x$ emissions leads ozone to respond muchnonlinear to the reduction in $NO_x$ emissions over Seoul. Nonlinear ozone response to reduction in VOC emissions is mitigated due to the $2^{nd}$-order ozone sensitivity coefficient which is much smaller than the $1^{st}$-order ozone sensitivity coefficient to the emissions in the magnitude.

Sensitivity Analysis of Stochastic User Equilibrium in a Multi-Modal Network (다수단 확률적 사용자 균형의 민감도 분석)

  • Kim, Byeong-Gwan;Im, Yong-Taek
    • Journal of Korean Society of Transportation
    • /
    • v.28 no.5
    • /
    • pp.117-129
    • /
    • 2010
  • This study presents a sensitivity analysis method for stochastic user equilibrium of multi-modal network flows. We consider a multi-modal network consisting of a road network for passenger cars physically separated from a transit network for public transport. We first establish a sensitivity analysis method with respect to arbitrary link parameters and perform a sensitivity analysis with respect to link capacity and transit line frequency as practical link parameters. Next, We establish a sensitivity analysis method and perform the sensitivity analysis with respect to modal split by passenger car and public transit. As with the elasticity of economics, these results can be important information for analyzing changes in travel behavior due to the changes in operation and policy of transportation facilities, as well as for analyzing the effects of these operational changes and policies. These results also can be utilized as a tool to constitute a multi-modal network design problem by using cooperative game theory.

DEVELOPMENT OF CALCULATION METHOD OF SENSITIVITIES FOR LIGHT WATER REACTORS

  • Takeda, Toshikazu;Foad, Basma
    • Nuclear Engineering and Technology
    • /
    • v.45 no.6
    • /
    • pp.753-758
    • /
    • 2013
  • A new method of calculating sensitivity coefficients of core characteristics relative to infinite-dilution cross sections has been developed. Conventional sensitivity coefficients are evaluated for the changes of effective cross sections which are dependent on individual models of core and cell. Therefore a correction has been derived to the conventional sensitivity coefficients based on the perturbation theory. The accuracy of the present method has been verified by comparing numerical results of sensitivity coefficients with a reference Monte-Carlo method.

Identifiability of Ludwik's law parameters depending on the sample geometry via inverse identification procedure

  • Zaplatic, Andrija;Tomicevic, Zvonimir;Cakmak, Damjan;Hild, Francois
    • Coupled systems mechanics
    • /
    • v.11 no.2
    • /
    • pp.133-149
    • /
    • 2022
  • The accurate prediction of elastoplasticity under prescribed workloads is essential in the optimization of engineering structures. Mechanical experiments are carried out with the goal of obtaining reliable sets of material parameters for a chosen constitutive law via inverse identification. In this work, two sample geometries made of high strength steel plates were evaluated to determine the optimal configuration for the identification of Ludwik's nonlinear isotropic hardening law. Finite element model updating(FEMU) was used to calibrate the material parameters. FEMU computes the parameter changes based on the Hessian matrix, and the sensitivity fields that report changes of computed fields with respect to material parameter changes. A sensitivity analysis was performed to determine the influence of the sample geometry on parameter identifiability. It was concluded that the sample with thinned gauge region with a large curvature radius provided more reliable material parameters.

Design Sensitivity Studies for Statistical Energy Analysis Modeling of Construction Vehicle Cab (통계적 에너지 해석 모델을 이용한 건설 장비 차실 설계에 관한 연구)

  • 채장범
    • Journal of KSNVE
    • /
    • v.8 no.4
    • /
    • pp.609-615
    • /
    • 1998
  • In recent years there has been an increasing emphasis on shortening design cycles for bringing products to market. This requires the development of computer aided engineering tools which allow analysts to quickly evaluate the effect of design changes on noise, vibration, and harshness. Statistical Energy Analysis (SEA) modeling is a valuable tool for predicting noise and vibration as SEA models are inherently simpler and more robust than deterministic models. SEA modeling can be combined with design sensitivity analysis(DSA) to identify design changes which give the largest performance benefit. This paper describes SEA modeling of an equipment cab. SEA predictions are compared to test data, showing good agreement. The use of design sensitivity analysis in improving cab design is then demonstrated.

  • PDF

The Determination of Temperature and Humidity Sensitivity Coefficients of Torque Transducers using Seasonal Climatic Changes of Ambient Conditions in the Laboratory (계절에 따른 실험실 환경변화를 이용한 토크측정기의 온도 및 습도 감도계수 결정)

  • Derebew, Mulugeta;Kim, Min Seok;Park, Yon Kyu;Lee, Ho Young
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.32 no.2
    • /
    • pp.185-190
    • /
    • 2015
  • This paper presents a new method to determine sensitivity coefficients of temperature and humidity of torque transducers by using a natural and seasonal variation of ambient conditions at the laboratory. We had measured the sensitivities of the torque transducers over almost one year using the KRISS 2 kN m torque standard machine. The sensitivity data acquired at various ambient conditions were processed using our measurement model to extract the sensitivity coefficients of temperature and humidity simultaneously with high precision. A comparison with a previous method using an environmental control chamber was carried out to test the feasibility of using our new method. Two results agreed within the uncertainty. We revealed that the torque measuring errors could be 8 times higher than the measurement and calibration capability of KRISS torque standard machine if the sensitivity changes due to the temperature and humidity are not properly corrected during a calibration.

Changes in sensitivity across visual field induced by exogenous attention (외인성 주의 유도에 의한 시야의 시각 민감도 변화)

  • Jeong, Sang-Cheol;Hyeon, Ju-Seok;Jeong, Chan-Seop
    • Korean Journal of Cognitive Science
    • /
    • v.8 no.4
    • /
    • pp.63-75
    • /
    • 1997
  • Changes in visual sensitivity were investigated as a function of distance from the locus of attention. While a subject was fixating at a point on a frontal plane, one of the two attention inducing points placed horizontally and symmetrically 4。 apart from it was blinked and a target immediately followed at a location around the blinking dot. The subject's task was to decide and report whether the target was present or abscent. The rate of detection was the highest at the immediate vicinity of the locus of attention and decreased gradually as a function of the distance from it. Results of the experiments support the gradient model of attention-induced changes in visual sensitivity.

  • PDF

Changes of Contrast Sensitivity with Decreasing Luminance in Photopic Conditions (명소시 상태에서 휘도 감소에 따른 대비감도 변화)

  • Lee, Eun Jin;Yoon, Moon Joo;Kim, Soo-Hyun;Yang, Gye Tak;Jeong, Ju-Hyun;Kim, Hyun Jung;Kim, Hyun Il;Choi, Eun Jung
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.17 no.4
    • /
    • pp.411-417
    • /
    • 2012
  • Purpose: To investigate changes of contrast sensitivity with decreasing luminance in photopic conditions. Methods: Contrast sensitivities for 63 university students were investigated at 5 different luminance levels using FACT chart. Results: All contrast sensitivities measured were in the normal range. The peak of contrast sensitivity function was observed to move from 6 to 3 cpd between 40 and $10cd/m^2$. From an intersection point of two hypothetical lines related with contrast sensitivity for 6 and 3 cpd, we could evaluated that the peak moved from 6 to 3 cpd at about $25cd/m^2$. When luminance decreases from 120 to $10cd/m^2$, contrast sensitivity loss at 6 cpd was most, while contrast sensitivity at 1.5 cpd changed little. We could evaluate that at luminance of more than $25cd/m^2$ evaluated approximately, contrast sensitivity was high in the following order of spatial frequency: 18< 12<1.5<3<6 cpd, while at luminance of less than about $25cd/m^2$ as follows: 18<12<1.5<6<3 cpd. Contrast sensitivity losses with decreasing luminance were also evaluated using the decrements and decrement rates of contrast sensitivity. The decrement of contrast sensitivity was the greatest at 6 cpd, while the decrement rate was the greatest at 8 cpd. Conclusions: We propose that evaluation methods used in this research may be available as another methods to evaluate the changes of contrast sensitivity.

Effect of red ginseng on visual function and vision-related quality of life in patients with glaucoma

  • Lee, Kwanghyun;Yang, Heon;Kim, Joo Yeon;Choi, Wungrak;Seong, Gong Je;Kim, Chan Yun;Lee, Jun Mo;Bae, Hyoung Won
    • Journal of Ginseng Research
    • /
    • v.45 no.6
    • /
    • pp.676-682
    • /
    • 2021
  • Background: Red ginseng has been found to improve ocular perfusion and dry eye syndrome in glaucomatous eyes; however, its effects on visual function and vision-related quality of life have not been investigated. This study sought to evaluate the effects of red ginseng on visual function and vision-related quality of life in glaucoma patients using contrast sensitivity and a questionnaire. Methods: Participants were randomly assigned to two groups in this prospective, randomized, double-blind study: in one group, red ginseng was taken first, followed by a placebo, and in the other, placebo was taken first, followed by red ginseng. We measured and compared changes in contrast sensitivity and vision-related quality of life between the two groups. Contrast sensitivity was measured using OPTEC® 6500P, and vision-related quality of life was evaluated using the 25-item National Eye Institute Visual Function Questionnaire. One-way and two-way repeated measure analyses of variance were used for the comparison. Relationships between respective changes in dry eye syndrome and contrast sensitivity were also analyzed. Results: Daytime contrast sensitivity and ocular pain improved after the administration of red ginseng. Nighttime contrast sensitivity was improved in early or moderate glaucoma. Improved contrast sensitivity was not associated with improvement in dry eye syndrome. Conclusion: Red ginseng could improve contrast sensitivity and ocular pain in patients with glaucoma. The mechanism underlying improvement in contrast sensitivity appears to be associated with enhanced retinal perfusion or retinal ganglion cell function, but not dry eye syndrome.

Parametric Sensitivity Analyses of Linear System relative to the Characteristic Ratios of Coefficient (I) : A General Case (계수의 특성비에 대한 선형계의 파라미터적 감도해석(I): 일반적인 경우)

  • 김영철;김근식
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.10 no.3
    • /
    • pp.205-215
    • /
    • 2004
  • The characteristic ratio assignment (CRA) method〔1〕 is new polynomial approach which allows to directly address the transient responses such as overshoot and speed of response time in time domain specifications. The method is based on the relationships between time response and characteristic ratios($\alpha_i$ ) and generalized time constant (T), which are defined in terms of coefficients of characteristic polynomial. However, even though the CRA can apply to developing a linear controller that meets good transient responses, there are still some fundamental questions to be explored. For the purpose of this, we have analyzed several sensitivities of a linear system with respect to the changes of coefficients itself and $\alpha_i$ of denominator polynomial. They are (i) the unnormalized root sensitivity : to determine how the poles change as $\alpha_i$ changes, and (ii) the function sensitivity to determine the sensitivity of step response to the change of o, and to analyze the sensitivity of frequency response as o, changes. As an other important result, it is shown that, under any fixed T and coefficient of the lowest order of s in denominator, the step response is dominantly affected merely by $\alpha_1, alpha_2 and alpha_3$ regardless of the order of denominator higher than 4. This means that the rest of the$\alpha_i$ s have little effect on the step response. These results provide some useful insight and background theory when we select $\alpha_i$ and T to compose a reference model, and in particular when we design a low order controllers such as PID controller.