• 제목/요약/키워드: sensing skin

검색결과 75건 처리시간 0.024초

Dual-Toehold-Probe-Mediated Exonuclease-III-Assisted Signal Recycles Integrated with CHA for Detection of mecA Gene Using a Personal Glucose Meter in Skin and Soft Tissue Infection

  • Jiaguang Su;Wenjun Zheng
    • Journal of Microbiology and Biotechnology
    • /
    • 제33권12호
    • /
    • pp.1692-1697
    • /
    • 2023
  • Staphylococcus aureus integrated with mecA gene, which codes for penicillin-binding protein 2a, is resistant to all penicillins and other beta-lactam antibiotics, resulting in poor treatment expectations in skin and soft tissue infections. The development of a simple, sensitive and portable biosensor for mecA gene analysis in S. aureus is urgently needed. Herein, we propose a dual-toehold-probe (sensing probe)-mediated exonuclease-III (Exo-III)-assisted signal recycling for portable detection of the mecA gene in S. aureus. When the target mecA gene is present, it hybridizes with the sensing probe, initiating Exo III-assisted dual signal recycles, which in turn release numerous "3" sequences. The released "3" sequences initiate catalytic hairpin amplification, resulting in the fixation of a sucrase-labeled H2 probe on the surface of magnetic beads (MBs). After magnet-based enrichment of an MB-H1-H2-sucrase complex and removal of a liquid supernatant containing free sucrase, the complex is then used to catalyze sucrose to glucose, which can be quantitatively detected by a personal glucose meter. With a limit of detection of 4.36 fM for mecA gene, the developed strategy exhibits high sensitivity. In addition, good selectivity and anti-interference capability were also attained with this method, making it promising for antibiotic tolerance analysis at the point-of-care.

갈륨 미세입자 탄성 복합체 기반 고민감도와 광대역폭을 갖는 가변 강성 압력센서 (Adaptive Pressure Sensor with High Sensitivity and Large Bandwidth Based on Gallium Microdroplet-elastomer Composite)

  • 이시목;변상혁;스티브박;심주용;정재웅
    • 센서학회지
    • /
    • 제31권6호
    • /
    • pp.423-427
    • /
    • 2022
  • A pressure sensor that mimics the sensing ability of human skin has emerged as high-profile technology because it shows remarkable applications in numerous fields such as robotics, human health monitoring, and artificial prosthetics. Whereas recent pressure sensors have achieved high sensitivity similar to that of human skin, they still show limited detection bandwidth. Moreover, once these e-skin are fabricated, their sensitivity and stiffness are fixed; therefore, they can be used for only limited applications. Our study proposes a new adaptive pressure sensor built with uniform gallium microdroplet-elastomer composite. Based on the phase transition of gallium microdroplets, the proposed sensor undergoes mode transformation, enabling it to have a higher sensitivity and wider detection bandwidth compared with those of human skin. In addition, we succeeded in extending a single adaptive pressure sensor to sensor arrays based on its high uniformity, reproducibility, and large-scale manufacturability. Finally, we designed an adaptive e-skin with the sensor array and demonstrated its applications on health monitoring tasks including blood pulse and body weight measurements.

Investigation of sea skin surface effects and sea surface emissivity effects based on thermal infrared camera image

  • Tamba, Sumio;Yoshimori, Kyu;Inomata, Kazuya
    • 대한원격탐사학회:학술대회논문집
    • /
    • 대한원격탐사학회 2002년도 Proceedings of International Symposium on Remote Sensing
    • /
    • pp.657-662
    • /
    • 2002
  • Sea surface temperatures (SSTs) estimated from satellite data are affected by various kinds of disturbance factors. In order to accurately estimate SSTs based on radiometric data observed by satellite, it is important to correct the effects by these disturbance factors. We obtained a huge data set of skin sea surface temperature images observed by a thermal infrared camera (TIC) in MUBEX Campaign. TIC installed on an observation vessel recorded sea surface skin temperature distribution under various weather conditions. Based on some special images observed by TIC, we estimated skin effects and effective sea surface emissivity. In this paper, we report the methods and results of these estimations.

  • PDF

Wireless Bio-Signal Sensing System Using a Circular Polarized Antenna

  • Kwon Young-Bae;Park Jung-Min;Choe Jung-Hwan;Park Seong-Ook;Ishida Osami
    • Journal of electromagnetic engineering and science
    • /
    • 제5권3호
    • /
    • pp.132-139
    • /
    • 2005
  • Wireless bio-signal sensing system, which is based on the principle of Doppler radar, can measure a respiration and heart rates with a periodic movement of skin and muscle near the heart. Though the sensing monostatic system using a circulator has been studied, this bistatic system can be improved by using a circular polarized antenna which has a high isolation between transmitter and receiver. In this paper, we measured the bio-signal without the direct contact with the person. The design of each system and experimental results are discussed.

Flexible biosensors based on field-effect transistors and multi-electrode arrays: a review

  • Kim, Ju-Hwan;Park, Je-Won;Han, Dong-Jun;Park, Dong-Wook
    • Journal of Semiconductor Engineering
    • /
    • 제1권3호
    • /
    • pp.88-98
    • /
    • 2020
  • As biosensors are widely used in the medical field, flexible devices compatible with live animals have aroused great interest. Especially, significant research has been carried out to develop implantable or skin-attachable devices for real-time bio-signal sensing. From the device point of view, various biosensor types such as field-effect transistors (FETs) and multi-electrode arrays (MEAs) have been reported as diverse sensing strategies. In particular, the flexible FETs and MEAs allow semiconductor engineering to expand its application, which had been impossible with stiff devices and materials. This review summarizes the state-of-the-art research on flexible FET and MEA biosensors focusing on their materials, structures, sensing targets, and methods.

Lactobacillus plantarum APsulloc 331261 발효 용해물의 피부 미생물 조절 효과 (Lactobacillus plantarum APsulloc 331261 Fermented Products as Potential Skin Microbial Modulation Cosmetic Ingredients)

  • 김한별;명길선;이현기;최은정;박태훈;안수선
    • 대한화장품학회지
    • /
    • 제46권1호
    • /
    • pp.23-29
    • /
    • 2020
  • 피부에는 여러 종의 미생물들이 군집을 이루며 서식하고 있고, 서로 상호작용을 하며 균형을 유지하고 있다. 하지만, 여드름, 건선 및 아토피 피부염과 같은 질병 상태에서는 피부 미생물의 균형이 깨져 건강한 피부와는 다른 미생물 군집 구성을 보인다. 피부 미생물 군집 구성의 조절은 이러한 피부 질환에 대한 잠재적인 치료 방법이 될 수 있다. Quorum sensing (QS)은 세포간 전달인자로, QS을 조절하면 유해균의 바이오필름 형성이나 효소 분비등을 억제할 수 있고, 이 역시 피부 미생물 군집 구성에 영향을 준다. 이번 연구에서는 아모레퍼시픽의 특허 성분인 유산균 발효 용해물(Lactobacillus plantarum APsulloc 331261, KCCM 11179P 이용)의 QS억제능력 및 피부 유익균과 피부 유해균의 생장에 미치는 영향을 확인하였다. 유산균 발효 용해물 10 ㎍/mL 처리시, QS에 의해 제어되는 Chromobacterium violaceum의 자주색 안료 생산을 대조군 대비 27.4% 감소시켰다. 또 피부 유익균인 Staphylococcus epidermidis의 생장을 대조군 대비 12% 증가 시켰고, 피부 유해균인 Pseudomonas aeruginosa의 생장을 38.5% 감소, 바이오필름 형성을 17.7% 감소시켰다. S. epidermidis를 같은 속(genus)에 포함되어 있는 대표적인 피부 유해균 Staphylococcus aureus와 함께 공배양 하였을 때 S. epidermidis의 생장은 대조군 대비 134% 증가시켰고, S. aureus의 생장은 13% 억제시켰다. 이러한 결과들을 종합하였을 때 L. plantarum APsulloc 331261을 이용한 발효 용해물은 피부 미생물의 균형을 조절해 줄 수 있는 화장품 원료로 유용하게 사용 될 수 있다고 사료된다.

Clinical In Vivo Bio Assay of Glucose in Human Skin by a Tattoo Film Carbon Nano Tube Sensor

  • Ly, Suw Young;Lee, Chang Hyun
    • 한국응용과학기술학회지
    • /
    • 제34권3호
    • /
    • pp.595-601
    • /
    • 2017
  • In vivo assay of glucose detection was described using a skin tattoo film electrode (STF), and the probe was made from carbon nano tube paste modification film paper. Here in the square-wave stripping anodic working range obtained of $20-100mgL^{-1}$ within an accumulation time of 0 seconds only in sea water electrolyte solutions of pH 7.0. The relative standard deviations of 50 mg glucose that were observed of 0.14 % (n=12), respectively, using optimum stripping accumulation of 30 sec, the low detection limit (S/N) was pegged at 15.8 mg/L. The developed results can be applied to the detect of in vivo skin sensing in real time. Which confirms the results are usable for in vitro or vivo diagnostic clinical analysis.

인공촉각과 피부를 위한 탄소나노튜브 기반 생체 모방형 신경 개발 (A Biomimetic Artificial Neuron Matrix System Based on Carbon Nanotubes for Tactile Sensing of e-Skin)

  • 김종민;김진호;차주영;김성용;강인필
    • 제어로봇시스템학회논문지
    • /
    • 제18권3호
    • /
    • pp.188-192
    • /
    • 2012
  • In this study, a carbon nanotube (CNT) flexible strain sensor was fabricated with CNT based epoxy and rubber composites for tactile sensing. The flexible strain sensor can be fabricated as a long fibrous sensor and it also may be able to measure large deformation and contact information on a structure. The long and flexible sensor can be considered to be a continuous sensor like a dendrite of a neuron in the human body and we named the sensor as a biomimetic artificial neuron. For the application of the neuron in biomimetic engineering, an ANMS (Artificial Neuron Matrix System) was developed by means of the array of the neurons with a signal processing system. Moreover, a strain positioning algorithm was also developed to find localized tactile information of the ANMS with Labview for the application of an artificial e-skin.

Real Time ECG Monitoring Through a Wearable Smart T-shirt

  • Mathias, Dakurah Naangmenkpeong;Kim, Sung-Il;Park, Jae-Soon;Joung, Yeun-Ho
    • Transactions on Electrical and Electronic Materials
    • /
    • 제16권1호
    • /
    • pp.16-19
    • /
    • 2015
  • A wearable sensing ECG T-shirt for ubiquitous vital signs sensing is proposed. The sensor system consists of a signal processing board and capacitive sensing electrodes which together enable measurement of an electrocardiogram (ECG) on the human chest with minimal discomfort. The capacitive sensing method was employed to prevent direct ECG measurement on the skin and also to provide maximum convenience to the user. Also, low power integrated circuits (ICs) and passive electrodes were employed in this research to reduce the power consumption of the entire system. Small flexible electrodes were placed into cotton pockets and affixed to the interior of a worn tight NIKE Pro combat T-shirt. Appropriate signal conditioning and processing were implemented to remove motion artifacts. The entire system was portable and consumed low power compared to conventional ECG devices. The ECG signal obtained from a 24 yr. old male was comparable to that of an ECG simulator.

공중파열탄용 포탄에 묻혀있는 탐지코일의 직경에 의한 유도전압 변화 (Diameter Effect of Induced Voltage in Sensing Coil Buried in Projectile for Application of Air Bursting Munition)

  • 류권상;남승훈;정재갑;손대락
    • 한국자기학회지
    • /
    • 제26권2호
    • /
    • pp.62-66
    • /
    • 2016
  • 포탄에 묻혀있는 탐지코일에서 유도되는 전압으로부터 총구를 떠나는 포탄의 초기속도를 계산하기 위하여 링 형태의 자석, 요크 및 탐지코일로 모델을 구성하였다. 자기장 해석에 의해 탐지코일의 유도전압에서 구한 마스터 곡선으로부터 포탄의 초기속도를 구할 수 있다. 탐지코일의 유도전압은 포탄에 묻혀있는 탐지코일 직경의 크기에 영향을 받는데, 직경의 크기가 증가하면 유도전압도 비례하여 증가한다. 탐지코일에서 유도되는 전압의 직경 효과를 감안한 초기속도 변화에 대한 정보를 입력하면 목표에서 포탄이 정확하게 폭발할 수 있다.