• Title/Summary/Keyword: selective detection

Search Result 580, Processing Time 0.024 seconds

Detection of Vibrio vulnificus in Fish Farm and Bactericidal Methods on this Bacteria (가두리 양식장의 Vibrio vulnificus 검출 및 제어 방법)

  • 성치남;송계민;이규호;양성렬
    • Korean Journal of Microbiology
    • /
    • v.38 no.4
    • /
    • pp.281-286
    • /
    • 2002
  • Detection of Vibrio vulnificus in fish farm and searching for the bactericidal methods on this bacteria were studied. To detect this microorganism in sea water, mud, fish and mussels, selective isolation methods and detection of vvhA gene were used from January to October,2000. V. vulnificus was detected from May when the water temperature was over $17^{\circ}C$. From June to September, higher than $19^{\circ}C$, this bacteria could be isolated from most of the samples. Freezing and refrigerating did not inhibit the growth of V. vulnificus. Citric acid did not show the bactericidal effect, but more than 500 mg/l of EDTA did. With the aid of UV and photocatalyst, $TiO_{2}$ showed bactericidal effect after 15 minute treatment. Photocatalytic system consisted of glass bead coated with $TiO_{2}$ and UV illumination showed bactericidal effect on V. vulnificus at the turnover rate of 0.2/min.

In Situ Detection and Differential Counts of Bifidobacterium spp. Using Bromocresol Green, a pH-dependent Indicator

  • Kim, Ki-Hwan;Shin, Won-Cheol;Park, Young-Seo;Yoon, Sung-Sik
    • Food Science and Biotechnology
    • /
    • v.16 no.1
    • /
    • pp.99-103
    • /
    • 2007
  • The purpose of this study was to develop a simple detection method, possibly at the species-level, that allows for large-scale screening of bifidobacteria. Human fecal samples were plated on MRS-raffinose agar containing cysteine and neomycin sulfate, serving as selective pressure for bifidobacteria, and 0.003%(w/v) bromocresol green. All of the test strains grew well on this medium at $37{\pm}1^{\circ}C$, forming white colonies surrounded by yellow halos, which presented a sharp contrast against the green background. In this disc assay, the required incubation time to develop a yellowish zone varied with the species of Bifidobacterium that was tested, allowing for differential counts and easy identification at the species-level: 10-14 hr for B. bifidum, 20-22 hr for B. catenulatum and B. infantis. and 24-25 hr for B. longum and B. breve. No apparent color was observed for B. angulatum and B. adolescentis 28 hr after inoculation. To evaluate the results of pH indicator-based identification, individual isolates were subjected to a colony-PCR experiment with genus-specific primers. The amplified products from the isolates were in good accordance with those from the reference strains at a level of 95% agreement. These results suggest that the present method could be conveniently applied to cell counts, as well as to the preliminary identification of bifidobacteria from a variety of sample types including human feces, dairy products, and commercial probiotic supplements.

Photoluminescent Graphene Oxide Microarray for Multiplex Heavy Metal Ion Analysis

  • Liu, Fei;Ha, Hyun Dong;Han, Dong Ju;Park, Min Su;Seo, Tae Seok
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2013.08a
    • /
    • pp.281.2-281.2
    • /
    • 2013
  • Since heavy metal ions included in water or food resources have critical effects on human health, highly sensitive, rapid and selective analysis for heavy metal detection has been extensively explored by means of electrochemical, optical and colorimetric methods. For example, quantum dots (QDs), such as semiconductor QDs, have received enormous attention due to extraordinary optical properties including high fluorescence intensity and its narrow emission peaks, and have been utilized for heavy metal ion detection. However, the semiconductor QDs have a drawback of serious toxicity derived from cadmium, lead and other lethal elements, thereby limiting its application in the environmental screening system. On the other hand, Graphene oxide (GO) has proven its superlative properties of biocompatibility, unique photoluminescence (PL), good quenching efficiency and facile surface modification. Recently, the size of GO was controlled to a few nanometers, enhancing its optical properties to be applied for biological or chemical sensors. Interestingly, the presence of various oxygenous functional groups of GO contributes to opening the band gap of graphene, resulting in a unique PL emission pattern, and the control of the sp2 domain in the sp3 matrix of GO can tune the PL intensity as well as the PL emission wavelength. Herein, we reported a photoluminescent GO array on which heavy metal ion-specific DNA aptamers were immobilized, and sensitive and multiplex heavy metal ion detection was performed utilizing fluorescence resonance energy transfer (FRET) between the photoluminescent monolayered GO and the captured metal ion.

  • PDF

Perception of Sex Pheromone in Moth (나방의 성페로몬 감지)

  • Park, Kye Chung
    • Korean journal of applied entomology
    • /
    • v.61 no.1
    • /
    • pp.1-14
    • /
    • 2022
  • Moths have a well-developed sex pheromone communication system. Male moths exhibit an extremely sensitive and selective sex pheromone detection system so that they can detect the sex pheromone produced by conspecific females and locate them for successful mating. Using the pheromone detection system, male moths display characteristic stereotypic behavioral responses, flying upwind to follow intermittent filamentous pheromone strands in pheromone plume. The chemical composition of female sex pheromone in moths, typically comprised of multiple compounds, is species-specific. Male moths contain specialized pheromone receptor neurons on the antennae to detect conspecific sex pheromone accurately, and distinguish it from the pheromones produced by other species. The signals from pheromone receptor neurons are integrated and induce relevant behavior from the male moths. Male moths also contain olfactory sensory neurons in pheromone sensilla, specialized for pheromone-related behavioral antagonist compounds, which can enhance discrimination between conspecific and heterospecific pheromones. Here we review reports on the sex pheromone detection system in male moths and their related responses, and suggest future research direction.

A Pyrenyl-Appended Triazole-Based Calix[4]arene as a Fluorescent Sensor for Iodide Ion

  • Kim, Jong-Seung;Park, Sun-Young;Kim, Sang-Hoon;Thuery, Pierre;Souane, Rachid;Matthews, Susan E.;Vicens, Jacques
    • Bulletin of the Korean Chemical Society
    • /
    • v.31 no.3
    • /
    • pp.624-629
    • /
    • 2010
  • The synthesis and evaluation of a novel calix[4]arene-based fluorescent chemosensor 1 for the detection of I. is described. The fluorescent changes observed upon addition of various anions show that 1 is selective for I. over other anions. Addition of I. results in ratiometric measurements with 1 : 1 complex ratio.

A Linear Beacon System Featuring an Internal Deoxyguanine Quencher Allows Highly Selective Detection of Single Base Mismatches

  • Lee, Young-Ae;Hwang, Gil-Tae
    • Bulletin of the Korean Chemical Society
    • /
    • v.31 no.7
    • /
    • pp.2011-2014
    • /
    • 2010
  • The fluorescence intensity of a single-stranded oligonucleotide containing a fluorene-labeled deoxyuridine $(U^{Fl})$ unit increases by only 1.5-fold upon formation of its perfectly matched duplex. To increase the fluorescence signal during hybridization, we positioned a quencher strand containing a deoxyguanine (dG) nucleobase, functioning as an internal quencher, opposite to the $U^{Fl}$ unit to reduce the intrinsic fluorescence upon hybridization with a probe. From an investigation of the optimal length of the quencher strand and the effect of the neighboring base sequence, we found that a short strand (five-nucleotide) containing all natural nucleotides and dG as an internal quencher was effective at reducing the intrinsic fluorescence of a linear beacon; it also exhibited high total discrimination factors for the formation of perfectly matched and single base-mismatched duplexes. Such assays that function based on clear changes in fluorescence in response to single-base nucleotide mutations would be useful tools for accelerating diagnoses related to various diseases.

Flow Control Throughput Performance Improvement of Adaptive Packet Length Allocation Scheme in Wireless Data Communication System (무선 데이타 통신 시스템에서 적응패킷길이할당방식을 이용한 흐름제어 기능 개선)

  • 정기호;박종영;금홍식;이상곤;류흥균
    • Journal of the Korean Institute of Telematics and Electronics A
    • /
    • v.32A no.2
    • /
    • pp.11-18
    • /
    • 1995
  • Error detection in ARQ(Automatic Repeat Request) protocols is very important in wireless data communication systems. The throughput efficiency of ARQ protocols can be improved by dynamically adapting the protocol packet length so that it approaches the optimum value for throuhput efficiency. In this paper, a simple and novel adaptive packet length allocation method is proposed which transmits the packets with variable length by dyanmically estimating the channel codition. The simulation results show that the average of throughput is improved by 315.4% in the stop-and-wait protocol, 41.4% in the go-back-N protocol and 155.9% in the selective repeat protocol respectively. And the throughput performances of adaptive packet length allocation method approximately approach the theoritically optimal throughput performances.

  • PDF

Selective detection of AC transport current distributions in GdBCO coated conductors using low temperature scanning Hall probe microscopy

  • Kim, Chan;Kim, Mu Young;Park, Hee Yeon;Ri, Hyeong-Ceoul
    • Progress in Superconductivity and Cryogenics
    • /
    • v.19 no.1
    • /
    • pp.26-29
    • /
    • 2017
  • We studied the distribution of the current density and its magnetic-field dependence in GdBCO coated conductors with AC bias currents using low temperature scanning Hall probe microscopy. We selectively measured magnetic field profiles from AC signal obtained by Lock-in technique and calculated current distributions by inversion calculation. In order to confirm the AC measurement results, we applied DC current corresponding to RMS value of AC current and compared distribution of AC and DC transport current. We carried out the same measurements at various external DC magnetic fields, and investigated field dependence of AC current distribution. We notice that the AC current distribution unaffected by external magnetic fields and preserved their own path on the contrary to DC current.

Design of an Intelligent Streetlight System in USN

  • Oh, Sun Jin
    • International Journal of Advanced Culture Technology
    • /
    • v.2 no.2
    • /
    • pp.1-6
    • /
    • 2014
  • In this paper, we propose an intelligent streetlight system that has a complex sensor module of temperature, humidity, luminance and motion detection and controlled by the fuzzy logic based central monitoring system in order to get flexible and precise manipulation of the streetlight system in USN environment. The proposed streetlight system provides low power consumption and high efficiency by using sensed data from the complex sensor module, which were collected, processed, and analyzed by the fuzzy logic based central monitoring system. The performance of the proposed streetlight system is to be evaluated by a simulation study in terms of power savings and safety at the fields constructed as a test-bed under several suggested scenarios. Finally, we know that the proposed intelligent streetlight system can maximize the energy savings efficiently with the fuzzy logic based central monitoring system and selective remote dimming control by connecting it to the wireless ubiquitous sensor network (USN) using a Zigbee module.

Spectrophotometric Determination of Nitrite Based on Its Reaction with p-Nitroaniline in the Presence of Diphenylamine in Micellar Media

  • Afkhami, Abbas;Masahi, Shokofeh;Bahram, Morteza
    • Bulletin of the Korean Chemical Society
    • /
    • v.25 no.7
    • /
    • pp.1009-1011
    • /
    • 2004
  • In the present work a very simple, sensitive and selective spectrophotometric method for the determination of nitrite in micellar media is described. The method is based on the color reaction of nitrite with p-nitroaniline in the presence of diphenylamine in acid media. In order to remove the extraction step, Triton X-100, a non-ionic surfactant was used as micellar media. The optimum reaction conditions such as acid concentration, reagents concentration and effect of time have been studied and the analytical characteristics of the method such as limit of detection, linear range and molar absorptivity have been obtained. The interference of some anions and cations was also tested. The method was applied to the determination of nitrite in real samples.