• Title/Summary/Keyword: selection tube

Search Result 118, Processing Time 0.026 seconds

Evaluation of Tear Film Lipid Layer Thickness Measurements Obtained Using an Ocular Surface Interferometer in Nasolacrimal Duct Obstruction Patients

  • Lee, Sang Min;Chung, Sok Joong;Lew, Helen
    • Korean Journal of Ophthalmology
    • /
    • v.32 no.6
    • /
    • pp.445-450
    • /
    • 2018
  • Purpose: To compare the tear film lipid layer thickness (LLT) between patients with incomplete nasolacrimal duct obstruction (NLDO) and normal controls and to analyze the changes in tear film LLT and blinking pattern after silicone tube intubation in NLDO patients. Methods: We reviewed the medical records of 68 eyes in 52 incomplete NLDO patients who underwent silicone tube intubation from January 2017 to July 2017. The LLT, blinking pattern, and Meibomian gland image were measured with the LipiView II ocular surface interferometer. The Meibomian gland drop-out ratio was measured using the polygon selection tool in the Image J program. Tear meniscus height, which is the other lacrimal indicator, was assessed with spectral-domain optical coherence tomography. Results: Tear meniscus height was significantly decreased after silicone tube intubation (p < 0.01). Preoperative minimum, maximum, and average LLT values were $62.4{\pm}24.0$, $86.7{\pm}17.9$, and $71.7{\pm}23.3nm$, respectively. Significant changes in the minimum, maximum, and average LLT ($74.8{\pm}23.6$, $98.8{\pm}11.0$, and $91.6{\pm}16.1nm$, respectively) were observed after silicone tube intubation (p < 0.001, p = 0.001, and p < 0.001). The partial blinking/total blinking ratio in 20 seconds and the Meibomian gland drop-out ratio showed no significant change after silicone tube intubation. Conclusions: Overall, the LLT was increased after silicone tube intubation. Silicone tube intubation may be helpful in maintaining LLT with a normalized of amount of tears.

Investigation of FIV Characteristics on a Coaxial Double-tube Structure (동심축 이중관 구조에서 유동기인진동 특성 고찰)

  • Song, Kee-Nam;Kim, Yong-Wan;Park, Sang-Chul
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.33 no.10
    • /
    • pp.1108-1118
    • /
    • 2009
  • A Very High Temperature Gas Cooled Reactor (VHTR) has been selected as a high energy heat source of the order of $950^{\circ}C$ for nuclear hydrogen generation, which can produce hydrogen from water or natural gas. A primary hot gas duct (HGD) as a coaxial double-tube type cross vessel is a key component connecting a reactor pressure vessel and an intermediate heat exchanger in the VHTR. In this study, a structural sizing methodology for the primary HGD of the VHTR is suggested in order to modulate a flow-induced vibration (FIV). And as an example, a structural sizing of the horizontal HGD with a coaxial double-tube structure was carried out using the suggested method. These activities include a decision of the geometric dimensions, a selection of the material, and an evaluation of the strength of the coaxial double-tube type cross vessel components. Also in order to compare the FIV characteristics of the proposed design cases, a fluid-structure interaction (FSI) analysis was carried out using the ADINA code.

Radiation Dose Reducing Effect during the AEC System in the Chest and Abdomen of the MDCT Scanning (흉부 및 복부에서 AEC 적용에 따른 MDCT의 선량 감소 효과)

  • Lee, Jong-Seok;Kweon, Dae-Cheol;You, Beong-Gyu
    • The Journal of the Korea Contents Association
    • /
    • v.9 no.3
    • /
    • pp.225-231
    • /
    • 2009
  • The purpose of the current study was to compare radiation dose of 64MDCT performed with automatic exposure control (AEC) with manual selection fixed tube current. We evaluated the CT scans of phantom of the chest and abdomen using the fixed tube current and AEC technique. Objective image noise shown as the standard deviation of CT value in Hounsfield units was measured on the obtained images. Compared with fixed tube current, AEC resulted in reduction of the chest and abdomen in the CTDIvol (35.2%, 5.9%) and DLP (49.3%, 3.2%). Compared with manually selected fixed tube current, AEC resulted in reduced radiation dose at MDCT study of chest and abdomen.

A Spring Back Calculation Model for the Sensitivity Analysis of Tube Design Parameters of Helical Steam Generator

  • Kim, Yong-Wan;Kim, Jong-In;Huh, Hyung;Park, Jin-Seok;Kim, Ji-Ho
    • Proceedings of the Korean Nuclear Society Conference
    • /
    • 1999.10a
    • /
    • pp.355.2-355
    • /
    • 1999
  • The spnng back phenomena occurring in the coiling process of a steam generator tube induces the dimensional inaccuracy and makes the coiling procedure difficult. In this research, an analytical model was developed to evaluate the amount of the spring back for SMART steam generator tubes. The model was developed on the basis of beam theory and elastic-perfectly plastic material property. This model was extended to consider the effect of plastic hardening and the effect of the tensile force on the spring back phenomena. Parametric studies were performed for various design variables of steam generator tubes in order to minimize the spring back in the design stage. A sensitivity analysis has shown that the low yield strength, the high elastic modulus, the small helix diameter, and the large tube diameter result in a small amount of the spring back. The amount of the spring back can be controlled by the selection of adequate design values in the basic design stage and reduced to an allowable limit by the application of the tensile force to the tube during the coiling process.rocess.

  • PDF

Temperature Prediction Method for Superheater and Reheater Tubes of Fossil Power Plant Boiler During Operation (화력발전 보일러 과열기 및 재열기 운전 중 튜브 온도예측기법)

  • Kim, Bum-Shin;Song, Gee-Wook;Yoo, Seong-Yeon
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.36 no.5
    • /
    • pp.563-569
    • /
    • 2012
  • The superheater and reheater tubes of a heavy-load fossil power plant boiler can be damaged by overheating, and therefore, the degree of overheating is assessed by measuring the oxide scale thickness inside the tube during outages. The tube temperature prediction from the oxide scale thickness measurement is necessarily accompanied by destructive tube sampling, and the result of tube temperature prediction cannot be expected to be accurate unless the selection of the overheated point is precise and the initial-operation tube temperature has been obtained. In contrast, if the tube temperature is to be predicted analytically, considerable effort (to carry out the analysis of combustion, radiation, convection heat transfer, and turbulence fluid dynamics of the gas outside the tube) is required. In addition, in the case of analytical tube temperature prediction, load changes, variations in the fuel composition, and operation mode changes are hardly considered, thus impeding the continuous monitoring of the tube temperature. This paper proposes a method for the short-term prediction of tube temperature; the method involves the use of boiler operation information and flow-network-analysis-based tube heat flux. This method can help in high-temperaturedamage monitoring when it is integrated with a practical tube-damage-assessment method such as the Larson-Miller Parameter.

Analysis of Factors Influencing Personal Media Creators' Platform Selection : Focusing on YouTube, Twitch and AfreecaTV (1인 미디어 창작자의 플랫폼 선택에 영향을 미치는 요인 연구 : 유튜브, 트위치, 아프리카TV를 중심으로)

  • Bang, Eun-Hye;Kim, Ye-Lim;Na, Hwaseong;Lee, Sang-Woo
    • The Journal of the Korea Contents Association
    • /
    • v.22 no.7
    • /
    • pp.562-582
    • /
    • 2022
  • Although personal media have become a giant industry, there is a lack of understanding of personal media creators. Therefore, this study aims to clarify factors influencing personal media creators' choice of platform. According to the analysis, there is a significant difference between the factors considered by YouTube, AfreecaTV, and Twitch creators. Moreover, the moderating effect of creators' main genre and broadcasting type were also found to be partially significant. It was found that both creators who share the motive of vividness and communication as their main genre and creators who focus on recording and broadcasting with career development motivation prefer YouTube.

The Effects of viscosity and Osmolality of Enteral Solution on Flow Rates Through Nasogastric Tubes in Vitro (경관급식 유동액의 점도와 삼투압이 체외에서 비장관 튜브를 통한 흐름속도에 미치는 영향)

  • 한경희
    • Journal of Nutrition and Health
    • /
    • v.26 no.6
    • /
    • pp.793-803
    • /
    • 1993
  • This study was designed to measure viscosity, osmolality and in vitro flow rates via nasogastric tubes for 6 types of commercially available and 9 hospital-blenderized enteral solutions and to examine the effect of viscosity and osmolaility of enteral formula on the flow rates in gravity drip administration. Each solution was infused through 18, 16, 14, 12 French sizes of silicone rubber tube. Flow rates were measured six times at $25^{\circ}C$ using formula bags and drip sets hung at a uniform height on a intravenous drip stand with tube uniformly positioned in collecting container. Viscosity ranged widely from 16.0 to 195.5 cps with mean, 64.61$\pm$64.42 for hospital-blenderized formula while mean viscosity of commercial formula was 7.60$\pm$4.84 cps. Mean osmolality of commercial formula and hospital-blenderized formula were 370$\pm$100.80, 540.33$\pm$89.37 mOsm/kg respectively. There was negative relationship between viscosity of formula and flow rates through tubes but no significant relationship between flow rates and osmolalty. Some of hospital-blenderized formula was too viscous to be infused througth tube with gravity drip administration and the recipe of formula requires to be modiifed. On the other hand, commercial formula with the low viscosity flows too rapidly with large bore size tubes. Smaller size of tube must be selected for hyperosmolar solution to decrease possible side effects associated with tube feeding. Two kinds of regression equations for flow rates obtained according to viscosity and tube sizes were also presented for the purpose of practical uses. In conclusion, this study emphasizes that viscosity of fomula, osmolality, patient's tolerance and comfort, caloric density should be considered in the selection of tubes for gravify drip administration.

  • PDF

Intention to Work as a YouTube Creator: Focusing on Generation Z's Occupational Values (유튜브 크리에이터 직업 선택 의향: Z세대 직업 가치관을 중심으로)

  • Cho, Ju-Yeon;Jang, Seong-Ho
    • The Journal of the Korea Contents Association
    • /
    • v.21 no.3
    • /
    • pp.752-760
    • /
    • 2021
  • The present study aimed to identify predictors of Youtube creator's Willingness to work as a profession. This work is notable, given its prevalence in preference as an occupation due to the development of information and communication technology. In the present work, a survey study was utilized and respondents' perception of job values, interest, self-esteem as well as willingness to work were measured. The results from a multiple regression analysis indicate that, realistic type (-), artistic type (+), corporate type (+) job value and job interest were significantly predictive of willingness to work. This study discussed implications including the need to establish career support services for YouTube creators as a profession and further for differentiated approaches based on job values or individual tendencies. The result from the current work is important, in that this study identified the willingness and influential factors of YouTube creators from a professional perspective, reflecting the recent growing interest in YouTube creators.

Assessment on Impact Factor for Dehydration of Mine Drainage Sludge Using Flocculant and Dewatering Tube(KOMIR-Tube System) (응집제 및 탈수튜브(KOMIR-Tube 시스템)를 활용한 광산배수 슬러지 탈수 영향인자 평가)

  • Misun Park;Juin Ko;Gwanin Bak;Seunghan Baek
    • Economic and Environmental Geology
    • /
    • v.57 no.2
    • /
    • pp.263-270
    • /
    • 2024
  • In this study, impact factors for dehydration with KOMIR-Tube system using flocculant and dewatering tube were evaluated for mine drainage sludges. The experiments were conducted on semi-active facility sludges with water contents above 90 % using KOMIR-Tube system. The flocculant and input amount were determined from laboratory experiment and the dewatering efficiency was verified onsite experiment. The sludge characteristics were identified by instrumental analysis such as zeta potential measurement, particle size analysis, XRD, XRF and SEM-EDS. Selection of flocculants for sludge dewatering treatment need to consider not only precipitated rate but also filterated rate. Floc size has to keep at least 0.7 mm. From on-site experiments, sludge dewatering using KOMIR-Tube system suggests to carry out April and May that is low rainfall and humidity considering to climate conditions. Also, dewatering rate depends on the crystal degree of mineral that mainly makes up sludges. Particularly, goethite of the iron hydroxides has better dewatering rate than ferrihydrite. Ferrihydrite is low degree of crystallinity and uncleared or broad shaped crystal, goethite is good crystallinity with needle shaped crystal so that the effect of flocculation and dewatering showed to depend on the crystal. In results, impact factors of dewatering for mine drainage sludges are related to flocculant, climate, crystallinity and shape of iron hydroxides.

Design of Bridge Transport System with Equal Incremental Telescopic Motion (동일신축 텔레스코픽모션을 갖는 천정이동장치 설계)

  • Yoon, Kwang-Ho;Lee, Hyo-Jik;Lee, Jong-Kwang;Park, Byung-Suk;Kim, Ki-Ho
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.34 no.2
    • /
    • pp.227-235
    • /
    • 2010
  • This paper introduces the design of a bridge transport system with a telescopic tube for positioning equipment to perform remote handling tasks in a radioactive facility. It consists of an extensible and retractable telescopic tube assembly for z-direction motion, a cabling system for management of power and signal cables, and a trolley system for transverse motion and accommodating servo drives. The working environment for the bridge transport system with the telescopic tube requires strict geometrical constraints, including a short height, short telescopic tube length when retracted, and a long stroke. These constraints were met by solving a nonlinear programming problem involving the optimal dimensions. This paper introduces a cabling system for effective management of cables with changeable lengths to accommodate telescopic motions and a selection guide for servo drives that are sufficient to drive the system.