감육형상 및 내압이 원자력 감육배관의 파단에 미치는 영향 -내압과 굽힘모멘트가 동시에 작용하는 경우- (Effect of Wall Thinned Shape and Pressure on Failure of Wall Thinned Nuclear Piping Under Combined Pressure and Bending Moment)

  • 심도준;임환;최재붕;김영진;김진원;박치용
    • 대한기계학회논문집A
    • /
    • 제27권5호
    • /
    • pp.742-749
    • /
    • 2003
  • Failure of a pipeline due to local wall thinning is getting more attention in the nuclear power plant industry. Although guidelines such as ANSI/ASME B31G and ASME Code Case N597 are still useful fer assessing the integrity of a wall thinned pipeline, there are some limitations in these guidelines. For instance, these guidelines consider only pressure loading and thus neglect bending loading. However, most Pipelines in nuclear power plants are subjected to internal pressure and bending moment due to dead-weight loads and seismic loads. Therefore, an assessment procedure for locally wall thinned pipeline subjected to combined loading is needed. In this paper, three-dimensional finite element(FE) analyses were performed to simulate full-scale pipe tests conducted for various shapes of wall thinned area under internal pressure and bending moment. Maximum moments based on true ultimate stress(${\alpha}$$\sub$u,t/) were obtained from FE results to predict the failure of the pipe. These results were compared with test results, which showed good agreement. Additional finite element analyses were performed to investigate the effect of key parameters, such as wall thinned depth, wall thinned angle and wall thinned length, on maximum moment. Also, the effect of internal pressure on maximum moment was investigated. Change of internal pressure did not show significant effect on the maximum moment.

동적 원심모형실험에 의한 사질토에 근입된 말뚝지지 기초의 응답 스펙트럼 분석 (Assessment of Response Spectrum by Dynamic Centrifuge Test for the Pile Foundation into the Sand)

  • 박용부;박종배;김상연;김동수
    • 토지주택연구
    • /
    • 제5권1호
    • /
    • pp.35-40
    • /
    • 2014
  • 현재 국내 내진설계기준에서 제시하고 있는 지반분류 방법 및 지반 증폭계수는 기반암이 주로 30m 이내에 위치하는 일반적인 국내 지반특성을 제대로 반영하지 못하고 있다. 따라서, 본 연구에서는 사질토 지반에 근입된 비정형 말뚝기초(PHC 500, 중심 간격 3D, 4D, 5D)와 상부 구조물에 대한 동적 원심모형 실험을 실시하여 자유장과 기초판의 응답 스펙트럼 결과를 비교하였다. 단주기 영역인 1초 이내 주기에서는 기초판 및 지표면 자유장의 측정 스펙트럼이 SC 및 SD 지반의 표준설계스펙트럼 가속도보다 크게 나타났다. 1.5초 이상의 장주기 영역에서는 실험에서 측정된 스펙트럼 가속도가 SC 지반의 표준설계응답스펙트럼 가속도보다 작게 나타났고 상부구조물 유무, 지반 근입 심도, 기초 및 자유장 조건에 의한 스펙트럼 가속도 차이가 거의 발생하지 않았다. 따라서, 실제 아파트에 해당하는 1.5초 이상의 장주기에서는 국내 지반조건을 고려하여 측정된 스펙트럼 가속도를 설계에 적용하면 표준설계스펙트럼을 적용할 때 보다 경제적인 설계가 가능한 것으로 나타났다.

국부 감육과 균열이 발생한 TP316 스테인리스강 배관의 파괴거동에 관한 실험적 연구 (An Experimental Study on Failure Behavior of TP316 Stainless Steel Pipe with Local Wall Thinning and Cracking)

  • 정진환;김인태;최석진;최형석;김희성
    • 한국강구조학회 논문집
    • /
    • 제24권6호
    • /
    • pp.647-657
    • /
    • 2012
  • 원자력 배관 시스템은 엄격한 설계기준에 따라 제작 되었음에도 불구하고, 장기 사용에 따라 발생하는 감육 및 균열에 의한 파손 사례가 보고되고 있다. 이에 본 연구에서는 스테인리스강 배관 시험체의 단조하중 및 반복하중 재하실험을 실시하여 국부 감육과 균열의 손상유무 및 0%, 35%, 75%의 손상정도가 배관의 파괴거동에 미치는 영향을 실험적으로 검토하였다. 본 실험에서는 실제 원자력 발전소에서 사용되고 있는 직경 3인치 TP316 스테인리스강 엘보우와 직관 배관을 대상으로 하여, 인위적으로 곡관부와 용접부에 0%, 35%, 75%의 국부적인 감육과 균열을 도입하고 20MPa의 내압을 가한 후 재하실험을 실시하였다. 그 결과, 국부 감육 및 균열의 손상정도가 파괴모드, 최대하중, 반복회수 및 에너지흡수율에 미치는 영향을 정량적으로 평가하였다. 그리고 휨 모멘트를 이용하여 ASME의 결함 허용기준을 평가하였다.

Evaluation of seismic performance of mid-rise reinforced concrete frames subjected to far-field and near-field ground motions

  • Ansari, Mokhtar;Ansari, Masoud;Safiey, Amir
    • Earthquakes and Structures
    • /
    • 제15권5호
    • /
    • pp.453-462
    • /
    • 2018
  • Damages to buildings affected by a near-fault strong ground motion are largely attributed to the vertical component of the earthquake resulting in column failures, which could lead to disproportionate building catastrophic collapse in a progressive fashion. Recently, considerable interests are awakening to study effects of earthquake vertical components on structural responses. In this study, detailed modeling and time-history analyses of a 12-story code-conforming reinforced concrete moment frame building carrying the gravity loads, and exposed to once only the horizontal component of, and second time simultaneously the horizontal and vertical components of an ensemble of far-field and near-field earthquakes are conducted. Structural responses inclusive of tension, compression and its fluctuations in columns, the ratio of shear demand to capacity in columns and peak mid-span moment demand in beams are compared with and without the presence of the vertical component of earthquake records. The influences of the existence of earthquake vertical component in both exterior and interior spans are separately studied. Thereafter, the correlation between the increase of demands induced by the vertical component of the earthquake and the ratio of a set of earthquake record characteristic parameters is investigated. It is shown that uplift initiation and the magnitude of tensile forces developed in corner columns are relatively more critical. Presence of vertical component of earthquake leads to a drop in minimum compressive force and initiation of tension in columns. The magnitude of this reduction in the most critical case is recorded on average 84% under near-fault ground motions. Besides, the presence of earthquake vertical components increases the shear capacity required in columns, which is at most 31%. In the best case, a direct correlation of 95% between the increase of the maximum compressive force and the ratio of vertical to horizontal 'effective peak acceleration (EPA)' is observed.

Nonlinear response of r.c. framed buildings retrofitted by different base-isolation systems under horizontal and vertical components of near-fault earthquakes

  • Mazza, Fabio;Mazza, Mirko;Vulcano, Alfonso
    • Earthquakes and Structures
    • /
    • 제12권1호
    • /
    • pp.135-144
    • /
    • 2017
  • Near-fault ground motions are characterized by high values of the ratio between the peak of vertical and horizontal ground accelerations, which can significantly affect the nonlinear response of a base-isolated structure. To check the effectiveness of different base-isolation systems for retrofitting a r.c. framed structure located in a near-fault area, a numerical investigation is carried out analyzing the nonlinear dynamic response of the fixed-base and isolated structures. For this purpose, a six-storey r.c. framed building is supposed to be retrofitted by insertion of an isolation system at the base for attaining performance levels imposed by current Italian code in a high-risk seismic zone. In particular, elastomeric (e.g., high-damping-laminated-rubber bearings, HDLRBs) and friction (e.g., steel-PTFE sliding bearings, SBs, or friction pendulum bearings, FPBs) isolators are considered, with reference to three cases of base isolation: HDLRBs acting alone (i.e., EBI structures); in-parallel combination of HDLRBs and SBs (i.e., EFBI structures); FPBs acting alone (i.e., FPBI structures). Different values of the stiffness ratio, defined as the ratio between the vertical and horizontal stiffnesses of the HDLRBs, sliding ratio, defined as the global sliding force divided by the maximum sliding force of the SBs, and in-plan distribution of friction coefficient for the FPs are investigated. The EBI, EFBI and FPBI base-isolation systems are designed assuming the same values of the fundamental vibration period and equivalent viscous damping ratio. The nonlinear dynamic analysis is carried out with reference to near-fault earthquakes, selected and scaled on the design hypotheses adopted for the test structures.

다주식 기초 해상교량에서 대구경 현장타설말뚝과 파일캡의 강결합에 대한 분석 (Analysis on the Rigid Connections between the Large Diameter Drilled Shaft and the Pile Cap for the Sea-Crossing Bridges with Multiple Pile Foundations)

  • 조성민;박상일
    • 한국지반공학회:학술대회논문집
    • /
    • 한국지반공학회 2008년도 춘계 학술발표회 초청강연 및 논문집
    • /
    • pp.343-358
    • /
    • 2008
  • Piles of a bridge pier are connected with a column through a pile cap(footing). Behavior of the pile foundation can be different according to the connection method between piles and the pile cap. This difference causes a change of the design method. Connection methods between pile heads and the pile cap are divided into two groups ; rigid connections and hinge connections. KHBDC(Korea Highway Bridge Design Code) has specified to use rigid connection method for the highway bridge. In the rigid connection method, maximum bending moment of a pile occurs at the pile head and this helps the pile to prevent the excessive displacement. Rigid methods are also good to improve the seismic performance. However some specifications prescribe that conservative results through investigations for both the fixed-head condition and the free-head condition should be reflected in the design. This statement may induce an over-estimated design for the bridge which have very good quality structures with casing covered drilled shafts and the PC-house contained pile cap. Because the assumption of free-head conditions (hinge connections) are unreal for the elevated pile cap system with multiple piles of the long span sea-crossing bridges. On the other hand, elastic displacement method to evaluate the pile reactions under the pile cap is not suitable for this type of bridges due to impractical assumptions. So, full modeling techniques which analyze the superstructure and the substructure simultaneously should be performed. Loads and stress state of the very large diameter drilled shaft and the pile cap for Incheon Bridge which will the longest bridge in Korea were investigated through the full modeling for rigid connection conditions.

  • PDF

감진계통 지지부가 설치된 기기의 지진해석 (Seismic Response Analysis of Support-Isolated Equipment in Primary Structure)

  • 김영상;이동근
    • 대한토목학회논문집
    • /
    • 제12권2호
    • /
    • pp.35-42
    • /
    • 1992
  • 본 논문에서는 주 구조물 내에 설치된 기기의 지지점에 감진계통을 도입함으로써 지진하중에 대한 기기의 응답감소효과를 연구하였으며, 효율적인 해석을 수행하기 위해 구조물-기기 상호작용 고려 및 축소 행렬방법을 이용한 전산프로그램(KBISAP)을 개발하였다. 지지점에 감전장치가 설치된 기기의 지진하중에 대한 응답감소 효율성을 평가하기 위해 세가지 해석모델, 즉 고정기초구조물 상의 지지점이 고정된 기기, 감진기초구조물 상의 지지점이 고정된 기기 및 고정기초구조물 상의 지지점에 감진계통이 설치된 기기를 채택한 예제해석 결과, 본 논문에서 채택한 방법이 일반적인 고정기초구조물은 물론 감진기초구조물 상에 설치된 기기의 지진하중에 대한 응답감소 보다 더 효율적임을 알 수 있었다. 따라서 본 방법은 기기의 응답감소는 물론 중요한 기기의 안전성 향상에 효과적이다.

  • PDF

주구조물 및 부구조물에 대한 감진장치의 지진응답 감소 효율성 (Effectiveness of Isolation-System on Reduction of Seismic Response of Primary and Secondary Structures)

  • 김영상;이동근
    • 대한토목학회논문집
    • /
    • 제12권4_1호
    • /
    • pp.9-21
    • /
    • 1992
  • 논문에서는 주구조물의 기초와 부구조물의 지지점에 설치된 감진장치가 구조물의 지진응답 감소에 미치는 영향을 분석하였다. 여러가지 지진하중의 특성에 따른 감진장치가 설치된 주구조물과 부구조물의 거동을 비교분석하였으며, 이때 사용된 해석모델은 고정기초 구조물에 지지점이 고정된 부구조물, 감진기초 구조물에 지지점이 고정된 부구조물, 고정기초 구조물에 지지점 감진장치가 설치된 부구조물과 같은 세가지이다. 부구조물의 응답계산에서는 주구조물과 부구조물의 상호작용을 고려하였다. 계산에 사용한 수치적분방법은 constant average acceleration 방법이며, 이 방법과 축소행렬방법을 이용한 전산프로그램(KBISAP)을 사용하였다. 또한 지진하중에 대한 구조물의 지면에 대한 상대변위를 제한시키기 위하여 여러가지 지진하중에 대한 구조물의 가속도와 변위의 상관관계를 계산하여 감진장치의 적합한 수평강성을 분석하였다.

  • PDF

비선형 응답이력해석의 영향인자에 대한 사례연구 - 1989 Loma Prieta 지진 계측기록을 중심으로 - (Case Study on Influential Factors of Nonlinear Response History Analysis - Focused on 1989 Loma Prieta Earthquake -)

  • 유계항;이진선
    • 한국지반공학회논문집
    • /
    • 제33권12호
    • /
    • pp.45-58
    • /
    • 2017
  • 최근 들어 시설물별 내진설계기준이 성능기반 내진설계로 전환됨에 따라, 신뢰성있는 비선형 응답이력해석(Response-history analysis, RHA)에 대한 요구가 높아지고 있다. 그러나, 부지응답해석 분야에 있어서는 1970년대 이후 등가선형 해석이 표준절차로 자리잡고 있음에 따라, 이를 대체하기 위해서는 비선형 응답이력해석의 신뢰성이 확보되어야 한다. 본 논문에서는 1989년 미국 Loma Prieta 지진기록을 바탕으로 다층지반에 대해서 비선형 RHA를 이용한 부지응답해석 결과의 신뢰성을 검증하였다. 이를 위하여, 비선형 RHA를 위한 비선형 지반모델의 선정방법과 3차원 해석시 요구되는 기반암 경계조건의 영향을 평가 하였다. 평가 결과, 제한된 조건하에서 가장 정확한 비선형 지반모델과 경계조건을 적용 시 비선형 RHA의 결과는 등가선형 해석결과와 유의미한 차이는 발생하지 않음을 알 수 있었다. 또한, 3차원 해석을 시행하는 경우, 전체 모델의 회전운동을 제어하기 위하여 최 하단부 흡수 경계조건을 적용해야 함을 알 수 있었다.

Determination of seismic hazard and soil response of a critical region in Turkey considering far-field and near-field earthquake effect

  • Sonmezer, Yetis Bulent;Celiker, Murat
    • Geomechanics and Engineering
    • /
    • 제20권2호
    • /
    • pp.131-146
    • /
    • 2020
  • Evaluation of earthquake impacts in settlements with a high risk of earthquake occurrence is important for the determination of site-specific dynamic soil parameters and earthquake-resistant structural planning. In this study, dynamic soil properties of Karliova (Bingol) city center, located near to the intersection point of the North Anatolian Fault Zone and the East Anatolian Fault Zone and therefore having a high earthquake risk, were investigated by one-dimensional equivalent linear site response analysis. From ground response analyses, peak ground acceleration, predominant site period, 0.2-sec and 1-sec spectral accelerations and soil amplification maps of the study area were obtained for both near-field and far-field earthquake effects. The average acceleration spectrum obtained from analysis, for a near-field earthquake scenario, was found to exceed the design spectra of the Turkish Earthquake Code and Eurocode 8. Yet, the average acceleration spectrum was found to remain below the respective design spectra of the two codes for the far-field earthquake scenario. According to both near- and far-field earthquake scenarios in the study area, the low-rise buildings with low modal vibration durations are expected to be exposed to high spectral acceleration values and high-rise buildings with high modal vibration durations will be exposed to lower spectral accelerations. While high amplification ratios are observed in the north of the study area for the near-distance earthquake scenario, high amplification ratios are observed in the south of the study area for the long-distance earthquake scenario.