• 제목/요약/키워드: seismic attenuation

검색결과 144건 처리시간 0.02초

Stability improvement for response attenuation of bridge columns with one dimensional meta-material based isolation systems

  • Saumitra Jain;Sumiran Pujari;Arghadeep Laskar
    • Earthquakes and Structures
    • /
    • 제24권3호
    • /
    • pp.193-204
    • /
    • 2023
  • The concept of meta-material-based isolation systems (MMIS) for structural columns has been revisited in the present study in order to enhance the stability of rubber pads by using steel shim reinforced rubber (SSRR) layers. Analytical calculations have shown a significant improvement in the stability of MMIS with SSRR pads. Finite element analysis has also been conducted to further show the reduced response of a bridge with the modified MMIS under excitations having frequencies within the corresponding attenuation zone (AZ) as compared to the response of a conventional bridge without MMIS. FE analysis further shows the stress generated on the bridge with MMIS systems are within safe limits. Finally, a generalized procedure has been developed to design bridge columns with the proposed modified MMIS.

부분 동결된 소금물에서의 초음파감쇠에 대한 다공성탄성 모델 (A poroelastic model for ultrasonic wave attenuation in partially frozen brines)

  • Matsushima, Jun;Nibe, Takao;Suzuki, Makoto;Kato, Yoshibumi;Rokugawa, Shuichi
    • 지구물리와물리탐사
    • /
    • 제14권1호
    • /
    • pp.105-115
    • /
    • 2011
  • 유체를 포함하는 혼합 매질에서의 탄성파 고유 감쇠에 대한 다양한 메커니즘 중, 탄성파 전파 시 고체와 유체 사이에서의 상대적 운동은 가장 중요한 감쇠 메커니즘 중의 하나이다. 선행 연구에서는 얼음의 미세 공극 안에 존재하는 소금물이 초음파의 전파에 미치는 영향을 분석하기 위하여 얼음과 소금물이 공존하는 매질에서 초음파 전파 실험하였다. 부분적으로 동결된 소금물에서 각기 다른 온도에서의 초음파 감쇠의 물리적인 메커니즘을 350 ~ 600 kHz의 주파수 대역에서 규명하기 위하여, Biot 이론에 입각한 다공성의 탄생 모델을 도입하여 초음파의 전파를 측정하였다. 고체상은 얼음으로, 액체상은 소금물로 가정한 뒤 펄스 핵자기공명기술로 측정한 유체의 성질을 이용하여 각각의 온도에서의 공극률을 계산한 결과, 실험으로 측정한 감쇠값은 500 kHz에서 계산된 고유 감쇠값과 다르게 나타났으며 이는 squirt -flow 메커니즘과 파의 산란 효과와 같은 다른 감쇠 메커니즘도 고려해야 한다는 것을 의미한다.

국내 고층 비내진 철근콘크리트 벽식 아파트의 지진취약도 평가 (Seismic Fragility Assessment for Korean High-Rise Non-Seismic RC Shear Wall Apartment Buildings)

  • 전성하;신동현;박지훈
    • 한국지진공학회논문집
    • /
    • 제24권6호
    • /
    • pp.293-303
    • /
    • 2020
  • Seismic fragility was assessed for non-seismic reinforced concrete shear walls in Korean high-rise apartment buildings in order to implement an earthquake damage prediction system. Seismic hazard was defined with an earthquake scenario, in which ground motion intensity was varied with respect to prescribed seismic center distances given an earthquake magnitude. Ground motion response spectra were computed using Korean ground motion attenuation equations to match accelerograms. Seismic fragility functions were developed using nonlinear static and dynamic analysis for comparison. Differences in seismic fragility between damage state criteria including inter-story drifts and the performance of individual structural members were investigated. The analyzed building had an exceptionally long period for the fundamental mode in the longitudinal direction and corresponding contribution of higher modes because of a prominently insufficient wall quantity in such direction. The results showed that nonlinear static analyses based on a single mode tend to underestimate structural damage. Moreover, detailed assessments of structural members are recommended for seismic fragility assessment of a relatively low performance level such as collapse prevention. On the other hand, inter-story drift is a more appropriate criterion for a relatively high performance level such as immediate occupancy.

Modeling the impact of corrosion rate of stirrups on seismic performance of reinforced concrete columns

  • Abbas Ghasemi;Mohamad Sobhani
    • Earthquakes and Structures
    • /
    • 제24권3호
    • /
    • pp.183-192
    • /
    • 2023
  • It is essential to properly understand the seismic behavior of reinforced concrete (RC) columns confined by stirrups that experience different corrosion rates. The current study investigated the effect of seismic performance indicators such as strength loss, energy dissipation rate, ductility and hysteresis damping on specimens and models for different stirrup corrosion rates. Analysis revealed the adverse effects of corrosion on the bond performance between the concrete and steel bars which affected the seismic performance of the columns. It was found that with increasing corrosion rate, ductility and energy dissipation of the specimens decreased. Compared with the uncorroded specimen, the ductility factor and energy dissipation decreased observably, by 22.89% and 60.64%, respectively. An attenuation relationship is proposed for the corrosion rate of the stirrups for different stirrup yield strengths, concrete compressive strengths, concrete covers and stirrup spacing.

면진장치를 적용한 컴퓨터실 바닥의 지진응답해석 (Seismic Response Analysis of Computer Floors Using Base Isolation System)

  • 이경진
    • 한국지진공학회:학술대회논문집
    • /
    • 한국지진공학회 2000년도 추계 학술발표회 논문집 Proceedings of EESK Conference-Fall 2000
    • /
    • pp.424-431
    • /
    • 2000
  • After the Kobe earthquake(1995) in Japan, the Izmit earthquake(1997) in Turkey and the Chi-chi earthquake(1999) in Taiwan, the small-to-medium-sized earthquakes occurred in the Koreans peninsula and this shows the fact that Korea is not located in the safety zone of earthquake. The main concept of base isolation system is to reduce the member forces by decreasing the earthquake forces transmitted to superstructure instead of the conventional techniques of strengthening the structural members. This study investigates the effect of seismic response attenuation of computer floors using base isolation systems

  • PDF

지진 재해에 대한 전력 송전 네트워크 시스템의 신뢰성 평가 모형 (A Model for Seismic Reliability Assessment of Electric Power Transmission Network System)

  • 고현무;김영호;박원석
    • 한국지진공학회논문집
    • /
    • 제7권2호
    • /
    • pp.93-102
    • /
    • 2003
  • 지진 하중을 받는 전체 네트워크 시스템 및 네트워크 구성 절점에 대한 신뢰성 지수를 구할 수 있는 지진 재해 신뢰성 평가 방법을 전력 송전 네트워크 시스템을 대상으로 개발하였다. 전력 송전 시스템에 대하여 절점과 링크로 구성된 네트워크 모형을 개발하였으며, 절점인 변전소의 지진 취약도 곡선은 변전소 구성 기기의 개별 취약도 곡선으로부터 구하였다. 입력 지진 모형으로서 점 지진원 모형을 사용하였고, doubly truncated Gutenberg-Richter 관계식과 감쇠공식을 적용하였다. 몬테 카를로 시뮬레이션을 적용하여 전력 송전 네트워크 시스템의 신뢰성을 평가한 결과 한국의 전력망에 대한 지진 재해의 효과는 무시할 수 있는 수준은 아닌것으로 평가되었다.

Seismic attributes for characterization of a heavy-oil shaly-sand reservoir in the Muglad Basin of South Sudan

  • Deng, William A.;Kim, Taeyoun;Jang, Seonghyung
    • Geosciences Journal
    • /
    • 제22권6호
    • /
    • pp.1027-1039
    • /
    • 2018
  • Seismic attributes are often used to identify lithology and evaluate reservoir properties. However, interpretation based only on structural attributes and without knowledge of the Vp/Vs ratio can limit the ability to evaluate changes in heavy oil reservoirs. These limitations are often due to less obvious impedance differences. In order to investigate pieces of evidence of a heavy-oil shaly-sand reservoir from seismic data, besides geochemistry, we studied seismic attributes and characterized the reservoir using seismic stack data and well logging data. The study area was the Muglad rift basin in South Sudan. We conducted a seismic complex analysis to evaluate the target reservoir. To delineate the frequency responses of the different lithological units, we applied the spectral decomposition method to the target reservoir. The most unexpected result was continuous bands of strong seismic reflectors in the target reservoir, which extended across the borehole. Spectral decomposition analysis showed that the low-frequency zone of 25 Hz dominant frequency was consistent with instantaneous attributes. This approach can identify lithology, reveal frequency anomalies, and filter the stacked section into low- and high-frequency bands. The heavy-oil reservoir zones exhibited velocity attenuation and the amplitude was strongly frequency dependent.

기상청 지진관측보고(1978-2001)를 이용한 지진 특성의 정성적 평가 (The Qualitative Evaluation of Seismic Characteristics using the KMA Seismological Bulletin (1978-2001))

  • 박동희;연관희;최원학;장천중
    • 한국지진공학회:학술대회논문집
    • /
    • 한국지진공학회 2002년도 춘계 학술발표회 논문집
    • /
    • pp.12-19
    • /
    • 2002
  • A high frequency level of Fourier amplitude relates with stress drop and seismic moment. When we can not use this relation owing to absence of digital earthquake data, stress drop and seismic moment can be determined from Peak Ground Velocity(PGV) and felt area. We have qualitatively evaluated the seismic characteristics using PGV, and Magnitude from the well determined felt area in seismological records of Korea(1978~2001) by Korea Meteorological Administration(KMA). Observed relations between felt area and magnitude in the Korean Peninsula are explained by attenuation(Q), and stress drops comparing with the previous researches on stress parameter. This results are preliminary work for the study of stress parameter using the relationship of high frequency lavel, PGV, and felt area.

  • PDF

Dynamic simulation models for seismic behavior of soil systems - Part I: Block diagrams

  • Sahin, Abdurrahman
    • Geomechanics and Engineering
    • /
    • 제9권2호
    • /
    • pp.145-167
    • /
    • 2015
  • Digital simulation has recently become the preferred method for designing complex and dynamic systems. Simulation packages provide interactive, block-diagram environment for modeling and simulating dynamic models. The block diagrams in simulation models are flowcharts which describe the components of dynamic systems and their interaction. This paper is the first part of the study for determining the seismic behavior of soil systems. The aim of this part is to present the constructed block diagrams for discrete-time analysis of seismic site amplification in layered media for vertically propagating shear waves. Detailed block diagrams are constructed for single and multiple soil layers by considering wave propagation with and without damping, respectively. The block diagrams for recursive filter to model attenuation in discrete-time form are also constructed. Finite difference method is used for strain calculation. The block diagrams are developed by utilizing Simulink which is a software add-on to Matlab.