그루브의 Trap 효과에 대한 CFD 해석: 제 1부 − 그루브 단면 형상의 변화 (CFD Analysis of Trap Effect of Groove in Lubricating Systems: Part I - Variation in Cross-Sectional Shape of Groove)

  • 홍성호
    • Tribology and Lubricants
    • /
    • 제32권3호
    • /
    • pp.101-105
    • /
    • 2016
  • Trap effect of groove is evaluated in a lubricating system using computational fluid dynamics (CFD) analysis. The simulation is based on the standard k-ε turbulence model and the discrete phase model (DPM) using a commercial CFD code FLUENT. The simulation results are also capable of showing the particle trajectories in flow field. Computational domain is meshed using the GAMBIT pre-processor. The various grooves are applied in order to improve lubrication characteristics such as reduction of friction loss, increase in load carrying capacity, and trapping of the wear particles. Trap effect of groove is investigated with variations in cross-sectional shape and Reynolds number in this research. Various cross-sectional shapes of groove (rectangular, triangle, U shaped, trapezoid, elliptical shapes) are considered to evaluate the trap effect in simplified two-dimensional sliding bearing. The particles are assumed to steel, and defined a single particle injection condition in various positions. The “reflect” boundary condition for discrete phase is applied to the wall boundary, and the “escape” boundary condition to “pressure inlet” and “pressure outlet” conditions. The streamlines are compared with particles trajectories in the groove. From the results of numerical analysis in the study, it is found that the cross-sectional shapes favorable to the creation of vortex and small eddy current are effective in terms of particle trapping effect. Moreover, it is found that the Reynolds number has a strong influence on the pattern of vortex or small eddy current in the groove, and that the pattern of the vortex or small eddy current affects the trap effect of the groove.

볼류트 형상이 원심 펌프의 성능에 미치는 영향에 대한 수치 해석적 연구 (A Numerical Study on the Effect of Volute Geometry on the Performance of Centrifugal Pump)

  • 김덕수;전상규;윤준용;최영석
    • 한국유체기계학회 논문집
    • /
    • 제9권2호
    • /
    • pp.44-49
    • /
    • 2006
  • In this study, the effects of volute area distribution on the performance of a centrifugal pump were numerically studied using a commercial CFD code. To reduce the shutoff head, maintaining head and efficiency at a design flow rate, the flat head-capacity characteristic curves in which the head varies only slightly with capacity from shutoff to design capacity are frequently required. In order to control the shutoff head of a pump, several volute cross-sectional area distributions were proposed as a main parameter with the same impeller geometry The calculation results show that the slope of the performance characteristic curve of the centrifugal pump can be controlled by modifying the area distribution from volute tongue to volute outlet with fixed volute outlet area and also varied volute outlet area.

Flexural performance of FRP-reinforced concrete encased steel composite beams

  • Kara, Ilker Fatih
    • Structural Engineering and Mechanics
    • /
    • 제59권4호
    • /
    • pp.775-793
    • /
    • 2016
  • This paper presents a numerical method for estimating the curvature, deflection and moment capacity of FRP-reinforced concrete encased steel composite beams (FRP-RCS). A sectional analysis is first carried out to predict the moment-curvature relationship from which beam deflection and moment capacity are then calculated. Comparisons between theoretical and experimental results of tests conducted elsewhere show that the proposed numerical technique can accurately predict moment capacity and deflection of FRP-RCS composite beam. The numerical results also indicated that beam ductility and stiffness are improved when encased steel is added to FRP reinforced concrete beams. ACI, ISIS and Bischoff models for deflection prediction compared well at low load, however, significantly underestimated the experimental results for high load levels.

십자형 연직배수재의 점성토지반 개량에의 적용성 (Applicability of Cross Shaped Drain to Soft Clay Improvement)

  • 장연수;김영우;김수삼
    • 한국지반공학회:학술대회논문집
    • /
    • 한국지반공학회 2000년도 토목섬유 특별세미나
    • /
    • pp.9-16
    • /
    • 2000
  • Applicability of the cross shaped drain in a soft clay ground is examined using the laboratory discharge capacity test, column consolidation test and 3-D numerical flow analysis. The equivalent diameter of the tested drains is back-calculated from the laboratory experiment and compared with those calculated from the formula suggested in the literature. The effective range of the cross shaped drain about the discharge capacity and coefficient of permeability is analyzed. The results of numerical analysis show that the cross shaped drain which has a cross-sectional area twice of the band shaped drain can reduce the consolidation time by 30% from that for the band shaped drain in a soft clay ground that K is over 1${\times}$10$\^$-7/cm/sec

  • PDF

화해를 입은 철근콘크리트 기둥의 구조성능 저하 (Deterioration of Structural Capacity of Fire-Damaged Reinforced Concrete Column)

  • 이차돈;신영수;홍성걸;이승환
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2003년도 가을 학술발표회 논문집
    • /
    • pp.371-374
    • /
    • 2003
  • The degree of changes in mechanical properties of fire-damaged reinforced concrete column depends mostly on sectional geometry, duration exposed to fire, and moisture containment. In order to reasonably assess the deterioration of structural capacity of fire-damaged reinforced concrete column, it is necessary to develop a theoretical model predicting column behavior based on nonlinear heat transfer equation in addition to the traditional mechanics. This research focuses on the development of theoretical model to predict moment-curvature relations of fire-damaged reinforced column. The model is used for the assessment of structural capacity of fire-damaged column in terms of moment-curvature relations and PM interaction curves.

  • PDF

준설매립지반의 안정처리를 위한 수평배수재의 공학적 특성 (Engineering Characteristics of Horizontal Drainage for Stabilization of Dredged Fill)

  • 이상호;박정용;장연수;박정순;김수삼
    • 한국지반공학회:학술대회논문집
    • /
    • 한국지반공학회 2001년도 봄 학술발표회 논문집
    • /
    • pp.563-570
    • /
    • 2001
  • In this study, the charactersistics of horizontal drains used to stabilize the dredged fill are investigated experimentally by doing tensile strength test, discharge capacity test, and filter clogging test. The types of the drains selected for the study are filament type (Tyre-E), embossed type(Type-P) and heat bonded cubic type with the thickness 10mm(Type-010) and 5mm(Type-05). The results of tensile strength and discharge capacity test show that the performance of drain Type-O10 was better than the other drains. This is caused by the fact that the lattice shape core of drain Type-O10 has strong rigidity and minimizes the loss of the sectional area of discharge with increased confining pressure. Analyzing the compatibility of filters by the results of the strength characteristics test and clogging test, the filter of filament type drain produced with polyester clothed polyamide performed well.

  • PDF

볼류트 형상이 원심 펌프의 성능에 미치는 영향에 대한 수치 해석적 연구 (A Numerical Study on the effect of Volute Geometry on the Performance of Centrifugal Pump)

  • 김덕수;최영석;전상규;윤준용
    • 유체기계공업학회:학술대회논문집
    • /
    • 유체기계공업학회 2005년도 연구개발 발표회 논문집
    • /
    • pp.497-502
    • /
    • 2005
  • In this study. the effect of volute area distribution on the performance of a centrifugal pump were numerically studied using a commercial CFD code. To reduce the shutoff head, maintaining head and efficiency at a design flow rate. the flat head-capacity characteristic curves in which the head varies only slightly with capacity from shutoff to design capacity are frequently required. In order to control the shutoff head of a pump, several volute cross-sectional area distributions were proposed as a main parameter with the same impeller geometry. The calculation results show that the slope of the performance characteristic curve of the centrifugal pump can be controlled by modifying the area distribution from volute tongue to volute outlet with fixed volute outlet area and also varied volute outlet area.

  • PDF

Ultimate flexural and shear capacity of concrete beams with corroded reinforcement

  • Bhargava, Kapilesh;Ghosh, A.K.;Mori, Yasuhiro;Ramanujam, S.
    • Structural Engineering and Mechanics
    • /
    • 제27권3호
    • /
    • pp.347-363
    • /
    • 2007
  • Assessment of structural behaviour of corrosion affected structures is an important issue, which would help in making certain decisions pertaining to the inspection, repair, strengthening, replacement and demolition of such structures. The paper presents formulations to predict the loss of weight and the loss of cross-sectional area of the reinforcing bar undergoing corrosion based on the earlier study carried out by the present authors (Bhargava et al. 2006). These formulations have further been used to analytically evaluate the ultimate bending moment and ultimate shear force capacity of the corroded concrete beams. Results of the present study indicate that, a considerably good agreement has been observed between the experimental and the analytically predicted values for the weight loss and reduction in radius of the corroded reinforcing bars. A considerably good agreement has also been observed between the experimental and the analytically predicted values of ultimate bending moment and ultimate shear force capacity for the corroded concrete beams.

Rehabilitation of corroded circular hollow sectional steel beam by CFRP patch

  • Setvati, Mahdi Razavi;Mustaffa, Zahiraniza
    • Steel and Composite Structures
    • /
    • 제32권1호
    • /
    • pp.127-139
    • /
    • 2019
  • Bridges, offshore oil platforms and other infrastructures usually require at some point in their service life rehabilitation for reasons such as aging and corrosion. This study explores the application of adhesively bonded CFRP patches in repair of corroded circular hollow sectional (CHS) steel beams. An experimental program involving three-point bending tests was conducted on intact, corroded, and repaired CHS beams. Meso-scale finite element (FE) models of the tested beams were developed and validated by the experimental results. A parametric study using the validated FE models was performed to examine the effects of different CFRP patch parameters, including patch dimensions, number of plies and stacking sequence, on efficiency of the repair system. Results indicates that the corrosion reduced elastic stiffness and flexural strength of the undamaged beam by 8.9 and 15.1%, respectively, and composite repair recovered 10.7 and 18.9% of those, respectively, compared to undamaged beam. These findings demonstrated the ability of CFRP patch repair to restore full bending capacity of the corroded CHS steel beam. The parametric study revealed that strength and stiffness of the repaired CHS beam can be enhanced by changing the fiber orientations of wet composite patch without increasing the quantity of repair materials.

모래지반에 매입된 날개없는 석션앵커의 인발력에 대한 원심모형실험 (Centrifuge Model Tests on the Pullout Capacity of Embedded Suction Anchor without Flanges in Sand layer)

  • 김경오;김유석;고부현
    • 한국지반공학회:학술대회논문집
    • /
    • 한국지반공학회 2005년도 지반공학 공동 학술발표회
    • /
    • pp.517-520
    • /
    • 2005
  • The embedded suction anchor(ESA) is and anchor that is driven by a suction pile. The cross-sectional shape of the ESA anchor is circle. Its diameter is the same as that of the suction pile that is used to drive it into the seafloor. For the installation, the anchor is attached to the tip of the suction pile and then driven as a unit with the pile by and applied suction pressure. Once the ESA anchor reaches the desired depth, the pile is retrieved by applying a positive pressure. Finally, only the ESA anchor remains in the soil layer. This paper presents the results of centrifuge model tests to investigate ESA pullout capacity. The main parameters that have effects on the pullout capacity of ESA may include g-level, embedded depth, direction of loading, and loading point. The results of tests show that the pullout loading capacities increase as the loading point shift toward the tip of the anchors for a given loading direction. They also indicate that the loading point associated with the maximum pullout loading capacity is located at approximately 67 percent of the anchor length from the top for the horizontal load.

  • PDF