• Title/Summary/Keyword: section insulator

Search Result 29, Processing Time 0.023 seconds

A Case Study of Degradation Characteristics for Rod-Insulator on Catenary System in Electric Railway (전기철도 전차선로 지지애자의 염해지역 열화특성 사례 연구)

  • Jung, Hosung;Park, Young
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.32 no.4
    • /
    • pp.263-266
    • /
    • 2019
  • In the Airport Railroad, the Yeongjong Bridge has a length of 4,420 m and connects Yeongjong Island with the mainland of Incheon City. The bridge is a two-level structure, consisting of a six-lane road at the upper level and a combination of a road and railroad at the lower level. The environmental conditions for the electric railway come mainly from the salt injury area and a heavy industry zone, and the maintenance cycles are determined differently depending on these conditions. This study analyzed the deterioration characteristics of long rod insulators produced with a movable ceramic bracket and polymer materials in the Yeongjong Bridge section of the Airport Railway operating in the salt injury area according to the material characteristics. Comparison of the corona measurements when the insulators were cleaned at the same time showed that the polymer insulator had a higher insulation performance than the ceramic insulator.

The Verification of Breakage Possibility and Vibration Properties of Glass Insulators by the High-speed Railway Service (KTX 운행에 따른 가선설비 유리애자의 진동특성과 파손 가능성 검증)

  • Kim, Young-Seok;Shong, Kil-Mok;Jung, Jin-Su;Jeon, Yong-Joo
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.58 no.3
    • /
    • pp.566-572
    • /
    • 2009
  • This paper has studied breakage possibility of glass insulators by resonance and accelerated deterioration through the comparison of the natural vibration and on site vibration. The natural frequencies of the strut tube glass insulator was measured within a range of less than 1kHz. In the on site vibration, the largest frequency that was imposed on strut tube glass insulators was 80Hz with 1.13g of vertical vibration in the viaduct section, the largest vertical vibration (0.38g) was detected at 103Hz in the open route section. When site vibration and natural vibration of strut tube glass insulators were compared in terms of characteristics, the resonance frequency was not the same. In both the viaduct and open route sections, it seems that the impact by vertical vibration in strut tube glass insulators is large. It's very unlikely that glass insulators were damaged by fatigue accumulation of vibration since the possibility of damage by resonance was very low in consideration of the characteristics of natural vibration and site vibration of glass insulators. In addition, no damage was detected in the accelerated deterioration test.

The research for the application of polymer support insulator used in DC railway system (직류전기철도에서의 고분자 지지애자 적용에 관한 연구)

  • Lee, Gi-Sung;Kim, Yoon-Sik;Sim, Jae-Suk;Jung, Ho-Sung;Lee, Ki-Won;Cho, Ho-Ryung
    • Proceedings of the KSR Conference
    • /
    • 2009.05a
    • /
    • pp.371-377
    • /
    • 2009
  • The use of polymer insulator has increased all over the world. As of 2000's KEPCO has used it fully since they introduced it in early 1990's. In Korea it is very widely used by KORAIL which uses AC 25 kV system in the ground electric car line. And It is also used in tunnel electric car line to support AT feeder line. But it has not been used in the section of DC 1500 V. In case of DC 1500 V electric railway system It is has been developed by research institutes by means of R&D projects since 2008. The user cleans porcelain insulators regularly by water because of dusts and pollution. In case of polymer insulators It is very easy to be made dirty by pollution because of the material properties and hard to be cleaned by cleansing. In accordance with these reasons It is worried about deterioration. This paper deals with anticipating problems when we apply it to DC electric railway system and the procedure for testing polymer support insulator.

  • PDF

A Novel Body-tied Silicon-On-Insulator(SOI) n-channel Metal-Oxide-Semiconductor Field-Effect Transistor with Grounded Body Electrode

  • Kang, Won-Gu;Lyu, Jong-Son;Yoo, Hyung-Joun
    • ETRI Journal
    • /
    • v.17 no.4
    • /
    • pp.1-12
    • /
    • 1996
  • A novel body-tied silicon-on-insulator(SOI) n-channel metal-oxide-semiconductor field-effect transistor with grounded body electrode named GBSOI nMOSFET has been developed by wafer bonding and etch-back technology. It has no floating body effect such as kink phenomena on the drain current curves, single-transistor latch and drain current overshoot inherent in a normal SOI device with floating body. We have characterized the interface trap density, kink phenomena on the drain current ($I_{DS}-V_{DS}$) curves, substrate resistance effect on the $I_{DS}-V_{DS}$ curves, subthreshold current characteristics and single transistor latch of these transistors. We have confirmed that the GBSOI structure is suitable for high-speed and low-voltage VLSI circuits.

  • PDF

Performance Standard Review of Section Insulator and Post Insulator for Overhead Conductor Rail (강체전차선로용 장간애자 및 절연구분장치 성능기준 검토)

  • Cho, Ho Rung;Lee, Sang Sik;Kim, Jae Sang;Lee, Kiwon;Park, Younchul
    • Proceedings of the KIEE Conference
    • /
    • 2015.07a
    • /
    • pp.1589-1590
    • /
    • 2015
  • 전기철도차량에 전기를 공급하는 가공 전차선로 시스템은 커티너리(catenary) 방식과 강체가선 방식으로 구분 할 수 있으며 강체가선 방식은 DC 급전구간에서 주로 사용하고 있는 T-bar 시스템과 AC 급전구간에서 주로 사용하는 R-bar 시스템으로 구분 할 수 있다. 최근 국내환경에 적합한 고속용 R-bar 시스템의 개발을 진행하고 있으며 여기에 필요한 브래킷 지지 및 절연용 장간애자와 동상구분을 위한 절연구분장치 개발을 진행하고 있다. 따라서 국내에 수입하여 적용하고 있는 저속, 고속 R-bar 시스템용 장간애자 및 절연구분장치의 성능기준을 확인하고 개발에 필요한 성능기준을 검토 적용하여 고속 R-bar 시스템용 장간애자 및 절연구분장치 개발을 진행할 예정이다.

  • PDF

Quantitative Distribution of Created Voids by Applying General Flame and DC Short-circuit Current to 2.5 mm2 HIV (2.5 mm2 HIV에 일반화염 및 DC 단락 전류를 인가하여 생성된 기공의 정량적 분포 해석)

  • Kim, Seung-Sam;Choi, Chung-Seog
    • Journal of the Korean Society of Safety
    • /
    • v.28 no.4
    • /
    • pp.38-42
    • /
    • 2013
  • This study performed the quantitative distribution analysis of created voids to an insulator when applying general flame and DC short-circuit current to 2.5 $mm^2$ HIV (600 V Grade Heat-Resistant Polyvinyl Chloride Insulated Wires). The diameter of cross-section of HIV normal product and the radius of conductor were measured to be 3.3 mm and 1.8 mm. The exterior of HIV exposed to general flame showed severe carbonization and its interior exhibited voids created by dechlorination reaction. This study observed the characteristics that, when the shortcircuit current applied for 2 seconds from a DC 12 V lead battery, the conductor and neighboring insulator were melted, causing the insulator adhering to the conductor. On average, 87 voids were created on 10 mm of the HIV. The average diameter of voids was 0.25 mm. In addition, it was found that, when the short-circuit current applied for 4 seconds, the interior of insulator in contact with conductor severely carbonized and showed exfoliation phenomenon. On average, 47 voids were created, with more voids at the bottom. The average diameter of voids was 0.20 mm. When the short-circuit current for 6 seconds, most parts of upper part of conductor was carbonized, 20 voids were created. The average diameter of voids was measured to be 0.24 mm. It could be seen that the created voids received little influence by the type of energy source and the number of created voids was reduced as the energy supply time increased.

An Experimental Study on the Improvement of City Gas Buried Double Piping Integrity (도시가스 매설이중배관 건전성 향상에 관한 실험적 연구)

  • Lim, Hyung-Duk
    • Journal of the Korean Society of Industry Convergence
    • /
    • v.23 no.5
    • /
    • pp.757-763
    • /
    • 2020
  • City gas buried pipes are managed by corrosion protection to prevent corrosion. In the case of the press-in section, the double pipe and the main pipe may cause corrosion under the influence of stray current, which can shorten the life of the pipes. In addition, if the insulator is filled in the press-in section, the press-in section itself is a single structure, and can be directly affected by external impact, and when the surrounding ground subsidence occurs, the stress may be concentrated, resulting in serious consequences. In this study, a serration-type shock absorber in the form of a sliding support was proposed as a new buried double piping construction method using EPS. The serration-type shock absorber can contribute to the improvement of the integrity of the buried double piping, as it can utilize the gas piping's own ductility and stress distribution characteristics with proper anti-corrosion management and shock-absorbing material properties by preventing contact inside the buried double pipe. However, for application to ground piping, there remains a task to supplement the vulnerability against fire due to the characteristics of EPS materials.

A Study on Selection of Cleaning Period and Pollution Analysis of Insulators in Tunnel (터널 애자류 오염도 분석과 세정주기 선정에 관한 연구)

  • Kim, Young-Seok;Shong, Kil-Mok;Choi, Myeong-Il
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.24 no.4
    • /
    • pp.149-155
    • /
    • 2010
  • This paper was carried out to estimate pollution levels of various insulators in tunnel and establish cleaning period in each tunnel section. We estimate pollution level that is attached to insulators in environmental pollution area, industrial area, salt damage area. These results that the pollution quantity and conductivity were increased by pollution accumulation period. However, the conductivity showed each other big difference in each tunnel. In particular, the conductivity showed big in environmental pollution(tunnel A) and salt damage(tunnel C) area, It is considered to prevent accident that manage establishing periodic state of cleaning plan. Also, the Grease that spread on the insulator surface in existing is considered that it can prevent accident for long-term by restrain use.

Effect of Metallic Particles on E-field Enhancement in Extra High Voltage Gas-insulated Transmission Lines

  • Rao, M. Mohana;Satyanarayana, S.;Kumar, S. Vinay;Jain, H.S.
    • Journal of Electrical Engineering and Technology
    • /
    • v.5 no.4
    • /
    • pp.631-636
    • /
    • 2010
  • Gas-insulated transmission lines (GITL) are valued as technological solutions in hydro-power stations due to their enormous power handling capabilities. The performance of GITL is a function of the size of metallic particles inside the gas-insulated chamber. Electrostatic field (E-field) enhancement is a common phenomenon in gas-insulated lines due to these metallic particles. In this study, the E-field enhancement factor is calculated by considering metallic particles at various locations in the gas-insulated line/bus section, such as high-tension (HT) conductor, high-voltage shields, support insulator, and inner surface of grounded enclosure. For this purpose, a two-dimensional model based on finite element (FE) method is developed. The length of the metallic particle is in the range of 1 to 10 mm while the diameter is between 1 to 3 mm. E-field enhancement is also computed for various particle configurations of the gas-insulated system, with focus on dielectric coating made of epoxy on HT conductor and inner surface of grounded enclosure.

A Development of Test Equipment for Thermal Protection Performance on Insulator used in Rocket Motor Chamber (연소관 내열고무의 내열성능평가를 위한 시험장치 개발)

  • Kang, YoonGoo;Park, JongHo
    • Journal of the Korean Society of Propulsion Engineers
    • /
    • v.20 no.3
    • /
    • pp.32-36
    • /
    • 2016
  • Test equipment was designed and manufactured to evaluate thermal reaction characteristic of internal insulators of solid rocket motor. Test is allowed up to chamber pressure 2,500 psi, burn-time 100 s. A cross section of test sample part is quadrature, and various test samples can be comparable at the same time. Inner temperature of test sample can be measured by thermocouples during burning. Test was executed in condition of efficient average chamber pressure 1,000 psi, efficient burn-time 10 s and safety of equipment was confirmed. Basic data for understanding thermal characteristics of internal insulator, that is, pressure-time curve, temperature-time curve in the test sample, and thermal destruction thickness of test sample was gained successfully.