The sealing Characteristics of sealing glasses and Mn-Zn single crystal ferrite (봉착용 유리와 Mn-Zn 단결정 Ferrite와의 봉착특성에 관한 연구)

  • Yun, Seong-Gi;Han, Joong-Hee;Gang, Won-Ho
    • Korean Journal of Materials Research
    • /
    • v.1 no.4
    • /
    • pp.221-228
    • /
    • 1991
  • In this study we have investigated the sealing characteristics of glasses suitable for producing the magnetic gap of the ferrite head cores which have been widely used for VTR and computer magnetic heads. $PbO-B_2O_3$ g1asses were evaluated by measuring microhardness, thermal expansion coefficient and sliding wear resistance. Concentration distribution of elements at the interface was observed by WDS. wettability was measured by high temperature microscopy. The results were as follows ; 1. In sealing glasses of $PbO-B_2O_3$ system, thermal expansion coefficient and wear volume were increased with increasing PbO content, and were decreased with increasing $B_2O_3$ content. 2. The contact angle of $PbO-B_2O_3$ Systems was mainly influenced by PbO content. 3. The sealing temperature showed a tendency to decrease proportionally with the increase of the coefficient of thermal expansion. 4. The diffusion at the interface between Mn-Zn single crystal ferrite and sealing glasses of $PbO-B_2O_3$ system was dominated by small amount of diffusion of ferrite content into glass part, which was very little affected by sealing heat treatment time.

  • PDF

Fabrication of Triode-Type CNT-FED by A Screen-printing of CNT Paste

  • Kwon, Sang-Jik;Shon, Byeong-Kyoo;Chung, Hak-June;Lee, Sang-Heon;Choi, Hyung-Wook;Lee, Jong-Duk;Lee, Chun-Gyoo
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 2004.08a
    • /
    • pp.866-869
    • /
    • 2004
  • A carbon nanotube field emission display(CNT FED) panel with a 2 inch diagonal size was fabricated by using a screen printing of a prepared photo-sensitive CNT paste and vacuum in-line sealing technology. After a surface treatment of the patterned CNT, only the carbon nanotube tips are uniformly exposed on the surface. The diameter of the exposed CNTs are usually about 20nm. The sealing temperature of the panel was around 390 $^{\circ}C$ and the vacuum level was obtained with $1.4{\times}10^{-5}$torr at the sealing. The field emission properties of the diode type CNT FED panel were characterized Now, we are developing a triode type CNT FED with a self-aligned gate-emitter structure.

  • PDF

V2O5-P2O5-ZnO-Sb2O3 Glass Frit Materials with BaO and Al2O3 for Large-sized Dye-sensitized Solar Cell Sealing

  • Lee, Han Sol;Cho, Jae Kwon;Hwang, Jae Kwon;Chung, Woon Jin
    • Journal of the Korean Ceramic Society
    • /
    • v.52 no.2
    • /
    • pp.114-118
    • /
    • 2015
  • $V_2O_5-P_2O_5-ZnO-Sb_2O_3$ glasses modified with BaO and $Al_2O_3$ are synthesized as a sealing material for large-scale dye-sensitized solar cells (DSSCs). A compositional study is performed in order to determine the glass that can be sintered below $500^{\circ}C$ with a high chemical stability against the electrolyte. The flow size of the glasses after the heat treatment and the glass stability are increased with the addition of $Al_2O_3$ and BaO, while the glass transition temperature is decreased. After the reaction with the electrolyte at $60^{\circ}C$ for 72 h, the addition of 5 mol% of BaO and 2 mol% of $Al_2O_3$ considerably enhances the chemical stability of the glass. X-ray diffraction (XRD) and scanning electron microscope (SEM) are used to examine the reaction between the electrolyte and glasses. The structural contribution of the additives is also investigated and discussed.

Effect of Sealing Treatment on Solid Particle Impingement Erosion of Al-Zn-Zr Thermal Spray Coating Layer (Al-Zn-Zr 용사코팅층의 고체입자 충돌 침식특성에 미치는 봉공처리의 영향)

  • Heo, Ho-Seong;Kim, Seong-Jong
    • Corrosion Science and Technology
    • /
    • v.21 no.1
    • /
    • pp.68-76
    • /
    • 2022
  • Several technologies are employed to protect substrates from corrosion and erosion damage. In particular, arc thermal spray coating technology is widely used as anti-corrosive technology for steel and concrete structures and is applied to offshore plants and petrochemical and drilling facilities. In this investigation, solid particle impingement erosion experiments were performed on an arc thermal spraying-coated specimen using 85% Al-14% Zn-1% Zr wire rod in KR-RA steel. This study investigated the effect of fluorosilicone sealing on the erosion resistance characteristics of the thermal spray coating layer. The erosion rates of the thermal spray-coated and sealed specimens were 4.1×10-4 and 8.5×10-4, respectively. At the beginning of the experiment, the fluorosilicone sealant was almost destroyed by the impact of the solid particles. The destruction time for the coating layer was 10 minutes for the thermal spray-coated specimen and 13 minutes for the sealed specimens, indicating that the sealed specimens had better erosion resistance characteristics to solid particle impingement.

Tightness of specimen sealing box in 20 L test chamber to evaluate building materials emitting pollutants (건축자재에서 방출되는 오염물질 평가 시 사용되는 20 L 시험챔버 시편홀더의 기밀성 개선)

  • Shin, Woo Jin;Lee, Chul Won;Kim, Man Goo
    • Analytical Science and Technology
    • /
    • v.20 no.4
    • /
    • pp.261-267
    • /
    • 2007
  • The 20 L small chamber test method is to evaluate pollutants such as TVOC, formaldehyde emitted from building materials. This method was only designed to evaluate the surface emission of sample exposed in the chamber. In this method, building materials cut with a fixed standard size are fixed in a sample sealing box. The sample sealing box is put into the 20 L test chamber. This chamber is ventilated at a standard air change rate with purified air for 7 days then the sample from the chamber is collected and analyzed to measure the emission rate of TVOC and formaldehyde. In this method, however, if the sealing box does not guarantee airtightness, accurate evaluation for the building materials can not be achieved due to the pollutants emitted from edge of the sample so called, edge effect. This edge effect can be much greater when evaluating panels such as plywood, flooring due to their surface treatment. In this study, flooring was tested to check airtightness of the sample sealing box with analytic results between 1L and 20 L test chamber. Furniture materials like LPM coated one side surface treatment and MDF coated both sides surface treatment with LPM were tested to identify whether the improvement of the sample sealing box airtightness is possible with the comparison between existing and improved test method that low VOC emission tape was used to seal the sample edge. After 7 days, MDF TVOC emission rate was different according to the existence and nonexistence of tape. The emission rate of the existing test method was $0.009mg/m^2h$ and that of improved test method was $0.003mg/m^2h$. Relative standard deviation for the existing test method was $0.004mg/m^2h$ and relative standard deviation for the improved test method was $0.002mg/m^2h$ when the same sample was analyzed three times. The improved test method in this study using low VOC emission tape was effective and able to reduce the heterogeneous effect of the edge from the sample sealing box.

Bonding Mechanism of Direct Copper to Glass Seal in an Evacuated Tube Solar Collector (태양열 집열기에 사용되는 구리-유리관 접합기구)

  • 김철영;남명식;곽희열
    • Journal of the Korean Ceramic Society
    • /
    • v.38 no.11
    • /
    • pp.1000-1007
    • /
    • 2001
  • In an evacuated tube solar collector, the stable sealing of the heat pipe to the glass tube is important for the collector to use for a long period of time. The sealing of copper tube to the glass is quite difficult because of the large differences in the physical and chemical properties of the two materials. In this study, therefore, a proper copper oxide layer was induced to improve the chemical bonding of the two materials, and the oxidation state of copper and the interface between copper and glass were examined by XRD, SEM and EDS. Its bonding strength was also measured. Cu$_2$O was formed when the bare copper was heat-treated under 600$^{\circ}C$, while CuO oxide layer was formed above that temperature. The bonding state of CuO to the copper was very poor. The borate treatment of the copper, however, extend the stable forming of Cu$_2$O layer to 800$^{\circ}C$. Borosilicate glass tube was sealed to a copper tube by Housekeeper method only when the sealing part was covered with Cu$_2$O layer. The bonding strength at the interface was measured 354.4N, its thermal shock resistance was acceptable.

  • PDF

Comparison of the sealing ability of various bioceramic materials for endodontic surgery

  • Benjamin Rencher ;Ana M. Chang ;Hanson Fong;James D. Johnson;Avina Paranjpe
    • Restorative Dentistry and Endodontics
    • /
    • v.46 no.3
    • /
    • pp.35.1-35.11
    • /
    • 2021
  • Objectives: Endosequence Bioceramic Root Repair Material (BC-RRM) is used in endodontic microsurgery. It is available as a paste and a putty. However, no studies to date have examined the sealing ability of these forms alone or in combination as root-end filling materials. Hence, this study aimed to compare the sealing properties of these 2 forms of BC-RRM. Materials and Methods: Forty-two extracted upper anterior teeth were divided into 3 experimental groups, a positive and negative control. After the root canal treatment, the root ends were resected, retroprepared and retrofilled with either putty, paste + putty or mineral trioxide aggregate (MTA). The teeth were mounted in tubes so the apical 3 mm was submerged in Brain Heart Infusion (BHI) broth. The coronal portions of the canals were inoculated with Enterococcus faecalis and BHI broth and incubated for 30 days. The broth in the tubes was analyzed for colony forming units to check for leakage of bacteria from the canal. The teeth from the groups were sectioned and analyzed using scanning electron microscopy (SEM). The Kruskal-Wallis test and analysis of variance were used to analyze the data with a significance level p < 0.05. Results: The BC-RRM and MTA groups showed similar sealing ability. The positive control showed leakage in all samples. The SEM imaging showed the presence of bacteria in all experimental groups at the material-tooth interface. Conclusions: No significant differences were noted in the experimental groups, providing sufficient evidence that any combination could be effectively used during endodontic microsurgery.

Satisfaction of Elementary School Students's Parents with the Pit & Fissure Sealing Program in Some Regions (일부지역 초등학생 학부모의 치면열구전색에 관한 만족도)

  • Hwang, Ji-Min;Han, Ji-Hyoung
    • Journal of dental hygiene science
    • /
    • v.9 no.4
    • /
    • pp.469-474
    • /
    • 2009
  • The purpose of this study was to examine the satisfaction level of parents with elementary school students in some metropolitan areas with the pit and fissure sealing program in a bid to raise awareness of the importance of the preventive treatment and accelerate the spread of it. The subjects in this study were 231 parents who had school children and resided in Seoul and Gyeonggi Province. After a self-administered survey was conducted in October and November 2008, the collected data were analyzed. The findings of the study were as follows; 1. As to places for receiving the preventive treatment, 111 respondents (48.1%) experienced pit and fissure sealing in dental clinics, and 88 respondents(38.1%) did that in dental hospitals. 177 people(76.6%) received that treatment from dentists, and 16 respondents(11.3%) did that from dental hygienists. 2. Concerning whether to be for or against the pit and fissure sealing program, more than half that numbered 143(61.9%) supported that program, and 88 respondents(38.1%) didn't. As for satisfaction level, they expressed the biggest satisfaction with the preventive effect of that treatment($3.92{\pm}.85$), and were least satisfied with the cost($1.91{\pm}.86$). 3. Regarding links between general characteristics and satisfaction level, they were statistically significantly different in satisfaction level with the cost according to residential area and the number of child, and age made a statistically significant difference to their satisfaction level with the preventive effect of it. 4. As for relationship between warranty term and whether to be for the pit and fissure sealing program or not, 45(31.5%) out of those who supported the program were provided with no warranty, and 32(36.4%) out of those who took a stand against it were provided with no warranty, either. Warranty was provided to 12(8.4%) respondents of the former group without a fixed term, but that's not the case for any of the latter. The warranty term made statistically significant differences to their agreement or disagreement to the program(p<0.05).

  • PDF

THE EFFECT OF SCREW HOLE SEALING METHOD ON ABUTMENT SCREW LOOSENING IN DENIAL IMPLANT (임플랜트 보철물의 나사구멍 봉쇄방법이 지대나사 풀림에 미치는 영향에 관한 연구)

  • Lim, Jae-Bin;Yim, Soon-Ho;Cho, In-Ho
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.35 no.4
    • /
    • pp.767-780
    • /
    • 1997
  • One of the most common problems of implant prosthesis is the screw loosening of abutment screws. This brings on discomfort in mastication, inflammation in the peri-implant tissue due to poor oral hygiene and fracture of prosthesis or loss of osseointegration. To prevent screw loosening, appropriate implantation to direct the occlusal force to the long axis of the implant, accurate design of the superstructure, decrease of the occlusal table, and adequate torque on the abutment screw are necessary. In this study the screw loosening torque was evaluated in implants with dimples or flutes in the internal surface of abutment screw holes. The abutments were fastened with slot type and hexagonal type abutment screws and were sealed with vinyl poly siloxane impression and bite registration material respectively. The screw loosening torque was evaluated after 1,800 and 12,600 times loading under a loading machine. The results were as follows. 1. The flute form group showed significantly higher loosening torque compared to the dimple form group and the group with no inner surface treatment (p<0.05). 2. There was no statistical difference in loosening torque according to the sealing materials. 3. The loosening torque according to the types of abutment screw showed no significant difference. 4. The loosening torque was significantly higher after 1800 times loading compared to 12600 times loading(p<0.05). From the above results. it is thought that formation of a flute in the internal surface of the screw hole decreases the chance of screw loosening, but the sealing materials and types of abutment screw did not show significant difference in prevention of screw loosening.