• Title/Summary/Keyword: scanning system

Search Result 2,485, Processing Time 0.036 seconds

The nanoleakage patterns of experimental hydrophobic adhesives after load cycling (Load cycling에 따른 소수성 실험용 상아질 접착제의 nanoleakage 양상)

  • Sohn, Suh-Jin;Chang, Ju-Hae;Kang, Suk-Ho;Yoo, Hyun-Mi;Cho, Byeong-Hoon;Son, Ho-Hyun
    • Restorative Dentistry and Endodontics
    • /
    • v.33 no.1
    • /
    • pp.9-19
    • /
    • 2008
  • The purpose of this study was: (1) to compare nanoleakage patterns of a conventional 3-step etch and rinse adhesive system and two experimental hydrophobic adhesive systems and (2) to investigate the change of the nanoleakage patterns after load cycling. Two kinds of hydrophobic experimental adhesives, ethanol containing adhesive (EA) and methanol containing adhesive (MA), were prepared. Thirty extracted human molars were embedded in resin blocks and occlusal thirds of the crowns were removed. The polished dentin surfaces were etched with a 35 % phosphoric acid etching gel and rinsed with water. Scotchbond Multi-Purpose (MP), EA and MA were used for bonding procedure. Z-250 composite resin was built-up on the adhesive-treated surfaces. Five teeth of each dentin adhesive group were subjected to mechanical load cycling. The teeth were sectioned into 2 mm thick slabs and then stained with 50 % ammoniacal silver nitrate. Ten specimens for each group were examined under scanning electron microscope in backscattering electron mode. All photographs were analyzed using image analysis software. Three regions of each specimen were used for evaluation of the silver uptake within the hybrid layer. The area of silver deposition was calculated and expressed in gray value. Data were statistically analyzed by two-way ANOVA and post-hoc testing of multiple comparisons was done with the Scheffe's test. Silver particles were observed in all the groups. However, silver particles were more sparsely distributed in the EA group and the MA group than in the MP group (p < .0001). There were no changes in nanoleakage patterns after load cycling.

Development of $^{166}Ho$-Stent for the Treatment of Esophageal Cancer (식도암 치료용 $^{166}Ho$-Stent 개발)

  • Park, Kyung-Bae;Kim, Young-Mi;Kim, Kyung-Hwa;Shin, Byung-Chul;Park, Woong-Woo;Han, Kwang-Hee;Chung, Young-Ju;Choi, Sang-Mu;Lee, Jong-Doo
    • The Korean Journal of Nuclear Medicine
    • /
    • v.34 no.1
    • /
    • pp.62-73
    • /
    • 2000
  • Purpose: Esophageal cancer patients have a difficulty in the intake of meals through the blocked esophageal lumen, which is caused by an ingrowth of cancer cells and largely influences on the prognosis. It is reported that esophageal cancer has a very low survival rate due to the lack of nourishment and immunity as the result of this. In this study a new radioactive stent, which prevents tumor ingrowth and restenosis by additional radiation treatment, has been developed. Materials and Methods: Using ${\ulcorner}HANARO{\lrcorner}$ research reactor, the radioactive stent assembly ($^{166}Ho$-SA) was prepared by covering the metallic stent with a radioactive sleeve by means of a post-irradiation and pre-irradiation methods. Results: Scanning electron microscopy and autoradiography exhibited that the distribution of $^{165/166}Ho\;(NO_3)$ compounds in polyurethane matrix was homogeneous. A geometrical model of the esophagus considering its structural properties, was developed for the computer simulation of energy deposition to the esophageal wall. The dose distributions of $^{166}Ho$-stent were calculated by means of the EGS4 code system. The sources are considered to be distributed uniformly on the surface in the form of a cylinder with a diameter of 20 mm and length of 40 mm. As an animal experiment, when radioactive stent developed in this study was inserted into the esophagus of a Mongrel dog, tissue destruction and widening of the esophageal lumen were observed. Conclusion: We have developed a new radioactive stent comprising of a radioactive tubular sleeve covering the metallic stent, which emits homogeneous radiation. If it is inserted into the blocked or narrowed lumen, it can lead to local destruction of the tumor due to irradiation effect with dilatation resulting from self-expansion of the metallic property. Accordingly, it is expected that restenosis esophageal lumen by the continuous ingrowth and infiltration of cancer after insertion of our radioactive stent will be decreased remarkably.

  • PDF

Usefulness of $^{18}F$-FDG Fusion PET for Diagnosing an Early Stage Cancer (조기 암 진단을 위한 $^{18}F$-FDG Fusion PET의 유용성)

  • Jeon, Jae-Hwan;Kim, Byeong-Jin;Lee, Hong-Jae;Kim, Jin-Eui;Kim, Hyun-Joo
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.14 no.2
    • /
    • pp.145-149
    • /
    • 2010
  • Purpose: Recently, $^{18}F$-FDG Fusion PET which has a high sensitivity for diagnosing cancer is being used for purpose of health examination. This study is to demonstrate that $^{18}F$-FDG fusion PET study is useful for diagnosing an early stage cancer. Materials and Methods: This research has been conducted with 2790 patients visited Seoul National University Hospital Healthcare System (SNUHHS) for $^{18}F$-FDG fusion PET study for a health examination from February, 2004 to December 2008. PET/CT images were acquired from skull base to femur after 1 hour from injecting $^{18}F$-FDG 0.14 mCi/kg to the patients. GEMINI GS (Philips, Netherlands) was used for scanning. Results: From February 2004 to December 2008, $^{18}F$-FDG Fusion PET study was performed for 99,009 patients among all patients who visited SNUHHS and 2,790 patients was performed. Diagnostic rate for malignant cancer was 0.95% for the patients who were not examined by $^{18}F$-FDG Fusion PET study. 1.94% was for the patients who were. The rate of malignant tumor was showed 10% and benign tumor was 90% among 542 patients who showed abnormality in the PET/CT images. Types and rates of malignant tumor showed thyroid cancer: 31.5%, lung cancer: 14.8%, stomach cancer: 9.3%, rectum cancer: 3.7%, breast cancer: 3.7%, metastasis cancer: 16.7%. Nonspecific lymph node in the mediastinum, physiologic uptake in the colon, diffuse mild hypermetabolism in bilateral thyroid gland were shown as a benign tumor. Conclusion: The diagnostic rate of malignant tumor with $^{18}F$-FDG Fusion PET for a purpose of health examination was relatively higher than general medical examination. Consequently, it is superior and useful for applying $^{18}F$-FDG Fusion PET study for health examination.

  • PDF

Direct Bonding of Si(100)/NiSi/Si(100) Wafer Pairs Using Nickel Silicides with Silicidation Temperature (열처리 온도에 따른 니켈실리사이드 실리콘 기판쌍의 직접접합)

  • Song, O-Seong;An, Yeong-Suk;Lee, Yeong-Min;Yang, Cheol-Ung
    • Korean Journal of Materials Research
    • /
    • v.11 no.7
    • /
    • pp.556-561
    • /
    • 2001
  • We prepared a new a SOS(silicon-on-silicide) wafer pair which is consisted of Si(100)/1000$\AA$-NiSi Si (100) layers. SOS can be employed in MEMS(micro- electronic-mechanical system) application due to low resistance of the NiSi layer. A thermally evaporated $1000\AA$-thick Ni/Si wafer and a clean Si wafer were pre-mated in the class 100 clean room, then annealed at $300~900^{\circ}C$ for 15hrs to induce silicidation reaction. SOS wafer pairs were investigated by a IR camera to measure bonded area and probed by a SEM(scanning electron microscope) and TEM(transmission electron microscope) to observe cross-sectional view of Si/NiSi. IR camera observation showed that the annealed SOS wafer pairs have over 52% bonded area in all temperature region except silicidation phase transition temperature. By probing cross-sectional view with SEM of magnification of 30,000, we found that $1000\AA$-thick uniform NiSi layer was formed at the center area of bonded wafers without void defects. However we observed debonded area at the edge area of wafers. Through TEM observation, we found that $10-20\AA$ thick amourphous layer formed between Si surface and NiSix near the counter part of SOS. This layer may be an oxide layer and lead to degradation of bonding. At the edge area of wafers, that amorphous layer was formed even to thickness of $1500\AA$ during annealing. Therefore, to increase bonding area of Si NiSi ∥ Si wafer pairs, we may lessen the amorphous layers.

  • PDF

An Assessment of the Accuracy of 3 Dimensional Acquisition in F-18 fluorodeoxyglucose Brain PET Imaging (3차원 데이터획득 뇌 FDG-PET의 정확도 평가)

  • Lee, Jeong-Rim;Choi, Yong;Kim, Sang-Eun;Lee, Kyung-Han;Kim, Byung-Tae;Choi, Chang-Woon;Lim, Sang-Moo;Hong, Seong-Wun
    • The Korean Journal of Nuclear Medicine
    • /
    • v.33 no.3
    • /
    • pp.327-336
    • /
    • 1999
  • Purpose: To assess the quantitative accuracy and the clinical utility of 3D volumetric PET imaging with FDG in brain studies, 24 patients with various neurological disorders were studied. Materials and Methods: Each patient was injected with 370 MBq of 2-[$^{18}F$]fluoro-2-deoxy-D-glucose. After a 30 min uptake period, the patients were imaged for 30 min in 2 dimensional acquisition (2D) and subsequently for 10 min in 3 dimensional acquisition imaging (3D) using a GE $Advance^{TM}$ PET system, The scatter corrected 3D (3D SC) and non scatter-corrected 3D images were compared with 2D images by applying ROIs on gray and white matter, lesion and contralateral normal areas. Measured and calculated attenuation correction methods for emission images were compared to get the maximum advantage of high sensitivity of 3D acquisition. Results: When normalized to the contrast of 2D images, the contrasts of gray to white matter were $0.75{\pm}0.13$ (3D) and $0.95{\pm}0.12$ (3D SC). The contrasts of normal area to lesion were $0.83{\pm}0.05$ (3D) and $0.96{\pm}0.05$ (3D SC). Three nuclear medicine physicians judged 3D SC images to be superior to the 2D with regards to resolution and noise. Regional counts of calculated attenuation correction was not significantly different to that of measured attenuation correction. Conclusion: 3D PET images with the scatter correction in FDG brain studies provide quantitatively and qualitatively similar images to 2D and can be utilized in a routine clinical setting to reduce scanning time and patient motion artifacts.

  • PDF

THE CURRENT STATUS OF BIOMEDICAL ENGINEERING IN THE USA

  • Webster, John G.
    • Proceedings of the KOSOMBE Conference
    • /
    • v.1992 no.05
    • /
    • pp.27-47
    • /
    • 1992
  • Engineers have developed new instruments that aid in diagnosis and therapy Ultrasonic imaging has provided a nondamaging method of imaging internal organs. A complex transducer emits ultrasonic waves at many angles and reconstructs a map of internal anatomy and also velocities of blood in vessels. Fast computed tomography permits reconstruction of the 3-dimensional anatomy and perfusion of the heart at 20-Hz rates. Positron emission tomography uses certain isotopes that produce positrons that react with electrons to simultaneously emit two gamma rays in opposite directions. It locates the region of origin by using a ring of discrete scintillation detectors, each in electronic coincidence with an opposing detector. In magnetic resonance imaging, the patient is placed in a very strong magnetic field. The precessing of the hydrogen atoms is perturbed by an interrogating field to yield two-dimensional images of soft tissue having exceptional clarity. As an alternative to radiology image processing, film archiving, and retrieval, picture archiving and communication systems (PACS) are being implemented. Images from computed radiography, magnetic resonance imaging (MRI), nuclear medicine, and ultrasound are digitized, transmitted, and stored in computers for retrieval at distributed work stations. In electrical impedance tomography, electrodes are placed around the thorax. 50-kHz current is injected between two electrodes and voltages are measured on all other electrodes. A computer processes the data to yield an image of the resistivity of a 2-dimensional slice of the thorax. During fetal monitoring, a corkscrew electrode is screwed into the fetal scalp to measure the fetal electrocardiogram. Correlations with uterine contractions yield information on the status of the fetus during delivery To measure cardiac output by thermodilution, cold saline is injected into the right atrium. A thermistor in the right pulmonary artery yields temperature measurements, from which we can calculate cardiac output. In impedance cardiography, we measure the changes in electrical impedance as the heart ejects blood into the arteries. Motion artifacts are large, so signal averaging is useful during monitoring. An intraarterial blood gas monitoring system permits monitoring in real time. Light is sent down optical fibers inserted into the radial artery, where it is absorbed by dyes, which reemit the light at a different wavelength. The emitted light travels up optical fibers where an external instrument determines O2, CO2, and pH. Therapeutic devices include the electrosurgical unit. A high-frequency electric arc is drawn between the knife and the tissue. The arc cuts and the heat coagulates, thus preventing blood loss. Hyperthermia has demonstrated antitumor effects in patients in whom all conventional modes of therapy have failed. Methods of raising tumor temperature include focused ultrasound, radio-frequency power through needles, or microwaves. When the heart stops pumping, we use the defibrillator to restore normal pumping. A brief, high-current pulse through the heart synchronizes all cardiac fibers to restore normal rhythm. When the cardiac rhythm is too slow, we implant the cardiac pacemaker. An electrode within the heart stimulates the cardiac muscle to contract at the normal rate. When the cardiac valves are narrowed or leak, we implant an artificial valve. Silicone rubber and Teflon are used for biocompatibility. Artificial hearts powered by pneumatic hoses have been implanted in humans. However, the quality of life gradually degrades, and death ensues. When kidney stones develop, lithotripsy is used. A spark creates a pressure wave, which is focused on the stone and fragments it. The pieces pass out normally. When kidneys fail, the blood is cleansed during hemodialysis. Urea passes through a porous membrane to a dialysate bath to lower its concentration in the blood. The blind are able to read by scanning the Optacon with their fingertips. A camera scans letters and converts them to an array of vibrating pins. The deaf are able to hear using a cochlear implant. A microphone detects sound and divides it into frequency bands. 22 electrodes within the cochlea stimulate the acoustic the acoustic nerve to provide sound patterns. For those who have lost muscle function in the limbs, researchers are implanting electrodes to stimulate the muscle. Sensors in the legs and arms feed back signals to a computer that coordinates the stimulators to provide limb motion. For those with high spinal cord injury, a puff and sip switch can control a computer and permit the disabled person operate the computer and communicate with the outside world.

  • PDF

Developing a Dental Unit Waterline Model Using General Laboratory Equipments (실험실 일반 장비를 이용한 치과용 유니트 수관 모델 개발)

  • Yoon, Hye Young;Lee, Si Young
    • Journal of dental hygiene science
    • /
    • v.16 no.4
    • /
    • pp.284-292
    • /
    • 2016
  • Water supplied through dental unit waterlines (DUWLs) has been shown to contain high number of bacteria. To reduce the contamination of DUWLs, it is essential to develop effective disinfectants. It is, however, difficulty to obtain proper DUWL samples for studies. The purpose of this study was to establish a simple laboratory model for reproducing DUWL biofilms. The bacteria obtained from DUWLs were cultured in R2A liquid medium for 10 days, and then stored at $-70^{\circ}C$. This stock was inoculated into R2A liquid medium and incubated in batch mode. After 5 days of culturing, it was inoculated into the biofilm formation model developed in this study. Our biofilm formation model comprised of a beaker containing R2A liquid medium and five glass rods attached to DUWL polyurethane tubing. Biofilm was allowed to form on the stir plate and the medium was replaced every 2 days. After 4 days of biofilm formation in the laboratory model, biofilm thickness, morphological characteristics and distribution of the composing bacteria were examined by confocal laser microscopy and scanning electron microscopy. The mean of biofilm accumulation was $4.68{\times}10^4$ colony forming unit/$cm^2$ and its thickness was $10{\sim}14{\mu}m$. In our laboratory model, thick bacterial lumps were observed in some parts of the tubing. To test the suitability of this biofilm model system, the effectiveness of disinfectants such as sodium hypochlorite, hydrogen peroxide, and chlorhexidine, was examined by their application to the biofilm formed in our model. Lower concentrations of disinfectants were less effective in reducing the count of bacteria constituting the biofilm. These results showed that our DUWL biofilm laboratory model was appropriate for comparison of disinfectant effects. Our laboratory model is expected to be useful for various other purposes in further studies.

Microstructural Study of Mortar Bar on Akali-Silica Reaction by Means of SEM and EPMA Analysis (알칼리-실리카 반응에 의한 모르타르 봉의 SEM과 EPMA 분석을 통한 미세구조 연구)

  • Jun, Ssang-Sun;Lee, Hyo-Min;Jin, Chi-Sub
    • Journal of the Korea Concrete Institute
    • /
    • v.21 no.4
    • /
    • pp.531-537
    • /
    • 2009
  • In this study alkali reactivity of crushed stone was conducted according to the ASTM C 227 that is traditional mortar bar test, and C 1260 that is accelerated mortar bar test method. The morphology and chemical composition of products formed in mortar bar, 3 years after the mortar bar tests had been performed, were examined using scanning electron microscopy (SEM) with secondary electron imaging (SEI) and electron probe microanalysis (EPMA) with backscattered electron imaging (BSEI). The crushed stone used in this study was not identified as being reactive by ASTM C 227. However, mortar bars exceeded the limit for deleterious expansion in accelerated mortar bar test used KOH solution. The result of SEM (SEI) analysis, after the ASTM C 227 mortar bar test, confirmed that there were no reactive products and evidence of reaction between aggregate particles and cement paste. However, mortar bars exposed to alkali solution (KOH) indicated that crystallized products having rosette morphology were observed in the interior wall of pores. EPMA results of mortar bar by ASTM C 227 indicated that white dots were observed on the surface of particles and these products were identified as Al-ASR gels. It can be considered that the mortar bar by ASTM C 227 started to appear sign of alkali-silica reaction in normal condition. EPMA results of the mortar bar by ASTM C 1260 showed the gel accumulated in the pores and diffused in to the cement matrix through cracks, and gel in the pores were found to be richer in calcium compared to gel in cracks within aggregate particles. In this experimental study, damages to mortar bars due to alkali-silica reaction (ASR) were observed. Due to the increasing needs of crushed stones, it is considered that specifications and guidelines to prevent ASR in new concrete should be developed.

Study on the Effect of Contact Angles of Elastic Rubber Impression Materials on the Surface of Working Cast (탄성 고무인상재의 접촉각이 작업모형 표면에 미치는 영향)

  • Kim, Joo-Won
    • Journal of dental hygiene science
    • /
    • v.10 no.3
    • /
    • pp.177-183
    • /
    • 2010
  • This study was begun to search effect of contact angles of elastic rubber impression materials on the surface of working cast. Of elastic rubber impression materials with a Type III consistency, such as polysulfide, polyether and addition silicone, we selected one and then measured the contact angle after dripping a distilled water 3.3ml. Then, after pouring a dental anhydrite in three types of impression materials, we prepared a working cast and then examined its surface. Contact angle was measured using a full automatic contact angle measuring system (DM-700, KYOWA, Japan), and the surface of working cast was observed using a field emission scanning electron microscope (JSM-6700F, JEOL Ltd., JAPAN). The following results were obtained: 1) $Mean{\pm}SD$ (SD: standard deviation) of the initial contact angles were $91.3{\pm}20.5^{\circ}$ in the addition silicone materials, $90.0{\pm}2.2^{\circ}$ in the polyethers and $101.5{\pm}2.3^{\circ}$ in the polysulfides. These results indicate that mean values were similar but standard deviations of the three materials showed a great discrepancy. 2) As the time elapsed, addition silicone materials were found to have a contact angle decreased abruptly as compared with the remaining two types. That is, the initial contact angle was $91.3^{\circ}$ and it was abruptly decreased to $29.4^{\circ}$ after 25 seconds. 3) In the polyethers, the initial contact angle was $101.5^{\circ}$ and it was decreased to $90.7^{\circ}$ after 25 seconds. In the polysulfides, however, the initial contact angle was $90.0^{\circ}$ and it was $84.2^{\circ}$ after 25 seconds. This showed almost no changes in the initial contact angles. Moreover, its magnitude was greater than that seen in additional silicones. 4) There were significant differences in the contact angles between the three types of elastic rubber impression materials as the time elapsed (p<0.001). On an observation on the surface of working cast, addition silicone materials were found to have the most dense surface. This was followed by polysulfides and polyethers in a descending order.

Preparation of Na-X and Na-A Zeolites from Coal Fly Ash in a Thermoelectric Power Plant and Comparison of the Adsorption Characteristics for Cu(II) with a Commercial Zeolite (화력발전소 석탄비산재를 이용한 Na-X와 Na-A 제올라이트 제조 및 상업용 제올라이트와의 Cu(II) 흡착 특성 비교)

  • Choi, Yu-Lim;Angaru, Ganesh Kumar Reddy;Kim, Dong-Su;Ahn, Hye-Young;Kim, Dae-Ho;Choi, Chi-Dong;Reddy, Kodoru Janardhan;Yang, Jae-Kyu;Chang, Yoon-Young
    • Applied Chemistry for Engineering
    • /
    • v.30 no.6
    • /
    • pp.749-756
    • /
    • 2019
  • Na-X and Na-A zeolites that give high adsorption capacity for heavy metals in an aqueous system were synthesized from the coal fly ash obtained from a thermoelectric power plant using a fusion method. The characteristics and Cu(II) adsorption capacity of the synthetic zeolites were also compared to those of using a commercial zeolite. For the selection of optimum conditions of zeolite synthesis, the effects of major parameters in the fusion method such as a dosage ratio of NaOH, aging time, hydrothermal reaction time, and also the dosage ratio of NaAlO2 (Na-A) on the characteristics and Cu(II) adsorption capacity of the synthetic zeolites were studied. For the analysis of characteristics of the synthetic zeolites, X-ray diffraction (XRD), cation exchange capacity (CEC), Brunaue-Emmett-Teller (BET) and scanning electron microscopy (SEM) were used. The optimum conditions for the synthesis of zeolites with a high adsorption capacity for cationic heavy metals including Cu(II) were the aging time of 6 h, hydrothermal reaction time of 6 h and NaOH and NaAlO2 dosage ratio of 1.5 and 0.5 (Na-A), respectively. According to the Langmuir isotherm test, maximum Cu(II) adsorption capacities of the synthetic and commercial Na-X and Na-A zeolites were found to be 90.1, 105.26, 102.05, and 109.89 mg/g, respectively. This indicates that the adsorption capacity of synthetic zeolites was comparable to commercial ones. The results of this study also suggest that the coal fly ash can be potentially used as a raw material for the zeolite synthesis.