• Title/Summary/Keyword: scanner

Search Result 2,060, Processing Time 0.024 seconds

Application of 3-D Laser Scanner for the Measurement of Slope Displacement (사면 변형 측정을 위한 3차원 레이저 스캐너의 적용)

  • Oh, Seok-Hoon;Suh, Baek-Soo
    • Journal of the Korean earth science society
    • /
    • v.31 no.6
    • /
    • pp.555-562
    • /
    • 2010
  • Three-dimensional laser scanner was used to accurately measure any possible strain on a slope under pertaining stress with the time difference of 7 months. The laser scanner has the ability to measure the 3-D coordinate of a target point by calculating the travel time of laser beam between the laser device and the target point, and has been proved to be effective for analysis of the displacement of slopes or large construction. The scanning data measured with time difference were analyzed to find any strain by approaches of plane angle change, curvature variation, twist of frame, displacement of merging point, etc. From the analysis, some weak points showing heavily distorted shape were detected, which was used to design the reinforcement.

Measurement of Particle Deposition Velocity toward a Horizontal Semiconductor Wafer Using a Wafer Surface Scanner (Wafer Surface Scanner를 이용한 반도체 웨이퍼상의 입자 침착속도의 측정)

  • Bae, G.N.;Park, S.O.;Lee, C.S.;Myong, H.K.;Shin, H.T.
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.5 no.2
    • /
    • pp.130-140
    • /
    • 1993
  • Average particle deposition velocity toward a horizontal semiconductor wafer in vertical airflow is measured by a wafer surface scanner(PMS SAS-3600). Use of wafer surface scanner requires very short exposure time normally ranging from 10 to 30 minutes, and hence makes repetition of experiment much easier. Polystyrene latex (PSL) spheres of diameter between 0.2 and $1.0{\mu}m$ are used. The present range of particle sizes is very important in controlling particle deposition on a wafer surface in industrial applications. For the present experiment, convection, diffusion, and sedimentation comprise important agents for deposition mechanisms. To investigate confidence interval of experimental data, mean and standard deviation of average deposition velocities are obtained from more than ten data set for each PSL sphere size. It is found that the distribution of mean of average deposition velocities from the measurement agrees well with the predictions of Liu and Ahn(1987) and Emi et al.(1989).

  • PDF

Vulnerability Analysis using the Web Vulnerability Scanner (Web Vulnerability Scanner를 이용한 취약성 분석)

  • Jang, Hee-Seon
    • Convergence Security Journal
    • /
    • v.12 no.4
    • /
    • pp.71-76
    • /
    • 2012
  • As the use of Mashups, web3.0, JavaScript and AJAX(Asynchronous JavaScript XML) widely increases, the new security threats for web vulnerability also increases when the web application services are provided. In order to previously diagnose the vulnerability and prepare the threats, in this paper, the classification of security threats and requirements are presented, and the web vulnerability is analyzed for the domestic web sites using WVS(Web Vulnerability Scanner) automatic evaluation tool. From the results of vulnerability such as XSS(Cross Site Scripting) and SQL Injection, the total alerts are distributed from 0 to 31,177, mean of 411, and standard deviation of 2,563. The results also show that the web sites of 22.5% for total web sites has web vulnerability, and the previous defenses for the security threats are required.

Comparative analysis on digital models obtained by white light and blue LED optical scanners (백색광과 청색 LED 방식의 광학스캐너로 채득된 디지털 모형의 비교분석)

  • Choi, Seog-Soon;Kim, Jae-Hong;Kim, Ji-Hwan
    • Journal of Technologic Dentistry
    • /
    • v.36 no.1
    • /
    • pp.17-23
    • /
    • 2014
  • Purpose: The purpose of this study was to analyze and compare the relative accuracy of digitized stone models of lower full arch, using two different scanning system. Methods: Replica stone models(N=20) were produced from lower arch acrylic model. Twenty digital models were made with the white light and blue LED($Medit^{(R)}$, Korea) scanner. Two-dimensional distance between the landmarks were measured on the Delcam $CopyCAD^{(R)}$(Delcam plc, UK). Independent samples t-test was applied for comparison of the groups. All statistical analyses were performed using the SPSS software package(Statistical Package for Social Sciences for Windows, version 12.0). Results: The absolute disagreement between measurements made directly on the two different scanner-based dental digital models was 0.02~0.04mm, and was not statistically significant(P>0.05). Conclusion: The precision of the blue LED optical scanner was comparable with the digitization device, and relative accuracy was similar. However, there still is room for improvement and further standardization of dental CAD technologies.

Test-Bed Establishment Scheme for Terrestrial Laser Scanner' Performance Evaluation (지상레이저스캐너 성능평가를 위한 테스트베드 구축 방안)

  • Lee, In-Su;Tcha, Dek-Ki;Kim, Su-Jeong;Kim, Jin
    • Spatial Information Research
    • /
    • v.17 no.1
    • /
    • pp.39-49
    • /
    • 2009
  • 3D terrestrial laser scanners record high precision three-dimensional coordinates of numerous points on an object surface in a short period of time, and is applied to a wide variety of fields including geodesy, and civil engineering, archaeology and architecture, and emergency service and defence, etc. However, most of terrestrial laser scanner utilized in homeland, were imported from foreign country, and also was not authorized formally as the surveying instrument. Therefore, standard test facility to calibrate and perform its evaluation in order to utilize it in a variety of fields is required. This study deals with the test facility of foreign countries for terrestrial laser scanner and suggest the establishment scheme of domestic test facility.

  • PDF

A study on Common Errors in Digital Impressions: (An Example of CEREC$^{(R)}$ AC) (디지털 인상 채득 시 흔히 발생하는 오류에 관한 연구 - CEREC$^{(R)}$ AC의 사례 중심으로 -)

  • Kim, Jae-Hong;Kim, Ji-Hwan;Kim, Hae-Young
    • Journal of Technologic Dentistry
    • /
    • v.33 no.3
    • /
    • pp.211-218
    • /
    • 2011
  • Purpose: The purpose of the study was a quantitative evaluation of common errors in digital impression procedure using CEREC$^{(R)}$ AC system. Methods: Two-hundreds digital impression data comprising 174 inlays, 26 onlays by CEREC$^{(R)}$ AC in-office CAD/CAM system were obtained from a dental clinic. One evaluator assessed errors of the digital impression data and divided into five categories of errors: inappropriate scanner positioning (ISP), improper handling with a scanner (IHS), irregular powder arrangement (IPA), improper cavity preparation (ICP), and insufficient scanned data (ISD). Results: The most common errors were IPA(21%), and ISP and ISD were followed by 17% respectively. IHS was found in 14.5% of all digital impression data. ICP comprising only 6.5% was the rarest. Conclusion: Most errors were due to inaccurate manipulation with an intraoral scanner or improper cavity preparation for scanning. A deliberate manipulation to prevent common errors mentioned may deliver an optimal result in the digital impression procedure.

Characterization of Microfluidic Channels using DVD Pick-up Fluorescent Scanner (광 픽업 방식 형광스캐너를 이용한 미소유체 특성 분석)

  • Yim, Vit;Kim, Jae-Hyun;Lee, Seung-Yop;Park, Jung-Yul
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.32 no.12
    • /
    • pp.1102-1106
    • /
    • 2008
  • Microfluidics deals with the behavior, precise control and manipulation of fluids at a micro scale. It has become increasingly prevalent in various applications such as biomedical applications (diagnostics, therapeutics, and cell/tissue engineering), inkjet head, and fuel cells etc. The issue of inspection and characterization of microfluidics has emerged as a major consideration in design, fabrication, and detection of microfluidic devices. In this paper, we characterize a diffusion based mixing in Y-microchannel using a fluorescent optical scanner based on a DVD pick-up module, which is widely used in optical storages. Using fluorescent dye, we measure the fluorescent intensity that represents the mixing patterns in Y-microchannel. We also compare these experimental results with computational fluid dynamics (CFD) simulation ones. It is shown that the proposed optical scanner can be used as an alternative measurement system with high performance and cost-effectiveness, compared to conventional optical tools such as epifluorescent microscopes using high resolution CCD camera and confocal microscopes with photomultiplier (PMT) detectors.

The Method of Measuring Surface Area by Image Processing -With a Focus on the Comparison between Theory of Measure & Method of Measurement- (이미지 프로세싱 기법을 이용한 체표면적 측정법 -측정 원리와 측정법간의 비교를 중심으로-)

  • 최은주;권영숙
    • Journal of the Korean Society of Clothing and Textiles
    • /
    • v.19 no.2
    • /
    • pp.287-296
    • /
    • 1995
  • measuring surface area errors can be brought about with different measuring people. This study aims at eliminating such errors in measurement. With measures by 3 people whose experience varies from person to person, the existing area measuring method using a planimeter and two other methods which use a computer (one using a digitizer and the other using a scanner) have been analyzed and compared. Three methods have not shown a meaningful difference in respect to the value" of area and two methods other than the one using a scanner have shown a meaningful difference among 3 measuring people. Therefore, we propose the method using a scanner by image processing should be a more improved one for area measuring. The arguments for that are as fllows. 1. The operation for measurement is simple and it has a high degree of accuracy with few errors. 2. Because different measuring people cause few errors the operation started by one person can be handed over to anyone else and the operation dosen't require previous skill. 3. Once image file is saved, the operation can be performed on several computers at the same time with seperate part on each computer. 4. Three methods have needed nearly the same length of time, but time for the method using a scanner can be reduced on computers with a higher capacity.th a higher capacity.

  • PDF

Study on Application of Reverse Engineering by Generation of the Free-Form Surface (자유 곡면 생성을 통한 역공학 적용에 관한 연구)

  • Hur, Sung-Min;Choi, Jae-Won;Lee, Seok-Hee
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.18 no.10
    • /
    • pp.168-177
    • /
    • 2001
  • Reverse engineering has been widely used for the shape reconstruction of an object without CAD data and the measurement of clay or wood models fur the development of new products. To generate a surface from measured points by a laser scanner, typical steps include the scanning of a clay or wood model, the generation of compatible input curves, the generation of a surface and manufacturing data like G code or STL file. A laser scanner has a great potential to get geometrical data of a model for its frost measuring speed and higher precision. The data from a laser scanner are composed of many line stripes of points including small spikes and noise. A new approach using automated surface generating algorithm is introduced to deal with problems during reverse engineering process. And the input data and the generated surface are represented in IGES format, thus can be supplied to other CAD/CAM software without any data manipulation.

  • PDF

The Study of Pain-Increased Factors on Cervical and Shoulder Pain by 3 Dimensional Moire Scanner (3차원 체형 측정기를 통한 경.견부 통증요인 분석)

  • Yang, Hoe-Song;Heo, Ja-Eun;Kim, Bo-Young;Seo, Dong-Yong;An, Chang-Heon;Yang, Hun-Kyung;Jeong, Chan-Ju;Lee, Hyoung-Soo
    • Journal of Korean Physical Therapy Science
    • /
    • v.12 no.3
    • /
    • pp.27-34
    • /
    • 2005
  • The purpose of this study is to find out factors(shoulder level, acromion-occipital length, spine alignment, spine-scapula inferior angle length) of pain of neck & shoulder by 3 Dimensional Moire Scanner. 50 female student s aged 20 to 25 years old participated who lived in Sun-cheon si Jeonnam. They were examined with three measurement methods(Visual Analogue Scale : VAS, Algometer, 3 Dimensional Moire Scanner(IBS-2000). According to the results of multiple regression analysis. 1) There was a significant difference with shoulder level and spine-scapula inferior angle based on VAS. 2) There was a significant difference with shoulder level based of Algometer measurement value in Rhomboid muscles.

  • PDF