• Title/Summary/Keyword: scan line

Search Result 471, Processing Time 0.025 seconds

MTF measuring method of TDI camera electronics

  • Kim, Young-Sun;Kong, Jong-Pil;Heo, Haeng-Pal;Park, Jong-Euk;Yong, Sang-Soon;Choi, Hae-Jin
    • Proceedings of the KSRS Conference
    • /
    • 2007.10a
    • /
    • pp.540-543
    • /
    • 2007
  • The modulation transfer function (MTF) in a camera system is a measurement of how well the system will faithfully reproduce the original scene. The electro-optical camera system consists of optics, an array of pixels, and an electronics which is related to the image signal chain. The system MTF can be cascaded with each element's MTF in the frequency domain. That is to say, the electronics MTF including the detector MTF can be recalculated easily by the acquired system MTF if the well-known test optics is used in the measuring process. A Time-Delay and Integration (TDI) detector can make a signal increase by taking multiple exposures of the same object and adding them. It can be considered the various methods to measure the MTF of the TDI camera system. This paper shows the actual and practical MTF measuring methods for the detector and electronics in the TDI camera. The several methods are described according to the scan direction as well as the TDI stages such as the single line mode and the multiple-lines mode. The measuring is performed in the in the static condition or dynamic condition to get the point spread function (PSF) or the line spread function (LSF). Especially, the dynamic test bench is used to simulate on track velocity to synchronize with TDI read out frequency for the dynamic movement.

  • PDF

Differentiation of Beef and Fish Meals in Animal Feeds Using Chemometric Analytic Models

  • Yang, Chun-Chieh;Garrido-Novell, Cristobal;Perez-Marin, Dolores;Guerrero-Ginel, Jose E.;Garrido-Varo, Ana;Cho, Hyunjeong;Kim, Moon S.
    • Journal of Biosystems Engineering
    • /
    • v.40 no.2
    • /
    • pp.153-158
    • /
    • 2015
  • Purpose: The research presented in this paper applied the chemometric analysis to the near-infrared spectral data from line-scanned hyperspectral images of beef and fish meals in animal feeds. The chemometric statistical models were developed to distinguish beef meals from fish ones. Methods: The meal samples of 40 fish meals and 15 beef meals were line-scanned to obtain hyperspectral images. The spectral data were retrieved from each of 3600 pixels in the Region of Interest (ROI) of every sample image. The wavebands spanning 969 nm to 1551 nm (across 176 spectral bands) were selected for chemometric analysis. The partial least squares regression (PLSR) and the principal component analysis (PCA) methods of the chemometric analysis were applied to the model development. The purpose of the models was to correctly classify as many beef pixels as possible while misclassified fish pixels in an acceptable amount. Results: The results showed that the success classification rates were 97.9% for beef samples and 99.4% for fish samples by the PLSR model, and 85.1% for beef samples and 88.2% for fish samples by the PCA model. Conclusion: The chemometric analysis-based PLSR and PCA models for the hyperspectral image analysis could differentiate beef meals from fish ones in animal feeds.

Development of Skirt Pattern for the Middle Aged Women of Obese using the 3-Dimension Technology (3차원을 이용한 중년 비만 여성용 스커트 설계 방법론 연구)

  • Sohn, Boo-Hyun;Kim, So-Young
    • The Research Journal of the Costume Culture
    • /
    • v.16 no.5
    • /
    • pp.852-862
    • /
    • 2008
  • The purpose of this paper is to find how to do the width of skirt and the girth of the waist in the adequate pattern making for the obese women's skirt. Appearance test of the five experimental skirts was evaluated by the four experts in clothing construction. At the same time, 3D clothing air volume was observed for the five types of experimental skirt with different size specifications. The results from the appearance test were as follows; when the width of skirt pattern is set for(the shell girth/2), it was suggested w/4+1(front), w/4(back) for girth of the waist. On one hand, in case of (the shell girth of front)/2+(the shell girth of back)/2, it was suggested(the waist girth of front)/2 and(waist girth of back)/2 for obese women's skirt with the best appearance. As results, it was found that the width of skirt pattern for the obese women should be the greatest shell girth instead of hip girth. In the case of the hip girth, the amount of ease on hip was suggested 6cm. It was found that pattern with the wrinkle of ease was full of the gaps between body and skirt in 3D clothing air volume. In spreading out to 2D flat pattern from 3D scan data, when the width of skirt pattern was set for(the shell girth of front)/2+(the shell girth of back)/2, it was suggested(the waist girth of front/2)+(the waist girth of back/2) than the shell girth/2 in girth of the waist for the best appearance. And the conversion of 3D scan data into 2D flat pattern in curve shape of crosswise had to spread out of the plane in straight line. The obese women's clothing should be manufactured with systematical consideration of the diversity and scarcity of the obese women's body shape.

  • PDF

Low-power VLSI Architecture Design for Image Scaler and Coefficients Optimization (영상 스케일러의 저전력 VLSI 구조 설계 및 계수 최적화)

  • Han, Jae-Young;Lee, Seong-Won
    • Journal of the Institute of Electronics Engineers of Korea SD
    • /
    • v.47 no.6
    • /
    • pp.22-34
    • /
    • 2010
  • Existing image scalers generally adopt simple interpolation methods such as bilinear method to take cost-benefit, or highly complex architectures to achieve high quality resulting images. However, demands for a low power, low cost, and high performance image scaler become more important because of emerging high quality mobile contents. In this paper we propose the novel low power hardware architecture for a high quality raster scan image scaler. The proposed scaler architecture enhances the existing cubic interpolation look-up table architecture by reducing and optimizing memory access and hardware components. The input data buffer of existing image scaler is replaced with line memories to reduce the number of memory access that is critical to power consumption. The cubic interpolation formula used in existing look-up table architecture is also rearranged to reduce the number of the multipliers and look-up table size. Finally we analyze the optimized parameter sets of look-up table, which is a trade-off between quality of result image and hardware size.

Pitch Measurement of One-dimensional Gratings Using a Metrological Atomic Force Microscope and Uncertainty Evaluation (미터 소급성을 갖는 원자간력 현미경을 이용한 1차원 격자 피치 측정과 불확도 평가)

  • Kim Jong-Ahn;Kim Jae Wan;Park Byong Chon;Eom Tae Bong;Kang Chu-Shik
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.22 no.4
    • /
    • pp.84-91
    • /
    • 2005
  • We measured the pitch of one-dimensional (ID) grating specimens using a metrological atomic force microscope (M-AFM). The ID grating specimens a.e often used as a magnification standard in nano-metrology, such as scanning probe microscopy (SPM) and scanning electron microscopy (SEM). Thus, we need to certify the pitch of grating specimens fur the meter-traceability in nano-metrology. To this end, an M-AFM was setup at KRISS. The M-AFM consists of a commercial AFM head module, a two-axis flexure hinge type nanoscanner with built-in capacitive sensors, and a two-axis heterodyne interferometer to establish the meter-traceability directly. Two kinds of ID grating specimens, each with the nominal pitch of 288 nm and 700 nm, were measured. The uncertainty in pitch measurement was evaluated according to Guide to the Expression of Uncertainty in Measurement. The pitch was calculated from 9 line scan profiles obtained at different positions with 100 ㎛ scan range. The expanded uncertainties (k = 2) in pitch measurement were 0.10 nm and 0.30 nm for the specimens with the nominal pitch of 288 nm and 700 nm. The measured pitch values were compared with those obtained using an optical diffractometer, and agreed within the range of the expanded uncertainty of pitch measurement. We also discussed the effect of averaging in the measurement of mean pitch using M-AFM and main components of uncertainty.

Clinical Guideline for Childhood Urinary Tract Infection (Second Revision)

  • Lee, Seung Joo
    • Childhood Kidney Diseases
    • /
    • v.19 no.2
    • /
    • pp.56-64
    • /
    • 2015
  • To revise the clinical guideline for childhood urinary tract infections (UTIs) of the Korean Society of Pediatric Nephrology (2007), the recently updated guidelines and new data were reviewed. The major revisions are as follows. In diagnosis, the criterion for a positive culture of the catheterized or suprapubic aspirated urine is reduced to 50,000 colony forming uits (CFUs)/mL from 100,000 CFU/mL. Diagnosis is more confirmatory if the urinalysis is abnormal. In treating febrile UTI and pyelonephritis, oral antibiotics is considered to be as effective as parenteral antibiotics. In urologic imaging studies, the traditional aggressive approach to find primary vesicoureteral reflux (VUR) and renal scar is shifted to the targeted restrictive approach. A voiding cystourethrography is not routinely recommended and is indicated only in atypical or complex clinical conditions, abnormal ultrasonography and recurrent UTIs. $^{99m}Tc$-DMSA renal scan is valuable in diagnosing pyelonephritis in children with negative culture or normal RBUS. Although it is not routinely recommended, normal scan can safely avoid VCUG. In prevention, a more natural approach is preferred. Antimicrobial prophylaxis is not supported any more even in children with VUR. Topical steroid (2-4 weeks) to non-retractile physiologic phimosis or labial adhesion is a reasonable first-line treatment. Urogenital hygiene is important and must be adequately performed. Breast milk, probiotics and cranberries are dietary factors to prevent UTIs. Voiding dysfunction and constipation should be properly treated and prevented by initiating toilet training at an appropriate age (18-24 months). The follow-up urine test on subsequent unexplained febrile illness is strongly recommended. Changes of this revision is not exclusive and appropriate variation still may be accepted.

Frequency Division Concurrent Sensing Method for High-Speed Detection of Large Touch Screens (대형 터치스크린의 고속감지를 위한 주파수분할 동시센싱 기법)

  • Jang, Un-Yong;Kim, HyungWon
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.19 no.4
    • /
    • pp.895-902
    • /
    • 2015
  • This paper presents a high-speed sensing and noise cancellation technique for large touch screens, which is called FDCS (Frequency Division Concurrent Sensing). Most conventional touch screen detection methods apply excitation pulses sequentially and analyze the sensing signals sequentially, and so are often unacceptably slow for large touch screens. The proposed technique applies sinusoidal signals of orthogonal frequencies simultaneously to all drive lines, and analyzes the signals from each sense line in frequency domain. Its parallel driving allows high speed detection even for a very large touch screens. It enhances the sensing SNR (Signal to Noise Ratio) by introducing a frequency domain noise filtering scheme. We also propose a pre-distortion equalizer, which compensates the drive signals using the inverse transfer function of touch screen panel to further enhance the sensing SNR. Experimental results with a 23" large touch screen show that the proposed technique enhances the frame scan rate by 273% and an SNR by 43dB compared with a conventional scheme.

Classification of Upper Body Somatotypes according to the Age Group : Using 3D-Body Scan Data

  • Na, Hyun-Shin
    • International Journal of Costume and Fashion
    • /
    • v.5 no.1
    • /
    • pp.1-13
    • /
    • 2005
  • Two hundreds of female aged 19 years old and up were recruited to evaluate the postural changes and bilateral variation of asymmetry over age. To find out the differences among the age group, subjects were classified into 5 groups, early young age(19-29), late young age(30-39), early middle age(40-49), late middle age(50-59), and old age(60-). 35 body measurements were taken by the 3-D body scanner which allowed us to take measurements which cannot be measured using traditional methods, including the shape of a cross section, slice area surface are, and volume. Bilateral variations were observed as a function of age; Depth of scapular point level, scapular point to center back, and blade angle. Postural change of anterior cervical angle, upper anterior thoracic angle, upper posterior thoracic angle, posterior cervical angle, and center back/center front ratio were also exhibited. In each measurements, subjects were classified into normal, and abnormal group. Percentiles of abnormal in shoulder line angle, blade angle, neck point $\∼$ acromial point $\∼$ scapular point, posterior cervical angle, and upper posterior thoracic angle were increased over age group. The upper body of lateral view was classified into 3 types of posture based on the previous research; straight, erect(leaning back), and stooped(bent forward). The percentiles of subjects who have straight postures were decreased as a function of age, but those of stooped postures were increased. Subjects who have erect postures did not so. The stooped posture group shows the big cervical fossa angle, anterior cervical angle, posterior cervical angle, upper posterior thoracic angle, and the small upper anterior thoracic angle comparing to the straight and erect posture group. These results could be apply for clothing construction reflecting the changes in back, shoulder, neck, and the bilateral asymmetry according to the target age group.

A Case of Liposclerosing Granuloma Arising from Lower Eyelid (아래 눈꺼풀에서 발생한 지방 경화성 육아종의 치험례)

  • Park, Bo Young;Kang, So Ra
    • Archives of Plastic Surgery
    • /
    • v.35 no.5
    • /
    • pp.603-606
    • /
    • 2008
  • Purpose: Sclerosing lipogranuloma is an unusal benign condition of the genitalia following injections into the genitalia with exogenous paraffin or mineral oil. A few cases have been reported in which sclerosing lipogranuloma of the lid was caused by paraffin-containing ointment plugs after the endonasal sinus surgery. A 52-year-old man presented with a painless hard mass of the right lower lid after the MRI scan at the Ophthalmology department. Nine months before, he had undergone right maxilla sinus surgery through the oral incision. And he was also gotten nasal packing with Vaseline gauze after the surgery. Methods: The round shaped two masses in the Right lower lid were approximately $1.0{\times}1.0cm$ in size. There were no size or color change, bleeding and ulceration. The MRI scan showed a suspicious part of an abscess of benign tumor. Also, He was planned cyst remove through the endonasal surgery due to the mucoid cyst in the right maxillary sinus in the ENT dept. Under the general anesthesia, the patient underwent surgical excision through a subcilliary incision with endonasal sinus surgery. The masses were in deep subcutaneous orbital fat with no connection with right maxillary sinus. Results: The masses were excised $2.1{\times}0.7cm$ in size including surrounding necrotic fatty tissue. Histopathological diagnosis was 'sclerosing lipogranuloma' due to paraffin or similar substance with fat necrosis and cystic change. This tissue was positive in PAS, S-100, CD68 reaction. Conclusion: It is extremely rare to find a granulomatous orbital lesion arising to a endonasal surgery. In conclusion, if sclerosing lipogranuloma is suspected excisional biopsy should be undertaken. Surgery should be reserved for recurrent or refractory cases when steroids have failed as first-line treatment at the 6-month follow-up examination, There was no complication or recurrence.

Characteristics of nanolithograpy process on polymer thin-film using near-field scanning optical microscope with a He-Cd laser (He-Cd 레이저와 근접장현미경을 이용한 폴리머박막 나노리소그라피 공정의 특성분석)

  • Kwon S. J.;Kim P. K.;Chun C. M.;Kim D. Y.;Chang W. S.;Jeong S. H.
    • Laser Solutions
    • /
    • v.7 no.3
    • /
    • pp.37-46
    • /
    • 2004
  • The shape and size variations of the nanopatterns produced on a polymer film using a near-field scanning optical microscope(NSOM) are investigated with respect to the process variables. A cantilever type nanoprobe having a 100nm aperture at the apex of the pyramidal tip is used with the NSOM and a He-Cd laser at a wavelength of 442nm as the illumination source. Patterning characteristics are examined for different laser beam power at the entrance side of the aperture($P_{in}$), scan speed of the piezo stage(V), repeated scanning over the same pattern, and operation modes of the NSOM(DC and AC modes). The pattern size remained almost the same for equal linear energy density. Pattern size decreased for lower laser beam power and greater scan speed, leading to a minimum pattern width of around 50nm at $P_{in}=1.2{\mu}W\;and\;V=12{\mu}m/s$. Direct writing of an arbitrary pattern with a line width of about 150nm was demonstrated to verify the feasibility of this technique for nanomask fabrication. Application on high-density data storage is discussed.

  • PDF