• Title/Summary/Keyword: sample injection method

Search Result 168, Processing Time 0.027 seconds

A Study on Carrier Injection and Trapping by the High Field for MAS (Al-Al2O3-Si(n)) Structure ($Al-Al_2O_3-Si$(N형)의 MAS 구조에 있어서 고전계에 의한 Carrier 주인과 트?에 관한 연구)

  • 이영희;박성희
    • The Transactions of the Korean Institute of Electrical Engineers
    • /
    • v.35 no.10
    • /
    • pp.465-472
    • /
    • 1986
  • The present study was carried out to investigate the mechanism which control the voltage instability and the breakdown of CVD Al2O3 on Si substrates. Our sample were metal-Al2O3-Oi Capacitors with both Al and Au field plates. Electron injection and trapping, with resultant positive flatband voltage shift, occur at fields as low as 1-2[MV/cm.] We developed an approximate method for computing the location of the centroid of the trapped electrons. Our results indicate that the electrons are trapped near the injecting interface, at least for fields less than about 5[MV/cm ] Because of continued charging, a true steady state is probably never reached, and the only unique I-V curve is the one obtained initially, when the traps are empty. We measured this I-V curve for both polarities of applied voltage, using a fresh sample for each point. The observed current densities are much larger than those obtained in thermally grawn SiO2.

  • PDF

A study on method for reducing haze defects of head lamp for automobiles (자동차용 헤드램프의 플라스틱 소재 Haze 저감 방법에 관한 연구)

  • Lee, Seung-Wook;Lee, Chun-Kyu
    • Design & Manufacturing
    • /
    • v.15 no.4
    • /
    • pp.32-36
    • /
    • 2021
  • In this study, the cause of the decrease in transmittance of the outer lens among the causes of the decrease in the amount of light in the automobile headlamp was identified, and the improvement method was selected to determine the effect. The causes of defects that lower the transmittance of the outer lens are divided into a moisture problem and a haze problem. The moisture problem is caused by the temperature difference between the inside and the outside of the head lamp, and the haze problem occurs when the heat inside the head lamp evaporates the haze component contained in the plastic material and attaches it to the outer lens. In order to improve the haze problem that occurs in plastic raw materials, the structures of the bulb light source type headlamp and the LED chip light source type headlamp were analyzed. Among them, the housing material of the LED chip light source type headlamp, which is structurally prone to haze gas, was selected as the test target. In the mass-production injection process of the housing, the drying process was selected as a method to minimize haze gas without adding a separate production process. After extracting a sample every drying time at a constant drying temperature, the sample was put into a haze tester and the residual amount of haze gas was measured. As a result, it was confirmed that the residual amount of Haze gas in the material decreased as the drying time increased.

Optimized Design of Dioxin Analysis for Water Sample

  • Choi, Jaewon;Lee, Jaehee;Kim, Kyoungsim;Kim, Sunheong;Bae, Kyunghee
    • Journal of Korean Society on Water Environment
    • /
    • v.21 no.3
    • /
    • pp.219-229
    • /
    • 2005
  • The analytical methods for dioxins in water sample from wastewater to tap water were reviewed. For extraction method, liquid-liquid extraction (LLE) has been widely used, however, this process needs too much time and man power. New approach including solid phase extraction (SPE) is now applicable to large volume of water sample with high extraction efficiency. Column clean up in classical analytical methods were very complex and time consuming procedures during decade. Modifications were tried to decrease solvent and reagents volume. Moreover, use of column connection method has been demonstrated in the environmental matrices. Instrumental configurations also have been improved, in which GC/MS/MS with large volume injection approach can analyze picogram levels. Absolute sensitivities of HRMS increased compared to old versions of double focusing sector type mass spectrometers. Based on these analytical evolutions during last 10 years, we tried to optimize the analytical method for dioxins in water sample from sample extraction to instrumental analysis.

Development of an Analytical Method for the Spectrometric Simultaneous Determination of Fe2+ and Fe3+ Ions Using a Technique of Flow Injection Analysis (흐름주입분석기법을 이용한 Fe2+ 이온과 Fe3+이온의 광학적 동시정량을 위한 분석기법의 개발)

  • Hwang, Hun;Kim, Jin Ho
    • Journal of the Korean Chemical Society
    • /
    • v.46 no.5
    • /
    • pp.419-437
    • /
    • 2002
  • An analytical method for the spectrometric simultaneous determination of the individual ions in the mix-tures of $Fe^{2+}$ and $Fe^{2+}$ ions utilizing a technique of flow injection analysis has been developed. The method was based on the oxidation reaction between $Fe^{2+}$ ion and $H_2O_2$ in an acidic medium and the subsequent formation of a red Fe$(SCN)^{3-x}_x$ ion by the complexation reaction between $Fe^{2+}$ ion and $SCN^-$ ion. Unlike the conventional methods which require separate processes for the pre-treatment of the sample solution, the current method uses the same FIA system for the pre-treatment and the analysis of the sample. The detection limit for the determination of $Fe^{2+}$ ion was found to be 6.00${\times}10^{-7}$M.

Determination of Total Chlorine Residuals by Flow Injection Analysis (흐름 주입 분석법에 의한 총 잔류염소의 정량)

  • Choi, Yong Wook
    • Journal of the Korean Chemical Society
    • /
    • v.43 no.4
    • /
    • pp.430-437
    • /
    • 1999
  • The determination of total chlorine residuals in drinking water by flow injection analysis(FIA) with iodometric UV detection was investigated. The pH of the acid stream, the concentration of the iodide ion,the length of the mixing and reaction coils, the injection sample size, and flowrate were optimized as parameters for determining total chlorine residuals by FIA method. lodide was selectively oxidized to iodine by hypochlorite at pH 8.3 Ethylenediamine as masking agent for masking interference ions from the sample was given the best efficency. Calibration curve presented linear range of 0.03-3 mg/L for hypochlorite ion with a correlation coefficient of 0.999 or better. The detection limit was found to be 0.007 mg/L for hypochlorite ion. Under these analytical conditions, total chlorine residuals in several tap water sampled in the city of Jeonju were analyzed.

  • PDF

Frit-Inlet Asymmetrical Flow Field-Flow Fractionation (FI-ARIFF): A Stopless Separation Technique for Macromlecules and Nanopariticles

  • Mun, Myeong Hui
    • Bulletin of the Korean Chemical Society
    • /
    • v.22 no.4
    • /
    • pp.337-348
    • /
    • 2001
  • This article gives an overview of a recently developed channel system, frit-inlet asymmetrical flow field-flow fractionation (FI-AFlFFF), which can be applied for the separation of nanoparticles, proteins, and water soluble polymers. A conventiona l asymmetrical flow FFF channel has been modified into a frit-inlet asymmetrical type by introducing a small inlet frit near the injection point and the system operation of the FI-AFlFFF channel can be made with a great convenience. Since sample components injected into the FI-AFlFFF channel are hydrodynamically relaxed, sample injection and separation processes proceed without interruption of the migration flow. Therefore in FI-AFlFFF, there is no requirement for a valve operation to switch the direction of the migration flow that is normally achieved during the focusing/relaxation process in a conventional asymmetrical channel. In this report, principles of the hydrodynamic relaxation in FI-AFlFFF channel are described with equations to predict the retention time and to calculate the complicated flow variations in the developed channel. The retention and resolving power of FI-AFlFFF system are demonstrated with standard nanospheres and protreins. An attempt to elucidate the capability of FI-AFlFFF system for the separation and size characterization of nanoparticles is made with a fumed silica particle sample. In FI-AFlFFF, field programming can be easily applied to improve separation speed and resolution for a highly retaining component (very large MW) by using flow circulation method. Programmed FI-AFlFFF separations are demonstrated with polystyrene sulfonate standards and pululans and the dynamic separation range of molecular weight is successfully expanded.

Indocyanine green excretion test and changes of plasma enzyme activities in Korean native cattle and dairy cattle (한우 및 유우에서의 indocyanine green 배설시험 및 혈장효소 활성치의 변화)

  • Son, Min-soo;Kim, Cheol-ho;Choi, IL-kwan;Kim, Jin-gu;Hur, Ju-hyeong;Kang, Chung-boo
    • Korean Journal of Veterinary Research
    • /
    • v.32 no.4
    • /
    • pp.677-681
    • /
    • 1992
  • This experiment was carried out to establish a proper method of indocyanine green(ICG) excrection test for a applicable liver function test in three Korean native cattle average weighing about 450kg and dairy cattle parity of 3~5. The results obtained the half life($T^1/_2$), fractional clearance rate(KICG), retention rate and plasma enzyme activities before or after injection of ICG were as follows. 1. The maximum absorbance of ICG in plasma was at 805nm. 2. Average half life and fractional clearance rate following the injection of ICG 0.25mg/kg body weight were $5.53{\pm}1.27$ minute and $0.131{\pm}0.031$/minute in Korean native cattle, $4.55{\pm}0.68$ minute and $0.156{\pm}0.031$/minute in dairy cattle, respectively. The ICG removal rate was exponentially liner for the first 15 minutes after injection both of Korean native cattle and dairy cattle. 3. Average plasma retention rate when 10, 15, 30 minutes after injection was $35.7{\pm}13.9$, $23.2{\pm}7.1$, $10.8{\pm}3.5%$ in Korean native cattle, $26.8{\pm}3.3$, $14.2{\pm}1.2$, $5.5{\pm}2.2%$ in dairy cattle, respectively. 4. Plasma enzyme activities(AST, ALT, r-GTP) were no variation among the before, during and after injection of ICG. From these results, ICG excretion test to cattle is applicable to evaluation of liver funtion in both clinical and research, and adopted the 15 minutes plasma sample as the sample taken at the ideal time for comparative purposes.

  • PDF

On-line Monitoring of a Glucose Concentration on a Fermentation Process of Wine for an Automatic Control of a Fermentation Process (발효공정 자동제어를 위한 포도주 발효 중 포도당 농도 온라인 측정)

  • Song, Dae-Bin
    • Journal of Biosystems Engineering
    • /
    • v.33 no.4
    • /
    • pp.276-281
    • /
    • 2008
  • A flow injection analysis method (FIA), which analyzes sample conditions after injecting a sample and reagents into a continuous stream, are recognized as the most adequate analyzing method according to the increase of sampling frequency, the decrease of measuring time and the diversity of measuring targets. Specially, the FIA is considered to be used effectively for the control of a fermentation process to produce fermentation food and useful microbial production by activation of a fermentation industry for development of biological materials. In this study, a flow injection analysis sensor unit was developed for on-line monitoring of the fermentation process. The performance was verified by on-line measuring the concentration of glucose of the fermentation process of wine. The glucose concentrations of the samples were measured every 12 hours during the whole fermentation process and compared with those by a HPLC. The concentration relative errors of glucose on the fermentation process of wine showed below 30% within 72 hours and over 50% after the 72 hours. The sensor unit had potential to on-line monitoring of the fermentation process but some problems to overcome for an commercial application.

Optimum design of injection molding cooling system via boundary element method (경계요소법을 이용한 사출성형금형 냉각시스템의 최적설계)

  • Park, Seong-Jin;Kwon, Tai-Hun
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.21 no.11
    • /
    • pp.1773-1785
    • /
    • 1997
  • The cooling stage is the very critical and most time consuming stage of the injection molding process, thus it cleary affects both the productivity and the part quality. Even through there are several commercialized package programs available in the injection molding industry to analyze the cooling performance of the injection molding coling stage, optimization of the cooling system has npt yet been accomplished in the literature due to the difficulty in the sensitivity analysis. However, it would be greatly desirable for the mold cooling system designers to have a computer aided design system for the cooling stage. With this in mind, the present study has successfully developed an interated computer aided design system for the injection molding cooling system. The CAD system utilizes the sensitivity analysis via a Boundary Element Method, which we recently developed, and the well-known CONMIN alforuthm as an optimization technique to minimize a weighted combination (objective function) of the temperature non-uniformity over the part surface and the cooling time related to the productivity with side constranits for the design reality. In the proposed objective function , the weighting parameter between the temperature non-uniiformity abd the cooling time can be adjusted according to user's interest. In this cooling system optimization, various design variable are considered as follows : (i) (design variables related to processing conditions) inlet coolant bulk temperature and volumetric flow rate of each cooling channel, and (ii) (design variables related to mold cooling system design) radius and location of each cooling channel. For this optimum design problem, three different radius and location of each cooling channel. For this optimum design problem, three different strategies are suffested based upon the nature of design variables. Three sample problems were successfully solved to demonstrated the efficiency and the usefulness of the CAD system.

The Determination of Dissolved Total Fe by Flow Injection Analysis in Environmental Samples

  • Kim, Do Hoon;Takeda, Kazuhiko;Sakugawa, Hiroshi;Lee, Jin Sik
    • Analytical Science and Technology
    • /
    • v.14 no.6
    • /
    • pp.510-515
    • /
    • 2001
  • There has been an increasing need for analytical methods of dissolved total iron (tFe) that are highly sensitive, rapid, inexpensive and simple for environmental samples. A sensitive flow injection analysis (FIA) method for determining the concentration of tFe in environmental samples was developed. The proposed method required 10 minutes and only $500{\mu}L$ of sample for and analysis. The standard deviation was 5.0% at $0.5{\mu}gL^{-1}$ (n=6), and the detection limit was $0.075{\mu}gL^{-1}$. The developed method was applied to environmental samples such as tap water, mineral water, rain, snow and cloud water. Since this FIA system was free form interferences of coexisting ions commonly found in samples, sub-${\mu}gL^{-1}$ level of tFe could be easily determined without further preconcentration and separation.

  • PDF