Browse > Article

Optimized Design of Dioxin Analysis for Water Sample  

Choi, Jaewon (International Drinking Water Center, Korea Water Resources Corporation)
Lee, Jaehee (International Drinking Water Center, Korea Water Resources Corporation)
Kim, Kyoungsim (International Drinking Water Center, Korea Water Resources Corporation)
Kim, Sunheong (International Drinking Water Center, Korea Water Resources Corporation)
Bae, Kyunghee (International Drinking Water Center, Korea Water Resources Corporation)
Publication Information
Abstract
The analytical methods for dioxins in water sample from wastewater to tap water were reviewed. For extraction method, liquid-liquid extraction (LLE) has been widely used, however, this process needs too much time and man power. New approach including solid phase extraction (SPE) is now applicable to large volume of water sample with high extraction efficiency. Column clean up in classical analytical methods were very complex and time consuming procedures during decade. Modifications were tried to decrease solvent and reagents volume. Moreover, use of column connection method has been demonstrated in the environmental matrices. Instrumental configurations also have been improved, in which GC/MS/MS with large volume injection approach can analyze picogram levels. Absolute sensitivities of HRMS increased compared to old versions of double focusing sector type mass spectrometers. Based on these analytical evolutions during last 10 years, we tried to optimize the analytical method for dioxins in water sample from sample extraction to instrumental analysis.
Keywords
Dioxin; PCDD/F; Analysis; Toxicity equivalency factor (TEF); Toxic equivalent (TEQ); Tap water;
Citations & Related Records
연도 인용수 순위
  • Reference
1 Addink, R., Govers, H. A. J. and Olie, K., Isomer Distributions of Polychlorinated Dibenzo-p-dioxins/dibenzofurans Formed during de Novo Synthesis on Incinerator Fly Ash, Environ. Sci. Technol., 32, pp. 1888-1893 (1998)   DOI   ScienceOn
2 Environmental Agency and Ministry of Health and Welfare of Japan, Report on Tolerable Daily Intake (TDI) of Dioxin and Related Compounds (1999)
3 Environment Canada, Proposed Reference Method for the Determination of PCDD/PCDF in Pulp and Paper Mill Effluents (1990)
4 Eppe, G., Focant, J. F., Pirard, C. and De Pauw, E., PTVLV- GC/MS/MS as Screening and Complementary Method to HRMS for the Monitoring of Dioxin Levels in Food and Feed, Talanta, 63, pp. 1135-1146 (2004)   DOI   ScienceOn
5 Kim, H. K., Kazui, H., Matsumura, T., Ohno, K., Kamei, T. and Magara, Y., Dioxins in Drinking Water Treatment Process, Organohalogen Compounds, 51, pp. 135-138 (2001)
6 Kitamura, K., Mochizuki, A., Choi, J. W., Takazawa, Y, Hashimoto, S., Ito, H., Fujimine, Y. and Morita, M., Optimization of a Method for Determining Dioxin in Whole Blood Samples Based on Solvent Extraction and Simplified Cleanup, Analyst, 129, pp. 315-322 (2004)   DOI   ScienceOn
7 Korytar, P., Leonards, P. E. G., Danielsson, C., Haglund, P., de Boer, J. and Brinkman, U. A. T., GC x GC Method Development for Analysis of Seventeen 2,3,7,8-substituted Dioxins, Furans and Twelve Dioxin-like PCBs, Organohalogen Compounds, 60, pp. 355-358 (2003)
8 Landin, P., Llompart, M., Lourido, M., Garcia-Jares, C., Carro, N. and Cela, R., Rapid Determination of 2,3,7,8-tetrachlorodibenzo- p-dioxin in Water Samples by using Solid-phase Microextraction followed by Gas Chromatography with Tandem Mass Spectrometry, J AOAC Int., 86, pp. 44-49 (2003)   PUBMED
9 Ezaki, T., Masuzaki, Y., Matsumura, T., Ohashi, M., Ito, H. and Morita, M., Development of Solvent Cut Large Volume (SCLV) Injection Technique with Dual Column Configuration for Rapid and High Sensitive GC-HRMS Analysis, Organohalogen Compounds, 50, pp. 190-193 (2001)
10 Japanese Industrial Standards Committee, Japanese Industrial Standard (JIS K 0312) (1999a)
11 Matsumura, T., Masuzaki, Y., Ezaki, T., Ohashi, M. and Morita, M., Detection of Low Femto Gram DioxinsDevelopment of Switching Solvent Cut Large Volume / Multiple Injection - Cryofocus Trap GC-HRMS, Organohalogen Compounds, 45, pp. 25-28 (2000)
12 Suzuki, T., Murayama, H., Taneoka, Y., Takai, T., Yanaka, K., Shibuya, N., Hashimoto, S. and Ito, H., Simplified Analysis of Dioxins using Disposable Catridge Column Clean-up and GC/ion-storage MS/MS, J Environ. Chem. Abst., pp. 834-835 (2003)
13 Matsukami, H., Hayashi, A., Takasuga, T., Ohi, E. and Senthilkumar, K., Separation Conditions and Percentage Recovery of Dioxin-like PCBs, PCDDs and PCDFs through Power-prep by Fluid Management System, Organohalogen Compounds, 60, pp. 72-75 (2003)
14 Tsutsumi T., Yanagi, T., Nakamura, M., Kono, Y., Uchibe, H., Iida, T., Hori, T., Nakagawa, R., Tobiishi, K., Matsuda, R., Sasaki, K. and Toyoda, M., Update of Daily Intake of PCDDs, PCDFs, and Dioxin-like PCBs from Food in Japan, Chemosphere, 45, pp. 1129-1137 (2001)   DOI   ScienceOn
15 US EPA Office of Water Regulations and Standards, Method 1613 (revision A). Tetra- through Octa-Chlorinated Dioxins and Furans by Isotope Dilution HRGCIHRMS (1990)
16 Kawano, K., Yamamoto, I., Sotomaru, K. and Kobayashi, S., Study of Rapid Cleanup for Dioxin with Two-layer Carbon Silicagel and Automatic Cleanup System, J Environ. Chem. Abst., pp. 352-353 (2003)
17 de Koning, S., Kurano, M., Janssen, H. G. and Brinkman, U. A. T., AT-column, a Novel Concentrating Technique for Large-volume Injections in Gas Chromatography, J Chromatogr A., 1023, pp. 165-174 (2004)   DOI   PUBMED   ScienceOn
18 Kuramochi, H., Ohsako, M., Maeda, K. and Sakai, S., Prediction of Physico-chemical Properties for PCDDs/DFs using the UNIFAC Model with an Alternative Approximation for Group Assignment, Chemosphere, 49, pp. 135-142 (2002).   DOI   ScienceOn
19 Ogura, I., Masunaga, S. and Nakanishi, J., Congener-specific Characterization of PCDDs/PCDFs in Atmospheric Deposition: Comparison of Profiles among Deposition, Source, and Environmental Sink, Chemosphere, 45, pp. 173-183 (2001).   DOI   ScienceOn
20 Ministry of Health and Welfare of Japan, Analytical Manual for Dioxins in Raw and Tap Water (1999)
21 Richter, B. E., Ezzell, J. L., Knowles, D. E., Hoefler, F. A., Mattulat, K. R., Scheutwinkel, M., Waddell, D. S., Gobran, T. and Khurana, V., Extraction of Polychlorinated Dibenzop- dioxins and Polychlorinated Dibenzofurans from Environmental Samples using Accelerated Solvent Extraction (ASE), Chemosphere, 34, pp. 975-987 (1997)   DOI   ScienceOn
22 Patterson, D. G., Barr, J. and Dipietro E. S., Comprehensive Two-dimensional and Fast Single-dimensional GC-HRMS Analysis of Human Serum for PCDDs, PCDFs, cPCBs, Congener PCBs, Persistent and Nonpersistent Pesticides, and PAHs, Organohalogen Compounds, 27, pp. 309-314 (1996).
23 Aozasa, O., Mochizuki, A., Ohta, S., Nakao, T., Miyata, H. and Nomura, T., Optimization of the Purification Method for Dioxin Analysis in Human Serum and Temporal Changes in Background Dioxin Levels in the General Population, Chemosphere, 50, pp. 1157-1165 (2003)   DOI   ScienceOn
24 Van den Berg, M., Birnbaum, L., Bosveld, A. T., Brunstrom, B., Cook, P., Feeley, M., Giesy, J. P., Hanberg, A., Hasegawa, R., Kennedy, S. W., Kubiak, T., Larsen, J. C., van Leeuwen, F. X., Liem, A. K., Nolt, C., Peterson, R. E., Poellinger, L., Safe, S., Schrenk, D., Tillitt, D., Tysklind, M., Younes, M., Waern, F. and Zacharewski, T.,Toxic Equivalency Factors (TEFs) for PCBs, PCDDs, PCDFs for Humans and Wildlife, Environ. Health Perspect, 106, pp. 775-92 (1998)   DOI   ScienceOn
25 Abad, E., Saulo, J., Caixach, J, and Rivera, J., Evaluation of a New Automated Cleanup System for the Analysis of Polychlorinated Dibenzo-p-dioxins and Dibenzofurans in Environmental Samples, J Chromatogr A., 893, pp. 383-391 (2000)   DOI   PUBMED   ScienceOn
26 Focant, J. F., Reiner, E. J., MacPherson, K., Kolic, T. and Sjodin, A., Measurement of PCDDs, PCDFs, and Nonortho- PCBs by Comprehensive Two-dimensional Gas Chromatography- isotope Dilution Time-of-flight Mass Spectrometry (GCxGC-IDTOFMS), Talanta, 63, pp. 1231-1240 (2004)   DOI   ScienceOn
27 Magara, Y, Aizawa, T., Ando, M., Morita, M., Ito, H., Seki, Y and Matsumura, T., Determination of Low Dioxins and PCB's Concentration in Ambient Water using Large Volume In Situ Pre-concentration System, Organohalogen Compounds, 40, pp. 205-210 (1999)
28 Choi, J. W., Kim, K. S., Lee, J. H., Kim, S. H. and Baek K. H., Development of Analytical Method of Dioxins for Ambient Water Sample (1), K Soc. Environ. Anal. Abst., pp. 169-171 (2004)
29 Todaka, T., Hirakawa, H., Tobiihi, K. and Iida, T., New Protocol of Dioxins Snalysis in Human Blood, Fukuoka Igaku Zasshi, 94, pp. 148-157 (2003)   PUBMED
30 Kitamura, K., Nagao, M., Choi, J. W., Hashimoto, S., Ito, H. and Morita, M., Effective Pretreatment of Human Serum Samples for Dioxin Analysis by Solid Phase Extraction and Blue-chitin Column Cleanup, Analyst, 128, pp. 986-993 (2003)   DOI   ScienceOn
31 Patterson, D. G., History and Current Sratus of Fast and Sensitive Analitical Methods for Measuring Compounds of Environmental Concern at the Centers for Disease Control and Prevention, Organohalogen Compounds, 60, pp. 351-354 (2003)
32 Kemmochi, Y., Tsutsumi, K., Arikawa, A. and Nakazawa, H., Micropore-free surface-activated Carbon for the Analysis of Polychlorinated dibenzo-p-dioxins-dibenzofurans and Nonortho- substituted Polychlorinated Biphenyls in Environmental Samples, J Chromatogr A., 977, pp. 155-161 (2002).   DOI   PUBMED   ScienceOn
33 Otaka, H., Shimono, H. and Hashimoto, S., Optimization of Solid-phase Extraction Procedure for Determination of Polychlorinated Dibenzo-p-dioxins, Polychlorinated Dibenzofurans, and Coplanar Polychlorinated Biphenyls in Humic Acid Containing Water, Anal Bioanal Chem., 378, pp. 1854-1860 (2004).   DOI   ScienceOn
34 US EPA Office of Water Regulations and Standards, Method 8290 (revision 0). Polychlorinated Dibenzo-p-dioxins and Polychlorinated Dibenzofurans by High-resolution Gas Chromatographyh/ high-resolution Mass Spectrometry (HRGC/ HRMS) (1994)
35 Saito, K., Takekuma, M., Ogawa, M., Kobayashi, S., Sugawara, Y, Ishizuka, M., Nakazawa, H. and Matsuki, Y.,Extraction and Cleanup Methods of Dioxins in House Dust from Two Cities in Japan using Accelerated Solvent Extraction and a Disposable Multi-layer Silica-gel Cartridge, Chemosphere, 53, pp. 137-142 (2003)   DOI   ScienceOn
36 Tysklind, M., Lundgren, K., Eriksson, L., Sjostrom, M. and Rappe, C., Identifying Training Sets of PCDDs and PCDFs for Use in Chemical and Biological Monitoring, Chemosphere, 27, pp. 47-54 (1993)   DOI   ScienceOn
37 Choi, J. W., Miyabara, Y., Hashimoto, S. and Morita, M., Comparison of PCDD/F and Coplanar PCB Concentrations in Japanese Human Adipose Tissue Collected in 1970-1971, 1994-1996 and 2000, Chemosphere, 47, pp. 591-597 (2002)   DOI   ScienceOn
38 Masuzaki, Y, Matsumura, T., Ezaki, T., Ohashi, M., Ito, H. and Morita, M., High Sensitivity Analysis with Solvent Cut Large Volume (SCL V) Injection Technique, Organohalogen Compounds, 50, pp. 194-197 (2001)
39 Japanese Industrial Standards Committee, Japanese Industrial Standard (JIS K 0311) (1999b)