• 제목/요약/키워드: sag detection

검색결과 61건 처리시간 0.025초

웨이블릿 변환을 이용한 순간전압강하 검출 연구 (A Study of Voltage Sag Detection Using Wavelet Transform)

  • 이교성;이용제;김도훈;김양모
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2002년도 추계학술대회 논문집 전력기술부문
    • /
    • pp.3-5
    • /
    • 2002
  • The fourier transform yields good information on the frequency content of the transient, but the time at which a particular disturbance in the signal occurred is lost. Unlike the fourier transform, the wavelet transform provides a time information in addition to the frequency information. So the wavelet transform is more efficient in detecting power quality disturbances. In this paper, we use the wavelet transform for detecting the voltage sag.

  • PDF

Toxoplasma gondii B1 Gene Detection in Feces of Stray Cats around Seoul, Korea and Genotype Analysis of Two Laboratory-Passaged Isolates

  • Jung, Bong-Kwang;Lee, Sang-Eun;Lim, Hyemi;Cho, Jaeeun;Kim, Deok-Gyu;Song, Hyemi;Kim, Min-Jae;Shin, Eun-Hee;Chai, Jong-Yil
    • Parasites, Hosts and Diseases
    • /
    • 제53권3호
    • /
    • pp.259-263
    • /
    • 2015
  • The increasing prevalence of Toxoplasma gondii infection in the human population in the Republic of Korea (= Korea) is due to various reasons such as an increase in meat consumption. However, the importance of cats in transmitting T. gondii infection through oocysts to humans has seldom been assessed. A total of 300 fecal samples of stray cats captured around Seoul from June to August 2013 were examined for T. gondii B1 gene (indicating the presence of oocysts) using nested-PCR. Fourteen (4.7%) of 300 cats examined were positive for B1 gene. Female cats (7.5%) showed a higher prevalence than male cats (1.4%). Cats younger than 3 months (5.5%) showed a higher prevalence than cats (1.5%) older than 3 months. For laboratory passage of the positive samples, the fecal suspension (0.2 ml) of B1 gene positive cats was orally inoculated into experimental mice. Brain tissues of the mice were obtained after 40 days and examined for the presence of tissue cysts. Two isolates were successfully passaged (designated KNIH-1 and KNIH-2) and were molecularly analyzed using the SAG5D and SAG5E gene sequences. The SAG5D and SAG5E gene sequences showed high homologies with the ME49 strain (less virulent strain). The results indicated the importance of stray cats in transmitting T. gondii to humans in Korea, as revealed by detection of B1 gene in fecal samples. T. gondii isolates from cats were successfully passaged in the laboratory for the first time in Korea.

DWT-based Denoising and Power Quality Disturbance Detection

  • Ramzan, Muhammad;Choe, Sangho
    • IEIE Transactions on Smart Processing and Computing
    • /
    • 제4권5호
    • /
    • pp.330-339
    • /
    • 2015
  • Power quality (PQ) problems are becoming a big issue, since delicate complex electronic devices are widely used. We present a new denoising technique using discrete wavelet transform (DWT), where a modified correlation thresholding is used in order to reliably detect the PQ disturbances. We consider various PQ disturbances on the basis of IEEE-1159 standard over noisy environments, including voltage swell, voltage sag, transient, harmonics, interrupt, and their combinations. These event signals are decomposed using DWT for the detection of disturbances. We then evaluate the PQ disturbance detection ratio of the proposed denoising scheme over Gaussian noise channels. Simulation results also show that the proposed scheme has an improved signal-to-noise ratio (SNR) over existing scheme.

필터뱅크와 적응필터를 이용한 전력품질 외란 검출기법 (Power Quality Disturbances Detection Technique using Filter Bank and Adaptive Filters)

  • 윤재준;이정규;손상욱;배현덕
    • 전기학회논문지
    • /
    • 제61권1호
    • /
    • pp.162-167
    • /
    • 2012
  • In power quality monitoring, it is very important to detect disturbances (sag, swell, transient, and interruption) accurately. In this paper, a detection method for power quality disturbances by combining the filter bank system and adaptive filter is proposed. To decompose power signal, binary tree structured filter bank system is designed. In the filter bank system, the fundamental filter bank(QMF bank) is used as a module in each decomposing level. An adaptive filter is used to improve the detection accuracy of disturbances for each subband signal. In the adaptive filter, the measure of estimated error change is used to detect singular points of power quality disturbances. Computer simulations were performed on synthetic signals which have disturbances to assess the performance of the proposed method.

차세대 파워스테이션의 UPS 동작 검출 알고리즘 (Fault Detection Algorithm for an UPS Operation of Power Station)

  • 정두용;박건욱;이수원;서광덕;원충연
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2010년도 추계학술대회
    • /
    • pp.230-231
    • /
    • 2010
  • In this paper, a fault detection algorithm for an UPS operation of power station is proposed. By adapting the algorithm, a grid-connected power station performs a UPS operation when faults such as sag, swell are occurred. Through a computer simulation, grid faults are simulated and the proposed fault detection algorithm using d, q axis observation method is verified.

  • PDF

역상분 전류 주입을 적용한 3상 인버터 기반 BESS의 단독 운전 검출 방법 (Anti-islanding Detection Method for BESS Based on 3 Phase Inverter Using Negative-Sequence Current Injection)

  • 신은석;김현준;한병문
    • 전기학회논문지
    • /
    • 제64권9호
    • /
    • pp.1315-1322
    • /
    • 2015
  • This paper proposes an active islanding detection method for the BESS (Battery Energy Storage System) with 3-phase inverter which is connected to the AC grid. The proposed method adopts the DDSRF (Decoupled Double Synchronous Reference Frame) PLL (Phase Locked-Loop) so that the independent control of positive-sequence and negative-sequence current is successfully carried out using the detected phase angle information. The islanding state can be detected by sensing the variation of negative-sequence voltage at the PCC (Point of Common Connection) due to the injection of 2-3% negative-sequence current from the BESS. The proposed method provides a secure and rapid detection under the variation of negative-sequence voltage due to the sag and swell. The feasibility of proposed method was verified by computer simulations with PSCAD/EMTDC and experimental analyses with 5kW hardware prototype for the benchmark circuit of islanding detection suggested by IEEE 1547 and UL1741. The proposed method would be applicable for the secure detection of islanding state in the grid-tied Microgrid.

APF UPS간 빠른 Mode Conversion을 위한 새그 검출기법 (The Sag Detection Technique for Fast Mode Conversion between APF and UPS)

  • 성국남;이우철
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2012년도 전력전자학술대회 논문집
    • /
    • pp.260-261
    • /
    • 2012
  • 이 논문은 새그 전압 발생 시 피크 전압을 빠르게 검출하여 Mode Conversion을 빠르게 하기 위한 방법을 제시한다. 기존의 새그전압 검출기법은 DPLL의 D-Q 동기좌표변환을 이용한 방법을 사용한다. 그러나 이 방법을 사용하게 되면 지연시간이 길기 때문에 전압강하가 발생하였을 때 순간적으로 전압강하인지하지 못해 순간정전이나 고조파 등을 생성할 수 있다. 이러한 전압 강하 검출의 지연시간을 짧게 줄인 전압강하 검출기법을 연구하였다.

  • PDF

분산전원이 연계된 배전계통에서의 전압품질 검출에 관한 연구 (A Study on Power Quality Detection Method of Utility interconnected Distributed Generation)

  • 이봉이;김재철;정승복
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2004년도 추계학술대회 논문집 전력기술부문
    • /
    • pp.252-254
    • /
    • 2004
  • This paper studies power quality problem of utility interconnected distributed generation. Recently, electronic devices that are sensitive to power quality have been increasing. Both utility and customer are interested in power quality problem. Therefore, we studied an effect of utility power quality caused by distributed generation. We detect and analysis voltage sag which is one of power quality indicator. Also, we used Matlab to simulate power quality problem.

  • PDF

Genotyping of Toxoplasma gondii from Rats (Rattus rattus) in Riyadh, Saudi Arabia

  • Elamin, Maha H.
    • Parasites, Hosts and Diseases
    • /
    • 제52권3호
    • /
    • pp.257-261
    • /
    • 2014
  • Toxoplasma 3 main clonal lineages are designated as type I, II, and III; however, atypical and mixed genotypes were also reported. This study was conducted for detection of Toxoplasma gondii genotypes in rats (Rattus rattus) in Riyadh region, Saudi Arabia. PCR test on T. gondii B1 gene was conducted on ELISA IgM positive samples for confirmation of the infection. However, genetic analysis of the SAG2 locus was performed to determine T. gondii genotypes using PCR-RFLP technique. PCR test on T. gondii B1gene showed that 22 (81.5%) out of the 27 ELISA IgM positive samples have T. gondii DNA. Genotypic analysis shows that, of the total 22 PCR positive samples, only 13 (59.1%) were of type II, 7 (31.8%) were of type III, and 2 (9.1%) were of an unknown genotype. It is obvious that the prevalence of both type II and III is high in rats. No reports have been available on T. gondii genotypes among rats in Riyadh region, and only little is known about its seroprevalence in rats. Future studies on T. gondii genotypes in rats using multi-locus markers is needed in Riyadh region, Saudi Arabia for better understanding of T. gondii pathogenesis and treatment in humans and animals.

22.9kV 배전선로 적용을 위한 DVR의 새로운 외란검출 기법 및 제어시스템 설계 (The New Voltage Event Detection Method and Control System Design for DVR Applied to 22.9kV Distribution System)

  • 김희중;정용호;권기현;박태범;문전일;전영수
    • 대한전기학회논문지:전력기술부문A
    • /
    • 제55권1호
    • /
    • pp.7-12
    • /
    • 2006
  • This paper proposes the new voltage event detection method using the weight factor of neural network and describes control system design for the DVR(Dynamic Voltage Restorer) consisted of a rectifier and series inverter applied to 22.9kV distribution system. As this method can express the fault level of each phase, we expect the proposed method can make up for disadvantage of synchronous detection method. Also, in this paper, the control system was designed using double deadbeat controller, As it has an inner current control loop and an outer voltage control loop, we can easily limit the current level during the transient intervals by using the current control loop. Simulation and experiment are performed to prove the analysis of the voltage event detection method and double deadbeat controller.