• Title/Summary/Keyword: safety test

Search Result 7,940, Processing Time 0.035 seconds

INTEGRAL BEHAVIOR OF THE ATLAS FACILITY FOR A 3-INCH SMALL BREAK LOSS OF COOLANT ACCIDENT

  • Choi, Ki-Yong;Park, Hyun-Sik;Cho, Seok;Euh, Dong-Jin;Kim, Yeon-Sik;Baek, Won-Pil
    • Nuclear Engineering and Technology
    • /
    • v.40 no.3
    • /
    • pp.199-212
    • /
    • 2008
  • A small-break loss of coolant accident (SB-LOCA) test with a break size equivalent to a 3-inch cold leg break of the APR1400 was carried out as the first transient integral effect test using the ATLAS (Advanced Thermal-hydraulic Test Loop for Accident Simulation). This was the first integral effect test to investigate the integral performance of the test facility and to verify its simulation capability for one of the design-basis accidents. Reasonably good thermal hydraulic data was obtained so that an integral performance of the fluid sub-systems was identified and control performance of the ATLAS was confirmed under real thermal hydraulic conditions. Based on the measured data, a post-test calculation was carried out using the best-estimate thermal hydraulic safety analysis code, MARS 3.1, and the similarity between the expected and actual data was investigated. On the whole, the post-test calculation reasonably predicts the major thermal hydraulic parameters measured during the SB-LOCA test. The obtained data will be used to enhance the simulation capability of the ATLAS and to improve an input model of the ATLAS for simulation of other target scenarios.

Studies on the Safety Assessment of Red-ginseng Radix Extract Solution for Herb-acupuncture (III) (약침용 홍삼추출액의 면역독성, 발열성 및 용혈성시험에 관한 연구)

  • Nam, Yun-Seok;Lee, Yun-Ho
    • Korean Journal of Oriental Medicine
    • /
    • v.2 no.1
    • /
    • pp.129-145
    • /
    • 1996
  • According to the Medical Product Safety Administration Guidelines for safety assessment guinea pigs, mice and rats were used for antigenicity test, rabbits for pyrogenic test and hymolytic test. The results were summarized as follows; 1. The antigenicity test of Red-ginseng radix extract solution for herb-acupuncture did not show any anaphylatic shock but produced IgE in high dose group. 2. The result of the pyrogen test of Red-ginseng radix extract solution for herb-acupuncture was negative. 3. The result of the hemolytic test of Red-ginseng radix extract solution for herb-acupuncture were negative in low and middle dose group but was positive in high dose group.

  • PDF

A Study on Safety Evaluation of Wheel Using Roller Rig Tester (주행시험기를 이용한 차륜의 안전성 평가에 관한 연구)

  • Ham, Young Sam
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.32 no.7
    • /
    • pp.591-595
    • /
    • 2015
  • The roller rig tester for safety performance evaluation of wheel derailment is a test facility which can give the test load condition to the test wheel, similar to the actual dynamic condition in actual running condition. This study describes the evaluation result on the durability of the resilient wheel equipped with the ring damper and the damping material, and installed in the half part of a full scaled bogie in combination with the primary spring when it rotates under the dynamic condition. The evaluation result on durability of resilient wheel after load test of 2 million cycles shows that the safety of wheel is not affected by the applied load in visual inspection and nondestructive test, however, in the bolt used for fastening the ring damper to the wheel the loosening was found. Accordingly the use of self-locking nut and washer is recommended.

Electromagnetic Immunity Test Environments of Advanced Vehicles with Radar Sensor Systems (첨단자동차의 전자파 내성 실험 환경에 관한 연구: 레이더 센서를 중심으로)

  • Kim, Sungbum;Ryu, Jiil;Woo, Hyungu;Yong, Boojoong
    • Journal of Auto-vehicle Safety Association
    • /
    • v.11 no.4
    • /
    • pp.50-56
    • /
    • 2019
  • Recently, automobile industries have developed ADAS, smart cars, connected cars, automated driving systems, which use a variety of sensor systems - ultrasonics, cameras, lidars and radars - and communication systems. It is necessary to examine the electromagnetic immunity of vehicles equipped with those systems. The electromagnetic immunity tests are carried out in an electromagnetic semi anechoic chamber, which is cut off from the outside. It is difficult to create test environments in which the radar sensor systems of vehicles work properly in the test chamber. In this study, test jigs were designed and tested and as a result they are shown to be effective to create test environments for electromagnetic immunity tests of vehicles equipped with radar sensors. We also proposed additional safety standards for immunity tests of vehicles with radar systems that currently do not exist.

Skin Safety Evaluation of a Korean Traditional Prescription, Dansam-samul-tang and Samwhang-sasim-tang (한방 처방제인 단삼사물탕과 삼황사심탕의 피부적용제로의 활용을 위한 피부 안전성 평가 연구)

  • Lee, In-Chul;Kim, Bae-Hwan;Kim, Sung-Ok;Kim, Mee-Kyung
    • Journal of Physiology & Pathology in Korean Medicine
    • /
    • v.25 no.2
    • /
    • pp.212-216
    • /
    • 2011
  • In traditional medicines, Dansam-samul-tang and Samwhang-sasim-tang extracts were known to effects of antioxidant and antimicrobial activity. To investigate the safety evaluation of skin, these extracts were measured to skin safety testing such as primary skin irritation test, eye irritation test and skin sensitization test. The results of the primary skin irritation test and eye irritation test in vitro showed that these extracts included in the nonirritating area. Skin sensitization test results by Guinea Pig Maximization (GPMA) indicated that there was no allergy reaction. Therefore, Dansam-samul-tang and Samwhang-sasim-tang extracts were very safe in every safety test of skin. These results suggests that Dansam-samul-tang and Samwhang- sasim-tang extracts in 1 % concentration can be useful cosmetic ingredients.

A Study on the Techniques of Simulation Test in Automotive Braking System (자동차 제동장치의 시뮬레이션 시험 기법에 관한 연구)

  • 민규식;김형섭
    • Journal of the Korean Society of Safety
    • /
    • v.8 no.2
    • /
    • pp.23-29
    • /
    • 1993
  • In this study, the method of deciding simulation test conditions is developed by computer program compared to actual vehicle test as accurately as possible. These results of analytical test conditions are conformed by simulation test using the brake dynamometer by comparison with test results of actual vehicle. Results of simulation test by these analytical results show good agreement with the vehicle test results. The analytical simulation test conditions provide the input data to brake dynamometer which follows : - each test inertia corresponding to braking deceleration - test condition of input control : brake line pressure - test condition of output control : braking torque

  • PDF

The Effects of Nursing Students' Safety Motivation, Confidence in Performance on Behavior of Safety Management (간호대학생의 안전동기, 안전관리 수행자신감이 안전관리행위에 미치는 영향)

  • Moon, Duck-Hee
    • Journal of Convergence for Information Technology
    • /
    • v.11 no.7
    • /
    • pp.67-74
    • /
    • 2021
  • The purpose of this study was to investigate the safety motivation, confidence in performance, and behavior of safety management and to identify the factors affecting behavior of safety management targeted nursing students. Subjects were 127 nursing students and data were collected by questionnaires from December 1 to December 20, 2020. Data were analyzed using t-test, ANOVA, Scheffe test, Pearson correlation coefficients and multiple regression analysis. Safety motivation was positive correlated with confidence in performance, and behavior of safety management. Confidence in performance was positive correlated with behavior of safety management. Safety motivation and confidence in performance were main factors that affects behavior of safety management. These results suggest to develop education intervention program that include safety motivation, confidence in performance in order to improve behavior of safety management of nursing students.

Study on Optimization of Cytoplasm Conditions for In Vitro Micronucleus Test Using Chinese Hamster Lung Cells (Chinese Hamster Lung Cell을 이용한 in vitro 소핵시험의 세포질 최적화 연구)

  • Paik, Min Kyoung;Kim, Areumnuri;Shin, Hye Rim;Chon, Kyongmi;Park, Kyung-Hun;Ryu, Ji-Hyeok;Moon, Byeong Chul
    • Korean Journal of Environmental Agriculture
    • /
    • v.37 no.3
    • /
    • pp.229-234
    • /
    • 2018
  • BACKGROUND: in vitro micronucleus test (vitMNT) is one of the promising alternative testing methods in genotoxicity test and was adopted as OECD test guideline for chemical registration. This study was conducted to optimize the cytoplasm conditions in vitMNT using Chinese hamster lung (CHL) cell. METHODS AND RESULTS: In this study cytokinesis-block micronucleus test was conducted. Mitomycin C and colchicine were used as positive control chemicals and were treated for three hours (short time) or twenty-four hours (long time). Giemsa solution was used for cell staining. For optimization of vitMNT, the final fixative was prepared as five concentrations (0%, 1%, 3%, 5%, and 25%) of acetic acid in methanol, and treatment times of the final fixative were varied under four conditions (immediately, one hour, four hours, and one day). CONCLUSION: Acetic acid at 1% in methanol as the final fixative was most adequate to preserve the cytoplasm around the nucleus in the interphase cells. Also, fixative treatment time of cell suspension for one to four hours may minimize the cell rupture. These results can be helpful for getting an accurate result promptly due to clear visual distinction to score micronucleus in vitMNT using giemsa solution.

Development of Subminiature Type 3 Composite Pressure Vessel for Cooling Unit in Electric Appliances (전자제품 쿨링 유닛용 초소형 타입 복합재 압력용기 개발)

  • Cho, Sung-Min;Lee, Seung-kuk;Moon, Jong-sam;Lyu, Sung-ki
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.17 no.6
    • /
    • pp.151-157
    • /
    • 2018
  • In this study, we have developed a composite pressure vessel that is compact and can store refrigerant at high pressure to increase the refrigerant volume. The composite pressure vessel is made of aluminum-based duralumin, which has high rigidity and excellent elongation in the inner liner, considering the characteristics of products in the aerospace and defense industry, where the safety of the applied product is considered as a priority. High strength carbon fiber was applied to the outside. In order to evaluate the performance of the developed product, burst test and cycling test were carried out. In burst test, an excellent safety margin equivalent to 2.7 times the operating pressure was obtained. In cycling test, a stable failure mode in which 'pre-burst leak' occurs is proved and the soundness of the product is proved.