• Title/Summary/Keyword: safety device

Search Result 1,823, Processing Time 0.034 seconds

Research on Improvement of Power Control System of Cold & Hot Water Purifier (냉온정수기의 전원 제어 시스템 개선에 관한 연구)

  • Lee, Ki-Yeon;Choi, Chung-Seog;Kim, Dong-Ook;Kim, Hyang-Kon;Kim, Dong-Woo
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.56 no.1
    • /
    • pp.45-50
    • /
    • 2007
  • In this paper, this paper discusses how to improve the power control system of cold and hot water purifiers, in particular, system protecting device against abnormal voltage. The existing power supply control system came with a protecting device composed of varistor device only for impulse-type surges. Even though the existing system senses surge other than impulse-type, the system can not be protected. Accordingly, a new type of power control system was designed to protect the system from surge and ultimately prevent electricity accidents. The power control system suggested in this paper will be designed to protect the system by sensing input voltage and discontinuing power supply by means of SSR if voltage exceeding set value is sensed. To test the designed system, surge was imposed on the existing system and processes of system failure were experimented before safety of the designed power control system was simulated via P-spice program developed by Orcad in order to examine safety and reliability of the system.

Design for a Fuse of High Durability Protection Elements for Improving the Safety of DC Current Measurement Device (직류전류측정기의 안전성 향상을 위한 고내구성 보호소자의 가용체 설계)

  • Lee, Ye Ji;Youn, Jae Seo;Cho, Sung Chul;Noh, Sung Yeo
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.33 no.3
    • /
    • pp.201-207
    • /
    • 2020
  • With the expansion in the use of DC power systems and increased need for system maintenance, the development of measurement devices for maintenance requires high stability. Of the different kinds of DC current measurement devices, the single-shot measurement device causes the input signal of the current measuring unit to initially generate a high inrush current. The high inrush current flows into the signal processor of the meter, shortening the life of the internal fuses and causing failure. Therefore, in this study, the I2t value for increasing the durability of the fuse is designed using the available wire diameter. Operating characteristics for 210~400% over-current of the rated current, which is relatively low over-current, are realized by the plating of low melting tin metal. As a result, a method of designing a fuse element for a DC power supply, which improves the safety of the DC current measurement device by blocking the failure caused by the inrush current, is presented.

Real-time Distributed Control in Virtual Device Network with Uncertain Time Delay for Predictive Maintenance (PM) (가상 디바이스 네트워크상에서 불확실한 시간지연을 갖는 실시간 분산제어를 이용한 예지보전에 관한 연구)

  • Kiwon Song;Gi-Heung Choi
    • Journal of the Korean Society of Safety
    • /
    • v.18 no.3
    • /
    • pp.154-160
    • /
    • 2003
  • Uncertain time delay happens when the process reads the sensor data and sends the control input to the plant located at a remote site in distributed control system. As in the case of data network using TCP/IP, VDN that integrates both device network and data network has uncertain time delay. Uncertain time delay can cause degradation in performance and stability of distributed control system based on VDN. This paper first investigates the transmission characteristic of VDN and suggests a control scheme based on the Smith's predictor to minimize the effect of uncertain varying time delay. The validity of the proposed control scheme is demonstrated with real-time velocity control of DC servo motor located in remote site.

The Development of Small Sluice gate systems without Upper Concrete structure (상부 콘크리트 구조물이 없는 소형 수문 시스템 개발)

  • Kook, Jeong-Han;Kim, Key-Sun
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.12 no.11
    • /
    • pp.4738-4744
    • /
    • 2011
  • This study proposes the system of new small sluice gate operated without the upper concrete structure. The new mechanism is composed of hydraulic system, driving mechanism to feed the floodgate up and down, hydrological locking device, safety device and etc. The hydraulic pumps and control systems away from the location of the sluice gate systems are installed and controled in place. The feed device with the hydraulic rack, pinion and hydraulic actuator is installed on the side of the sluice gate. The following results take the advantages of cost reduction, operation safety and compact product.

A Study on the Analysis of Fire Mechanisms in Electronic Products due to Failure and Malfunction of Thermostats Through Fire Cases and Reproduction Experiments (화재사례 및 재현실험을 통한 온도조절장치 고장 및 오동작으로 인한 전자제품 화재 메커니즘 분석)

  • Jeong-il Lee;Jong-Hwa Im
    • Journal of the Korea Safety Management & Science
    • /
    • v.26 no.1
    • /
    • pp.31-38
    • /
    • 2024
  • In this paper, as there are many cases of fires occurring due to the failure or inoperability of the thermostat of electronic products, the purpose is to test and analyze the risks and probabilities through fire cases and reproduction experiments, and suggest countermeasures. Among electronic products, water purifiers are composed of a refrigerant system with a compressor to make cold water, a heating device to make hot water, and an electric device used as an energy source. Due to the nature of the water purifier manufacturing, these devices are subject to a lot of moisture and dust. etc. exist in large quantities and use electrical energy, so there is a possibility of fire due to short circuit in the wire, electrical abnormal overheating (tracking phenomenon) in the thermostat, electronic board, starting relay, etc., and overheating of the heating device (Band Heater). there is. Therefore, in order to prevent fires from these devices, a system to remove foreign substances inside the water purifier is necessary, the use of heat-resistant (fire-resistant) wires for electrical devices is essential, and the use of non-combustible materials (semi-combustible materials) for each part is necessary to prevent fire. The risk must be eliminated through prevention and combustion expansion prevention devices.

A Study on the Worter-gate Control Device Development using Radio Communication (무선통신을 이용한 수문제어장치 개발에 관한 연구)

  • 이진구;김인주;정영재;손준식;성백섭;김일수;박창언
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2002.05a
    • /
    • pp.612-615
    • /
    • 2002
  • This paper begin a new approach in the water-gate control using radio communication. The dissertation is on the controllable device development of water-gate in the remote distance from water-gate trough the transceiver by radio communication. The proposed water-gate control device is simpe in structure, an suitable for implementation of water-gate control in the remote distance. The remote controller water-gate device inspected the up and down motion of water-gate through the LCD displayer, so that it was very safety driving about the surroundings imformation, over loading and position of water-gate, and so on.

  • PDF

A Study on the Hydraulic Fall Prevention Device (유압식 추락 방지장치에 관한 연구)

  • Choi, Jung-Hun;Koo, Jae-Mean;Seok, Chang-Sung;Huh, Yong;Chang, Sung-Yong
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.27 no.11
    • /
    • pp.78-83
    • /
    • 2010
  • Since a tower crane is too high for a worker to ascend and by the wind in the high altitude, the possibility of a safety accident is very high, a lift assist is used. In this study, the hydraulic fall prevention device using the pressure generation device by Seok, et al. was developed. For this, the effects on the fall prevention performances of factors such as gear clearance, oil viscosity, rotative velocity and so on were evaluated by the analysis of fluid flow using FEM and the prototype was producted and a function test was performed.

Implementation and Application of the Control Surface Deflection Angle measuring device for UAV using Potentiometer (전위차계를 이용한 무인항공기 조종면 변위 측정 장치 구현 및 적용)

  • Kim, Ji-Chul;Choi, Il-Gyu;Gong, Sung-Chul;Cheon, Dong-Ik;Lee, Sangchul;Oh, Hwa-Suk;Kang, Min-young
    • Journal of Aerospace System Engineering
    • /
    • v.3 no.3
    • /
    • pp.13-16
    • /
    • 2009
  • Aircraft flight control surfaces which are one of the most important elements of safety allow a pilot to adjust and control the aircraft's flight attitude. This paper is described of the control surface deflection angle measuring device. Data analysis through ground test and flight test can provide reliability of this device using the present system. It is also shown that measuring system is capable of detecting failure of control surfaces.

  • PDF

Hot-firing Tests of Afterburning Device for a Gas Generator (가스발생기용 후연소 장치 시험 결과)

  • Kim, Mun-Ki;Lim, Byoung-Jik;Kang, Dong-Hyuk;Ahn, Kyu-Bok;Kim, Jong-Gyu;Choi, Hwan-Seok
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2011.04a
    • /
    • pp.79-82
    • /
    • 2011
  • An afterburning device was developed to safely treat unburnt gases of fuel-rich condition discharged by a gas generator. Hot-firing tests for a subscale gas generator were carried out to investigate operation and safety of the afterburning device. When supplying additional liquid oxygen, the length of the afterburning flame was significantly reduced.

  • PDF

Development of Moving and Attaching Diagnosis Device Using IoT (IoT 활용 이동착탈식 열화 진단 장치 개발)

  • Ka, Chool-Hyun;Lee, Dong-Gyu;Kim, Jin-Sa
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.30 no.9
    • /
    • pp.596-601
    • /
    • 2017
  • The advancement and diversification of urban functions has caused an increasing need to improve the reliability of power supplies. The diversification of urban areas causes social disruptions by paralyzing urban functions during power outages. A large power outage occurs in the event of an accident, owing to the subduction of distribution lines. Therefore, in recent years, for the sake of the environment and safety, the safety diagnosis of electric power facilities has become an important issue. In this system, because thermal information changes rapidly during unattended monitoring owing to heat concentration phenomenon due to abnormal load or deterioration, studies have been conducted on the development of a device that can notify the manager at all times.