• 제목/요약/키워드: room acoustic analysis

검색결과 56건 처리시간 0.022초

Acoustic mode 를 고려한 공동주택 중량충격음 소음해석 (The numerical analysis of heavy-weight impact noise for an apartment houses considering acoustic mode)

  • 문대호;황재승;박홍근;홍건호;임주혁
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2009년도 춘계학술대회 논문집
    • /
    • pp.394-402
    • /
    • 2009
  • To investigate the heavy-weight impact noise of apartment houses, numerical analysis was performed. The analysis acoustic pressure consider acoustic mode by finite element method. The variables considered effecting on the acoustic pressure are the Acoustic mode, acoustic damping, and the impulse load. The heavy-weight impact noise is a changeable value in the room. Since the most part of the frequency component of heavy-weight impact noise has low frequency. The noise in low frequency is related to the vibration of structure, the reflection of acoustic wave caused by wall and the standing wave called by acoustic mode. The prediction by the numerical analysis was verified with test result of the heavy weight-impact noise at apartment houses.

  • PDF

정상상태조건에서의 개구부로 연결된 커플룸의 음향 특성 (Room Acoustic Properties of Coupled Rooms Connected by an Aperture in the Steady State Condition)

  • 나혜중;임병덕
    • 한국소음진동공학회논문집
    • /
    • 제26권3호
    • /
    • pp.315-322
    • /
    • 2016
  • Room acoustic properties of coupled rooms connected by an aperture has been analyzed using statistical acoustic model based on the diffused sound field assumption, which has limitation in dealing with the parameters such an room geometries and non uniform absorptivity of the boundary surfaces. In order to overcome these difficulties the acoustic diffusion model has been introduced, by which distribution of the acoustic energy density can be analyzed for various shapes and wall absorptivity. In this study acoustic properties of coupled rooms connected by an aperture(e.g. door) is analyzed using acoustic diffusion equation, which is solved numerically. The mean energy densities of two rooms obtained by the diffusion model are compared with those from the statistical model. The results show good agreement for various coupling aperture sizes and absorption coefficients. For a limiting case when the partition wall is substituted by an aperture and the two rooms eventually forms a single room, results of coupled room analysis using diffusion model show good agreement with those of a single room.

중량충격원 충격에 따른 공동주택 실내공간의 구조음장 해석 모델링방법에 관한 연구 (A Study on the Structural-acoustic Analysis Modeling Methods of the Room with Heavy Impact Noise Source)

  • 이재광;구해식
    • KIEAE Journal
    • /
    • 제9권6호
    • /
    • pp.81-87
    • /
    • 2009
  • The purpose of the present study is to establish structural noise analyzing method for apartments building floor with structural-acoustic coupling analysis modeling. Noise through floor in the room is recognized as a significant problem with the consequence that noise isolation technique has been studied in the various fields of industry. From among noise factors, resonance sound is the main reason for solid noise of the floor, which is occurred by mechanical vibrations of the acoustic boundary line and the change of velocity. To analyse this phenomenon, numerical computation methods are provided in many fields, In this study, evaluation method for slab is established using finite element method, and a case study for analyzing acoustic phenomenon was suggested. The results show that numerical method, especially F.E.M, has a good approximation to predict noise at floors.

개구부로 연결된 3중 커플룸의 음향특성 (Acoustic Properties of Three-room Coupled System by Connected Two Apertures)

  • 나혜중;임병덕
    • 한국소음진동공학회논문집
    • /
    • 제26권3호
    • /
    • pp.340-349
    • /
    • 2016
  • A coupled room system consists of adjacent rooms and apertures where the sound energy is exchanged between the two rooms. Acoustically, a coupled room system shows a non-exponential decay profile. Most of the related researches have been to analyze the acoustic properties of two-room coupled system so far whereas three-room coupled system were seldom studied. In this regard, this paper aims to analyse the distribution of sound pressure level, sound decay curve of three-room coupled system and sound energy flow between them by using the acoustic diffusion model and to further verify them through experiments. Firstly, the sound pressure level distribution and mean sound pressure level in the steady-state condition are analyzed at various frequencies and source locations. Good agreements are observed in both experiments and analysis results. Secondly, two double slope effect quantifiers of sound attenuation, LDT/EDT and LDT/T10 are compared at various frequencies and for different source locations. The result indicates that LDT/T10, less affected by the early reflection patterns than LDT/EDT, is more suitable to the analysis and experiments of a multi-slope sound decay curve. Lastly, the sound energy flow in each room is analyzed based on the acoustic diffusion model. After the early decay stage, the sound energy is observed to flow from the room with a long reverberation time to the room with a short one.

음향모드를 고려한 공동주택 중량충격음 소음해석 (Numerical Analysis of Heavy-weight Impact Noise for Apartment Units Considering Acoustic Mode)

  • 문대호;박홍근;황재승;홍건호;임주혁
    • 한국소음진동공학회논문집
    • /
    • 제22권7호
    • /
    • pp.676-684
    • /
    • 2012
  • Numerical analysis was performed to investigate the heavy-weight impact noise of apartment houses. The FEM is practical method for prediction of low-frequency indoor noise. The results of numerical analysis, the shape of the acoustic modes in room-2 are similar to that of acoustic pressure field at the fundamental frequency of acoustic modes. And the acoustic pressure was amplified at the natural frequency of the acoustic modes and structural modes. The numerical analysis result of sound pressure level at 63 Hz and 125 Hz octave-band center frequency are similar to the test results, but at 250 Hz and 500 Hz have some errors. Considering most of bang-machine force spectrum exists below 100 Hz, the noise at 250 Hz and 500 Hz are not important for heavy-weight impact noise. Thus, the FEM numerical analysis method for heavy-weight impact noise can apply to estimate heavy-weight impact noise for various building systems.

음향시뮬레이션을 이용한 수차 발전기소음의 저감효과 분석 (Analysis on Reduction Effect of Hydraulic Turbine Dynamo Noise using Acoustic Simulation)

  • 정은정;주덕훈;김재수
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2007년도 추계학술대회논문집
    • /
    • pp.248-252
    • /
    • 2007
  • As Waterpower Generation generates electricity using the difference of altitude of water, also let the turbine revolves through water pipe, at this time the revolving turbine causes exceedingly huge noise. Accordingly, not only those workers in the hydraulic turbine dynamo room are suffering the difficulties in mutual communication, but also those workers in the adjacent office are enduring the obstruction to the business due to the noise. Therefore, this Study has analyzed the reduction effect on the noise of hydraulic turbine dynamo room utilizing computer simulation, through the preceding research with the optimized model for architectural acoustic factor of the hydraulic turbine dynamo room. It is considered that such research result could be applied as the useful material for improvement of acoustic performance and noise-reduction effect at other similar hydraulic turbine dynamo room in the future.

  • PDF

3차원 파워흐름유한요소법을 이용한 인접한 두 실내에서의 진동음향 해석 (Vibro-acoustic Analysis of Adjoined Two Rooms Using 3-D Power Flow Finite Element Method)

  • 김성희;홍석윤;길현권;송지훈
    • 한국소음진동공학회논문집
    • /
    • 제20권1호
    • /
    • pp.74-82
    • /
    • 2010
  • Power flow analysis(PFA) methods have shown many advantages in noise predictions and vibration analysis in medium-to-high frequency ranges. Applying the finite element technique to PFA has produced power flow finite element method(PFFEM) that can be effectively used for analysis of vibration of complicated structures. PFADS(power flow analysis design system) based on PFFEM as the vibration analysis program has been developed for vibration predictions and analysis of coupled structural systems. In this paper, to improve the function of vibro-acoustic coupled analysis in PFADS, the PFFEM has been extended for analysis of the interior noise problems in the vibro-acoustic fully coupled systems. The vibro-acoustic fully coupled PFFEM formulation based on energy coupled relations is extended to structural system model by using appropriate modifications to structural-structural, structural-acoustic and acoustic-acoustic joint matrices. It has been applied to prediction of the interior noise in two room model coupled with panels, and the PFFEM results are compared to those of statistical energy analysis(SEA).

다수의 출구를 가진 선박용 대형 저소음 룸유닛 개발 (Development of shipboard large-sized low-noise room unit with multiple outlets)

  • 김상렬;김현실;이성현;박근효
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2012년도 춘계학술대회 논문집
    • /
    • pp.600-605
    • /
    • 2012
  • In this paper, the acoustic performance of a shipboard large-sized room unit is studied. The room unit is a kind of rectangular absorptive chamber with a partition whose surface absorptive material with fabric skin is attached to. The room unit has one inlet and three outlet. At the inlet, a plane damper is installed to control the flow rate. The acoustic performance of a prototype room unit is measured using a HVAC mock-up. It is shown that its insertion loss is comparable with that of a commercially-used room unit but the developed room unit generates flow noise higher than the other one. The major source of flow noise is analyzed by NADS-R, the noise analysis program for room unit. Cone-shaped dampers are proposed to be used as the damper of a room unit to reduce flow noise. It is shown that the cone-shaped damper decrease flow noise remarkably.

  • PDF

다수의 출구를 가진 선박용 대형 저소음 룸유닛 개발 (Development of Shipboard Large-sized Low-noise Room Unit with Multiple Outlets)

  • 김상렬;김현실;이성현;박근효
    • 한국소음진동공학회논문집
    • /
    • 제22권5호
    • /
    • pp.468-473
    • /
    • 2012
  • In this paper, the acoustic performance of a shipboard large-sized room unit is studied. The room unit is a kind of rectangular absorptive chamber with a partition whose surface absorptive material with fabric skin is attached to. The room unit has one inlet and three outlets. At the inlet, a plane damper is installed to control the flow rate. The acoustic performance of a prototype room unit is measured using a HVAC mock-up. It is shown that its insertion loss is comparable with that of a commercially-used room unit but the developed room unit generates flow noise higher than the other one. The major source of flow noise is analyzed by NADS-R, the noise analysis program for room unit. Cone-shaped dampers are proposed to be used as the damper of a room unit to reduce flow noise. It is shown that the cone-shaped damper decrease flow noise remarkably.

실내음향 해석을 위한 위상 빔 추적법의 사용시 오차에 관하여 (On the Errors of the Phased Beam Tracing Method for the Room Acoustic Analysis)

  • 정철호;이정권
    • 한국음향학회지
    • /
    • 제27권1호
    • /
    • pp.1-11
    • /
    • 2008
  • 기하음향학 방법들을 이용한 중주파수 해석의 어려움을 해결하기 위하여 소리의 전파에서 위상 정보를 고려한 위상 기하음향학 방법이 제안되었다. 위상 기하음향학 방법은 위상정보를 고려하여 중주파수 대역의 간섭 현상을 설명할 수 있는 장점을 가지고 있다. 그러나 이러한 방법들을 이용하여 소리의 파동성으로 대표되는 저주파수 현상들을 모두 설명할 수 없다. 특히 저주파수 대역에서는 모서리나 장애물에 의한 회절현상을 고려하지 못하여 전달함수나 충격응답의 예측시 오차가 발생한다. 또한 실수인 흡음 계수를 사용한 해석 결과는 측정치와 차이를 보이므로 반사 계수의 잘못된 위상 정보는 교정되어야 한다. 본 연구에서는 균일 회절 이론을 병합한 위상 빔 추적법의 결과를 기존의 위상 빔 추적법의 결과와 비교하였다. 또한 벽면 반사계수의 위상을 변화시키며 위상 정보의 영향을 조사하였다. 제안된 오차 보정 방법들을 이용하면, 좀더 낮은 주파수 대역까지 정확성을 향상시켜 위상 빔 추적법을 실내음향 예측에 적용할 수 있다.