• Title/Summary/Keyword: room

Search Result 15,331, Processing Time 0.036 seconds

The Function of the Living Room and Anbang through the Activities of Daily Living and Family Rituals (일상 및 가정행사 공간을 통해 본 거실과 안방의 기능 -1992년과 2002년의 자녀성년기 가정의 비교를 중심으로-)

  • 장상옥;신경주
    • Journal of the Korean housing association
    • /
    • v.14 no.5
    • /
    • pp.83-94
    • /
    • 2003
  • The aim of this study was to investigate the trend of the room where activities of daily living and family rituals(activities of non-daily living) were performed between 1992 and 2002. Research data was collected in 1992 and 2002 from households living in Seoul that have university student by using questionnaire surveys. Data was analyzed using the SPSS package program. The major findings of this study were as follows: 1) Living room was a multi-function space for various activities: receiving guests, family communication, ironing, sewing and dining as well as a kitchen. Anbang(master bed room) is the place where the couple sleeps. Anbang's function has changed from a multi-function space to a private space. 2) Most of the families performed the majority of the family rituals in the living room and Anbang. In 1992, traditional events and birthday parties were performed in Anbang, but in 2002, the trend has changed. This would mean that with time the majority of the family rituals were held in the living room. 3) Space planning is required to meet the dwellers' use of living room and Anbang.

Actual conditions on the Living Environment of Small-scale Group-homes for the Elderly (고령자용 소규모 그룹홈의 생활환경 실태)

  • Kim, Hyun-Jin;An, Ok-Hee
    • Journal of the Korean housing association
    • /
    • v.19 no.3
    • /
    • pp.21-29
    • /
    • 2008
  • To investigate the actual conditions on the living environment of group-homes for the elderly and their living environment, 4 group-homes were surveyed. As the results, conditions of location for the group-home of the elderly looked positive, on the other hand, safety for criminal prevention, accessability and convenient facilities were not on level satisfied. The average area of each space in the group-home indicated that the bed room was $11.21\;m^2$, the living room $28.13\;m^2$, the kitchen $23.59\;m^2$, and the bath room had an integrated type of bath room and toilet $7.63\;m^2$. The physical environments of each space in the group-home were investigated, In bed room, door, windows and illumination were relatively good but safety was extremely inferior. Living room mostly looked good except the doorsill which needs refurbishment. In kitchen, cooking table, windows, illumination, ventilator were somewhat satisfactory but gas-warning device should have been installed. In addition, in bath room and toilet, location, door, window, illumination and finished material were satisfactory. But the stepped difference between the bath room and other space, safety-bar, emergency bell and floor heating system were seriously deteriorated and must be improved for the safety of the elderly. Conclusively, living environment of group-home for the elderly is mainly satisfactory but it was necessary to take a consideration for their safety.

Development of Temperature Control System for Cold Storage Room Using Fuzzy Logic (퍼지논리를 이용한 저온저장고의 온도제어시스템 개발)

  • 양길모;고학균;조성인
    • Journal of Biosystems Engineering
    • /
    • v.25 no.2
    • /
    • pp.107-114
    • /
    • 2000
  • Low temperature storage method is to increase the value of agricultural products by reducing quality loss and regulate consignment time by controlling respiration rates of agricultural products. Respiration rate of agricultural products depends on several factors such as temperature, moisture, gas composition and a microbe inside the storage room. Temperature is the most important factor among these, which affects respiration rate and causes low or high temperature damage. Fuzzy logic was used to control the temperature of a storage room ,which uses information of uncertain facts and mathematical model for room temperature control . Room temperature was controlled better by using fuzzy logic control method rather than on-off control method. Refrigerant flow rates and temperature deviations were measured for on-off system using TEV(temperature expansion valve) and for fuzzy system using EEV(Electrical Expansion Valve) . Temperature of the Storage room was lowered faster by using fuzzy system than on -off system. Temperature deviation was -0.6~+0.9$^{\circ}C$ for on-off system and $\pm$0.2$^{\circ}C$ for fuzzy system developed. Temperature deviation and variation of temperature deviation were used as inout parameters for fuzzy system. The most suitable input and output value were found by experiment. Cooling rate of the storage room decreased while temperature deviation increased for the sampling time of 20 sec.

  • PDF

Finite Element Analysis of the Room Temperature Nanoimprint Lithography Process with Rate-Dependent Plasticity (변형률속도를 고려한 상온 나노임프린트 공정의 유한요소해석)

  • Song J. H.;Kim S. H.;Hahn H. Thomas;Huh H.
    • Proceedings of the Korean Society for Technology of Plasticity Conference
    • /
    • 2005.10a
    • /
    • pp.63-66
    • /
    • 2005
  • Nanoimprint lithography (NIL) process at room temperature has been newly proposed in recent years to overcome the shape accuracy and sticking problem induced in a conventional NIL process. Success of the room temperature NIL relies on the accurate understand of the mechanical behavior of the polymer. Since a conventional NIL process has to heat a polymer above the glass transition temperature to deform the physical shape of the polymer with a mold pattern, viscoelastic property of polymer have major effect on the NIL process. However, rate dependent behavior of polymer is important in the room temperature NIL process because a mold with engraved patterns is rapidly pressed onto a substrate coated with the polymer by the hydraulic equipment. In this paper, finite element analysis of the room temperature NIL process is performed with considering the strain rate dependent behavior of the polymer. The analyses with the variation of imprinting speed and imprinting pattern are carried out in order to investigate the effect of such process parameters on the room temperature NIL process. The analyses results show that the deformed shape and imprint force is quite different with the variation of punch speed because the dynamic behavior of the polymer is considered with the rate dependent plasticity model. The results provide a guideline for the determination of process conditions in the room temperature NIL process.

  • PDF

A study on DCGL determination and the classification of contaminated areas for preliminary decommission planning of KEPCO-NF nuclear fuel fabrication facility

  • Cho, Seo-Yeon;Kim, Yong-Soo;Park, Da-Won;Park, Chan-Jun
    • Nuclear Engineering and Technology
    • /
    • v.51 no.8
    • /
    • pp.1951-1956
    • /
    • 2019
  • As a part of the preliminary decommissioning plan of KEPCO-NF fuel fabrication facility, DCGLs of three target radionuclides, 234U, 235U, and 238U, were derived using RESRAD-BUILD code and contaminated areas of the facility were classified based on contamination levels from the derived DCGLs. From code simulations, one-room modeling results showed that the grinding room in building #2 was the most restrictive (DCGLgross = 10493.01 Bq/㎡). The DCGLgross results in contaminated areas from one-room modeling were slightly more conservative than three-room modeling. Prior to the code simulation, field survey and measurements conducted by each survey unit. For a conservative approach, the most restrictive DCGLgross in each survey unit was taken as a reference to classify the contaminated areas of the facility. Accordingly, seven rooms and 37 rooms in the nuclear-fuel buildings were classified as Class 1 and Class 2, respectively. As expected, fuel material handling and processing rooms such as the grinding room, sintering room, compressing room, and powder collecting room were included in the Class 1 area.

Fire Hazard Analysis and Performance Based Fire safety Design for the Clean Room in Semiconductor Factory (반도체공장 Clean Room에 대한 화재요인 분석 및 성능위주 화재안전설계)

  • Han, Su-Jin;Kang, Kyung-Sik
    • Proceedings of the Safety Management and Science Conference
    • /
    • 2006.11a
    • /
    • pp.325-336
    • /
    • 2006
  • This research analyzes clean room major fire prevention standard of clean Room (FM, IRI, and NFPA Code), the structure of Performance-Based Fire Safety Design (PBD) applied the korean fire industry situation. Performance-Based Fire Safety can operate effectively the performance of fire protection equipment & building design, so the fitness of fire safety system can be embodied by operating this. moreover, cost to be consume fire safety of real building can reduce and Performance-Based Fire Safety is considered to important technique in fire protection field. A fire in a clean room may cause a serious loss by spreading smoke particles. We will be investigated by using a computational fluid dynamics, for loss prevention by smoke spreading from one fire area to another for clean room and compared the Performance-Based Fire Safety Design with the prescriptive code design. The methodology of fire safety performance-based fire safety design and guarantee of many kinds design skill of fire system and developing design procedure will be very serious one in order to improve efficiency of domestic system. Therefore, This research will be contributing to secure safety of clean room and to set up the performance-based fire safety design in Korea by regulation for the performance-based fire safety design effectively.

  • PDF

Fire Hazard Analysis and Performance Based Fire safety Design for the Clean Room in Semiconductor factory(1) (반도체공장 Clean Room에 대한 화재요인 분석 및 성능위주 화재안전설계(1))

  • Han, Su-Jin;Kang, Kyung-Sik
    • Journal of the Korea Safety Management & Science
    • /
    • v.8 no.5
    • /
    • pp.211-229
    • /
    • 2006
  • This research analyzes clean room major fire prevention standard of clean Room(FM, IRI, and NFPA Code), the structure of Performance-Based Fire Safety Design(PBD) applied the korean fire industry situation. Performance-Based Fire Safety can operate effectively the performance of fire protection equipment & building design, so the fitness of fire safety system can be embodied by operating this. moreover, cost to be consume fire safety of real building can reduce and Performance-Based Fire Safety is considered to important technique in fire protection field. A fire in a clean room may cause a serious loss by spreading smoke particles. We will be investigated by using a computational fluid dynamics, for loss prevention by smoke spreading from one fire area to another for clean room and compared the Performance-Based Fire Safety Design with the prescriptive code design. The methodology of fire safety performance-based fire safety design and guarantee of many kinds design skill of fire system and developing design procedure will be very serious one in order to improve efficiency of domestic system. Therefore, This research will be contributing to secure safety of clean room and to set up the performance-based fire safety design in Korea by regulation for the performance-based fire safety design effectively.

Analysis of the Bacteria in Nuclear Medicine (핵의학 검사실내 세균 분석)

  • Shin, Seong-Gyu;Lee, Hyo-Yeong
    • Journal of the Korea Safety Management & Science
    • /
    • v.19 no.2
    • /
    • pp.95-100
    • /
    • 2017
  • In this study, the bacterial contamination level of equipments and devices in the nuclear medicine department of a university hospital was investigated. CNS was detected from the sample collected from the door opening button of the nuclear medicine department. Bacillus sp. was detected from the table and CNS with Bacillus sp. were detected from the control button at the PET-CT room no.1. Also, CNS was detected from the table and the control button at the PET-CT room no.2. In the distribution room no.1, CNS and Bacillus sp. were detected while CNS being detected from the distribution room no.2 and CNS with Bacillus sp. being detected from the distribution room no.3. In the injection room, Enterrococcus faecium and Pontoea sp. were detected. On the table of the ecsomatics room, Pontoea sp. was detected. Bacillus sp. was detected from the inside of the syringe Pb shield and CNS was detected from the outside. Enterrococcus faecium was detected from the Gamma camera table and Bacillus sp. was detected from the door grip. On the chair at the patient waiting room, Pseudomonas aeruginosa abd Bacillus sp. were detected. Therefore, it was understood that infection should be prevented by securely sterilizing examination devices after each examination, maintaining cleanliness by regular sterilization of waiting chairs and such objects with a number of direct contacts with patients, and infection education for the features of nuclear department.

A Study on the Characteristics of Space Programs for Senior Center in Japan (일본 노인복지센터의 공간구성 특성에 관한 연구)

  • 소준영
    • Korean Institute of Interior Design Journal
    • /
    • no.29
    • /
    • pp.153-162
    • /
    • 2001
  • This study suggests the basic data required in setting up the standard for the architectural planning of Korean senior center by analyzing the standard and current situation of a senior center in Japan that has the welfare facility system similar to that of Korea and understanding its architectural characteristics. 1) Basic spaces that constitute the senior center in Japan are meeting room, lecture room, library, multipurpose meeting room, conference room, game-recreation room, kitchen, lounge, locker room and office. ADL, kitchen, relaxing room, private bathroom, and special bathroom are needed for adult day care as establishments as an annex and work room is also required for Job training. 2) The area of a senior center is calculated in consideration of its space organization that are required as basic. For the type "A", minimum area of 1,256.42 $m^2$2 and maximum area of 2,050.56$m^2$ and for the type "B", minimum area of 812000$m^2$ and maximum area of 1,604.14$m^2$ are suggested as optimum areas. 3) The circulation planning is presented by the connected between the space organization as well as the circulation system in day care center.

  • PDF

An Analysis on The Visual Configuration of an Exhibition Space in Art Museum - Focusing on an Exhibition space Room-to-room - (미술관 전시공간의 시각구조 분석 - 개실형 전시공간의 분석을 중심으로 -)

  • Lee, Jong-Sook;Lim, Che-Zinn
    • Korean Institute of Interior Design Journal
    • /
    • v.16 no.6
    • /
    • pp.197-204
    • /
    • 2007
  • In the spatial configuration of room-to-room art museums, openings and walls are important physical factors, and openings are a medium for connecting spaces. Also, by spatially composing walls and openings, spaces can be connected visually and physically, and movements and directions may vary depending on the location or size of walls and openings. In this study, 5 museums are investigated: Sainsbury Wing in London, Gemaldegalerie In Berlin, Alte Pinakotkek in Munich, Neue Pinakothek in Munich, and Staatsgalerie Stuttgart in Stuttgart. Using DepthMap program, the characteristics of visual-spatial composition of each museum are derived by comparing the Connectivity, Visual integration, and Isovist maximum radial. From an analysis of spatial distribution, a relationship with visibility is investigated. The results of this study showed that the combination of visual axial lines affect the spatial configuration of the room-to-room museums. Depending on the location of opening, the museums can be classified as follows: 1) Museums with the 1st visual axial line and the 2nd and 3rd auxiliary visual axial lines ; 2) museums with several equal visual axial lines; and 3) museums with only center axial line.