• Title/Summary/Keyword: rooftop

Search Result 282, Processing Time 0.034 seconds

Exploration of a Light Shelf System for Multi-Layered Vegetable Cultivation (자연광 다층 작물재배를 위한 광선반 시스템에 관한 연구)

  • Jang, Seong-Teak;Chang, Seong-Ju
    • KIEAE Journal
    • /
    • v.13 no.2
    • /
    • pp.61-66
    • /
    • 2013
  • This study is to eliminate the need for conventional high density plant factory's artificial light source such as LED to reduce the initial investment of the light source installation as well as the operation cost. Use of solar light could enhance the quality of the vegetables similar to those grown in the natural environment. Provision of solar light into the multilayer vegetable cultivation facilities and collecting maximum and sustainable sunlight without too much loss by tracing solar path and properly distributing it through careful control during daytime are crucial for realizing the investigated rooftop light shelf system for multi-layered vegetable cultivation. In this study, we developed an innovative way of effectively allocating sunlight inside even to otherwise shaded zone of a multi-layer vegetable cultivation facility. To prove the effectiveness of the system's sunlight collection and distribution capability, both simulation and experiment in Daejeon are performed and the outcome is analyzed.

Building Modeling and Terrain Integration System on Satellite Image (위성영상을 이용한 건물 모델링 및 지형 정합 시스템)

  • Oh, Seon-Ho;Jung, Soon-Ki;Kim, Sang-Hee;Kim, Jeong-Hwan
    • Proceedings of the Korean Information Science Society Conference
    • /
    • 2008.06c
    • /
    • pp.549-554
    • /
    • 2008
  • 도시와 같은 광범위한 영역에 대한 지형, 지물의 기하 정보를 추출 또는 복원하는 기술은 공간 영상정보 시스템을 비롯한 다양한 응용분야에서 사용되고 있으며, 이러한 필요에 따라 중요성이 더욱 커지고 있다. 본 논문은 위성 영상에서 건물의 footprint와 rooftop, 그림자 정보를 이용하여 건물을 반 자동으로 모델링하고, 이를 지형에 정합하는 시스템을 제안한다. 제안하는 시스템은 사용자의 직접적인 조작과 자동으로 이루어는 부분을 조합하여, 최소한의 사용자 조작으로 건물을 모델링하고, 지형에 의한 요소를 고려하여 건물의 실제 위치를 보정하여 지형과 정합을 수행한다.

  • PDF

Development of Automatic Operating System for Exit Door using RF (무선을 이용한 비상문 자동개폐 시스템 개발)

  • Lim Youn-Sub;Hwang Byung-Kon
    • Journal of Korea Society of Industrial Information Systems
    • /
    • v.11 no.1
    • /
    • pp.7-12
    • /
    • 2006
  • In this paper, we develop a control system with fire receiver and emergency light that controls (manages) emergency door by wireless signals which prevents crime but also helps evacuate in (fire) emergency. This automatic door operator can be installed on any buildings which have a problem of opening or shutting emergency doors, and it is especially good for buildings with high fire vulnerabilities such as complex buildings, apartments and multistoried buildings without easy control of rooftop doors.

  • PDF

Using a Micro-flown device to measure acoustical properties of green roof systems (Micro-flown 장비를 이용한 옥상녹화재료 음향 물성치 실험)

  • Yang, Hong-Seok
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2014.10a
    • /
    • pp.870-873
    • /
    • 2014
  • Green roof systems has widely been used on rooftop of buildings by considering environmental benefits in aspects of bio-diversity, storm-water runoff as well as noise reduction. To predict noise reduction effect by green roof systems, it is necessary to measure in-situ acoustical properties of the components by devices enabling in-situ measurements. In this study, Micro-flown, which is the state of the arts device to measure in-situ normalized impedance and absorption coefficient has been used to measure acoustical properties of green roof materials according to different water saturation condition in the materials.

  • PDF

A study of Building Mix-Design and Construction Process to Reduce the Combined Deterioration of Plain Concrete. (옥상 무근콘크리트 복합열화 방지를 위한 시공 프로세스 구축 및 배합 설계에 관한 연구)

  • Kim, Dae-Geon;Lee, Woo-Geun;Kang, Ye-Jin;Yeo, Dong-Kyu;Kim, Do-Hun;Lee, Dong-Oun
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2018.05a
    • /
    • pp.85-86
    • /
    • 2018
  • In the case where the building's rooftop was laid without any foundation, the combined deterioration, such as the repetition of shrinkage and expansion caused by temperature changes, caused further cost generation and damage. To prevent this, the concrete mixing design and construction process shall be established to resist combined deterioration.

  • PDF

Study on tensile performance change by recycled materials of TPO sheet applied to rooftop and artificial ground Rootproofings (옥상 및 인공지반 방근공사에 적용되는 TPO시트의 재생 소재 적용에 따른 인장성능 변화 연구)

  • Kim, Sun-Do;Kim, Jin-Sung
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2018.05a
    • /
    • pp.103-104
    • /
    • 2018
  • Recently, in addition to greening of roof and artificial soil, Rootproofing to prevent damage to the waterproof layer and structures by roots is recognized as an important task. Therefore, various related products and construction methods have been developed and applied in the field. However, in the case of synthetic polymer-based sheets most commonly used in domestic construction sites, Most are produced using 100% new materials that are not suitable for green trends such as resource conservation and environmental protection. Therefore, in this study, we developed TPO sheet using recycled material, which is a technology that can secure eco-friendliness by utilizing recycled resources. As a result of the evaluation of tensile performance of the TPO sheet according to the recycled material content, The tensile strength of the specimens with the recycled content of 50 ~ 70% was the highest, The elongation rate of the specimen with the recycled content of 30 ~ 40% was the best.

  • PDF

A Study of the Proposes of GRS Prototype for various purpose achievement and it's Efficiency Comparative Experiment (Green Roof System의 다양한 성능 추구를 위한 공법 제시 및 성능 비교 실험 연구)

  • Jang, Dae-hee;Kim, Hyeon-soo;Lee, Keon-Ho;Park, Chang-Young
    • KIEAE Journal
    • /
    • v.6 no.2
    • /
    • pp.59-66
    • /
    • 2006
  • Green Roof Systems are embossed that realize ecological architecture as a substantially alternative plan. So, a Purpose of the study is seeking to optimize expectation effect through the Green Roof System. we set possible object and propose the prototype on the basis of the existing Green roof System technologies. We visualize a proposed Prototype apply various materials and methods. and we analyse the effects of Green Roof System upon our City climate with use energy efficiency comparison the Green roof system with the Concrete Rooftop. We'll Provide the low data for The prospects of City climate improvement through the a ripple effect on Green Roof System and for activation of Green Roof Technology.

A study on the External Insulation and Waterproof Method of Rooftop (옥상부 외단열 및 외방수 공법 제안에 관한 기초연구)

  • Jang, Dae-Hee
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2019.05a
    • /
    • pp.137-138
    • /
    • 2019
  • To overcome the limitation in relation to thermal insulator's selection and installation method that is suitable for exterior insulation and waterproof construction methods, a production basis of thermal insulators of which manufacturing knowhow is held by companies was ensured and future-oriented construction methods to adopt new materials were applied. Performance verification was conducted through performance and mock-up tests of thermal transmittance on the cross sections where the flexible insulators were applied based on the improved prototype and performance data were obtained. To overcome the biggest drawbacks (walking feeling and damage etc.) in the exterior insulation and waterproof construction method, inserting a protective layer between thermal insulator and water-proof layer was proposed, and polypropylene corrugated cardboards.

  • PDF

Effects of climate condition on concrete slab with modified-latex (외기조건이 개질된 라텍스 혼입콘크리트 슬래브 표면에 미치는 영향)

  • Cha, Hun;Kim, Dae-Geon;Choi, Sang-Hwan;Moon, Kyeong-Sik
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2014.11a
    • /
    • pp.7-8
    • /
    • 2014
  • Latex-modified concrete using ready mix concrete (R-LMC) was developed for application of building construction project (specifically, the rooftop of a parking garage unable to use heavy equipments for bridge deck overlay) due to three major outstanding properties of R-LMC; bond strength, resistance of cracks at early age, and resistance of freezing and thawing. However, R-LMC at the placement stage is required to be sufficiently cured because R-LMC is very sensitive to rate of evaporation of surface moisture. This study focused on effects of different curing methods and climate condition on cracks on the surface of hardened R-LMC considering the chart of rate of evaporation of surface moisture from concrete provided by American Concrete Institute in manual for placement of latex modified concrete.

  • PDF

The Experimental Study of Radiant Cooling Test System under Different Covers (복사냉각 시스템에서 커버의 영향)

  • Byun, Ki-Hong;Smith, Theodore F.
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.19 no.11
    • /
    • pp.797-802
    • /
    • 2007
  • The effects of window cover on the performance of the plate type radiant cooling test system are studied. The cover materials tested are 2mm, 1mm, 0.7mm glass, Cokin 007 filter, and PVC film. The measurements are performed during the September nights of 2005 at the rooftop of the building in Seoul. The equivalent height of the building is about a building with twelve floors. The radiant cooling performance of the black painted and aluminum film coated plate are compared under no cover condition. Also the results are compared when the system has cover over the plate. In general, the covers reduce the radiant cooling temperature differences during the nighttime. Among these covers, the PVC film cover shows the best performance. In some cases, the plate with PVC film cover shows lower temperatures than the system without cover.