• 제목/요약/키워드: rinsing time

검색결과 66건 처리시간 0.024초

오염포의 특성과 헹구기 조건에 따른 세척 효과 (Washing Effects according to the Rinsing Conditions and the Characteristics of Soiled Fabrics)

  • 조원주;이득희;박은진;이정숙
    • 한국의류산업학회지
    • /
    • 제13권3호
    • /
    • pp.425-431
    • /
    • 2011
  • The purpose of this study was to investigate washing effects according to the rinsing conditions and the characteristics of soiled fabrics. In this study rinsing conditions including rinsing cycle, time, temperature, and bath ratio were examined. The foamability of rinsing bath was also examined. The quantity of LAS in the rinsing bath and extracts of test fabrics was analyzed after washing and rinsing, respectively. The results of these experiments were as follows: The washing effects of soiled fabrics were varied from the kinds of soils and rinsing conditions. The removal of soils from fabrics was increased by the first rinsing after washing effectively. The priorities of rinsing conditions were rinsing temperature> rinsing time > rinsing cycles> references. Foamability was result from residual LAS in rinsing bath and fabrics extracts after rinsing. The residual quantity of LAS was references > rinsing cycles> rinsing time> rinsing temperature, which shown rinsing temperature was the most efficient factor of the rinsing performance.

세척 방법 및 세척 시간에 따른 3D 프린팅 방식으로 제작된 임시 보철물의 변연 및 내면 적합도 평가 (Evaluation of Marginal and Internal Gap of Temporary Prosthesis Fabricated by 3D Printing Method According to Rinsing Method and Rinsing Time)

  • 배지현;최재원
    • 한국산업융합학회 논문집
    • /
    • 제26권4_2호
    • /
    • pp.561-570
    • /
    • 2023
  • This study was to evaluate the effect of different rinsing times and methods on the accuracy of temporary prostheses fabricated by 3D printing method. Sixty temporary prostheses were fabricated with LCD types of 3D printer(Halot-Sky, Creality, Shenzhen, China) and divided into six groups (n = 10) based on rinsing times and methods. All specimens were rinsed with 99% isopropanol alcohol for 5 and 10 min using three methods-hand washed, ultrasonic cleaning, and automated washing. All specimens were polymerized for 3 minutes under the same conditions. The marginal and internal gaps of specimens were examined using a replica technique. The light-body silicone thickness was measured at 6 reference points(Absolute marginal discrepancy, Marginal, Chamfer, Axial, Angle, and Occlusal gap). All measurements were performed by a stereomicroscope. Reference point images were taken at 100× magnification and then measured using an image analysis program. Statistical analysis was performed using Two-way ANOVA, One-way ANOVA, and the Kruskal-Wallis test (p = .05). The marginal and internal gaps were statistically different according to the rinsing methods and rinsing times(p < .001). In the rinsing time, the temporary prosthesis rinsed for 5 minutes group showed higher accuracy than 10 minutes group. In the rinsing method, the hand washing group showed higher accuracy than the automated washing group.

세척시 섬유의 음이온계 계면활성제 흡착과 헹구기 효과에 관한 연구 (A Study on the Adsorption of Anionic Surfactant by Various Textile Fibers and Rinsing Efficiency in Washing Process)

  • 박선경;김성련
    • 한국의류학회지
    • /
    • 제17권1호
    • /
    • pp.129-136
    • /
    • 1993
  • Authors have studied the adsorption of anionic surfactant from detergent solutions on cotton fabric during washing process and have measured the concentration of the residual surfactant in rinsing solution. The relations with temperature and pre-soaking time to rinsing process have been studied. The adsorption of sodium dodecylbenzene sulfonate by various textile fibers has also been investigated. The results of this study are; 1. Three times rinsing is sufficient as, without pre-soaking, the concentration of the surfactant on fabric is stable from that time on. 2. The rinsing efficiency increases with temperature; at $25^{\circ}C$, $40^{\circ}C$, and $55^{\circ}C$, the concentrations of surfactant on the fabric after-rinsing are 68, 59, 51 mg/100 g of fiber respectively. 3. The longer the pre-soaking time, the lower the rinsing efficiency is; the 4hrs presoaked fabric shows increased surfactant concentration than the one without-soaking. And the increment is 35.8%. 4. The adsorption of sodium dodecylbenzene sulfonate on fabrics differs greatly with the chemical nature of the fiber; wool, silk and nylon which are thought to be ionic-adsorbants shows greater adsorption. 5. The adsorption of surfactant is more affected by the ionic character than the physical one, and the one with higher crystallinity such as cotton and polyester shows lower value than rayon or acetate.

  • PDF

불화물도포 후 양치 시점에 따른 치면변화 (Rinsing time and enamel surface changes after fluoride application)

  • 조민정;김다은
    • 한국치위생학회지
    • /
    • 제19권1호
    • /
    • pp.151-159
    • /
    • 2019
  • Objective: This study aimed to investigate the relation between rinsing time and the change in enamel surface after fluoride application on the enamel surface. Methods: We recruited two sample groups with different mouth rinsing times. While one group rinsed the teeth immediately after applying acidulated phosphate fluoride (APF) gel, the other group rinsed the teeth 30 minutes after APF gel application. In each group, we performed the following four-step experiment: (i) apply APF gel on the teeth, (ii) rinse the teeth, (iii) immerse the teeth in orange juice, and (iv) measure enamel surface microhardness and scan enamel surfaces. Results: The group that rinsed 30 minutes after treatment exhibited greater microhardness than the group that rinsed immediately after fluoride treatment. The former also showed smooth and regular crystallization, whereas the latter showed rough and damaged crystallization and irregular surfaces. Conclusions: Based on these observations, we conclude that delaying the rinsing time improves the dental caries preventive effect of fluoride.

세탁 및 헹굼성능 향상 방안 연구 - 세제의 용해가 세탁 및 헹굼 성능에 미치는 영향 - (A study of Improvement on Washing and Rinsing Efficiency - Effect of the dissolution of detergent on washing and rinsing efficiency -)

  • 이옥기;표상연
    • 한국의류학회지
    • /
    • 제18권1호
    • /
    • pp.23-30
    • /
    • 1994
  • The objective of this study was to analyze the effect of the dissolution of detergent on washing and rinsing efficiency, and the possibility of saving detergent in washing. Washing and rinsing efficiency were reviewed in three different ways : A method was to input dissolved detergent by the use of rapid detergent dissolution instrument, B method was to input dissolved detergent beforehand, and C method was to input undissolved detergent. The results were as follows 1. A method > B method > C method was shown in detergency with washing time and three method's gaps were reduced because detergent dissolution effect was reduced by mechanical action in proportion of washing time. Especially, according to detergency of A method of 0.07% and C method of 0.1% was appeared approximately, saving detergent was expected by rapid dissolution of detergent. 2. A method > B method > C method was shown in detergency with washing temperature. As the washing temperature rose, the detergent reached chemically more activated state and become easily soluble. It resulted for the detergent to penetrate and adhere to laundry easily. 3. A method > B method > C method was shown in detergency with detergent concentration and C method was more sensitive than A, B method against change of detergent cocentration. Rapid detergent dissolution made it possible not only to enhance the washing efficiency but also to save the detergent because detergency of A method in low concentration is higher than that of C method. 4. A method $\geq$ B method > C method was shown in rinsing ratio with detergent input method. It indicated input dissolved detergent was advantageous in rinsing. 5. The result of anion surfactant concentration test of each process with detergent input method was shown like that A method In B method > C method in washing and reverse result was shown in rinsing. The anion surfactant concentration of C method was low during washing but high during rinsing. This was identical with previous results which shown the washing and rinsing efficiency improved with dissolved detergent usasge. 6. C method > B method > A method was shown in the degree of remaining detergent after rinsing. There was no remaining detergent after second rinsing in A and B method, but in C method four rinsings were required for the same result. Consequently, in A and B methods, less water and electricity were used, and less abrasion of cloth.

  • PDF

Effect of post-rinsing time and method on accuracy of denture base manufactured with stereolithography

  • Katheng, Awutsadaporn;Kanazawa, Manabu;Komagamine, Yuriko;Iwaki, Maiko;Namano, Sahaprom;Minakuchi, Shunsuke
    • The Journal of Advanced Prosthodontics
    • /
    • 제14권1호
    • /
    • pp.45-55
    • /
    • 2022
  • PURPOSE. This in vitro study investigates the effect of different post-rinsing times and methods on the trueness and precision of denture base resin manufactured through stereolithography. MATERIALS AND METHODS. Ninety clear photopolymer resin specimens were fabricated and divided into nine groups (n = 10) based on rinsing times and methods. All specimens were rinsed with 99% isopropanol alcohol for 5, 10, and 15 min using three methods-automated, ultrasonic cleaning, and hand washing. The specimens were polymerized for 30 min at 40℃. For trueness, the scanned intaglio surface of each SLA denture base was superimposed on the original standard tessellation language (STL) file using best-fit alignment (n = 10). For precision, the scanned intaglio surface of the STL file in each specimen group was superimposed across each specimen (n = 45). The root mean square error (RMSE) was measured, and the data were analyzed statistically through one-way ANOVA and Tukey test (α < .05). RESULTS. The 10-min automated group exhibited the lowest RMSE. For trueness, this was significantly different from specimens in the 5-min hand-washed group (P < .05). For precision, this was significantly different from those of other groups (P < .05), except for the 15-min automated and 15-min ultrasonic groups. The color map results indicated that the 10-min automated method exhibited the most uniform distribution of the intaglio surface adaptation. CONCLUSION. The optimal postprocessing rinsing times and methods for achieving clear photopolymer resin were found to be the automated method with rinsing times of 10 and 15 min, and the ultrasonic method with a rinsing time of 15 min.

디지털 광 조명 방식으로 제작한 임시 크라운의 세척 시간에 따른 3차원 적합도 평가 (Comparison of three-dimensional adaptation as per the rinsing time of temporary crown manufactured using a digital light processing printer)

  • 이범일;유승규;유승민;김지환
    • 대한치과기공학회지
    • /
    • 제42권4호
    • /
    • pp.334-340
    • /
    • 2020
  • Purpose: This study aimed to compare three-dimensional adaptation with the rinsing time of the temporary crown produced using the digital light processing method. Methods: The maxillary right first molar abutment was scanned with a dental scanner. A temporary crown was designed with the scanned abutment. The designed crown was made of 10 temporary crowns using a digital light processing printer. The crowns were divided into the 5-minute and 10-minute rinsing groups; 5 temporary crown washes were performed for each group. In order to obtain the internal data, each group was scanned for a temporary crown. The three-dimensional fit was measured by superimposing the scanned internal surface data and the abutment data. The average comparison of three-dimensional adaptation was analyzed using the Mann-Whitney U test. Results: The 5-minute rinsing group showed a significantly higher adaptation of 71.42±3.08 ㎛ as compared to the 10-minute rinsing group (67.52±0.92 ㎛) (p<0.05). Conclusion: When making a temporary crown with a digital light processing method, a rinsing time of 10 minutes is appropriate.

Effect of Rinsing after Mordanting on the Air-permeability and Dyeing of Fabrics with Cochineal Dyestuff

  • Na, Ho-Jin;Jeon, Dong-Won;Kim, Jong-Jun
    • 패션비즈니스
    • /
    • 제8권6호
    • /
    • pp.137-145
    • /
    • 2004
  • According to the experimental results, it has been reported by several researchers that the air-permeability values of the fabrics mostly decreased by the mordanting during the dyeing procedure. The exact quantitative information, however, has not been presented so far. In this study, the change of the fabric air-permeability was investigated quantitatively. At the same time, the change of the fabric air-permeability according to the dyeing procedure. In order to investigate the possibility of the detachment of the metal ions on the fiber or fabric surface, the change of the air-permeability was investigated after several rinsing of the mordanted fabrics. By comparing the color differences of the cochineal dyed fabrics which were subjected to rinsing procedure after mordanting, the effect of the rinsing of the mordanted fabrics on the dyeing of fabrics was investigated. At the range of mordant concentration, 2% Cu, 2% Sn, 2% Fe, 2% Cr, 5% Al, the metal ions are not excessively absorbed on the fiber surface. Also, any remarkable detachment of the metal ions does not accompany after the mordanting with the subsequent rinsing procedure.

반도체 노광 공정의 DI 세정과 Oxide의 HF 식각 과정이 실리콘 표면에 미치는 영향 (Effects of DI Rinse and Oxide HF Wet Etch Processes on Silicon Substrate During Photolithography)

  • 백정헌;최선규;박형호
    • 한국재료학회지
    • /
    • 제20권8호
    • /
    • pp.423-428
    • /
    • 2010
  • This study shows the effects of deionized (DI) rinse and oxide HF wet etch processes on silicon substrate during a photolithography process. We found a fail at the wafer center after DI rinse step, called Si pits, during the fabrication of a complementary metal-oxide-semiconductor (CMOS) device. We tried to find out the mechanism of the Si pits by using the silicon wafer on CMOS fabrication and analyzing the effects of the friction charge induced by the DI rinsing. The key parameters of this experiment were revolution per minute (rpm) and time. An incubation time of above 10 sec was observed for the formation of Si pits and the rinsing time was more effective than rpm on the formation of the Si pits. The formation mechanism of the Si pits and optimized rinsing process parameters were investigated by measuring the charging level using a plasma density monitor. The DI rinse could affect the oxide substrate by a friction charging phenomenon on the photolithography process. Si pits were found to be formed on the micro structural defective site on the Si substrate under acceleration by developed and accumulated charges during DI rinsing. The optimum process conditions of DI rinse time and rpm could be established through a systematic study of various rinsing conditions.

Effect of rinsing time on the accuracy of interim crowns fabricated by digital light processing: An in vitro study

  • Lee, Beom-Il;You, Seung-Gyu;You, Seung-Min;Kang, Seen-Young;Kim, Ji-Hwan
    • The Journal of Advanced Prosthodontics
    • /
    • 제13권1호
    • /
    • pp.24-35
    • /
    • 2021
  • PURPOSE. This study was to evaluate the effect of rinsing time on the accuracy of interim crowns fabricated by digital light processing. MATERIALS AND METHODS. The maxillary right first molar master die was duplicated using a silicone material, while a study die was produced using epoxy resin. Scans of the epoxy resin die were used in combination with CAD software to design a maxillary right first molar interim crown. Based on this design, 24 interim crowns were fabricated with digital light processing. This study examined the trueness and precision of products that were processed with one of the three different postprocessing rinsing times (1 min, 5 min, and 10 min). Trueness was measured by superimposing reference data with scanned data from external, intaglio, and marginal surfaces. Precision was measured by superimposing the scan data within the group. The trueness and precision data were analyzed using Kruskal-Wallis, nonparametric, and post-hoc tests, and were compared using a Mann-Whitney U test with Bonferroni correction (α=.05). RESULTS. The trueness of the external and intaglio surfaces of crowns varied significantly among the different rinsing times (P=.004, P=.003), but there was no statistically significant difference in terms of trueness measurements of the marginal surfaces (P=.605). In terms of precision, statistically significant differences were found among the external, intaglio, and marginal surfaces (P=.001). CONCLUSION. Interim crowns rinsed for 10 minutes showed high accuracy.