• 제목/요약/키워드: reversing performance

검색결과 19건 처리시간 0.026초

Robust Design of Main Control Valve for Hydraulic Pile Hammer Flexible Control System

  • Guo, Yong;Hu, Jun Ping;Zhang, Long Yan
    • International Journal of Fluid Machinery and Systems
    • /
    • 제9권1호
    • /
    • pp.28-38
    • /
    • 2016
  • The flexible control system for hydraulic pile hammer using main control valve is present to the requirement of rapidly reversing with high frequency. To ensure the working reliability of hydraulic pile hammer, the reversing performance of the main control valve should commutate robustness to various interfere factors. Through simulation model built in Simulink/Stateflow and experiment, the effects of relative parameters to reverse performance of main control are analyzed and the main interfere factors for reversing performance are acquired. Treating reverse required time as design objects, some structure parameters as control factors, control pressure, input flow and gaps between spool and valve body as interfere factors, the robust design of the main control valve is done. The combination of factors with the strongest anti-jamming capability is acquired which ensured the reliability and anti-jamming capability of the main control valve. It also provides guidance on design and application of the main control valve used in large flow control with interferes.

이기종 셀룰러 네트워크에서 펨토셀 성능향상을 위한 상향링크 간섭 회피 기법 (Uplink Interference Avoidance Scheme to Improve Femtocell Performance in Heterogeneous Cellular Networks)

  • 권중형;상영진;김광순
    • 한국통신학회논문지
    • /
    • 제38A권5호
    • /
    • pp.451-458
    • /
    • 2013
  • 본 논문에서는 단일 주파수 이기종 셀룰러 네트워크에서 매크로셀 사용자로 인해 발생하는 간섭을 회피하여 펨토셀 상향링크 성능을 향상시키는 기법을 제안한다. 매크로셀 사용자가 펨토셀 기지국 주변에 존재할 경우 매크로셀 사용자의 송신 전력이 펨토셀에 심각한 간섭으로 영향을 주어 펨토셀 상향링크 성능이 열화된다. 이러한 문제점을 해결하기 위하여 본 논문에서는 매크로셀 사용자로 부터 극심한 간섭을 받는 펨토셀 기지국은 상하향링크 프레임 위치를 서로 변경한 뒤, 매크로셀 사용자의 데이터를 중계 기법을 통하여 매크로셀 기지국으로 전송하는 기법을 제안한다. 제안한 방식의 펨토셀 상향링크 시간 동안 펨토셀과 매크로셀 사용자가 시간을 나누어 펨토셀 기지국으로 전송하고 하향링크 시간 동안 중첩 부호화 기술을 사용하여 펨토셀 사용자와 매크로 사용자의 데이터를 동시에 전송하게 된다. 본 논문에서는 모의실험을 통하여 제안한 방식이 펨토셀 상하향링크의 성능개선에 효과가 있음을 확인할 수 있다.

강판의 자동 형상제어 장치의 특성에 관한 연구 (A Study on the Characteristics of Automatic Flatness Control System for Stell Sheet)

  • 김순경;전연찬;김중완;김문경
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 1996년도 춘계학술대회 논문집
    • /
    • pp.541-545
    • /
    • 1996
  • In this paper, The performance and functions of automatic flatness control system installed on the 4 hi-reversing mill and has been investigated under actualconditions. A new automatic flatness control system incorporates a measuring roll for measurement and correction calculations, hydraulic roll benders, selective roll cooling, and a programmable controller for interface and data logging. The test results are as following. The more the exit steel strip thickness is thick, the smaller the I value, and the more it is thin, the larger the I value. And, a complex distribution of strip tension was controlled, for example, not only a quarter buckle but also a simple center wave and edge wave. Because the tension deviation is larger at acceleration speed and deceleration speed than steady speed, so automatic flatness control system of contact type is better to adopt over 450 m/min, automatic flatness control system reduces rapidly large flatness deviation. The maximum I value of strip has been decreased to 13 I, and defects caused by poor flatness have been drastically decreased. And coolant temperature for work roll cooling system on the automatic flatness control system is better to adopt about 50-55 .deg. C.

  • PDF

냉각압연 가공용 자동 형상제어장치의 특성에 관한 연구 (A Study on the Characteristics of Automatic Flatness Control System for Cold Rolling)

  • 김문경;전언찬;김순경
    • 대한기계학회논문집A
    • /
    • 제20권9호
    • /
    • pp.2901-2907
    • /
    • 1996
  • Flatness of cold rolled strip is vital to the quality of the product and productivity of the mill. Therefore, in recent year requirement for flatness control in strip rolling have become increasingly severe. The necessity for more accurate automatic gauge control and automatic flatness control(AFC) has increased by customer's requirement for cold rolled steel sheets with thinner gauge and better flatness quality. In this paper, the performance and functions of AFC system installed on the 4 hi-reversing mill has been investigated under actual conditions. The test results are as follows : The more strip thickness is thick, the smaller the I-value. The I-value is a strain measured by stressometer. Complex distributions of strip tension are controlled to remove not only a quarter buckle but also a simple center wave and edge wave. The defects caused by poor flatness have been drastically decreased. And a proper coolant temperature for work roll cooling system on the AFC system is about $50~55^{\circ}C$.

Ship nonlinear-feedback course keeping algorithm based on MMG model driven by bipolar sigmoid function for berthing

  • Zhang, Qiang;Zhang, Xian-ku;Im, Nam-kyun
    • International Journal of Naval Architecture and Ocean Engineering
    • /
    • 제9권5호
    • /
    • pp.525-536
    • /
    • 2017
  • Course keeping is hard to implement under the condition of the propeller stopping or reversing at slow speed for berthing due to the ship's dynamic motion becoming highly nonlinear. To solve this problem, a practical Maneuvering Modeling Group (MMG) ship mathematic model with propeller reversing transverse forces and low speed correction is first discussed to be applied for the right-handed single-screw ship. Secondly, a novel PID-based nonlinear feedback algorithm driven by bipolar sigmoid function is proposed. The PID parameters are determined by a closed-loop gain shaping algorithm directly, while the closed-loop gain shaping theory was employed for effects analysis of this algorithm. Finally, simulation experiments were carried out on an LPG ship. It is shown that the energy consumption and the smoothness performance of the nonlinear feedback control are reduced by 4.2% and 14.6% with satisfactory control effects; the proposed algorithm has the advantages of robustness, energy saving and safety in berthing practice.

Implementation of Multilevel Boost DC-Link Cascade based Reversing Voltage Inverter for Low THD Operation

  • Rao, S. Nagaraja;Kumar, D.V. Ashok;Babu, Ch. Sai
    • Journal of Electrical Engineering and Technology
    • /
    • 제13권4호
    • /
    • pp.1528-1538
    • /
    • 2018
  • In this paper, configuration of $1-{\phi}$ seven-level boost DC-link cascade based reversing voltage multilevel inverter (BDCLCRV MLI) is proposed for uninterrupted power supply (UPS) applications. It consists of three level boost converter, level generation unit and full bridge circuit for polarity generation. When compared with conventional boost cascaded H-bridge MLI configurations, the proposed system results in reduction of DC sources, reduced power switches and gate drive requirements. Inverter switching is accomplished by providing appropriate switching angles that is generated by any optimization switching angle techniques. Here, round modulation control (RMC) method is taken as the optimization method and switching angles are derived and the same is compared with various switching angles methods i.e., equal-phase (EP) method, and half-equal-phase (HEP) method which results in improved quality of obtained AC power with lowest total harmonic distortion (THD). Reduction in DC sources and switch count makes the system more cost effective. A simulation and prototype model of $1-{\phi}$ seven-level BDCLCRV MLI system is developed and its performance is analyzed for various operating conditions.

건표고 자동 등급선별 시스템 개발 -시작 2호기- (Development of Automatic Grading and Sorting System for Dry Oak Mushrooms -2nd Prototype-)

  • 황헌;김시찬;임동혁;송기수;최태현
    • Journal of Biosystems Engineering
    • /
    • 제26권2호
    • /
    • pp.147-154
    • /
    • 2001
  • In Korea and Japan, dried oak mushrooms are classified into 12 to 16 different categories based on its external visual quality. And grading used to be done manually by the human expert and is limited to the randomly sampled oak mushrooms. Visual features of dried oak mushrooms dominate its quality and are distributed over both sides of the gill and the cap. The 2nd prototype computer vision based automatic grading and sorting system for dried oak mushrooms was developed based on the 1st prototype. Sorting function was improved and overall system for grading was simplified to one stage grading instead of two stage grading by inspecting both front and back sides of mushrooms. Neuro-net based side(gill or cap) recognition algorithm of the fed mushroom was adopted. Grading was performed with both images of gill and cap using neural network. A real time simultaneous discharge algorithm, which is good for objects randomly fed individually and for multi-objects located along a series of discharge buckets, was developed and implemented to the controller and the performance was verified. Two hundreds samples chosen from 10 samples per 20 grade categories were used to verify the performance of each unit such as feeding, reversing, grading, and discharging unites. Test results showed that success rates of one-line feeding, reversing, grading, and discharging functions were 93%, 95%, 94%, and 99% respectively. The developed prototype revealed successful performance such as the approximate sorting capability of 3,600 mushrooms/hr per each line i.e. average 1sec/mushroom. Considering processing time of approximate 0.2 sec for grading, it was desired to reduce time to reverse a mushroom to acquire the reversed surface image.

  • PDF

터보펌프의 속도복식 터빈에 대한 성능 연구 (Experimental Study of the Velocity Compound Turbine in Turbopump)

  • 이항기;정은환;박편구;김진한
    • 한국추진공학회:학술대회논문집
    • /
    • 한국추진공학회 2011년도 제37회 추계학술대회논문집
    • /
    • pp.38-44
    • /
    • 2011
  • 75톤급 액체로켓엔진용 터보펌프에 장착되는 속도복식 터빈에 대한 성능 시험을 수행하였다. 1열 로터와 리버싱 베인 사이에 누설 유량을 줄이는 씰을 설치하여 씰 간극이 성능에 미치는 영향을 실험하였다. 그리고 속도복식 터빈과 단단으로 구성된 기본형 터빈을 비교하여 회전수에 따른 후방 압력 변화와 함께 성능에 미치는 영향을 살펴보았다.

  • PDF

QoS Based Routing Algorithm with Crank-Back Ability

  • Kanthavong, Somphone;Tangtisanon, Prakit;Lertwatechakul, Mayuree
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 2003년도 ICCAS
    • /
    • pp.2413-2417
    • /
    • 2003
  • This paper proposes an improvement of a QoS based routing protocol. The hierarchical source routing algorithm[4] was improved by including of the Crank-Back algorithm[2]. The Crank-Back capability is the ability to solve the problem of selecting the wrong route because of using unsynchronized routing information in the ingress router. In order to reduce time of reversing the call-setup process back to the ingress router, spare-route information is included with a call-setup packet. Spare-route information could be used by every router to find the next appropriated link itself when insufficient resource of the selected link was found. The proposed algorithm improves the performance of the source routing call-setup process significantly.

  • PDF

A Comparative Study of Two-phase Heuristic Approaches to General Job Shop Scheduling Problem

  • Sun, Ji Ung
    • Industrial Engineering and Management Systems
    • /
    • 제7권2호
    • /
    • pp.84-92
    • /
    • 2008
  • Scheduling is one of the most important issues in the planning and operation of production systems. This paper investigates a general job shop scheduling problem with reentrant work flows and sequence dependent setup times. The disjunctive graph representation is used to capture the interactions between machines in job shop. Based on this representation, four two-phase heuristic procedures are proposed to obtain near optimal solutions for this problem. The obtained solutions in the first phase are substantially improved by reversing the direction of some critical disjunctive arcs of the graph in the second phase. A comparative study is conducted to examine the performance of these proposed algorithms.