• Title/Summary/Keyword: reuse of the effluent

Search Result 130, Processing Time 0.025 seconds

Performance Evaluation of the Serially Connected Two Stage Fiber Filter for the RO Membrane Pre-treatment (2단 섬유여과 공정의 역삼투막 전처리 성능평가)

  • Bae, Si-Youl;Yun, Chang-Han;Kang, Dong-Hyo
    • Membrane Journal
    • /
    • v.19 no.2
    • /
    • pp.165-171
    • /
    • 2009
  • This study was for the evaluation of adaptability of the fiber filter as the pre-treatment of the RO membrane through SDI (Silt Density Index) measurement. The turbidity of raw waters were $0.76{\sim}1.6$ NTU for the effluent of sewer treatment plants (STP) and $2.2{\sim}3.3$ NTU for sea waters and 100 NTU for the surface water. The turbidity of the $2^{nd}$ filtrate of the serially connected two fiber filters was $0.07{\sim}0.25$ NTU and $SDI_{15}$ was $1.4{\sim}2.8$ when the 17% PAC was dosed $10{\sim}30ppm$. Results of the turbidity and $SDI_{15}$ of the $2^{nd}$ filtrate of the fiber filter which were compared with them of the lab scale MF/UF disc filter for the same STP's effluents showed that filtrate quality were enhanced with a little on the order of two stage fiber filter>MF>UF, the difference in $SDI_{15}$ was only $0.7{\sim}1.0$. So, the filtrate of the serially connected two stage fiber filter could satisfy $SDI_{15}$ 5.0 safely which was normally required for the feed water by the RO membrane supplier and it means the serially connected two stage fiber filter could be applied as the pre-treatment process of the RO membrane.

Trace-level Determination of N-nitrosodimethylamine(NDMA) in Water Samples using a High-Performance Liquid Chromatography with Fluorescence Derivatization (HPLC와 Fluorescence Derivatization 기법을 이용한 극미량 NDMA의 수질분석)

  • Cha, Woo-Suk;Fox, Peter;Nalinakumari, Brijesh;Choi, Hee-Chul
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.28 no.2
    • /
    • pp.223-228
    • /
    • 2006
  • High-performance liquid chromatography(HPLC) and fluorescence derivatization were applied for a trace-level N-nitrosodimethylamine(NDMA) analysis of water samples. Fluorescence intensity was optimized with the excitation wavelength of 340 nm and the emission wavelength of 530 nm. pH adjustment after denitrosation was necessary to get a maximum intensity at pH between 9 and 12. Maximum intensity was found with a dansyl chloride concentration of 330 to 500 mg/L. Percentile error in the water sample analyses through solid phase extraction was 12-162% and 6-23% for the lower concentration level(10-200 ng/L NDMA) and the higher level(100-1000 ng/L NDMA), respectively, showing more discrepancy in lower level. However, the average ratios of estimated NDMA to the standard NDMA were close to 1 for both concentration ranges, presenting this HPLC method could detect from tens to hundreds nanograms NDMA per liter. Accurate determination of NDMA, which was injected to a wastewater effluent, revealed the selectivity of fluorescence derivatization for the target compound(NDMA) in the presence of complex interfering compounds. The HPLC with fluorescence derivatization may be applicable for determining NDMA of water and wastewater samples fur various research purposes.

Application in Membrane Hybrid System with Acrylic Wastewater Pretreated by $TiO_2$ ($TiO_2$로 전처리한 아크릴 폐수의 Membrane Hybrid System에의 적용)

  • Lee, Kwang-Hyun;Kang, Byung-Chul;Lee, Jong-Baek;Lee, Gang-Choon
    • Membrane Journal
    • /
    • v.19 no.3
    • /
    • pp.183-188
    • /
    • 2009
  • After membrane fouling factors in acrylic wastewater were minimized by pretreatment process accompanied with $TiO_2$, it was utilized in MF/UF/RO process. After composing of ultrafiltration/reverse osmosis or microfiltration/reverseosmosiss module set according to types and kinds of membrane, the separation characteristics were examined with the variation temperature and pressure using pretreated acrylic wastewater by membrane module sets. The permeate of ultrafiltration or microfiltration module was sent to reverse osmosis module. It was found that final permeate flux of reverse osmosis module in module set 2 (MWCO 200,000 UF+RO) was excellent. It was shown that the removal efficiency of TDS, T-N and COD was very low and was not dependent on the variation of temperature and pressure in UF and MF modules. From the above result, the removal efficiency of TDS, T-N and COD was very excellent in RO module. The removal efficiency of turbidity in UF and MF module was very high (> 99% removal efficiency). Final water quality of acrylic wastewater treated by the membrane module set was satisfied with effluent allowances limit and membrane module sets were ascertained to reuse wastewater.

Applicability Investigation of E.coli, RNA and DNA Bacteriophages for Possible Indicator Microorganisms Based on the Inactivation Effectiveness by UV (UV 불활성화 효과에 의거한 E.coli, RNA 및 DNA 박테리오파지의 대체 지표 미생물로서의 적용성 검토)

  • Kim, Il-Ho;Wahid, Marfiah AB;Tanaka, Hiroaki
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.32 no.11
    • /
    • pp.1063-1068
    • /
    • 2010
  • This study compared UV and UV/$H_2O_2$ inactivation of E.coli, a possible indicator microorganism for fecal contamination of water, and $Q{\ss}$ phage, an indicator for pathogenic viruses. UV inactivation of $Q{\ss}$, T4 and lambda phages in actual secondary effluent was investigated, too. As a result, similar inactivation efficiency between $Q{\ss}$ phage and E.coli was observed during UV treatment, while $Q{\ss}$ phage showed higher resistance to UV/$H_2O_2$ than E.coli. $Q{\ss}$ phage resistance to UV or UV/$H_2O_2$ does not reflect those of all pathogenic viruses. However, the result tells that the use of E.coli inactivation efficiency in evaluating microbiological safety of water could not always ensure the sufficient safety from pathogenic viruses. Meanwhile, $Q{\ss}$ phage showed less resistance to UV than T4 and lambda phages, indicating that the use of $Q{\ss}$ phage as an indicator virus may bring insufficient disinfection effectiveness by causing the introduction of lower UV dose than required. Consequently, it can be thought that T4 or lambda phages would be more desirable indicators in ensuring the sufficient disinfection effectiveness for various pathogenic viruses.

Effects of Environmental Infrastructure Regeneration in Urban Region - A Case Study of M Apartment Complex in Daejeon (도시 단지내 환경 인프라 재생 효과 고찰 - 대전시 M 아파트 단지 사례연구)

  • Park, Kiyong;Choi, Changkyoo;Shin, Jongseok;Park, Heekyeng
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.35 no.2
    • /
    • pp.353-359
    • /
    • 2015
  • This study introduces a resource recycling system in urban apartment complex using four different technologies. The four technologies, called 4G, include a production technology for reclaimed water (Green water), a biogas production technology from organic waste (Green biogas), a reuse technology of rainwater (Green rainwater), and urban agropark (Green pyramid). Green water is the technology for producing the reclaimed water from wastewater, rainwater and underground water, and the average concentrations of BOD, SS, T-N and coliform of reclaimed water were 7.8mg/L, ND (not detected), 4.9mg/L and ND, respectively. Green biogas is the technology for producing biogas and effluent after treating organic wastes (e.g. food waste and night soil) discharged from households, and the average production rates of hydrogen and methane were $0.33m^3/m^3/d$ and $0.24m^3/m^3/d$, respectively. Green pyramid, agricultural farm operated by biogas and reclaimed water, provides a healthy and recreational space for residents, and plant growth rates using treated water and reclaimed water showed height of 1.32cm and weight of 112.8g. Therefore, 4G technologies can improve the recycling rate and treatment efficiencies of waste and wastewater in an apartment complex.

Effectiveness Analysis of Alternatives for Water Resources Management Considering Climate Change and Urbanization (기후변화 및 도시화를 고려한 수자원관리 대안의 효과 분석)

  • Park, Kyung-Shin;Chung, Eun-Sung;Kim, Sang-Ug;Lee, Kil-Seong
    • Journal of Korea Water Resources Association
    • /
    • v.42 no.12
    • /
    • pp.1103-1111
    • /
    • 2009
  • This study derived the analysis results of alternatives for integrated watershed management under urbanization and climate change scenarios. Climate change and urbanization scenarios were obtained by using SDSM (Statistical Downscaling Method) model and ICM (Impervious Cover Model), respectively. Alternatives for the Anyangcheon watershed are reuse of wastewater treatment plant effluent, and redevelopment of existing reservoir. Flow and BOD concentration duration curves were derived by using HSPF (Hydrological Simulation Program - Fortran) model. As a result, low flow ($Q_{99},\;Q_{95},\;Q_{90}$) and BOD concentration ($Q_{10},\;Q_5,\;Q_1$) were very sensitive to the alternatives comparing to high flow($C_{30},\;C_{10},\;C_1$). Although urbanization makes the hydrological cycle distorted, effective alternatives can reduce its damage. The numbers of days to satisfy the instreamflow requirements and target water quality were also sensitive to urbanization. This result showed that the climate change and urbanization should be considered in the water resources/watershed and environmental planning.

An Economic Analysis of the Effluent Heat Supply from Thermal Power Plant to the Farm Facility House (화력발전소 온배수열 활용 시설하우스 열공급 모형 경제성분석 연구)

  • Um, Byung Hwan;Ahn, Cha Su
    • Korean Chemical Engineering Research
    • /
    • v.56 no.1
    • /
    • pp.6-13
    • /
    • 2018
  • Utilizing the heat of cooling water discharge of coal-fired power plant, pipeline investment costs for businesses that supply heat to agricultural facilities near power plants increase in proportion to installation distance. On one hand, the distance from the power plant is a factor that brings difficulties to secure economic efficiency. On the other, if the installation distance is short, there is a problem of securing the heating demands, facility houses, which causes economical efficiency to suffer. In this study, the economic efficiency of 1km length of standard heat pipeline was evaluated. The sensitivity of the heat pipe to the new length variation was analyzed at the level of government subsidy, amount of heating demand and the incremental rate of pipeline with additional government subsidy. As a result of the analysis, it was estimated that NPV 131 million won and IRR 15.73%. The sensitivity analysis showed that NPV was negative when the length of heat pipe facility exceeded 2.6 km. If the government supports 50% of the initial investment, the efficiency is secured within the estimated length of 5.3 km, and if it supports 80%, the length increases within 11.4 km. If the heat demand is reduced to less than 62% at the new length of the standard heat pipe, it is expected economic efficiency is not obtained. If the ratio of government subsidies to initial investment increases, the elasticity of the new bloc will increase, and the fixed investment, which is the cost of capital investment for one unit of heating demand, will decrease. This would result in a reduction in the cost of production per unit, and it would be possible to supply heat at a cheaper price level to the facility farming. Government subsidies will result in the increased economic availability of hot plumbing facilities and additional efficiencies due to increased demand. The greater government subsidies to initial investment, the less farms cost due to the decrease in the price per unit. The results of the study are significant in terms of the economic evaluation of the effectiveness of the government subsidy for the thermal power plant heat utilization project. The implication can be applied to any related pilot to come.

Calcium Removal from Effluent of Electronics Wastewater Using Hydrodynamic Cavitation Technology (수리동력학적 캐비테이션을 이용한 전자폐수 처리수에 함유된 칼슘저감에 관한 연구)

  • Park, Jin-Young;Kim, Sun-Jip;Lee, Yong-Woo;Lee, Jae-Jin;Hwang, Kyu-Won;Lee, Won-Kwon
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.29 no.6
    • /
    • pp.715-721
    • /
    • 2007
  • Residual calcium concentration is high, in general, at the effluent of the fluoride removal process in the electronics industry manufacturing semiconductor and LCD. To increase the stability of the membrane process incorporated for reuse of wastewater, the residual calcium is required to be pre-removed. Hyperkinetic Vortex Crystallization(HVC) process was installed in the electronics industry manufecturing semi conductor as a pilot scale for accelerating calcification of calcium ion. Compared to the conventional soda ash method, the 31% higher calcium removal efficiency was achieved when HVC was applied at the same sodium carbonate dosage. In order to maintain the economic calcium removal target of 70% preset by manufacturer, the dosing concentration of the soda ash was 530 mg/L based on influent flowrate. The seed concentration in the reactor was one of the critical factors and should be maintained in the range of $800\sim1,200mg$ SS/L to maximize the calcium removal efficiency. The calcite production rate was 0.30 g SS/g $Na_2CO_3$ in the average. The economic HVC passing time of the mixture was in the range of $2\sim5$ times. Relatively, stable calcium concentration was maintained in the range of $30\sim72$ mg/L(average 49 mg/L) although the calcium concentration in the feed was severely fluctuated with $74\sim359$ mg/L(average 173 mg/L). The HVC process was characterized as environment-friendly technology reducing chemical dosage and chemical sludge production and minimizing maintenance cost.

The Effect of Reclaimed Sewage Irrigation on the Rice Cultivation (벼 재배시 생활오수 처리수 관개 효과)

  • Yoon, Chun-Gyeong;Kwun, Soon-Kuk;Chung, Ill-Min;Kwon, Tae-Young
    • Korean Journal of Environmental Agriculture
    • /
    • v.18 no.3
    • /
    • pp.236-244
    • /
    • 1999
  • A feasibility study was performed to examine the agronomic application of treated sewage on paddy rice culture by field experiment. The domestic sewage was treated by the constructed wetland system which was in subsurface flow type and consisted of sand and macrophyte. The effluent of the wetland system was adjusted to maintain the total nitrogen concentration below $25mgL^{-1}$ and used for irrigation water. Four treatments include (1) irrigation of treated sewage after concentration adjusted with conventional fertilization (TWCF), (2) irrigation of treated sewage after concentration adjusted with half of the conventional fertilization (TWHF), (3) irrigation of treated sewage after concentration adjusted without fertilization (TWNF), and (4) irrigation of treated sewage as it was without fertilization (SWNF). These cases were compared to the control case of tap water irrigation with conventional fertilization (Control). Generally, addition of the treated sewage to the irrigation water showed no adverse affect on paddy rice culture, and even improvement was noticed in both growth and yields. TWCF showed the best result and the yields exceed the Control in about 10%. Overall performance of the treatments was TWCF, Control, TWHF, TWNF, and SWNF in decreasing order. From this study, it appears that reuse of treated sewage as a supplemental irrigation water could be feasible and practical alternative for ultimate sewage disposal which often causes water quality problem to the receiving water body. For full scale application, further study is recommended on the specific guidelines of major water quality components and public health.

  • PDF

Developments of Water Treatment System by Biological Fluidized Bed for Water Reuse Aquaculture (생물학적 유동층을 이용한 어류양식 순환수의 처리씨스템 개발)

  • LEE Ki-Wan
    • Korean Journal of Fisheries and Aquatic Sciences
    • /
    • v.26 no.4
    • /
    • pp.380-391
    • /
    • 1993
  • The experimental study was made to propose the treatment method of wastewater in the high-density fish culture system. The BOD to COD ratios of effluents were almost same to 0.65 in the eel-farm, but were various in the farm rearing together with tilapia etc. A BOD rate curve of the eel-farm effluent could be described mathematically by the equation, $BODu=14.1(1-10^{-0.222t})+30.9(1-10^{-0.035(t-8)})$. Nitrification in Biological Fluidized Bed(BFB) system to treat the fish-farm wastewater could be reduce ammonium level up to $65{\sim}79\%$ when ammonium loading rates were between 0.014 and 0.075g $NH_4/g$ BVS-day. Nitrification efficiency was decreased by organic matters in the wastewater when ammonium loading was low(0.014 g $NH_4/g$ BVS-day). T-N removal ratios were decreased to increase loading in denitrification process, because of low C/N ratio. Based on much higher biological mass concentrations, BFB system takes many advantages of a practical viewpoint, such as stability of treatment efficiency and reduction of necessary site area for the facility, as compared with conventional treatment systems.

  • PDF