Experiment for the Improvement of Fire Resistance Capacity of Reinforced Concrete Flexural Member Strengthened with Carbon Fiber Reinforced Polymer (CFRP로 보강된 철근콘크리트 휨부재의 내화성능 개선을 위한 실험)

  • Lim, Jong-Wook;Seo, Soo-yeon;Song, Se-Ki
    • Journal of the Architectural Institute of Korea Structure & Construction
    • /
    • v.33 no.12
    • /
    • pp.19-27
    • /
    • 2017
  • This paper is a study to improve the fire-resistance capacity of reinforced concrete (RC) members strengthened by fiber-reinforced-polymer (FRP). The fire resistance of the RC members strengthened by FRP was evaluated through high temperature exposure test. In order to improve the fire resistance of the FRP reinforcing method, a fire-proof board was attached to the reinforced FRP surface and then the high temperature exposure test was carried out to evaluate the improvement of the fire resistance performance. It was confirmed that the resistance to high temperature of NSMR could be improved somewhat compared with that of EBR from the experiment that exposed to high temperature under the load corresponding to 40% of nominal strength. When 30 mm thick fire-resistance (FR) board is attached to the FRP surface, the surface of the reinforced FRP does not reach $65^{\circ}C$, which is the glass transition temperature (GTT) of the epoxy until the external temperature reaches $480^{\circ}C$. In particular, when a high performance fire-proof mortar was first applied prior to FR board attachment, the FRP portion did not reach the epoxy glass transition temperature until the external temperature reached $600^{\circ}C$.

Experimental Study on the Development of a Seismic Reinforcement Method for Reinforced Concrete Columns using High-tensile Alloy Materials (고인장 합금재를 활용한 철근콘크리트 기둥의 내진보강공법 개발에 관한 실험적 연구)

  • Do-Yeon Kim;Il-Young Jang
    • Journal of the Society of Disaster Information
    • /
    • v.20 no.2
    • /
    • pp.411-418
    • /
    • 2024
  • Purpose: This study aims to develop brand new bolt fastening type of seismic retrofit using high tensile alloy materials for existing reinforced concrete columns. Method: A T-type cross-sectional seismic retrofit made of SUS304 and SS275, and the high-tensile bolt of SCM435 was analyzed for the effect of material properties on seismic performance through bending test. Result: The experiment using SUS304 shows a 7% higher maximum strength and 22% higher yield strength and shows a higher compressive stress of 360MPa. In addition, the change in the neutral axis is also smaller. Conclusion: Seismic retrofit using SUS304 is considered to be better in terms of yield strength, tensile strength, neutral axis change, and ductility, and it is considered necessary to experiment with RC column real experiments in future studies.

Comparison of different distributions of viscous damper properties in asymmetric-plan frames

  • Landi, Luca;Molari, Andrea;Diotallevi, Pier Paolo
    • Earthquakes and Structures
    • /
    • v.18 no.2
    • /
    • pp.233-248
    • /
    • 2020
  • In this article, one of the procedures to design viscous dampers proposed in literature is applied to 3D asymmetric-plan buildings, considering different distributions for the damping coefficients, which are assumed to be proportional to specific structural or response parameters. The main purpose was to investigate the effectiveness of different vertical and in-plan distributions of the damping coefficients of nonlinear viscous dampers for the seismic retrofit of existing buildings. For comparison purposes, all the distributions were applied utilizing both a simplified and an extended method for the 3D structures, where the simplified method takes into account only the translation in the seismic direction, and the extended method considers the translations along the two orthogonal directions together with the floor rotations. The proposed distributions were then applied to a typical case study involving an asymmetric-plan six-storey RC building. The effectiveness of the different distributions was examined through time-history analyses, assuming nonlinear behaviour for both the viscous dampers and the structural elements. The results of the nonlinear dynamic analyses were examined in terms of maximum and residual inter-storey drifts, peak floor accelerations and maximum damper forces.

A study on the safety LED lamp using internal control gear as the alternative type of fluorescent lamp (형광램프 대체 컨버터 내장형 LED램프의 안전성 확보방안)

  • Ko, Jae-jun;Kim, Chung-hyeok
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.29 no.3
    • /
    • pp.30-38
    • /
    • 2015
  • As products using LEDs are developed actively, also there has been large request for LED products that can replace traditional lamps like fluorescent lamps and metal halide lamps. But so far there is no proper standard that manufacturer can use and test it. As a result manufacturer can't develop retrofit LED lamps and sell it even they have technology. In this study, by analyzing control gear for fluorescent lamp that is currently used in market which is magnetic or electronic ballast, I'd like to develop proper test method by investigating compatibility between all-type control gear and LED retrofit products.

Single and multi-material topology optimization of CFRP composites to retrofit beam-column connection

  • Dang, Hoang V.;Lee, Dongkyu;Lee, Kihak
    • Computers and Concrete
    • /
    • v.19 no.4
    • /
    • pp.405-411
    • /
    • 2017
  • Carbon Fiber Reinforced Plastic (CFRP) has commonly been used to strengthen existing RC structures. Wrapping the whole component with CFRP is an effective method and simple to execute. Besides, specific configuration of CFRP sheets (L, X and T shape) has also been considered in some experiments to examine CFRP effects in advance. This study aimed to provide an optimal CFRP configuration to effectively retrofit the beam-column connection using continuous material topology optimization procedure. In addition, Moved and Regularized Heaviside Functions and penalization factors were also considered. Furthermore, a multi-material procedure was also used to compare with the results from the single material procedure.

Experimental investigation of reinforced concrete columns retrofitted with polyester sheet

  • Chang, Chunho;Kim, Sung Jig;Park, Dongbyung;Choi, Sunghun
    • Earthquakes and Structures
    • /
    • v.6 no.3
    • /
    • pp.237-250
    • /
    • 2014
  • This paper experimentally investigates the seismic performance of RC columns retrofitted with Super Reinforcement with Flexibility (SRF), which is a polyester fiber reinforced polymer. A total of three specimens with a scale factor of 1/2 were constructed and tested in order to assess the structural behavior of the retrofitted RC columns. One specimen was a non-seismically designed column without any retrofit, while others were retrofitted with either one or two layers of the polyester belt with urethane as the adhesive. Static cyclic testing with a constant axial load was conducted to assess the seismic performance of the retrofitted RC columns. It is concluded that the SRF retrofitting method increases the strength and ductility of the RC columns and can also impact on the failure mode of the columns.

Pseudo Dynamic Test of the Seismically Isolated RC Piers (지진격리설계된 RC교각의 유사동적 실험)

  • Kim Young-Jin;Kwahk Im-Jong;Cho Chang-Beck;Kwark Jong-Won
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2004.11a
    • /
    • pp.25-28
    • /
    • 2004
  • Many highway bridges in Korea need seismic retrofit because only one decade has passed since the seismic design criteria was introduced. In this experimental study, the effectiveness of base isolation bearings was discussed for the seismic retrofit of the highway bridges. Four real scale RC pier specimens were constructed for the test. These RC piers didn't have seismic details. Except for one RC pier for the pilot test, three types of bearings such as Pot bearing, Rubber bearing (RB), Lead-rubber bearing (LRB) were applied to the other RC piers respectively. The RC pier with Pot bearing means current state of the prototype bridge that is not retrofitted seismically. And two RC piers with RB or LRB mean assumed states of the prototype bridge that are retrofitted seismically. To simulate dynamic behavior of these RC piers under earthquake loads, Pseudo-dynamic test method was used.

  • PDF

Analytical Study of a Historic Stone Arch Bridge After Retrofit to Evaluate Dynamic Characteristics and Structural Behavior (보수전과 후의 홍예교의 동적특성과 구조성능에 대한 해석연구)

  • Lee, Ga-Yoon;Lee, Sung-Min;Lee, Kihak
    • Journal of Korean Association for Spatial Structures
    • /
    • v.20 no.4
    • /
    • pp.177-184
    • /
    • 2020
  • This study evaluates safety assessment before and after repair of Seonamsa temple seungseon bridge, which refer to the representative Hongye bridge in Korea. In this approach natural frequency of the structure were considered in the modeling procedure. Trial & error method is applied to obtain the approximate natural frequency before and after retrofit construction. Stiffness of the actual structure was examined to account for the dynamic characteristics of Hongye bridge measured in the field and adjusting parameters in computer modeling. The safety and usability of the stone structure in terms of load bearing capacity and displacement were examined.

Seismic Retrofit in Educational Facilities Using Attaching Composite Material (부착형 복합소재를 이용한 교육시설의 내진보강)

  • Park, Choon-Wook;Song, Geon-Su;Park, Ik-Hyun;Kim, Dong-Hwi
    • Journal of Korean Association for Spatial Structures
    • /
    • v.13 no.3
    • /
    • pp.73-81
    • /
    • 2013
  • In paper after the strong earthquake of recently the Korea neighborhood, the Korean government survey show that the 86% of school buildings in Korea are in potential damage risk and only 14% of them are designed as earthquake-resistance buildings. Earthquake Reinforcing projects of school have been a leading by the ministry of education, however their reinforcing methods done by not proved a engineering by experiment which results in uneconomical and uneffective rehabilitation for the future earthquake. An experimental and analytical study have been conducted for the shear reinforcing method of column by axis and horizontal axis load using attaching composite beam. Based on the previous research, in this study, Design examples are given to show the performance evaluation for the column reinforcing of old school buildings using nonlinear analysis is going to be conducted and strengthening method is going to be on the market after their performance is proved by the test.