• Title/Summary/Keyword: retinal imaging

Search Result 27, Processing Time 0.029 seconds

Complex Conjugate Resolved Retinal Imaging by One-micrometer Spectral Domain Optical Coherence Tomography Using an Electro-optical Phase Modulator

  • Fabritius, Tapio E.J.;Makita, Shuichi;Yamanari, Masahiro;Myllyla, Risto A.;Yasuno, Yoshiaki
    • Journal of the Optical Society of Korea
    • /
    • v.15 no.2
    • /
    • pp.111-117
    • /
    • 2011
  • Full-range spectral domain optical coherence tomography (SD-OCT) with a 1-${\mu}m$ band light source is shown here. The phase of the reference beam is continuously stepped while the probing beam scans the sample laterally (B-scan). The two dimensional spectral interferogram obtained is processed by a Fourier transform method to obtain a complex spectrum leading to a full-range OCT image. A detailed mathematical explanation of the complex conjugate resolving method utilized is provided. The system's measurement speed was 7.96 kHz, the measured axial resolution was $9.6{\mu}m$ in air and the maximum sensitivity 99.4 dB. To demonstrate the effect of mirror image elimination, In vivo human eye pathology was measured.

High-Speed SD-OCT for Ultra Wide-field Human Retinal Three Dimensions Imaging using GPU (병렬처리 그래픽 기술 기반의 Spectral Domain-Optical Coherence Tomography를 이용한 3차원 광 대역 망막 촬영)

  • Park, Kibeom;Cho, Nam Hyun;Wijesinghe, Ruchire Eranga Henry;Kim, Jeehyun
    • Journal of Biomedical Engineering Research
    • /
    • v.34 no.3
    • /
    • pp.135-140
    • /
    • 2013
  • We have developed an ultra wide-field of view Optical Coherence Tomography(OCT) which has capability to 2D and 3D views of cross-sectional structure of in vivo human retina. Conventional OCT has a limitation in visualizing the entire retina due to a reduced field of view. We designed an optical setup to significantly improve the lateral scanning range to be more than 20 mm. The entire human retinal structure in 2D and 3D was reported in this paper with the developed OCT system. Also, we empirically searched an optimized image size for real time visualization by analyzing variation of the frame rate with different lateral scan points. The size was concluded to be $1024{\times}2000{\times}300$ pixels which took 9 seconds for visualization.

Retinal Blood Vessel Segmentation using Deep Learning (딥러닝 기법을 이용한 망막 혈관 분할)

  • Kim, Beomsang;Lee, Ik Hyun
    • The Journal of Korean Institute of Information Technology
    • /
    • v.17 no.5
    • /
    • pp.77-82
    • /
    • 2019
  • Diabetic retinopathy is a complicated form of diabetes due to circulatory disorder in the peripheral blood vessels of the retina. We segment the microvessel for diagnosing diabetic retinophathy. The conventional methods using filter and features can segment the thick blood vessels, but it has relatively weak for segmenting fine blood vessels. In pre-processing step, noise reduction filter and histogram equalization are applied to suppress the noise and enhance the image contrast. Then, deep learning technique is used for pixel-by-pixel segmentation. The accuracy of conventional methods is between 90% to 94%, while the proposed method has improved as 95% accuracy. There is a problem of segmentation error around the optic disc and exudate due to the network depth. However the accuracy can be improved by modifying the network architecture in the future.

Clinical Feasibility of CT Brain Perfusion in a Dog with Sellar Region Tumor

  • Minji Kim;Gunha Hwang;Jeongmin Ryu;Jiwon Yoon;Moon Yeong Choi;Joong-Hyun Song;Tae Sung Hwang;Hee Chun Lee
    • Journal of Veterinary Clinics
    • /
    • v.41 no.3
    • /
    • pp.178-182
    • /
    • 2024
  • A 10-year-old spayed female Poodle was referred for blindness. On ophthalmic examination, loss of bilateral ocular pupil light reflex, visual loss, and right retinal detachment were confirmed at a local hospital. Magnetic resonance imaging (MRI) of the brain was performed to identify the optic nerve, optic chiasm, and brain disease. A sessile mass centered on the region of the optic chiasm was identified. The mass had iso- to hypointense on fluid-attenuated inversion recovery and T2-weighted images and mildly hypointense on T1-weighted images compared to the gray matter, with strong contrast enhancement. Peripheral edema was also identified. Computed tomography (CT) brain perfusion was performed to obtain additional hemodynamic information about the patient using a multislice CT. CT perfusion showed that the cerebral blood volume in the left temporal lobe region (13.4 ± 1.6 mL/100 g) was decreased relative to the contralateral region (19.9 ± 0.3 mL/100 g). The patient showed decreased appetite and consciousness one week after the CT scan with clinical symptoms worsened. The patient had seizure, tetraparesis, and loss of consciousness. It was euthanized one month later at the request of the owner. This report suggests that CT brain perfusion can provide additional hemodynamic information such as insufficient brain perfusion in sellar region tumor which can help assess potential complications and prognosis and plan treatment.

Role of cyclic AMP in the eye with glaucoma

  • Shim, Myoung Sup;Kim, Keun-Young;Ju, Won-Kyu
    • BMB Reports
    • /
    • v.50 no.2
    • /
    • pp.60-70
    • /
    • 2017
  • Glaucoma is characterized by a slow and progressive degeneration of the optic nerve, including retinal ganglion cell (RGC) axons in the optic nerve head (ONH), leading to visual impairment. Despite its high prevalence, the biological basis of glaucoma pathogenesis still is not yet fully understood, and the factors contributing to its progression are currently not well characterized. Intraocular pressure (IOP) is the only modifiable risk factor, and reduction of IOP is the standard treatment for glaucoma. However, lowering IOP itself is not always effective for preserving visual function in patients with primary open-angle glaucoma. The second messenger cyclic adenosine 3',5'-monophosphate (cAMP) regulates numerous biological processes in the central nervous system including the retina and the optic nerve. Although recent studies revealed that cAMP generated by adenylyl cyclases (ACs) is important in regulating aqueous humor dynamics in ocular tissues, such as the ciliary body and trabecular meshwork, as well as cell death and growth in the retina and optic nerve, the functional role and significance of cAMP in glaucoma remain to be elucidated. In this review, we will discuss the functional role of cAMP in aqueous humor dynamics and IOP regulation, and review the current medications, which are related to the cAMP signaling pathway, for glaucoma treatment. Also, we will further focus on cAMP signaling in RGC growth and regeneration by soluble AC as well as ONH astrocytes by transmembrane ACs to understand its potential role in the pathogenesis of glaucoma neurodegeneration.

Development of Hand-held OCT probe for Ophthalmic Imaging (안구 영상을 위한 OCT용 손잡이 형 프로브의 개발)

  • Cho, Nam-Hyun;Jung, Woong-Gyu;Jung, Un-Sang;Sephen, A.Boppart;Shim, Jae-Hoon;Kim, Jee-Hyun
    • Journal of the Institute of Electronics Engineers of Korea SC
    • /
    • v.48 no.1
    • /
    • pp.24-30
    • /
    • 2011
  • We have developed a hand-held probe for an ophthalmic OCT system. The hand-held probe for imaging was designed to be compact and portable. The cornea and retinal images were acquired by replacing the objective lens at the front of the probe. To verify the performance of the hand-held OCT probe, we acquired two dimensional OCT image of the rat eye in vivo and reconstructed three dimensional rat eye rendering images. In vivo 3D OCT images were showed distinct structural information in the posterior and anterior chamber with minimal motion artifacts. Thereby, OCT imaging speed is suitable for an dynamic in vivo experiment.

AMD Identification from OCT Volume Data using Deep Convolutional Neural Network (심층 컨볼루션 신경망을 이용한 OCT 볼륨 데이터로부터 AMD 진단)

  • Kwon, Oh-Heum;Jung, Yoo Jin;Song, Ha-Joo
    • Journal of Korea Multimedia Society
    • /
    • v.20 no.8
    • /
    • pp.1291-1298
    • /
    • 2017
  • Optical coherence tomography (OCT) is the most common medical imaging device with the ability to image the retina in eyes at micrometer resolution and to visualize the pathological indicators of many retinal diseases such as Age-Related Macular Degeneration (AMD) and diabetic retinopathy. Accordingly, there have been research activities to analyze and process OCT images to identify those indicators and make medical decisions based on the findings. In this paper, we use a deep convolutional neural network for analysis of OCT volume data to distinguish AMD from normal patients. We propose a novel approach where images in each OCT volume are grouped together into sub-volumes and the network is trained by those sub-volumes instead of individual images. We conducted an experiment using public data set to evaluate the performance of the proposed approach. The experiment confirmed performance improvement of our approach over the traditional image-by-image training approach.

A Case of Systemic Lupus Erythematosus Presenting with Amaurosis Fugax without Antiphospholipid Antibodies Syndrome (항인지질항체증후군을 동반하지 않은 일과성 단안 실명으로 발현된 전신성 홍반성 루푸스 1 예)

  • Kim, Jung-Hyun;Hah, Jung-Sang;Park, Mee-Young;Lee, Se-Jin;Lee, Jun
    • Journal of Yeungnam Medical Science
    • /
    • v.23 no.1
    • /
    • pp.113-117
    • /
    • 2006
  • Systemic lupus erythematosus (SLE) is a chronic autoimmune disease that may affect many organ systems including the nervous system. The immune response in patients with SLE can cause inflammation and other damage that can cause significant injury to the arteries and tissues. A 48-year-old woman was admitted to the hospital because of transient monocular blindness. Magnetic resonance imaging and conventional angiography showed severe stenosis of the distal intracranial internal carotid artery. The patient was diagnosed as having SLE but the antiphospholipid antibodies were negative. Amaurosis fugax has not been previously reported as an initial manifestation of SLE in Korea. We report a patient with a retinal transient ischemic attack as the first manifestation of SLE.

  • PDF

High Speed SD-OCT System Using GPU Accelerated Mode for in vivo Human Eye Imaging

  • Cho, Nam Hyun;Jung, Unsang;Kim, Suhwan;Jung, Woonggyu;Oh, Junghwan;Kang, Hyun Wook;Kim, Jeehyun
    • Journal of the Optical Society of Korea
    • /
    • v.17 no.1
    • /
    • pp.68-72
    • /
    • 2013
  • We developed an SD-OCT (Spectral Domain-Optical Coherence Tomography) system which uses a GPU (Graphics Processing Unit) for processing. The image size from the SD-OCT system is $1024{\times}512$ and the speed is 110 frame/sec in real-time. K-domain linearization, FFT (Fast Fourier Transform), and log scaling were included in the GPU processing. The signal processing speed was about 62 ms using a CPU (Central Processing Unit) and 1.6 ms using a GPU, which is 39 times faster. We performed an in-vivo retinal scan, and reconstructed a 3D visualization based on C-scan images. As a result, there were minimal motion artifacts and we confirmed that tomograms of blood vessels, the optic nerve, and the optic disk are clearly identified. According to the results of this study, this SD-OCT can be applied to real-time 3D display technology, particularly auxiliary instruments for eye operations in ophthalmology.

Cerebral fat embolism syndrome: diagnostic challenges and catastrophic outcomes: a case series

  • Hussein A.Algahtani;Bader H. Shirah;Nawal Abdelghaffar;Fawziah Alahmari;Wajd Alhadi;Saeed A. Alqahtani
    • Journal of Yeungnam Medical Science
    • /
    • v.40 no.2
    • /
    • pp.207-211
    • /
    • 2023
  • Fat embolism syndrome is a rare but alarming, life-threatening clinical condition attributed to fat emboli entering the circulation. It usually occurs as a complication of long-bone fractures and joint reconstruction surgery. Neurological manifestations usually occur 12 to 72 hours after the initial insult. These neurological complications include cerebral infarction, spinal cord ischemia, hemorrhagic stroke, seizures, and coma. Other features include an acute confusional state, autonomic dysfunction, and retinal ischemia. In this case series, we describe three patients with fat embolism syndrome who presented with atypical symptoms and signs and with unusual neuroimaging findings. Cerebral fat embolism may occur without any respiratory or dermatological signs. In these cases, diagnosis was established after excluding other differential diagnoses. Neuroimaging using brain magnetic resonance imaging is of paramount importance in establishing a diagnosis. Aggressive hemodynamic and respiratory support from the beginning and consideration of orthopedic surgical intervention within the first 24 hours after trauma are critical to decreased morbidity and mortality.