• Title/Summary/Keyword: retaining wall

검색결과 735건 처리시간 0.22초

임도구조 요인에 따른 절토비탈면 안정구조물의 특성 (Characteristics on Stabilization Measures for Cutting Slopes of Forest Roads)

  • 백승안;지병윤;이준;차두송
    • Journal of Forest and Environmental Science
    • /
    • 제30권1호
    • /
    • pp.71-75
    • /
    • 2014
  • Forest roads failure is one of the most common problems caused by heavy rainfalls. This study investigated the characteristics on stabilization measures installed for cutting slopes failure of forest road resulted from heavy rainfalls. Three primary factors (slope length, slope gradient, soil type) affecting cutting slope failure were considered and stabilization measures were classified into two types (A type: wooden fence, vegetation sandbag, stone masonry; B type: wire cylinder, gabion, concrete retaining wall) through discriminant analysis based on their capacity of resistance to slope failure. Results showed that A type was mainly installed in such conditions as cut slope <8 m, cut slope gradient $30-40^{\circ}$ and soil type with soil while B type occurred in locational conditions as cut slope length >8 m, cut slope gradient < $30^{\circ}$ and > $30^{\circ}$, and soil type of gravelly soil and rock.

영향인자를 고려한 절토사면 보강공법 선정기법 (Determination Technique of Cut-Slope Reinforcing Method Considering the Effect Factor)

  • 한중근;이종영;이명호;최풍곤
    • 한국지반신소재학회논문집
    • /
    • 제6권2호
    • /
    • pp.27-32
    • /
    • 2007
  • 본 연구에서는 절토사면 공법선정시 고려해야 할 영향인자에 대한 가중치 결정과 사면보강공법 선호도를 AHP기법을 이용하여 분석하였다. 연구, 설계, 시공업에 종사하고 있는 전문가를 대상으로 분석한 결과 공법선택시 안정성 및 내구성, 환경성이 가장 중요한 영향인자로 조사되었으며, 안전율 증가법 위주로 분석된 사면보강공법 선호도 조사에서는 경제성과 유지관리 용이성, 안정성에서 가장 우수한 평가를 받은 옹벽공법과 절토공법이 가장 선호도가 높은 공법으로 분석되었다.

  • PDF

버팀보 해체시 안전성 확보를 위한 응력 해제용 굴절지지대 개발 및 성능 평가 (Development and Performance Evaluation of Rotational Strut Segment for Releasing Stress when uninstalled)

  • 박철용;구일근;김현숙;양지연;김형오
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2018년도 춘계 학술논문 발표대회
    • /
    • pp.109-110
    • /
    • 2018
  • Preloading Strut applied during installation of the wall jack, but additionally serves to minimize the displacement of soil pressure acting upon dissolution due to the difficulty. In this study, we developed an index of support for the release of stress to facilitate the dismantling of the strut uninstall. The refractive support the axial force acting on the strut are supportable, is refracted at minimum load, disassembly should be easy. In order to find the optimal shape and structural stability of the refractive support We have performed the numerical analysis and performance test to determine the final model. We carried out model tests and UTM test in order to understand the refractive performance and durability of the refractive support for optimal model. Results of the test UTM is refracted all shot 5 times within a target hit number, it was found that there is no problem of the refractive performance. Further, the results of model experiments, it was found that to ensure sufficient durability more than the performance target value of the pin joint support structure.

  • PDF

쏘일네일링 벽체에 대한 대형파괴재하시험 사례 (A Case Study on the Large Scaled Load Test of Soil Nailed Walls)

  • 강인규;류정수;권영호;이승현;박신영
    • 기술발표회
    • /
    • 통권2006호
    • /
    • pp.135-145
    • /
    • 2006
  • Soil nailing systems are generally many used in underground excavations and reinforcements of slopes since the first construction as a temporary retaining wall in 1993, Korea. In recently, they are many attempts to expand the permanent reinforcements of slopes However, experimental studies related to soil nailing systems are insufficient Specially, there are no researches related in the large scaled load tests of soil nailed walls in Korea In this study, a case study on the large scaled load tests of soil nailed walls is introduced and the behavior characteristic of them is investigated Also, they are proposed allowable deformation corresponding to the serviceability limit of soil nail walls and ultimate deformation corresponding to the collapse state of the walls. These results can be applied to the maintenance management of soil nailed walls And analysis on the required minimum factor of safety of soil nailed walls using the relation curve of load ratio and deformation ratio are carried out

  • PDF

전라남도 $\bigcirc\bigcirc$우회도로 붕괴절토사면 사례 연구 (A Case Study on the Collapsed Cut-Slope in $\bigcirc\bigcirc$ detour at JeonranamDo)

  • 김승현;구호본;이정엽
    • 한국지반공학회:학술대회논문집
    • /
    • 한국지반공학회 2008년도 추계 학술발표회
    • /
    • pp.966-973
    • /
    • 2008
  • In recent, the collapses of cut-slope is gradually increased due to the heavy rains accompanied by typhoon. Specially, many cut-slope failures and landslides was happened to Goheung, Yeosu, Suncheon region, Jeonranamdo in the middle of September 2007. The slope of investigation is width 20 m, height 22 m, and the circular failure was occurred. The parent rocks of the slope are pyroclastic rock, namely andesite, andesitic tuff et al. and the weathering grade is completely weathered to residual soils owing to rapid weathering process and has the existence of fault zone and mafic dyke. Also, lots of extension cracks are presented and the hydrologic condition is very deteriorated. As a result of the limit equilibrium analysis, the safety factor is 1.09(in dry season) and 0.64(in wet season). For the stabilization of the cut-slope, we decided to use the retaining wall, anchors and drainage apparatus.

  • PDF

편토압이 심한 도심지 대심도 암반굴착공사에서의 계측사례 (A Case Study on the Field Monitoring of the Deep Rock Excavation Site in Urban Area on Severe Unbalanced Pressure Condition)

  • 김태섭;김웅규;정창원;한철희
    • 한국지반공학회:학술대회논문집
    • /
    • 한국지반공학회 2008년도 추계 학술발표회
    • /
    • pp.1259-1267
    • /
    • 2008
  • One of the most important item for insuring the stability of ground in urban deep excavation site near by major structure such as subway is displacement control of earth retaining wall. The field monitoring system is classified by two types as manual system and automatic system. The application case of latter type of field monitoring is increased because real time measurement is possible in automatic system and that is correspondent with the recent constructional trend. Though the automatic monitoring system is more useful and advanced than manual monitoring system, accuracy of the system is not verified sufficiently. It was examined that the reliance of automatic monitoring system in this paper through the comparison of monitoring result obtained one of deep urban excavation site in which the each type of monitoring system was executed concurrently. Result of the examination is that the two types of monitoring system is generally alike in view of monitoring result, so the engineering reliance of automatic system was confirmed in case site. This study was researched in restricted one case site, so it is expected more precise analysis from security of more data monitored and progressive study.

  • PDF

현장시험을 통한 DEW 지압형 앵커의 적용성평가 (Application of DEW Anchor with Field Test)

  • 최경집;박우영;유성진;이성락
    • 한국지반공학회:학술대회논문집
    • /
    • 한국지반공학회 2009년도 세계 도시지반공학 심포지엄
    • /
    • pp.745-751
    • /
    • 2009
  • The anchor is used extensively for a cutting slope, an earth retaining wall, an uplift resistance of sub-structures and so on at civil engineering projects and is classified by aim in use, tendon material, and ground/tension fixing type. It can be distinguished extensively into friction type, bearing type, and complex type by ground fixing type. Generally, bond length of friction type anchor has application to 3~10m depending on the friction-resistance characteristics. In this study, 'DEW(double enlargement wedge) bearing type anchor' of new concept is devised. The bond length is about 0.6~0.8m. It can be used on the ground to have the strength characteristics above it of weathered rock. There are merits which are 'period reduction' and 'cost saving' through the minimum of the boring length. In addition, it is so called environmentally friendly Methods because it can reduce the quantity of carbon dioxide through the reducing drilling machine operation time.

  • PDF

연약지반에서 심층혼합처리공법의 개량체 형상변화에 미치는 시공조건 (Effects of construction conditions on deep mixing method for soft ground)

  • 이광열;황재홍
    • 한국지반공학회:학술대회논문집
    • /
    • 한국지반공학회 2009년도 세계 도시지반공학 심포지엄
    • /
    • pp.809-814
    • /
    • 2009
  • Deep mixing method has been used for ground improvement and foundation system for embankment, port and harbor foundations, retaining wall, and liquefaction mitigations. It has attractive benefits because it is not only improved strength of soft ground but superior for prevention of settlement. However, the quality controls of improved mass affect to the efficiency of the deep mixing method is not properly established. These effects vary depending upon the construction environments and conditions of agitation in consideration of an agitator. The strength and shape of the improved column are not unique and these are affected by mechanical properties of agitators. In this study, in order to investigate the efficiency of deep mixing method for ground improvement on a soft clay ground, experimental studies are performed considering mechanical properties of agitator; the location of exit-hole of admixtures, an angle of mixing wing and a speed of revolution. The experiments are conducted with the simulated apparatus for deep mixing plant that reduced the scale in 1:8 of the real plant. According to the results, the diameter and shape of improved column mass vary depending on the mechanical properties and operating conditions of agitator. Its quality is better when the exit-hole of admixtures is located in the mixing wing, when an angle of mixing wing is large, and when the speed of revolution is rapid.

  • PDF

2종류 또는 3종류의 흙으로 뒷채움이 구성될 경우의 정적 및 동적 수평주동토압합력 예측 (A Prediction of the Static and Dynamic Horizontal Active Thrusts Exerted by a Backfill Consisting of Two or Three Layers of Different Properties)

  • 김홍택;강인규
    • 대한토목학회논문집
    • /
    • 제11권2호
    • /
    • pp.65-76
    • /
    • 1991
  • 본 연구에서는, 서로 다른 토질정수를 지닌 2종류 또는 3종류의 흙으로 뒷채움이 구성되는 다양한 경우에, 내진설계를 포함한 실제의 옹벽 설계에서 요구되는 토압예측을 위한 시도가 이루어 졌다. 이를 위해, Mononobe-Okabe해석법 및 secant방법이 이용되었다. 제시된 해석방법을 토대로 2종류의 흙으로 뒷채움이 구성되는 경우에 효율적인 구성형태에 관련된 분석이 이루어 졌다. 아울러 2종류 또는 3종류의 흙으로 뒷채움이 구성된 설계예를 통해, 어느 특정층의 토질정수를 토대로 토압예측이 이루어지는 경우에 예상되는 문제점 분석이 이루어 졌다.

  • PDF

현장노출시험에 의한 부직포 지오텍스타일의 내후성 평가 (Weatherability Assessment of Nonwoven Geotextiles by Field Exposure Test)

  • 전한용;유승조;김영윤;변성원;이웅의
    • 한국지반신소재학회논문집
    • /
    • 제3권1호
    • /
    • pp.37-42
    • /
    • 2004
  • 보강토 옹벽시스템에서, 부직포 지오텍스타일은 블럭이 시공될 때 보강토체의 전면에 노출, 포설되어 있다. 임시구조물에 보강토 옹벽이 적용될 때 지오텍스타일은 시공기간 중 일광에 노출되게 된다. 이 기간 중, 자외선에 의해 부직포 지오텍스타일의 분해가 발생하게 된다. 따라서 현장시공의 관점에서 부직포 지오텍스타일의 자외선 저항성이 명확하게 평가되어야만 한다. 본 연구에서는 실험실 및 현장시험을 수행하여 KOESWall 시스템에 사용되는 부직포 지오텍스타일의 자외선 저항성이 평가되었고, 그 결과를 SEM 사진과 인장특성으로 나타내었다.

  • PDF